HomeMy WebLinkAbout3712 tanager pl faSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: GRBK GHO Homes, LLC
AGENT: Richard Laventure (Laventure & Associates Inc)
PROPERTY ADDRESS: 3712 Tanager PI Fort Pierce, FL 34982
APPLICATION #:AP1581136
PERMIT #:56-SF-1972751
DOCUMENT # : FI 1716440
DATE PAID.09/28/2020
FEE PAID:545.00
RECEIPT #:56-PID-4692202
LOT: 20
SUBDIVISION:
BLOCK:
Estates of Longwood ID#: 2433-502-0020-000-3
CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH
STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [11 1050.00 [21
[ ] [271
SURFACE WATER
FT
[ ] [021
TANK MATERIAL Polypropylene
[ ] [281
DITCHES 15
FT
[ ] [031
OUTLET DEVICE
[ ] [291
PRIVATE WELLS 100
FT
[ ] [041
MULTI -CHAMBERED [ Y N ]
[ ] [30]
PUBLIC WELLS
FT
[ ] [05]
OUTLET FILTER Polylok PL-68
[ ] [311
IRRIGATION WELLS
FT
[ ] [061
LEGEND 1. 70-156-10DC3 2.
[ ] [32]
POTABLE WATER 34
FT
[ ] [07]
WATERTIGHT
[ ] [331
BUILDING FOUNDATIONS 6
FT
[ ] [081
LEVEL
[ ] [34]
PROPERTY LINES 15
FT
[ ] [09]
DEPTH TO LID
[ ] [351
OTHER
FT
DRAINFIELD
INSTALLATION
FILLED / MOUND SYSTEM
[ ] [10]
AREA [1] 679 [2] SQFT
[ ] [361
DRAINFIELD COVER
[ ] [111
DISTRIBUTION BOX HEADER X
[ ] [37]
SHOULDERS
[ ] [12]
NUMBER OF DRAINLINES 1. 6.00 2.
[ ] [38]
SLOPES
[ ] [13]
DRAINLINE SEPARATION
[ ] [391
STABILIZATION 10/15/2021
[ ] [141
DRAINLINE SLOPE
[ ] [15]
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [161
ELEVATION [ ABOVE / BELOW ]BM 12.00
[ ] [40]
UNOBSTRUCTED AREA
[ ] [171
SYSTEM LOCATION
[ ] [411
STORMWATER RUNOFF
[ ] [18]
DOSING PUMPS
[ ] [421
ALARMS
[ ] [191
AGGREGATE SIZE
[ ] [43]
MAINTENANCE AGREEMENT
[ ] (201
AGGREGATE EXCESSIVE FINES
[ ] [441
BUILDING AREA
[ ] [211
AGGREGATE DEPTH
[ ] [451
LOCATION CONFORMS WITH SITE PLAN
[ [46]
FINAL SITE GNG RADI
FILL
/ EXCAVATION MATERIAL
]
[ ] [221
FILL AMOUNT
[ ] [47]
CONTRACTOR Mike Stuhr (Ashton)
[ ] [231
FILL TEXTURE
[ ] [48]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [24]
EXCAVATION DEPTH
ABANDONMENT
[ ] [251
AREA REPLACED
[ ] [491
TANK PUMPED
[ ] [261
REPLACEMENT MATERIAL
[ ] (50]
TANK CRUSHED & FILLED
Comments:
Comments are on page 2.
CONSTRUCTION I APPROVED / DISAPPROVED ]
!/ St. Lucie CHD
I e yi (Florida Department of He
FINAL SYSTEM [ APPROVED / DISAPPROVED ]: / St. Lucie CHD
Environmental Specialist II rian J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v 1.0.1 A131581136 EID1972751
DATE: nS/1 1 /?nq1
DATE: 10/15/2021
Page 2 of 3
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION #:AP1581136
PERMIT #:56-SF-1972751
DOCUMENT #: F11716440
DATE PAID . 09/28/2020
FEE PAID:545.00
RECEIPT #:56-PID-4692202
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, filter, and 6x10 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final
nspection for gutters, ditch/swale setback, mound system, depth of cover, and final site grading.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3