HomeMy WebLinkAboutAPPROVED, WINDOW & DOOR SCHEDULEA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10% of least horizontal dimension or 40% of the mean roof height. whichever is smaller. but not less than 4% of least horizontal dimension or 3 ft
OPENING
LOCATION
NUMBER
(Location)
Corner Zone
or Interior
IS THIS A
WINDOW
OR DOOR
GLAZING
TYPE
PRODUCT
ACCEPTANCE
NUMBER
PRODUCT APPROVAL
APPROVED PRESSURE RATING
REQUIRED OPENING
DESIGN PRESSURE
MAXIMU
M
TESTED
SIZE
ROUGH
OPENING
DIMENSIONS
MULTIPLE
WINDOW
ARE
SHUTTERS
REQ YIN
PSF
(-) PSF
(+) PSF
(-) PSF
MULLION
REQ YIN/NA
1
End
Window
7/8"Lami[G
FL15768.9
60
65
40.2
-53.8
48 x 63
36x15
No
No
2
End
Window
Vg"Lami'G
FL15768.9
60
65
40.2
-53.8
48 x 63
36x15
No
No
3
End
Window
7/8" Land 1G
FL15780.8
55
65
39.6
-52.7
54 x 76.1
3 6x49
No
No
4
End
Window
7/8"Lind lG
FL15780.8
55
65
39.4
-52.3
s4x76.5
5207
No
No
5
Int
Window
718" Lami IG
FL15780.8
55
65
38.1
-41.5
54 x 76.5
52x61
No
No
6
End
Window
WS"Lami"'
FL15780.8
55
65
39.5
-52.5
54x76s
18x74
No
No
7
End
Window
71s„Lami1G
FL15768.9
60
65
40.2
-53.8
48x63
35x15
No
No
8
Int
Window
718"Lami10
FL23505.3
60
65
40.2
-43.6
54x76.5
35x24
No
No
9
End
Window
7/8"Lam! Jr,
FL23505.3
60
65
40.2
-53.8
54x76.5
35x24
No
No
10
End
Window
718°LamilG
FL15780.8
55
65
39.5
-52.5
54x76.5
18x74
No
No