HomeMy WebLinkAboutCompaction testUES Project No:
Workorder No:
Report Date:
3360.1700014.0000
248348-1
10/08/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:Doyle Masonry, Inc.UES Technician:Chad Plum
P.O. Box 12339
Fort Pierce, FL 34979-2339
Date Tested:10/08/2021
Project:Port St Lucie CSD/CMT
Various Location, TBD County, FL
Type of Test:
Area Tested: House Pad, 10701 S. Ocean Dr.Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 East Corner 0-1 ft 102.1 13.1 97.1 11.8 95 Pass
2 West Corner 0-1 ft 102.1 13.1 97.1 12.7 95 Pass
3 Center 0-1 ft 102.1 13.1 97.4 12.3 95 Pass
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G.
Abubakar, P.E. on the date adjacent to the seal. Printed copies of
this document are not considered signed and sealed and the
signature must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1