HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENT
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL22259-R3
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC
Address/Phone/Email 1 Owens Corning Parkway
Toledo, OH 43657
(740) 587-3562
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation
Report
Zachary R. Priest
Florida License PE-74021
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL22259_R3_COI_OCR17002.3 2020 FBC Eval Beacon Tri-Built Syn Underlayment final.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D 1970 2015
ASTM D 226 2009
ASTM D 4533 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/21/2020
Date Validated 10/23/2020
Date Pending FBC Approval 10/28/2020
Date Approved 12/16/2020
Summary of Products
FL #Model, Number or Name Description
22259.1 Beacon Tri-Built A mechanically attached, synthetic underlayment for use in steep slope roofing
applications as an alternative to ASTM D 226, Type I or Type II felt.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL22259_R3_II_OCR17002.3 2020 FBC Eval Beacon Tri-Built Syn Underlayment
final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL22259_R3_AE_OCR17002.3 2020 FBC Eval Beacon Tri-Built Syn Underlayment
final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by
phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must
provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply
a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
CREEK
Technical Services, LLC
OCR17002.3 FL22259-R3 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 7TH EDITION (2020)
Manufacturer: BEACON SALES ACQUISITIONS, INC. Issued October 18, 2020
c/o OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438-7465
Quality Assurance: Intertek Testing Services NA, Inc. (QUA1673)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Edition: Florida Building Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ)
Code Sections: 1507.1.1, 1518.4
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
Intertek Testing Services NA Ltd. (TST1509) 102389161COQ-002A AC 188 2012
Intertek Testing Services NA Ltd. (TST1509) 102389161COQ-004 ASTM D 226 2009
PRI Construction Materials Technologies (TST5878) OCR-259-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST5878) 1378T0127 ASTM D 4533
ASTM D 5035
ASTM D 751
2015
2011(2019)
2019
PRODUCT DESCRIPTION
Beacon Tri-Built A mechanically attached, synthetic underlayment for use in steep slope roofing
applications as an alternative to ASTM D 226, Type I or Type II felt that has
demonstrated a minimum tear strength per ASTM D 4533 of 15 pounds, a minimum
tensile strength per ASTM D 5035 of 20 pounds/inch, and meets liquid water
transmission test of Section 8.6 of ASTM D 4869.
A CREEK
Technical Services, LLC
OCR17002.3 FL22259-R3 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC
Beacon Tri-Built
APPLICATION
Unless otherwise noted, the following application details shall be followed for New and Existing construction.
See manufacturer’s installation instructions for further detail.
Roof Deck: The roof deck shall be constructed of closely fitted wood sheathing for new or existing
construction. Plywood deck shall be installed in accordance with FBC requirements.
Roof decks shall have no more than 1/8” gap at abutting joints.
Attachment method
(Non-HVHZ):
Underlayment shall be attached in accordance with the FBC Section 1507.1.1,
Table 1507.1.1.1 and manufacturer’s installation instructions.
Attachment method
(HVHZ):
Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch
end lap and be fastened as specified in FBC Section 1518.2.
Allowable roof coverings
(Non-HVHZ):
Mechanically attached roof systems as prescribed in FBC Table 1507.1.1.1.
Allowable roof coverings
(HVHZ):
Underlayment shall be used with mechanically attached asphalt shingles.
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
5) Roof slope limitations shall be in accordance with FBC requirements.
6) The underlayment may be used as described in other current FBC product approval documents.
7) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
8) The underlayment shall not be installed over existing roof coverings.
9) The underlayment shall be installed starting at the eave in horizontal layers such that the laps shed water
from the deck. The first layer shall cover the entire bottom edge of the deck. End laps sh all be staggered a
minimum of 72-inches from the preceding course.
10) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
A CREEK
Technical Services, LLC
OCR17002.3 FL22259-R3 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC
Beacon Tri-Built
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
2020.10.18
11:45:25
-04'00'