Loading...
HomeMy WebLinkAboutWS LOT 40 - ENERGY CALCSFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-ASHMERE GOODMAN 40 Builder Name: KHOVNANIAN HOMES Street: 5145 ARMINA PL. Permit Office: City, State, Zip: FORT PIERCE , FL , Permit Number: Owner: ASHMERE MODEL LOT 40 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41472.9 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1316.90 ft2 b. Frame -Wood, Adjacent R=11.0 156,00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1464.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1464.00 ft' 6. Conditioned floor area above grade (ft2) 1464 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 T Windows(146.6 sgft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300 a. U-Factor: Dbl, U=0.32 88.38 ft2 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 42.08 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 28.0 SEER:16.00 c. U-Factor: Obl, U=0.27 16.19 ft2 SHGC: SHGC=0.32 Area Weighted Average Overhang Depth: 3.869 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0,314 a. Electric Strip Heal 23.0 COP:1.00 8, Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1464o sgft.) Insulation Area EF: 0.930 a. Slab -On -Grade Edge Insulation R=0.0 1464.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0,100 Total Proposed Modified Loads: 47,84 PASS Total Baseline Loads: 48.86 I hereby certify that the plans and specifi�jcations covered by this calculation are in compliance with t{�e Florida Ene�gy( Code. II II PREPARED BY: DATE: I hereby certify t his building, as designed, is in compliance with the Florida �r y Code. OWNER/AGE DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes, BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7,00 ACH50 (R402.4.1.2). 10/8/2021 8:11 PM EnergyGaugeQil USA 7.0.00 - FlaRes2020 FBC 7lh Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY -CHECKLIST PROJECT -REPORT Title: KHOV-ASHMERE GOODMA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1464 Lot # Owner Name: ASHMERE MODEL LOT 40 Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANIAN HOMES Rotate Angle: 0 Street: 5145 ARMINA PL. Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Family Type: Detached New/Existing: New (From Plans) Whole House Fan: No City, State, Zip: FORT PIERCE , FL, Comment: CLIMATE Design Temp Int Design Temp Healing Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1464 12883.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BED 2 141 1240.8 No 1 3 1 No Yes Yes 2 HALL BATH 63 554 No 0 1 No Yes Yes 3 FOYER 120 1056 No 0 1 No Yes Yes 4 LAUNDRY 64 563 No 0 1 No Yes Yes 5 BED 3 143 1258 No 1 1 No Yes Yes 6 KIT DIN GIRT RM 576 5069 No 0 1 No Yes Yes 7 PANTRY 35 308 No 0 1 No Yes Yes 8 MAST SUITE 182 1602 No 2 1 No Yes Yes 9 M BATH 90 792 No 0 1 No Yes Yes 10 WIC MAST 50 440 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 2 32.5 ft 0 141 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio HALL BATH 9 ft 0 63 ft' ____ 1 0 0 3 Slab -On -Grade Edge Insulatio FOYER Eft 0 120 ft' ____ 1 0 0 4Slab-On-Grade Edge Insulatio LAUNDRY 7.5 It 0 64 ft' 1 0 0 5 Slab -On -Grade Edge Insulatio BED 3 24 ft 0 143 ftz ____ 0 1 0 6 Slab -On -Grade Edge Insulatio KIT DIN GRT RM 45 ft 0 576 ft' ____ 0.25 0.75 0 7 Slab -On -Grade Edge Insulatio PANTRY i ft 0 35 ftz ____ 1 0 0 10/812021 8:11 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio MAST SUITE 26.5 ft 0 182 ft' ____ 0 1 0 9 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 90 ft' ____ 1 0 0 10SIab-On-Grade Edge Insulatio WIC MAST 5 it 0 50 ft' 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1586 W 0 ft' Medium N 0.9 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1464 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 2 30 Blown 141112 0A Wood 2 Under Attic (Vented) HALL BATH 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) FOYER 30 Blown 120 ft' 0.1 Wood 4 Under Attic (Vented) LAUNDRY 30 Blown 64 ft' 0.1 Wood 5 Under Attic (Vented) BED 3 30 Blown 143 ft' 0.1 Wood 6 Under Attic (Vented) KIT DIN GRT RM 30 Blown 576 Itz 0.1 Wood 7 Under Attic (Vented) PANTRY 30 Blown 35 ft' 0.1 Wood 8 Under Attic (Vented) MAST SUITE 30 Blown 182 ft' 0.1 Wood 9 Under Attic (Vented) M BATH 30 Blown 90 ft' 0.1 Wood 10 Under Attic (Vented) WIC MAST 30 Blown 50 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt To IA/mil T-ypp Space _ We Gr I� r=f In A[ea R_v�u P Fr„ -firm Absor. _G 1 S Exterior Concrete Block - Int Insul BED 2 4.1 6 9 9 4 63.0 W 0 0 0.5 0 _ 2 E Exterior Concrete Block - Int Insul BED 2 4.1 10 8 9 4 99.6 ft' 0 0 0.5 0 _ 3 N Exterior Concrete Block - Int Insul BED 2 4.1 12 7 10 0 125.8 ft' 0 0 0.5 0 4 N Exterior Concrete Block - Int InsdHALL BATH 4.1 8 1 10 0 80.8 W 0 0 0.5 0 _ 5 E Exterior Concrete Block - Int Insul FOYER 4.1 5 10 9 4 54.4 ft' 0 0 0.5 0 _ 6 S Exterior Concrete Block- Int Insul BED 3 4.1 12 7 9 4 117.4 ft' 0 0 0.5 0 7 N Exterior Concrete Block - Int InsKIT DIN GRT 4.1 21 7 10 0 215.8 ft' 0 0 0.5 0 8 W Exterior Concrete Block - Int InsKIT DIN GRT 4.1 10 4 9 4 96.4 ft' 0 0 0.5 0 _ 9 S Exterior Concrete Block - Int InsMAST SUITE 4.1 13 7 9 4 126.8 ft' 0 0 0.5 0 10 W Exterior Concrete Block - Int InsMAST SUITE 4.1 12 2 9 4 113.6 ft' 0 0 0.5 0 _ 11 S Exterior Concrete Block - Int Insul M BATH 4.1 8 9 9 4 81.7 ft' 0 0 0.5 0 12 S Exterior Concrete Block - Int InsuWIC MAST 4.1 4 10 9 4 45.1 ft' 0 0 0.5 0 10/8/2021 8:11 PM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 UnDKA Dnnc noon IAIDI IT CI IMMARY I :l lPrt(I IAT PPPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1-Value P In Ff In Aran R.Ninhip o _ 13 W Garage Frame - Wood KIT DIN GRT 11 18 0 8 8 156.0 ft' 0 0 0.5 0 14 W Exterior Concrete Block - Int InsKIT DIN GRT 4.1 10 4 9 4 96.4 ft' 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U•Value Width Height Area Ft In Ft In _ 1 E Insulated FOYER None .39 3 2 6 10 21.6 W 2 E Wood FOYER None .39 2 10 6 10 19.4 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Metal Double (Tinted) Yes 0.27 0,32 N 16.2 ft' 1 it 0 in 1 8 0 in None None _ 2 S 6 Metal Double (Tinted) Yes 0.32 0.3 N 16.2 W 1 It 0 in 1 ft 0 in None None 3 N 7 Metal Double (Tinted) Yes 0,32 0.3 N 24.1 ft' 1 it 0 in 1 It 0 in None None 4 W 8 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 W 1 ft 0 in 1 ft 0 in None None 5 W 14 Metal Double (Tinted) Yes 0.55 0.34 N 42.1 W 11 ft 0 in 1 ft 0 in None None 6 W 10 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 ft' 1 it 0 in 1 It 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 385 ft' 385 ft' 64 It 8.8 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1503 82.46 154.81 .1312 7 HEATING SYSTEM mom # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 23 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singi SEER: 16 28 kBtu/hr 840 cfm 0.71 1 sys#1 10f8/2021 8:11 PM EnargyGauge� USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 PnRM Ran.-qmn INPI IT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS --- Supply --- -- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft' FOYER 1 W Default Leakage FOYER (Default) (Default) 1 1 TEMPERATURES Programablee Y Fans: CApr jThermostajt: ((jj r[eiling May [[ jj XJ (j Aug ((`jj] Sep r( 33 jJ HeaDec t ng [X] Jan �") Feb [X] Mar Apr j May Jun [X] Jul EX] [[[[ Oct Nov [Ef Dec Venting II 11 Jan Feb 11X11 Mar (X� [ t Jun ll 11 Jul l ]Aug [ 1 Sep tXJ [XI (X) lXl Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 66 PM 68 68 68 68 68 68 68 68 68 68 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 W Oft 0.3 BED 2 Default(8 Ibs/sq.ft. ft' ft 0.3 HALL BATH Default(8 lbs/sq.ft. ft' It 0.3 FOYER Default(8 lbs/sq.ft, ft' It 0.3 LAUNDRY Default(8 Ibs/sq.ft. it' ft 0.3 BED 3 Default(8 lbs/sq.ft. W It 0.3 KIT DIN GIRT RM Default(8 lbs/sq.ft. ft' It 0.3 PANTRY Default(8 Ibs/sq.ft. ft' It 0.3 MAST SUITE Default(8 lbs/sq.ft. ft' It 0.3 M BATH Default(8 lbs/s.ft. ft' It 0.3 WIC MAST 10/8/2021 8:11 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPertormance Index, the more efficient the home. 5145 ARMINA PL., FORT PIERCE, FL, 1. New censlruclion or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Extedor R=4.1 1316,90 fN b. Frame - Wood, Adjacent R=11.0 156,00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 11. Ceiling Type and Insulation level Insulation Area a. Under Attic (Vented) R=30.0 1464,00 ft' 6. Conditioned floor area (ft') 1464 b. NIA R= ft' 7. Windows** Description Area c. N/A R= ft' a. U-Factor: Dbl, U=0.32 88.38 ft' 12, Ducts, location & Insulation level R ft' SHGC: SHGC=0.30 a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300 b. U-Factor: Dbl, U=0.55 42.08 ft' SHGC: SHGC=0.34 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.27 16.19 ft' a. Central Unit 28.0 SEER:16.00 SHGC: SHGC=0.32 d. U-Factor: N/A ft' SHGC: 14. Healing systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.869 ft. a. Electric Strip Heat 23.0 COPA.00 Area Weighted Average SHGC: 0.314 8, Skylights Description Area 15. Hot water systems a. Electric Cap: 50 gallons a. U-Factor(AVG): N/A ft' EF: 0.93 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1464,00 ft' Credits (Performance method) Pstat b. N/A R= ft' c. N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be Installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Co ompliant features. ^ 1 Builder Signature: "' ' ,1 Date: Address of New Home:. rJ�j F ; Y� fl ( L% t , t= A� City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/8I2021 8:11 PM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1