Loading...
HomeMy WebLinkAboutREVISION, WS LOT 18 - ENERGY CALCS 10.16.21FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-ASHMERE GOODMAN 18 Builder Name: KHOVNANIAN HOMES Street: 5154 ARMINA PL, Permit Office: City, State, Zip: FORT PIERCE , FL , Permit Number: Owner: ASHMERE MODEL LOT 18 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41472.9 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1316.90 ft' b. Frame - Wood, Adjacent R=11.0 156,00 ft' 3. Number of units, if multiple family i c. N/A R= ft2 4. Number of Bedrooms 3 d• N/A R= ft' 5. Is this a worst case? No 11. Ceiling Types (1464.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1464,00 W 6. Conditioned floor area above grade (It') 1464 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 7. Windows(146.6 sgft.) Description Area 12. Ducts R ft' a. U-Factor: Dbl, U=0.32 88.38 ft' a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 42,08 ft' 13, Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a. Central Unit 28.0 SEER:16.00 c. U-Factor: Dbl, U=0.27 16.19 ft' SHGC: SHGC=0.32 14Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.314 Area Weighted Average Overhang Depth: 3 ft. . a. Electric Strip Heat 23.0 COPA.00 14 8, Skylights Area c. U-Factor:(AVG) N/A 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1464.0 sgft.) Insulation Area EF: 0.930 A. Slab -On -Grade Edge Insulation R=0.0 1464.00 ft' b. Conservation features b. WA R= ft' None c. N/A R= ft' 16. Credits Pstat Glass/Floor Area: 0.100 Total Proposed Modified Loads: 48.00 PASS Total Baseline Loads: 48,86 I hereby certify that the plans and spe 'ficalions covered by this calculation are incompliance with he FI dda Energy Code. PREPARED BY: DATE: flu I hereby certify th f this building, as designed, is in compliance with the Florida E r )r Code. OWNER/AGE DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553,908 Florida Statutes. BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/8/2021 8:09 PM EnergyGauge� USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-ASHMERE GOODMA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1464 Lot # Owner Name: ASHMERE MODEL LOT 18 Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlalBook: Builder Name: KHOVNANIAN HOMES Rotate Angle: 180 Street: 5154 ARMINA PL. Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Family Type: Detached New/Existing: New (From Plans) Whole House Fan: No City, State, Zip: FORT PIERCE , FL , Comment: CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Healing Design Daily Temp Winter Summer Degree Days Moisture Range _ FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1464 12883.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 BED 2 141 1240.8 No 1 3 1 No Yes Yes 2 HALL BATH 63 554 No 0 1 No Yes Yes 3 FOYER 120 1056 No 0 1 No Yes Yes 4 LAUNDRY 64 563 No 0 1 No Yes Yes 5 BED 3 143 1258 No 1 1 No Yes Yes 6 KIT DIN GRT RM 576 5069 No 0 1 No Yes Yes 7 PANTRY 35 308 No 0 1 No Yes Yes 8 MAST SUITE 182 1602 No 2 1 No Yes Yes 9 M BATH 90 792 No 0 1 No Yes Yes 10 WIC MAST 50 440 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Insulatio BED 2 32.5 ft 0 141 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio HALL BATH 9 ft 0 63 ft' ____ 1 0 0 3 Slab -On -Grade Edge Insulatio FOYER Eft 0 120 ft° ____ 1 0 0 _ 4 Slab -On -Grade Edge Insulatio LAUNDRY 7.5 ft 0 64 ft' ____ 1 0 0 5 Slab -On -Grade Edge Insulatio BED 3 24 ft 0 143 ft' ___ 0 1 0 6 Slab -On -Grade Edge Insulatio KIT DIN GRT RM 45 ft 0 576 ft' ____ 0.25 0.75 0 7Slab-On-Grade Edge Insulatio PANTRY 1 ft 0 35 ft' ____ 1 0 0 10/8/2027 8:09 PM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant So((ware Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-Grade Edge Insulatio MAST SUITE 26.5 ft 0 182 W ____ 0 1 0 9 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 90 ft' 1 0 0 ____ 10SIab-On-Grade Edge Insulatio WIC MAST 5 It 0 50 ft' 0 1 0 ____ ROOF / Roof Gable Roof Red Solar SA Emilt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1586 It' 0 ft' Medium N 0.9 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 160 1464 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type i Under Attic (Vented) BED 2 30 Blown 141 ft' 0.1 Wood 2 Under Attic (Vented) HALL BATH 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) FOYER 30 Blown 120 ft' 0.1 Wood 4 Under Attic (Vented) LAUNDRY 30 Blown 64ft' 0.1 Wood 5 Under Attic (Vented) BED 3 30 Blown 143 ft' 0.1 Wood 6 Under Attic (Vented) KIT DIN GRT RM 30 Blown 576 ft' 0.1 Wood 7 Under Attic (Vented) PANTRY 30 Blown 35 ft' 0.1 Wood 8 Under Attic (Vented) MAST SUITE 30 Blown 182 W 0.1 Wood 9 Under Attic (Vented) M BATH 30 Blown 90 W 0.1 Wood 10 Under Attic (Vented) WIC MAST 30 Blown 50 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below e R_Vai 1 S=>N Exterior Concrete Block - Int Insul BED 2 4.1 6 9 9 4 63.0 ft' 0 0 0.5 0 2 E=>W Exterior Concrete Block - Int Insul BED 2 4.1 10 8 9 4 99.6 ft' 0 0 0.5 0 3 N=>S Exterior Concrete Block - Int Insul BED 2 4.1 12 7 10 0 125.8 ft' 0 0 0.5 0 4 N=>S Exterior Concrete Block - Int InsdHALL BATH 4.1 8 1 10 0 80.8 ft' 0 0 0.5 0 5 E=>W Exterior Concrete Block- Int Insul FOYER 4.1 5 10 9 4 54.4 fl' 0 0 0.5 0 6 S=>N Exterior Concrete Block - Int Insul BED 3 4.1 12 7 9 4 117.4 (i' 0 0 0.5 0 7 N=>S Exterior Concrete Block - Int InsKIT DIN GRT 4.1 21 7 10 0 215.8 ft' 0 0 0.5 0 8 W=>E Exterior Concrete Block - Int Ins14IT DIN GRT 4.1 10 4 9 4 96.4 ft' 0 0 0.5 0 _ 9 S=>N Exterior Concrete Block - Int InsMAST SUITE 4.1 13 7 9 4 126.8 ft' 0 0 0.5 0 10 W=>E Exterior Concrete Block - Int InsMAST SUITE 4.1 12 2 9 4 113.6 ft' 0 0 0.5 0 _ 11 S=>N Exterior Concrete Block - Int Insul M BATH 4.1 8 9 9 4 81.7 ft' 0 0 0.5 0 12 S=>N Exterior Concrete Block - Int InsuWIC MAST 4.1 4 10 9 4 45.1 ft' 0 0 0.5 0 10/8/2021 8:09 PM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 PoPhA aena_4)ngn INPI IT Al IMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Ft in Ft R-vai F r Ana r Grate t- To Wall Type R-value in Area _ 13 W=>E Garage Frame - Wood KIT DIN GIRT 11 18 0 8 8 156.0 ' 0 0 0.5 0 14 W=>E Exterior Concrete Block - Int InsKIT DIN GIRT 4.1 10 4 9 4 96A ft' 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>W Insulated FOYER None .39 3 2 6 10 21.6 ft' 2 E=>W Wood FOYER None .39 2 10 6 10 19.4 ft' WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 180 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E=>W 2 Metal Double (Tinted) Yes 0.27 0.32 N 16.2 ft' 1 It 0 in 1 It 0 in None None _ 2 S=>N 6 Metal Double (Tinted) Yes 0.32 0.3 N 16.2 ft' 1 It 0 in 1 It 0 in None None _ 3 N=>S 7 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 ft2 1 it 0 in 1 ft 0 in None None 4 W=>E 8 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 W 1 It 0 in t It 0 in None None 5 W=>E 14 Metal Double (Tinted) Yes 0.55 0.34 N 42.1 ft' It ft 0 in 1 ft 0 in None None 6 W=>E 10 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 ft' 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 385 W 385 ft' 64 It 8.8 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1503 82.46 154.81 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 23 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singe SEER: 16 28 kBtu/hr B40 elm 0.71 1 sys#1 10/D/2021 8:09 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 non IKU31IT ¢1111A11#ARV CW11=R6W1 IRT RFPl7RT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply — ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft2 FOYER 1 ft2 Default Leakage FOYER (Default) (Default) 1 1 TEMPERATURES Programabl[e CFans: Is eating Feb Feb [[ Mar Apr ([eiling j[` jjj Jul [ J Aug ((jj Sep ((jj EE Octf[ HDec l l Jan L Venting (1 Jan O J Feb [X� [(X11 Mar [X� Apr jMa [ May tXl Jun Jun l ] Jul ri EXI 11 Aug IXJ ll 1 Sep ll�xll L.1 i7ct [X1 Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) PM 80 78 78 78 78 78 78 78 78 78 78 80 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 PM 68 68 68 68 Heating (WEH) PM 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Delault(8 Ibs/sq.ft. 0 ft2 0 It 0.3 BED 2 Default(8 Ibs/sq.ft. ft2 It 0.3 HALL BATH Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbslsq.ft. ft2 It 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 It 0.3 BED 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 KIT DIN GRT RM Default(8 lbs/sq.ft. ft2 It 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 It 0.3 MAST SUITE Default(8 lbs/sq.ft. ft2 It 0.3 M BATH Default(8 Ibs/s .ft. ft2 It 0.3 WIC MAST 10/8J2021 8:09 PM EnergyGauge�l USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPertormance Index, the more efficient the home. 5154 ARMINA PL., FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1316,90 W b. Frame -Wood, Adjacent R=11.0 156,00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1464.00 ft2 6. Conditioned floor area (ftl 1464 b. N/A R= ft2 7. Windows" Description Area c. N/A R= III a. U-Factor: Dbi, U=0.32 88.38 ft2 12. Ducts, location & Insulation level R ft2 SHGC: SHGC=0.30 a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300 b. U-Factor: Dbl, U=0.55 42.08 ft' SHGC: SHGC=0.34 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.27 16.19 ft2 a. Central Unit 28.0 SEER:16.00 SHGC: SHGC=0.32 d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 23.0 COP:1.00 Area Weighted Average Overhang Depth: 3,869 ft. Area Weighted Average SHGC: 0,314 8, Skylights Description Area 15, Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.93 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1464,00 ft2 Credits (Performance method) Pstat b. N/A R= ft' c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Compliant features. Builder Signature: \ �{ Date: 2- Address of New Home:City1FL Zip: "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/8/2021 8:09 PM EnergyGaugei8l USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1