HomeMy WebLinkAboutAPPROVED, WINDOW & DOOR SCHEDULEA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10% of least horizontal dimension or 40% of the mean roof height. whichever is smaller. but not less than 4% of least horizontal dimension or 3 ft OPENING LOCATION NUMBER (Location) Corner Zone or Interior IS THIS A WINDOW OR DOOR GLAZING TYPE PRODUCT ACCEPTANCE NUMBER PRODUCT APPROVAL APPROVED PRESSURE RATING REQUIRED OPENING DESIGN PRESSURE MAXIMU M TESTED SIZE ROUGH OPENING DIMENSIONS MULTIPLE WINDOW ARE SHUTTERS REQ YIN PSF (-) PSF (+) PSF (-) PSF MULLION REQ YIN/NA 1 End Window 7/8"Lami[G FL15768.9 60 65 40.2 -53.8 48 x 63 36x15 No No 2 End Window Vg"Lami'G FL15768.9 60 65 40.2 -53.8 48 x 63 36x15 No No 3 End Window 7/8" Land 1G FL15780.8 55 65 39.6 -52.7 54 x 76.1 3 6x49 No No 4 End Window 7/8"Lind lG FL15780.8 55 65 39.4 -52.3 s4x76.5 5207 No No 5 Int Window 718" Lami IG FL15780.8 55 65 38.1 -41.5 54 x 76.5 52x61 No No 6 End Window WS"Lami"' FL15780.8 55 65 39.5 -52.5 54x76s 18x74 No No 7 End Window 71s„Lami1G FL15768.9 60 65 40.2 -53.8 48x63 35x15 No No 8 Int Window 718"Lami10 FL23505.3 60 65 40.2 -43.6 54x76.5 35x24 No No 9 End Window 7/8"Lam! Jr, FL23505.3 60 65 40.2 -53.8 54x76.5 35x24 No No 10 End Window 718°LamilG FL15780.8 55 65 39.5 -52.5 54x76.5 18x74 No No