HomeMy WebLinkAboutWS LOT 40 - ENERGY CALCSFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-ASHMERE GOODMAN 40 Builder Name: KHOVNANIAN HOMES
Street: 5145 ARMINA PL. Permit Office:
City, State, Zip: FORT PIERCE , FL , Permit Number:
Owner: ASHMERE MODEL LOT 40 @ WATERSTONE Jurisdiction:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans) 10. Wall Type41472.9 sgft.) Insulation Area
2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1316.90 ft2
b. Frame -Wood, Adjacent R=11.0 156,00 ft2
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 3 d. N/A R= ft2
5. Is this a worst case? No 11. Ceiling Types (1464.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1464.00 ft'
6. Conditioned floor area above grade (ft2) 1464 b. N/A R= ft2
Conditioned floor area below grade (ft2) 0 c. N/A R= ft2
T Windows(146.6 sgft.) Description Area 12. Ducts R ft2
a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300
a. U-Factor: Dbl, U=0.32 88.38 ft2
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55 42.08 ft2 13. Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.34 a. Central Unit 28.0 SEER:16.00
c. U-Factor: Obl, U=0.27 16.19 ft2
SHGC: SHGC=0.32
Area Weighted Average Overhang Depth: 3.869 ft. 14. Heating systems kBtu/hr Efficiency
Area Weighted Average SHGC: 0,314 a. Electric Strip Heal 23.0 COP:1.00
8, Skylights Area
c. U-Factor:(AVG) N/A ft2 15. Hot water systems
SHGC(AVG): N/A a. Electric Cap: 50 gallons
9. Floor Types (1464o sgft.) Insulation Area EF: 0.930
a. Slab -On -Grade Edge Insulation R=0.0 1464.00 ft2 b. Conservation features
b. N/A R= ft2 None
c. N/A R= ft2 16. Credits Pstat
Glass/Floor Area: 0,100 Total Proposed Modified Loads: 47,84 PASS
Total Baseline Loads: 48.86
I hereby certify that the plans and specifi�jcations covered by
this calculation are in compliance with t{�e Florida Ene�gy(
Code. II II
PREPARED BY:
DATE:
I hereby certify t his building, as designed, is in compliance
with the Florida �r y Code.
OWNER/AGE
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes,
BUILDING OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7,00 ACH50 (R402.4.1.2).
10/8/2021 8:11 PM EnergyGaugeQil USA 7.0.00 - FlaRes2020 FBC 7lh Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020
INPUT SUMMARY
-CHECKLIST
PROJECT
-REPORT
Title: KHOV-ASHMERE GOODMA Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1464
Lot #
Owner Name: ASHMERE MODEL LOT 40 Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: KHOVNANIAN
HOMES Rotate Angle: 0
Street:
5145 ARMINA PL.
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Family Type: Detached
New/Existing: New (From Plans)
Whole House Fan: No
City, State,
Zip:
FORT PIERCE ,
FL,
Comment:
CLIMATE
Design Temp
Int Design Temp
Healing Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce
FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1464 12883.2
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 BED 2
141 1240.8 No
1
3
1
No
Yes
Yes
2 HALL BATH
63 554 No
0
1
No
Yes
Yes
3 FOYER
120 1056 No
0
1
No
Yes
Yes
4 LAUNDRY
64 563 No
0
1
No
Yes
Yes
5 BED 3
143 1258 No
1
1
No
Yes
Yes
6 KIT DIN GIRT RM
576 5069 No
0
1
No
Yes
Yes
7 PANTRY
35 308 No
0
1
No
Yes
Yes
8 MAST SUITE
182 1602 No
2
1
No
Yes
Yes
9 M BATH
90 792 No
0
1
No
Yes
Yes
10 WIC MAST
50 440 No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter
R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge
Insulatio BED 2 32.5 ft 0
141 ft2
____
0 1
0
2 Slab -On -Grade Edge
Insulatio HALL BATH 9 ft 0
63 ft'
____
1 0
0
3 Slab -On -Grade Edge
Insulatio FOYER Eft 0
120 ft'
____
1 0
0
4Slab-On-Grade Edge
Insulatio LAUNDRY 7.5 It 0
64 ft'
1 0
0
5 Slab -On -Grade Edge
Insulatio BED 3 24 ft 0
143 ftz
____
0 1
0
6 Slab -On -Grade Edge
Insulatio KIT DIN GRT RM 45 ft 0
576 ft'
____
0.25 0.75
0
7 Slab -On -Grade Edge
Insulatio PANTRY i ft 0
35 ftz
____
1 0
0
10/812021 8:11 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type
Space Perimeter Perimeter
R-Value
Area
Joist
R-Value
Tile
Wood Carpet
8 Slab
-On -Grade Edge Insulatio MAST SUITE 26.5
ft 0
182 ft'
____
0
1
0
9 Slab -On -Grade Edge Insulatio
M BATH 9 ft
0
90 ft'
____
1
0
0
10SIab-On-Grade Edge Insulatio
WIC MAST 5 it
0
50 ft'
0
1
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type
Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition
shingles 1586 W
0 ft'
Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
/
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented
150
1464 ft'
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
BED 2
30
Blown
141112
0A
Wood
2
Under Attic (Vented)
HALL BATH
30
Blown
63 ft'
0.1
Wood
3
Under Attic (Vented)
FOYER
30
Blown
120 ft'
0.1
Wood
4
Under Attic (Vented)
LAUNDRY
30
Blown
64 ft'
0.1
Wood
5
Under Attic (Vented)
BED 3
30
Blown
143 ft'
0.1
Wood
6
Under Attic (Vented)
KIT DIN GRT RM 30
Blown
576 Itz
0.1
Wood
7
Under Attic (Vented)
PANTRY
30
Blown
35 ft'
0.1
Wood
8
Under Attic (Vented)
MAST SUITE
30
Blown
182 ft'
0.1
Wood
9
Under Attic (Vented)
M BATH
30
Blown
90 ft'
0.1
Wood
10
Under Attic (Vented)
WIC MAST
30
Blown
50 ft'
0.1
Wood
WALLS
Adjacent
Cavity Width Height
Sheathing
Framing Solar
Below
Ornt
To IA/mil T-ypp
Space
_ We Gr
I� r=f
In
A[ea
R_v�u P
Fr„ -firm
Absor. _G
1
S
Exterior Concrete
Block -
Int Insul BED 2
4.1 6
9 9
4
63.0 W
0
0
0.5
0
_ 2
E
Exterior Concrete
Block -
Int Insul BED 2
4.1 10
8 9
4
99.6 ft'
0
0
0.5
0
_ 3
N
Exterior Concrete
Block -
Int Insul BED 2
4.1 12
7 10
0
125.8 ft'
0
0
0.5
0
4
N
Exterior Concrete
Block -
Int InsdHALL BATH
4.1 8
1 10
0
80.8 W
0
0
0.5
0
_ 5
E
Exterior Concrete
Block -
Int Insul FOYER
4.1 5
10 9
4
54.4 ft'
0
0
0.5
0
_ 6
S
Exterior Concrete
Block-
Int Insul BED 3
4.1 12
7 9
4
117.4 ft'
0
0
0.5
0
7
N
Exterior Concrete
Block -
Int InsKIT DIN GRT
4.1 21
7 10
0
215.8 ft'
0
0
0.5
0
8
W
Exterior Concrete
Block -
Int InsKIT DIN GRT
4.1 10
4 9
4
96.4 ft'
0
0
0.5
0
_ 9
S
Exterior Concrete
Block -
Int InsMAST SUITE
4.1 13
7 9
4
126.8 ft'
0
0
0.5
0
10
W
Exterior Concrete
Block -
Int InsMAST SUITE
4.1 12
2 9
4
113.6 ft'
0
0
0.5
0
_ 11
S
Exterior Concrete
Block -
Int Insul M BATH
4.1 8
9 9
4
81.7 ft'
0
0
0.5
0
12
S
Exterior Concrete
Block -
Int InsuWIC MAST
4.1 4
10 9
4
45.1 ft'
0
0
0.5
0
10/8/2021 8:11 PM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
UnDKA Dnnc noon IAIDI IT CI IMMARY I :l lPrt(I IAT PPPORT
WALLS
Adjacent
Cavity Width Height
Sheathing
Framing Solar
Below
Space
1-Value P In Ff
In Aran
R.Ninhip
o
_ 13 W
Garage
Frame - Wood KIT DIN GRT 11 18 0 8
8 156.0 ft'
0
0 0.5
0
14 W
Exterior
Concrete Block - Int InsKIT DIN GRT 4.1 10 4 9
4 96.4 ft'
0
0 0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U•Value
Width
Height
Area
Ft
In
Ft In
_ 1
E
Insulated FOYER
None
.39 3
2
6 10
21.6 W
2
E
Wood
FOYER
None
.39 2
10
6 10
19.4 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
E 2
Metal Double
(Tinted) Yes
0.27 0,32 N
16.2 ft' 1 it 0 in
1 8 0 in
None
None
_ 2
S 6
Metal Double
(Tinted) Yes
0.32 0.3 N
16.2 W 1 It 0 in
1 ft 0 in
None
None
3
N 7
Metal Double
(Tinted) Yes
0,32 0.3 N
24.1 ft' 1 it 0 in
1 It 0 in
None
None
4
W 8
Metal Double
(Tinted) Yes
0.32 0.3 N
24.1 W 1 ft 0 in
1 ft 0 in
None
None
5
W 14
Metal Double
(Tinted) Yes
0.55 0.34 N
42.1 W 11 ft 0 in
1 ft 0 in
None
None
6
W 10
Metal Double
(Tinted) Yes
0.32 0.3 N
24.1 ft' 1 it 0 in
1 It 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
385 ft'
385 ft'
64 It
8.8 It
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000391
1503 82.46 154.81
.1312
7
HEATING SYSTEM
mom
#
System
Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric
Strip Heat/
None
COPA
23 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System
Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1
Central
Unit/
Split
Singi SEER: 16
28 kBtu/hr
840 cfm
0.71 1
sys#1
10f8/2021 8:11 PM EnargyGauge� USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
PnRM Ran.-qmn INPI IT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System
Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.93
50 gal 60.9 gal
120 deg
None
SOLAR HOT
WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
--- Supply ---
-- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 300 ft'
FOYER
1 W
Default Leakage
FOYER
(Default)
(Default)
1 1
TEMPERATURES
Programablee
Y
Fans:
CApr
jThermostajt:
((jj
r[eiling
May
[[ jj
XJ
(j
Aug
((`jj]
Sep
r(
33
jJ
HeaDec
t ng [X] Jan �")
Feb
[X] Mar
Apr
j May
Jun [X] Jul
EX]
[[[[
Oct
Nov
[Ef
Dec
Venting II 11 Jan
Feb
11X11 Mar
(X�
[
t Jun ll 11 Jul
l
]Aug
[ 1 Sep
tXJ
[XI
(X)
lXl
Thermostat Schedule: HERS
2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78 78
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
66
PM
68
68
68
68
68 68
68
68
68
68
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 W
Oft
0.3
BED 2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
HALL BATH
Default(8 lbs/sq.ft.
ft'
It
0.3
FOYER
Default(8 lbs/sq.ft,
ft'
It
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
it'
ft
0.3
BED 3
Default(8 lbs/sq.ft.
W
It
0.3
KIT DIN GIRT RM
Default(8 lbs/sq.ft.
ft'
It
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft'
It
0.3
MAST SUITE
Default(8 lbs/sq.ft.
ft'
It
0.3
M BATH
Default(8 lbs/s.ft.
ft'
It
0.3
WIC MAST
10/8/2021 8:11 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPertormance Index, the more efficient the home.
5145 ARMINA PL., FORT PIERCE, FL,
1. New censlruclion or existing New (From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a. Concrete Block - Int Insul, Extedor R=4.1 1316,90 fN
b. Frame - Wood, Adjacent R=11.0 156,00 ft'
3. Number of units, if multiple family 1 c. N/A R= ft'
4. Number of Bedrooms 3 d. N/A R= ft'
5. Is this a worst case? No 11. Ceiling Type and Insulation level Insulation Area
a. Under Attic (Vented) R=30.0 1464,00 ft'
6. Conditioned floor area (ft') 1464 b. NIA R= ft'
7. Windows** Description Area c. N/A R= ft'
a. U-Factor: Dbl, U=0.32 88.38 ft' 12, Ducts, location & Insulation level R ft'
SHGC: SHGC=0.30 a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300
b. U-Factor: Dbl, U=0.55 42.08 ft'
SHGC: SHGC=0.34 13. Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl, U=0.27 16.19 ft' a. Central Unit 28.0 SEER:16.00
SHGC: SHGC=0.32
d. U-Factor: N/A ft' SHGC: 14. Healing systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.869 ft. a. Electric Strip Heat 23.0 COPA.00
Area Weighted Average SHGC: 0.314
8, Skylights Description Area 15. Hot water systems
a. Electric Cap: 50 gallons
a. U-Factor(AVG): N/A ft' EF: 0.93
SHGC(AVG): N/A b. Conservation features
9. Floor Types Insulation Area None
a. Slab -On -Grade Edge Insulation R=0.0 1464,00 ft' Credits (Performance method) Pstat
b. N/A R= ft'
c. N/A R= ft'
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be Installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Co ompliant features. ^ 1
Builder Signature: "' ' ,1 Date:
Address of New Home:. rJ�j F ; Y� fl ( L% t , t= A� City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/8I2021 8:11 PM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1