Loading...
HomeMy WebLinkAboutCompaction testUES Project No: Workorder No: Report Date: 3360.1700014.0000 248348-1 10/08/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:Doyle Masonry, Inc.UES Technician:Chad Plum P.O. Box 12339 Fort Pierce, FL 34979-2339 Date Tested:10/08/2021 Project:Port St Lucie CSD/CMT Various Location, TBD County, FL Type of Test: Area Tested: House Pad, 10701 S. Ocean Dr.Field:ASTM D-6938 Nuclear Gauge Method Material:Fill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 East Corner 0-1 ft 102.1 13.1 97.1 11.8 95 Pass 2 West Corner 0-1 ft 102.1 13.1 97.1 12.7 95 Pass 3 Center 0-1 ft 102.1 13.1 97.4 12.3 95 Pass Reviewed By GFA International, Inc FBPE Registry No.4930 Allan G. Abubakar, P.E. STATE OF FLORIDA Professional Engineer No. 69952 This item has been digitally signed and sealed by Allan G. Abubakar, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1