Loading...
HomeMy WebLinkAboutCarports Generic PlansFBC APPROVED PRODUCTS LIST MAXIMUM ALLOWABLE TABLE 9 WIND SPEED RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS QA ' APPROVAL PARTIALLY AVERAGE FASTENER SPACING PRODUCT CATEGORY SUB CATEGORY MANUFACTURER EXPIRATION ON -CENTERS ALONG RAFTERS OR No. & DATE DATE OPEN ENCLOSED ENCLOSED PURLINS, AND POSTS OR GIRTS MAXIMUM STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC. FL6596.1-R6 04l05/27 180 180 180 '(INCHES) WIND ULTIMATE NOMINAL POST I RAFTER 26 Gauge AG Panel 12/15/20 RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC.- FL6702.1-R6 03/14/27 180 180 180 CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 26 Gauge AG Panel 12/15/20 110 TO 150 89 TO 116 5.0 6 6 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.3-R6 03/14/27 N/A 164 143 I C 26 Gauge Dutch Lap Wall Panel 12/15/20 " 151 TO 180 117 TO 139 4.0 6 6 STRUCTURAL COMPONENTS FLOOD VENT CRAWL SPACE DOOR SYSTEMS, INC. FL29622.1-R1 09/30/22 N/A N/A N/A NOTES: 1. Specifications applicable to 26.gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 16x8 Flood Vent 02/28/21 gauge hat channel roof purlins. 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27° (.1.5:12 to 6:12 pitch). Spacing EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996,3-R2 08/26/25 N/A 139 139 requirements for other roof heights and/or slopes may vary. Series 402-14 02/28/21 GROUND ANCHOR SCHEDULE EXTERIOR DOORS, SWINGING ELIXIR DOOR.AND METAL COMPANY FL17996.5-R2 08/19/25 N/A 174 155 ULTIMATE WIND SPEED'(mph) METAL CARPORT INSTALLATION PLANS Series 407 02/28/21 AND DETAILS AND FRAMING AND 110 120 130 140 150 160 170 180. EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888'1-R6 12/31/21 N/A 180 174 12 FASTENER SPECIFICATIONS Mode1.203 (12' Max. Width) 02/09/21 FL16806.1-R5 04/05/27 N/A 179 154 .-. 14 30'-Anchor FOR CONSTRUCTION IN THE STATE OF FLORIDA EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. Detail 1D 16 Steel Roll Up Sheet Door (12' Max..Width) 12/16/20 0 FL168o6.2-R5 04/05/27 v 18 PREPARED FOR: EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. N/A. 180 180 � CAROLINA CARPORTS INC. Steel Roll -Up Sheet Door- (8' Max. Width) 12/16/20 9 20 48'Anchor, P.O. BOX 1263 EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.3-R5 04/05/27 N/A 155 133 z 22 Detail•111 C DOBSON, NORTH CAROLINA 27017 ,Steel Roll -Up Sheet Door - (16' Max. Width) 12/16/20 p 24 d PREPARED BY - EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL168.06.4-R5 04/06/27 N/A 180 172 m 26 BECHTOL ENGINEERING AND TESTING, INC. Steel Roll -Up Sheet Door - (10' Max. Width) 12/16/20 f 28 60 Anchor 605 WEST NEW YORK AVENUE WINDOWS SINGLE HUNG MI WINDOWS AND DOORS FL17499.1-R8 10/17/23 NIA 175 157 30 t Detail 1C DELAND, FLORIDA 32720 1 u27/2o r " Certificate of Authorization No. 00005492 Model 185SH D'EfiAlI.S 1 :CAN D I D SHOWN ON SHEET 4 OF 6 r� W F ® R NO i'rq OFIS AND WINDOWS SryOWN MAY BESUPSTITUTED'FOR DIFfPR.ENj PRoDIJCT LINf+f fDt4ff.Mt?DEl s; I'RpVIPEO,jH FOLLOWING CONpIj�OIVs ARE MET: a �1 r A PRODUCT SHALLHAVE A VALID FBC PRODUCT APPROVAL y 4( _,> P L 1A, \ O E I B. COMPONENTS AREJNSTALLED ACCOROING TO MANUFACTURER'S INSTALLA710N REQIJ EMENTS. ' MAXIMUM;POST SPACING 1=OR DUTCH LAP IS.4.0' Q 2. FRAKIING CONNECTIONS FOR DOOR AND, WINDOW FRAMES REMAIN THE SAME FOR 9013SCIT,UTEO PRODUCTS. ITEADERS AND WINDOW.RAILS MAY 8E RAISED OR LOWERED AS NECESSARY TO•ACCOMODATE � � " �� � � � � C O U � Sl`1�.STITUTEO PRQDUCT. OCC �G GENERAL NOTES: 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS, AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO THIS IS TO CERTIFY THATTHE CALCULATIONSAND n� SET FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY -BACKS, SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN f/ TM $E S RUCTU ES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY'I),CAPABLE OF -SUPPORTING -DEAD LOAD OF THE STRUCTURE A� APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS ACCORDANCE IT 2. E, T,,. h.. WITH THE REQUIREMENTS OF SECTION 1609OF NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS,1k.lNbOWS, OR OTHER COMI?.ONENTS NOT LISTED IN THE FBC APPROVED ;PRODUCTS LIST (THIS SHEET), NOT PROVIDED AND INSTALLED' BY CAROU" CARPORTS, THE FLORIDA BUILDING CODE D ^ SEVENTH EDITION (202D). IMC.,;W jiICl1 EXERT ADDITIONAL LOADS ON,T)iE STRUCTURE SHA4is 8E AT THE OWNER'S RISi�. BECHTOL;ENGII>tEERING.AND TESTING, $1 TALL NOT BE RESPO, NSIRLE FOR STRUCTURAL DAMAGE OR ,FAILURE DUE TO'THE �✓ APPLICATION OF ADOITIONAL'.LOADS. 3• ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL OR ZINC PLATED. 4• ALL COMPONENTS -AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE LOCATION OF THE BUILDING WITHIN THE STATE OF FLOROA. FILE 5• ALL FIELD FRAMING CONNECTIONS SHALL BE'#12-14 x 39' SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. BECHTQI:� EFt�( N TING, INC. ' 605 WEST•p1E RKAVE E F 6, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 .4XW1 :4 DELAND�L032720 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. 36 7• BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS.ARE NOT REQUIRED FOR CONCRETE FOOTING _ AND/OR CONCRETE SLAB CONSTRUCTION, SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR. REQUIREMENTS. 8• CONCRETE ANCHORS. SHALL BE TAPCON REDHEAD LDT 1/2" x 6" OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. Thomas 8e I: .. Florida LI're d.38 ATE rip <C/ _ 9, POST/RAFTER .BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. a 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SEVENTH EDITION (2020) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC CA AIRPORTS, NC. C. FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED. SEVENTH EDITION (2020) - BUILDING. MINIMUM ALLOWABLE 11. 14 GA FRAMING: 2-1/2" x 2-1/2" TUBE STEEL (TS) WITH 2A/4" x 2-1l4" TS NIPPLES. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA 12 GA FRAMING: 2-1/4" x 2-1/4" TS WITH 2" x 2" TS NIPPLES. 01/05/2021 12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF M BECHTOL ENGINEERING mkb `�"'� NTS OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER AAID7E8T/NG, Inc. -Ib G21oD1 EVERY 305 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6. WH°b IOW° .W- n� uro� a�� "�1°""�""�'"'00pnm � TB SHEET 1 OF 6 BOW FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF BOND FRAME RAFTER UTILITY BUILDING - HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) - ENCLOSED LENGTH VARIES - =_ TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOTTO'SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX_ EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX SAVE. FRAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) ENCLOSED LENGT VARIES — TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - VERTICAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF FLOOD VENT (As applicable). ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR. (As applicable) (As applicable) (As applicable) (As applicable) r72_i_ ENCLOSED LENGT VARIES _ ---- - TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION. TYPICAL SIDE ELEVATION TYPICAL END: ELEVATION 1 I I I 1 NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO.SCALE \ \ TkFq�CALE H H E BECUti IAGINEERING AND T Imo, INC. 605 WF�T NEWYORK N �_ DELARtD• FLOf21DA 32 . l$53 ���� COF g (�t4�.c•- CODE CO = . _� s COUNtli - Thomas "c P:E. Florida Lic�rysa 38538c . R1D P . • � � L /ONAk-E CAR0L��iIA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA TYPICAL BOW RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION ECUTOGENGINEERING ' .t °"" M_ 01/0512021 „..� NOT TO SCALE NOT TO SCALE NOT TO SCALE aRi mkb tb NTS G21001 mwtuu6a awrtaw.w.-eV=m ffALN0wmauarenew Exoc Ai7O M TB SHEET 2 OF 6 -4 26 GA GALVANIZED METAL ROOF'PANELS FASTENED TO RAFTERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 12 ­� 3 j 24" 16 GA U-CHANNEL BRACE J FASTENED TO RAFTER WITH (2) #12-14 x 3W SDF"s AT EACH END (A PER BRACE) 24' MAXII.SL U RAFTER SPAN OI4 SINGLE RAFTER -24'TO 301 RAFTER SPAN REQUIRES A TRUSSED RAFTER TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOW FRAME NOT TO SCALE TYPICAL RAFTER/POST FRAMING PLAN - BOW FRAME NOT TO SCALE 0" (TYPICAL)' GA. GALVANIZED METAL ROOF PANELS 3TENED TO RAFTERS PER MANUFACTURER'S_ TALLATION INSTRUCTIONS12 3 24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2)'#12-14 x3/4" SDF's AT EACH END (4 PER BRACE) 24' MA O >24' TO 30' Pn TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOX EAVE - HORIZONTAL ROOF NOT TO SCALE TYPICAL RAFTER/POST FRAMING PLAN - BOX SAVE NOT TO SCALE SEE TABLE 1 OPENING FOR SWINGING SHEET DOOR WITH NONSTRUCTURAL 1OF6 HEADER TYPICAL SIDE WALL OPENINGS FRAMING PLAN NOT TO SCALE 6" WELD ALL WEB CONNECTIONS, BOTH SIDES to FULL 6" WELD BOTH SIDES OPTIONAL 24'=V TO 30' TRUSSED RAFTER - BOW NOT TO SCALE SEE TABLE 1 SHEET 1 OF 6 GPEWNGFOR, 12, MAX. OPENING FOR. ROLL -UP DOOR WITH NON-STRUCTURAL 6'- 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO PURLINS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS � 1-1/2" 18'GAUGE FURRING CHANNEL(PURLIN) 24.16 GA U=CHANNEL BRACE FASTENED TO RAFTER WITH (2).#12-14 x 3A' SDF'S AT EACH END (4 PER BRACE)' 24' TO 3W TYPICAL INTERIOR RAFTERIPOST FRAME. SECTION - VERTICAL ROOF NOT TO SCALE 1-112" 18 GAUGE FURRING. CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14x 314" SELF DRILLING FASTENER SPACED NOT MORE THAN 48' O.C. I - .3 4 SEE TABLE 1 SHEET 1 OF 6 I I LENG VARIES DEPENDING ON NUMBER` AND SPACINGOF RAFTERS -I TYPICAL POST/RAFTER FRAMING PLAN - VERTICAL_ ROOF NOT TO SCALE TYPICAL END WALL OPENINGS POST/RAFTER FRAMING PLAN NOT TO SCALE WELD ALL WEB CONNECTIONS, BOTH SIDES _ 6' TYPICAL BOW RAFTER GABLE END FRAMING PLAN NOT TO SCALE TYPICAL.BOX EAVE RAFTER GABLE END FRAMING PLAN NOT TO SCALE FILE, COPY 24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 k 314" SELF -DRILLING, SCREWS AT EACH END (4:PER BRACE), ROOF EXTENSION OPTION `- MAIN-STRUCTUR�, ` } I I I I 1 / STANDARD LEAN-TO OP N TYPICAL LEAN-TO OPTIONS FRAMING PLA FROIIT [`,SHOWN) �� ITV NOT TO SCALE (BOX EAVE RAFTER SHOWN; ONLY STAN9 N T ! ' PLI r((-BOW FRAME RAFTER' 24" 16 GA U-CHANNEL BRACE (V TO 7' POST) 48" 16 GA U•CIHANNEL BRACE (V TO 14' POST) BRACE ANGLE SHALL BE MIN. 30" TO MAX. 45"'fROM HORIZONTAL FULL 6° WELD BOTH SIDES OPTIONAL 24'-1" TO 30.' TRUSSED RAFTER - BOX EAVE rug g Q FREESTANDING LEAN-TO FRAMING PLAN INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT ANCHOR OR 1/2" x MINIMUM 5-1/2' EXPANSION ANCHOR THROUGH BASE RAIL WITHIN W OF EACH RAFTER POSTS ALONG SIDES AND EVERY END WALL POST ALONG END WALL SECTIONS (r4"MINIMUM _I I•"-2" MINIMUM 2-1/2" EMBEDMENT MONOLITHIC CONC. FOOTING (2500 PSI MIN.) REINFORCED WITH 2 #6s CONTINUOUS CONCRETE BASE RAIL AN I / t Not To Scale DRILL5/8' HOLE THROUGH THE 2" WASHERS' BASE RAIL AND SECURE TO ANCHOR EYE WITH 112" DIAMETER TS CONTINUOUS OLT THROUGH-B�. A/ BASE RAIL MINIMUMA' CONTINUOUS 4" CONCRETE.PAVEMENT EYE ANCHOR CONCRETE BASE RAIL ANCHORAGE 1 E Not ToScale (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL`1B) TS TRUSSED RAFTER CHORD, OR NON-STRUCTURAL HEADER T$ END POST ORDOOR/ WINDOW FRAME POST < TS BASE/WINDOW RAIL OR NON-STRUCTURAL HEADER (12 GA IF ROLL -UP DOORFRAME) 6. - 2"x2"x2" 16 GA ANGLE CLIP SECURETO POST (EACH SIDE) AND RAFTER;CHORD/RAIL WITH (4) #12-14'x 3/4' SDFs, (2) ON TOP OR BOTTOM, (2) ON SIDE t�4 NOTE: AT ROLL-UP.DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING: POST TO RAIL, TRUSS CHORD, OR NON-STRUCTURAL HEADER CONN. DETAIL Y Not To Scaie INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT ANCHOR OR 1/2" x MINIMUM 5-1/2' EXPANSION ANCHOR DRILL 5/8' HOLE THROUGH THE THROUGH BASE RAIL WITHIN'B" OF EACH BASE RAIL AND SECURE TO RAFTER POSTS "ALONG SIDES AND EVERY END ANCHOR EYE WITH 1/2" DIAMETER WALL POST ALONG END WALL SECTIONS THROUGH -BOLT 6" MINIMUM 2-1/2" EMBEDMENT MINIMUM CONTINUOUS 4" CONCRETE PAVEMENT CONCRETE BASE RAIL ANCHORAGE Not To Scale (OPTIONAL - OPEN CARPORTS:ONLY) 24' 16 GA U-CHANNEL BRACE (5' TO T POST) 48' 16 GA.U-CHANNEL BRACE (IT TO 14+ POST) BRACE ANGLE SHALL BE MIN..45' TO MAX,. 60' FROM HORIZONTAL NIPPLETO,, 3 RAFTER / V I TS RAFTER 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4"'SDF's BOX EAVE RAFTER/POST DETAIL Lh Not To Scale TS RAFTER POST 1-1/2. x 1-1/2' x 2716 GA CLIP ANGLESECURETO POST AND BASE RAIL WITH (4) #12-14 x3/4" SDFS, (2) ON TOP, (2) ON SIDE `TS CONTINUOUS BASE RAIL END POST/BASE RAIL CONN. Not To Scale TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE WASHERS -TS CONTINUOUS BASE RAIL EYE ANCHOR 5/8' ROD 48' LONG WITH 6' HELIX OR 5/8' ROD 60" LONG (SEE GROUND'A)NCHOR WITH 7- HELIX, SCHEDULE, SHEET i OF 6+ AS APPLICABLE FOR APPLICABILITY) BASE RAIL DEEP ANCHORAGE Not To Scale NO SCREWS REQUIRED IN BOW BEND_ 1 —a1-5" TS BOW RAFTER; 24" 16 GA U-CHANNEL BRACE (S TO 4W 16 GA U-CHANNEL BRACE (&,TO BRACE ANGLE -SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL 3" 3^ 6" LONG TS NIPPLE SECURE RAFTER AND POST TO NIPPLE WITH (4) #12-14 x 3/4" TS. RAFTER -POST SELF -DRILLING FASTENERS �o� BOW RAFT��i`E�ll�� UK co NolToScale MW ®®� CO i A �-� ST, LUCIE C R � ��. - -TS POST 2" x TX 2" 16 GA ANGLE CLIP SECURE TO POST AND TOP OF HEADER OR BOTTOM OF WINDOW RAIUGIRT WITH (4) #12-14 x 3/4" SDF's (2) ON TOP OR BOTTOM, (2) ON SIDE NON-STRUCTURAL HEADER I I TS WINDOW RAIL OR GIRT FOR VERTICAL SIDING OPTION NON-STRUCTURAL HEADER,. WINDOW ��6 RAIL, OR GIRT TO POST CONN. DETAIL J Not To Scale DRILL 5/8' HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2" DIAMETER THROUGH -BOLT TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE WASHERS -TS CONTINUOUS BASE RAIL EYE ANCHOR (SEE GROUId6 ANCFIOf2 5/8" ROD.30"'LONG SCHEDULE, SHEET 1 OF 6, WITH DBL4" HELIX FOR APPLICABIPTY) NIPPLE TO BASE RAIL BASE RAIL ANCHORAGE 1 D Not To Scale 6" LONG TS; NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x'3/4" SDPS RAFTER POST CONTINUOUS BASE RAIL �) POST/BASE RAIL CONN. DETAIL J Not To Scale FILE COPY ITGUENGINEERING AND T"TfidG, INC. I ST NFW YOR N`I1� OE38 385 GN '/i,.. NAL CAROLINA CARPORTS, INC. 3ENERIC PLANS FOR USE IN THE STATE OF FLORIDA wm 61/05/2021 NECHTMENGINEERING. °"" mkb "" NTS AND 7ESNMG, Inc- ofiemcnad oEurEasar�u.B1V=a10vra.gumvwmuus�o0=e lb Km xa G21001 Cff0`1N4°°'2ie`00°0m ­'�TB SHEET 4 OF 6 2"x2"x2" 16 GA ANGLE CLIP SECURE TO ROST AND RAFTER WITH (4).#12-14x 3/4" SDF's, (2) ON BOTTOM, (2jON SIDE OR 2"x4" 16 GA PLATE SECURE TO EACH SIDE OF TS END POST POST/RAFTER CONNECTION WITH,(4) #12-14 x 3W'SDF's; a (2) ON POST, (2) ON RAFTER END POST/RAFTER CONN. DETAIL Not To Scale 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3W SDFs (2).ON TOP; (2) ON SIDE RAFTER POST 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14.x'3W SDF's, (2) ON TOP, (2) ON BOTTOM TS GABLE RAIL GABLE RAIL TO RAFTER POST Sya� o ScaNNECTION DETAIL 2-1/4" FOR. 12 GA FRAMING 2-1/2" FOR 16 GAUGE U-CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14 x 3/4" SDF'S AT EACH END (4 PER BRACE) BRACE SECTION Not To Scale NIPPLE DBL. HE -S,NIPPLE =ACH WITH x 3W LUNG FASTENERS GA TS POST (-,-�, .RAFTER POST/DBL. HEADER DETAIL Not To Shale 1-1/2" x 1-112" x.2" 16 GA CLIP ANGLE SECURE TO, RAFTER POST -AND GABLE RAIL WITH (4)'#12=14x3/4"-SI TORAND'BOTTOM y 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3W SDF's, (2) ON TOP,,(2) ON BOTTOM 6" LONG TS NIPPLE SECURE RAFTER AND POST TO NIPPLE WITH (4) #12-14 x 314" SELF -DRILLING FASTENERS i RAFTER POST 1FTER.POST NG TS NIPPLE IRE WITH (4) #12-14 x.3(4" -DRILLING FASTENERS � DOUBLETS HEADER NIPPLE TO DBL. HDR. r�RAFTER POST/HEADER DETAIL Not To Scale NIPPLE TO 3/16" RAFTER / RAFTER 12" LONG TS NIPPLE. SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDFs, 24" 16 GA U-CHANNEL BRACE (5 TO T POST) 48" 16 GA U-CHANNEL BRACE (8' T0;14! POST) GABLE RAIL BRACE ANGLE -SHALL BE MIN. 45- TOWAX: 60' FROM HORIZONTAL GABLE RAIL TO RAFTER POST �� COfVNECTION DETAIL l � �% Nol To Scale TS LEG POST 14/2" 18GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x'3W SDI TS SPACED NOT MORE THAN 48" O.C. 26 GA. METAL -ROOF PANEL I TS BASE RAIL RAFTER ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) Not To Scale 6" LONG TS NIPPLE SECURE WITH (4) #12-14 x,3/4" SDF's TS RAFTER POST SIDE, EXTENSION 12, RAFTER/POST DETAIL Not To Scale CODE CO PLMNC 6,Ma LUCIE COUNTY BQCC TS LEG POST POSTS -"-I V-4" I - TYPICAL FLOOD VENT FRAMING PLAN NOT TO SCALE 6" LONG TS NIPPLE SECURE EACH WITH (4) #12-14 x 3/4' SELF -DRILLING FASTENERS 12 GA TS POST RAIL 3/16" NIPPLETO BASE RAIL RAFTER POSUBASE BASE RAIL CONNECTION DETAIL v Not To Scale TS RAFTERPOST 27x4" 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF- POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" SDF's; (2) ON POST, (2) ON RAFTER _,-TS LEAN-TO RAFTER 2"x2"x2" 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 3/4" SDF's, (2), ON RAFTER; (2) ON POST �P02�STL/ LEAN-TORAFTER CONN. DETAIL FILE COPY \ H �� ��.• oGENSF'C'SJ.�. BEC1JT0L CNGINWpRMMD TESTING`, -I 605 WEST NEW YORK AVENUE DELAMi P5ORIDA 32720 - •, i _ 84 1' Max. i N.� —1 Thomas Beotl1ol, \� Florida L(cense?�lo. \ /�f)III1110 SEE GENERAL NOTE ,No. 12, SHEET 1 OF 6. CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA AUSECIITOL ENGINEERING mxe AND TES771NG, Ina o.b. ft cu.a+v�a ru �umw,own,o�moew�w�e tp wmr aAm�mea,raaa"oDaor "-°` G21001 SHEETS OF;6 ti .c VERTICAL SIDE OPTION GIRT (Typical SEE TYPICAL END WALL OPENINGS POSTIRAFTERIGIRT FRAMING PLAN NOT TO SCALE ^WINGING DOOR 1CTURALHEADER BOX SAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL SIDES TYPICAL SIDE ELEVATION NOT TO SCALE" ROLL -UP DOOR SWINGING DOOR (As applicable) , (As applicable) TYPICAL END ELEVATION NOT TO SCALE GIRTS (Typical) 1-112" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48" O:C. rOPENING FOR SWINGING DOOR WITH NONSTRUCTURAL HEADER TF- 5 4 SEE TABLE 1 SHEET 1 OF 6 & s 5 3 ci = o, g v o s 5 12' MAX. OPENING FOR ROLL -UP DOOR WITH STRUCTURALHEADER 4 4 4 _ 4 4 5 �o 4 3 94"a 3. 4 5 ' OPENING FOR WINDOW WITH NON-STRUCTURALHEADER LENGTH VARIES DEPENDING ON NUMBERAND WINDOW RAIL AND SPACING OF RAFTERS (Also applicable to End Walls)' TYPICAL POST/RAFTERIGIRT FRAMING PLAN NOT TO SCALE BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL SIDES ROLL -UP DOOR SWINGING DOOR (As applicable). (As applicable)_ TYPICAL SIDE ELEVATION NOT TO SCALE 6' TYPICAL END ELEVATION NOT TO SCALE REVIEWED FUHt �a OM A"- ®o FILE COPY R..H O O' BECH�OL ENGINW*IN9WD TESTING; INC. 605 WEtT NEW;YORKAVENUE DELAN9• P=RJDA 32720 — Thomas Bedfb� ��• �� . �` �� Florida Licensee 8