HomeMy WebLinkAboutRevisions :.(OFFICE USE ONLY: 1 II --
DATE FILED: �c��1 �' \ PERMIT#
REVISION FEE: RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION RECEIVED
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652 OCT 14 2021
(772)462.1553
APPLICATION FOR BUILDING PERMIT REVISIO sr. Lucie county, Permitting
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
-- oa �4,
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
DUE TO EQUIPMENT SHORTAGES,-TRADE TO INSTALL TRANE AIR CONDITIONER ILO CARRIER
CONTRACTOR INFORMATION: FILE Copy
STATE of FL REG./CERT. #: CRC1330146 ST. LUCIE CO CERT. #: 29179
BUSINESS NAME: ADAMS HOMES OF NORTHWEST FLORIDA, INC.
QUALIFIERS NAME: WILLIAM BRYAN ADAMS
ADDRESS: 3000 GULF BREEZE PARKWAY
CITY: GULF BREEZE STATE: FL ZIP: 32563
PHONE (DAYTIME): 772-905-8394 FAX: 772-905-8511
OWNERMUILDER INFORMATION:
NAME: ADAMS HOMES OF NORTHWEST FLORIDA,INC.
ADDRESS:3000 GULF BREEZE PARKWAY
CITY: GULF BREEZE STATE: FL ZIP: 32563
PHONE(DAYTIME: 772-905-8394 FAX: 772-905-8511
ARCIHTECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
SLCCC: 9/23/09 w"'EVI ' l
Revised 06/30/17 ON
RECEIVED
OCT 14 2021
FORM R405-2020
ST. Lucie C i
FLORIDA ENERGY EFFICIENCY CODE FOR BUIL ION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 20 Block 5 Waterstone 1820 DGR Builder Name: ADAMS HOMES
Street: 5377 San Benedetto Place Permit Office:
City,State,Zip: Fort Pierce,FL,34951 Permit Number:
Owner: Jurisdic 0
Design Location: FL,ST_LUCIE_CO_INTL County: ikFIfa im
1. New construction or existing New(From Plans) 10. Wall TypeV120.0 sq jn tiV50.
r
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.10 ftz
b.Frame-Wood,Adjacent R=13.0 270.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Types (1900.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1820.00 ft2
6. Conditioned floor area above grade(ft2) 1820 b.Knee Wall(Vented) R=19.0 80.00 ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
7. Windows(237.2 sqft.) Description Area 12.Ducts R ft2
a. U-Factor: Dbl,U=0.33 168.74 ft2 a.Sup:Attic,Ret:Main,AH: Main 6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.33 32.38 ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21 a.Central Unit 34.8 SEER:16.00
c. U-Factor: Dbl,U=0.33 18.33 ftz -
SHGC: SHGC=0.31 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 4.181 ft. a.Electric Heat Pur p� L ®�3 HSPF:9.00
Area Weighted Average SHGC: 0.269
8. Skylights Area
c. U-Factor:(AVG) N/A ftz 15.Hot water systems
SHGC(AVG): N/A a. Electric Cap:40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area EF:0.940
a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features
b.N/A R= ft2 None
c. N/A R= ft2 16.Credits Pstat
Glass/Floor Area: 0.130 Total Proposed Modified Loads: 59.67 PASS
Total Baseline Loads: 64.94
I hereby certify that the plans and specifications covered by Review of the plans andTHE.Spq�
this calculation are in co once with the Flor' a Energy specifications covered by this ,Q�'' _ per
Code. calculation indicates compliance �j`�' ii, __~.'�;.��.
with the Florida Energy Code. ti ,+�rnc.'v, `"�,�O
PREPARED BY: Before construction is completed
DATE: 9-98-9091 Cnrrina MahPy this building will be inspected for ; " a
compliance with Section 553.908
I hereby certify that this building, as de si necl isJ compliance Florida Statutes.
with the Florida -
9Y-Gos1e .___-- �
OWNER/AGENT: ( BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT_
PROJECT
Title: Lot 20 Block 5 Waterstone 18 Bedrooms: 4 Address Type: Street Address
Building Type: User, Conditioned Area: 1820 Lot# 20
Owner Name: Total Stories: 1 Block/Subdivision: Waterstone
#of Units: 1 Worst Case: No PlatBook:
Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5377 San Benedetto PI
Permit Office: Cross Ventilation: No County: St. Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce,
Family Type: Detached FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST LUCIE CO INTL FL VERO BEACH MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1820 18200
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 33 ft 0 1820 ftz _--- 0.42 0 0.58
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 2035 ftz 456 ftZ Medium N 0.85 N 0.85 No 0 26.57
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1820 ftZ N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1820 ftZ 0.11 Wood
2 Knee Wall(Vented) Main 19 Batt 80 ftz 0.11 Wood
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 E Exterior Concrete Block-Int Insul Main 4.1 59 0 10 0 . 590.0 ft2 0 0 0.6 0
2 S Exterior Concrete Block-Int Insul Main 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0
3 W Exterior Concrete Block-Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0
4 N Exterior Concrete Block-Int Insul Main 4.1 27 0 10 0 270.0 ft2 0 0.6 0
5 - Garage Frame-Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0
6 S Exterior Concrete Block-Int Insul Main 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0
7 N Exterior Concrete Block-Int Insul Main 4.1 13 0 10 0 130.0 ft2 0 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S Insulated Main None .25 3 6 8 20 ft2
2 - Wood Main None .25 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5
2 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5
3 S 6 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 9 ft 0 in 0 ft 6 in None None
4 S 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5
5 S 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5
6 S 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5
7 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5
8 N 7 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 12 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5
9 N 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5
10 N 7 Vinyl Low-E Double Yes 0.33- 0.23 N 32.4 ft2 12 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 396 ft2 396 ft2 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50
1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split Singl HSPF:9 33 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Sing[ SEER:16 34.8 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
----Supply---- Return--- Air, CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar [ ]A r Ma rj Jun ri
Jul rl
Au rl
Se Oct Nov 1 DecHeatin lX Jan X Feb X Mar [ ]APr May Jun Jul AuSep Oct Nov X]Dec
Ventin [ Jan [ ]Feb XMar [X]A r ( Ma Jun Jul Aug Se [X Oct X Nov [ ]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 .78 78 78 78 78 78 78 . 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 4
FORM R405-2020
a
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index,the more efficient the home.
5377 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1850.00 ftZ
b.Frame-Wood,Adjacent R=13.0 270.00 ftZ
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Number of Bedrooms 4 d.N/A R= ftZ
5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1820.00 ftZ
6. Conditioned floor area(ftZ) 1820 b.Knee Wall(Vented) R=19.0 80.00 ftZ
7. Windows" Description Area c.N/A R= ftZ
a. U-Factor: Dbl,U=0.33 168.74 ftZ 12.Ducts,location&insulation level R ftZ
a.Sup:Attic, Ret:Main,AH:Main 6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.33 32.38 ftZ
SHGC: SHGC=0.21 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.33 18.33 ftZ a.Central Unit 34.8 SEER:16.00
SHGC: SHGC=0.31
d. U-Factor: other(see details) 17.78 ftZ 14.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Heat Pump 33.0 HSPF:9.00
Area Weighted Average Overhang Depth: 4.181 ft.
Area Weighted Average SHGC: 0.269
8. Skylights Description Area 15.Hot water systems
a. U-Factor(AVG): N/A ftZ a. Electric Cap:40 gallons
EF:0.94
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ftZ Credits(Performance method) Pstat
b.N/A R= ftZ
c.N/A R= ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building 1xE ST
Construction through the above energy saving features which will be installed (or exceeded) Q� = Apo
in this home before final inspection. Otherwise,-a-ne-w EPL Display Card will be completed
based on installed Code comb' nt features. ��' y /ir;
d
Builder Signature- - Date: Y.a
Address of New Home: City/FL Zip:
CIO
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
E 722-021
FORM�405-2020 OCT 1
ST. Lucie County, Permitting
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification (usually fourpages/may be greater)
❑ Energy Performance Level(EPL) Display Card(one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements(five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.9 -one page)
❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
2020 Duct Leakage Test Report-Performance Method(usually one page)
9/28/2021 1:45:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 5377 San Benedetto Place Permit Number:
Fort Pierce,FL,34951
MANDATORY REQUIREMENTS -See individual code sections for full details.
i
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
❑ (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems, if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS -' (Continued)
R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with.a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 Controls. SECTION R403 SYSTEMS
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,
including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be tapedor otherwise
sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire
system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where Qn=
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55°F(I YC)shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are
installed,they shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall
be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5
It
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60oC).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of
combustion types of service water-heating systems to be turned off.
R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TMA,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical
ventilation,the air handler shall be powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or RA
otherwise.
R403.7 Heating and cooling equipment.
❑ R403.7.1 Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the
outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other
factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU
(CFM) (CFM/WATT) (CFM)
HRV or ERV Any 1.2 cfm/watt Any
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
El
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
❑ intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C).
❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5
C
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
u the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
R403.13 Dehumidifiers(Mandatory If installed,a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
❑ R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 5
2020-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a
Project Name: Lot 20 Block 5 Waterstone 1820 DGR Builder Name: ADAMS HOMES
Street: 5377 San Benedetto Place Permit Office:
City,State,Zip: Fort Pierce,FL,34951 Permit Number: Y
Owner: Jurisdiction: 661000 ul
Design Location: FL,ST_LUCIE_CO_INTL c�
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to 9
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overiapping.joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Pyt,-.nri behind D012ina and Wring,
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
hptwppn f 0 re sprinkler cover plates and walls or reilinas
a. In addition,inspection of log walls shall be in accordance with the provisions of[CC-400.
9/28/2021 1:45 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000 Permit#:
Job Information
Builder: ADAMS HOMES Community: Lot: NA
Address: 5377 San Benedetto Place
City: Fort Pierce State: FL Zip: 34951
Air Leakage-Test'ResUlts. Passing resuits must meet.either' Performance; Prescriptive, or ERI Method
0 'PRESCRIPTIVE METHOD-,The building or dwelling unit shall be tested and verifie6as having an air,leakage rate of not,exceeding 7 air
changes per hour'at a pressure of 0.2 inch w:g.-'(50:Pascals)in Climate Zones 1 and 2.
O 'PERFORMANCE or ERI METHOD=The build ing.ocdwelliing unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50)value,as shown on Form R405 2020{Performance)or R406 2020'.(ERI);section labeled'as infiltration,sub-section ACH50
ACH(50)specified on Form R465-2020-Energy Calc(Performance)orrR406-2020(ERI): 7.000
x 60 _ 18200 — Method for calculating buildinq volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
1-1
PASS •Code software calculated
When ACH(50)is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control.
measures.
3. Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: Issuing Authority:
9/28/2021 1:45:28 PM EnergyGaugeOO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
DEL-AIR
Manual S Compliance Report Job: Lot20 Block Waterstone...
Date:
HUM•wx coxnmoxac Entire House By: DCs
DEL AIR HTG,A/C& REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
Project
For: ADAMS HOMES
5377 San Benedetto Place,Fort Pierce,FL 34951
Cooling Equipment
Design Conditions
Outdoor design DB: 90.4OF Sensible gain: 25681 Btuh Entering coil DB: 76.4°F
Outdoor design WB: 77.4OF Latentgain: 4767 Btuh Entering coil WB: 63.2°F
Indoor design DB: 75.0 OF Total gain: 30447 Btuh
Indoor RH: 50% Estimated airflow: 1160 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Trane Model: 4TWR6036H1+TEM6AOC36H31++TDR
Actual airflow: 1160 cfm
Sensible capacity: 29024 Btuh 113%of load
Latent capacity: 5037 Btuh 106%of load
Total capacity: 34060 Btuh 112%of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 41.0°F Heat loss: 28559 Btuh Entering coil DB: 69.5°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Trane Model: 4TWR6036H1+TEM6AOC36H31++TDR
Actual airflow: 1160 cfm
Output capacity: 29510 Btuh 103%of load Capacity balance: 37 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elecstrip
Manufacturer: Model:
Actual airflow: 1160 cfm
Output capacity: 7.9 kW 94%of load Temp.rise: 21 OF
Meets all requirements ofACCA Manual S.
Wright9Oft® 2021-Sep-2813.43,07
��••�, _�•e- �mroM R ght-Sute®Uriversa12021 21.0.07 RSU24004 Page 1
ACCK 820DGR-ot2OBlk5Waterstoriel82ODGR_TrarioAlt.rLp Calc=W8 Front Door faces:S
DEL-AIR Component Constructions D °t2°B'°°k5waterst°"e••.
HMMG•AIR coNmnOroNG Entire House By. oCs
DEL AIR HTG,A/C& REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM
Project • •
For: ADAMS HOMES
5377 San Benedetto Place,Fort Pierce,FL 34951
Design Conditions
Location: Indoor: Heating Cooling
St Lucie Co Intl,FL,US Indoor temperature(OF) 70 75
Elevation: 26 ft Design TD(OF) 29 15
Latitude: 28 ON Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr4b) 2.4 56.9
Dry bulb(°F) 41 90 Infiltration:
Daily range(OF) - 15 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions or Area U-value Insul R Htg HTM Loss Cig HTM Gain
ft' BtuWftt"F ftz'F/Btuh BtuWft� Btuh BMW Btuh
Walls
16B-19ad:Knee wall,asphalt shingles roof mat,r-19 kw ins,1/2"gypsum n 20 0.049 19.0 1.42 28 2.59 52
board int fnsh a 20 0.049 19.0 1.42 28 2.59 52
s 20 0.049 . 19.0 1.42 28 2.59 52
W 20 0.049 19.0 1.42 28 2.59 52
all 80 0.049 19.0 1.42 114 2.59 207
Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board int fnsh n 317 0.201 4.1 5.83 1846 4.06 1286
e 534 0.201 4.1 5.83 3113 4.06 2168
s 129 0.201 4.1 5.83 751 4.06 523
W 611 0.201 4.1 5.83 3561 4.06 2481
all 1591 0.201 4.1 5.83 9272 4.06 6458
Partitions
12C-Osw:Frm wall,1/2"gyp.bd ext,r-13 cav ins,1/2"gypsum board int 270 0.091 13.0 2.64 713 1.31 354
fnsh,2"x4"wood frm,16"o.c.stud
Windows
1 OC-v:2 glazing,clr ,low-e outr,air gas,vnl fnn mat,dr ,innr,1/4"gap,1/8" n 18 0.550 0 16.0 285 16.2 289
thk;NFRC rated(SHGC=0.70);12 ft overhang(6.7 ft window ht,0.5 ft
sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" n 33 0.330 0 9.57 313 8.52 279
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 ft overhang a 49 0.330 0 9.57 469 22.4 1096
(5.3 ft Window ht,0.8 ft sep.);6.67 ft head ht w 49 0.330 0 9.57 469 22.4 1096
all 131 0.330 0 9.57 1251 18.9 2470
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" n 33 0.330 0 9.57 313 8.52 279
thk;NFRC rated(SHGC=0.23);50%drapes,medium;12 ft overhang(5.3
ft window ht,0.25 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" e 7 0.330 0 9.57 66 21.8 151
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 ft overhang
(3.2 ft window ht,0.8 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,'air gas,vnl frm mat,clr innr,1/4"gap,1/8" s 33 0.330 0 9.57 . 313 8.22 269
thk;NFRC rated(SHGC=0.21);50%drapes,medium;1.3 ft overhang
(5.3 ft window ht,0.83 ft sep.);6.67 ft head ht
wrilghtsaf - 2021-Sep-2813:43:07
.w.,.k•.�,,..•w- � Right-Stite®Uriversal202121.0.07RSU24004 Pagel
820DGRLot20BIk5Waterstone1820DGR TrarieAltnp Calc=W8 Front Door faces:S
2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" s 5 0.330 0 9.57 48 11.6 58
thk;NFRC rated(SHGC=0.31);9 ft overhang(1 ft window ht,0.5 ft sep.);
6.67 ft head ht
2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr, 1/4"gap,1/8" s 13 0.330 0 9.57 128 9.72 130
thk;NFRC rated(SHGC=0.31);50%drapes,medium;9 ft overhang(6.7
ft window ht,2 ft sep.);6.67 ft head ht
Doors
11 J0:Door,mtl fbrgl type s 20 0.600 6.3 17.4 350 17.6 353
Ceilings
1 6B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 1835 0.032 30.0 0.93 1703 1.69 3100
gypsum board int fnsh
Floors
22A-tpl:Bg floor,light dry soil,on grade depth 212 0.989 0 28.7 6080 0 0
� -Pk WPight30ft- 2021-Sep-2813:43:07
.u..t•re.,..,.„.�. m, RigM-Sute®Uriversal202121.0.07RSU24004 Paget
820DGR\Lot2OBlk5Waterstoriel82ODGR TrareAltrLp Calc=MJ8 FroMDoorfaces:S
4. � DEL-AIR Project Summary Job.
: Lot z°Block svuarelscone...
HEATING•AIR CONRRIONING Entire House By: oCs
DEL AIR HTG,A/C& REFRIG.INC
531 GODISCOWAYSANFORD,FL32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM
Project • •
For: ADAMS HOMES
5377 San Benedetto Place,Fort Pierce,FL 34951
Notes: JA8-18-15
'Change to 3.0 ton 2/16/16 S.Finch
RVSD 12/7/16 JA
L.S. 1-13-21 VWK
Design Information
Weather: St Lucie Co Intl,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 41 OF Outside db 90 OF
Inside db 70 OF Inside db .75 OF
Design TD 29 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 57 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
_ Structure 24339 Btuh Structure 19904_ Btuh
Ducts 4220 Btuh Ducts 5777 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification. 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 28559.Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 25681 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3364 Btuh
Ducts 1403 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1820 1820 Equipment latent load 4767 Btuh
Volume(ft3) 18350 18350
Air Changesmour 0.38 0.20 Equipment Total Load(Sen+Lat) 30447 Btuh
Equiv.AVF(cfm) 116 61 Req.total capacity at 0.75 SHR 2.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade TRANE Trade TRANE
Model 4TWR6036H1 Cond 4TWR6036H1
AHRI ref 7562981 Coil TEM6AOC36H31++TDR
AHRI ref 7562981
Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER
Heating input Sensible cooling 26100 Btuh
Heating output 33000 Btuh @ 47OF Latent cooling 8700 Btuh
Temperature rise 26 OF Total cooling 34800 Btuh
Actual airflow 1160 cfm Actual airflow 1160 cfm
Airflowfactor 0.041 cfm/Btuh Airflowfactor 0.045 cfm/Btuh
Static pressure 0.40 in H2O Static pressure 0.40 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point=37 OF
Iln ut=p8 kW, Output=26788 Btuh,100 AF.0 E
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ -Pk- wrightsoft' 2021-Sep-2813A3:07
�� Right-SLite@Uriversal 202l 2l.O.O7 RSU24004 Pagel
820DGRLot2OBlk5waterstoreIB20DGR TrarigAltnp Calc=W8 Frorl Door faces:S
DEL--AIR Right-M Worksheet Job: Lot 20 Block 5 Waterstone 18...
rrtnmrc•nm cormmoraec Entire House Date:
DEL AIR KrG,A/C&REFRIG. INC By. DCS
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
1 Room name Entire House BDRM2
2 Exposed wall 212.0 ft 36.0 ft
3 Room height 10.0 ft d 10.0 ft heaV000l
4 Room dimensions 13.0 ' x 13.0 ft
5 Room area 1835.0 ft2 169.0 ft2
Ty Construction U-value Or HTM Area 02) Load Area (ftz) Load
number (Btu"-fl (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 1613-19ad 0.049 n 1.42 259 20 20 28 52 0 0 0 0
Blk vall,stucco eM 0.201 n 5.83 4.06 400 317 1846 1286 130 114 663 461
10C-v 0550 n 15.95 1620 18 0 285 289 0 0 0 0
2A-2ov 0.330 n 9.57 852 33 0 313 279 16 0 156 139
11 2A-2ov 0230 n 9.57_ 852 33 0 313 279 0 0 0 0
W 166-19ad 0.049 a 1 A2 259 20 20 28 52 0 0 0 0
W Blk veil,stucco eM 0.201 a 5.83 4.06 590 534 3113 2168 100 100 583 406
G 2A-2ov 0.330 a 9.57 21.79 7 1 66 151 0 0 0 0
2A-2ov 0.330 a 9.57 22.35 49 3 469 1096 0 0 __ 0 0
W, 1613-19ad__ .. 0.049 s 1A2 259 20 20 28 52 0 0 0 0
Blk vall,stucco ext 0.201 s 5.83 4.06 200 129 751 523 0 0 0 0
2A-2ov 0.330 s 957 822 33 33 313 269 0 0 0 0
vN
2B-2fv 0.330 s 9.57 11.58 5 5 48 58 0 0 0 0
2B-2fv 0.330 s 957 9.72 13 13 128 130 0 0 0 0
11J0 0.600 s 17AO 1758 20 20 350 353 0 0 _ 0 0
W 1613-19ad 0.049 w 1.42 259 20 20 28 52 0 0 0 0
Blk vtdl,stuaro ext 0.201 w 5.83 4.06 660 611 3561 2481 130 130 758 528
t-G 2A-2ov 0.330 w 9,57 22.35 49 3 469 1096 0 0 0 0
P 12C-0sw 0.091 2.64 121 270 270 713 354 0 0 0 0
C 166-30ad 0.032 0.93 1.69 1835 1835 1703 3100 169 169 157 286
F 22A-tp1 0.989 28.68 0.00 1835 212 6080 0 169 36 1033 0
6 c)AED excursion 0 -103
Envelope loss/gain 20635 14119 3349 1718
12 a) Infiltration 3704 1035 691 193
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants Ca) 230 5 1150 0 0
Appliancestother 3600 300
Subtotal(lines 6 to 13) 24339 19904 4040 2211
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 24339 19904 4040 2211
1151 Dud loads 1179/6 29% 4220 5777 170% 29%1 700 642
Total room load 28559 25681 4740 2852
Air required(cfm) 1160 1160 193 129
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-P�F wrightsolFt- 2021-Sep-2813.,43:07
Right-SUteOUriversal2021 21.0.07 RSU24004 Page 1
820DGR\Lot2OBlk5Waterstorx;182ODGR_TraneAlt.rLp Calc=MJB FrontDoorfaces:S
DEL-AIR Right-M Worksheet Job: Lot 20 Block 5 Waterston 18...
1if11TMG-nm coxnmoxmc Entire House Date:
By. DCS
DEL AIR HTG, A/C&REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
1 Room name BATH 2 BDRM3
2 Exposed wall 6.0 ft 13.0 ft
3 Room height 10.0 It heattcool 10.0 ft heat/cool
4 Room dimensions 13.0 x 6.0 It 13.0 x 13.0 It
5 Room area 78.0 ft2 169.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/ftz-`F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 1613-19ad - 0049 n 1A2 259 0 0 _0 0 0 0 0 0
Blkvdl,stucco ext 0.201 n 5.83 4.06 0 0 0 0 0 0 0 0
1OC-v 0.550 n 15.95 1620 0 0 0 0 0 0 0 0
2A-2ov 0.330 n 957 8.52 0 0 0 0 0 0 0 0
11 2A-2ov 0,330 n 957 852 _ 0 _ 0 0 0 0 0 0 0
W 166-19ad 0.649 a 1.42 259 0_ 0 0 0 0 0 _ 0 0
Vt/ Blk v,ell,stucco ext 0.201 a 5.83 4.06 0 0 0 0 0 0 0 0
G 2A-2ov 0.330 e 957 21.79 0 0 0 0 0 0 0 0
2A-2ov 0330 a 9.57 _ _22.35 0 _ 0 0 0 0 0 0 0
W 16B-19ad 0.049 s 1.42 259 0 0 0 0 0 0 0 0
Blk well,stucco e)d 0.201 s 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0230 s 9.57 822 0 0 0 0 0 0 0 0
2B-2fv 0.330 s 9.57 11.58 0 0 0 0 0 0 0 0
2B-2fv 0.330 s 957 9.72 0 0 0 0 0 0 0 0
11J0 0.600 s 17AO _ 1758 0 0 0 0 0 0 0 0
W 1613-19ad O.o49 w 1.42 259 0 0 0 0 0 0 0 0
Blk wall,slucao eM 0.201 w 5.83 4.06 60 60 350 244 130 114 663 461
t-G 2A-2ov 0.330 w 9.57 2235 0 0 0 0 16 1 156 365
P - 12C-Osw ,._ 0.091 2.64 121 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 0.93 _ 1.69 78 78 72 132 169 169 157 286
F 22A-tpl 0.989 28.68 0.00 78 6 172 0 169 13 373 0
6 c)AED excursion -18 152
Envelope loss/gain 594 357 1349 1264
12 a) Infiltration 115 32 249 70
b) Roam ventilation 0 0 0 0
13 Internal gains: Oocupantspa 230 0 0 0 0
Applianoes/other 0 1 1300
Subtotal(lines 6 to 13) 709 389 1598 1634
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 709 389 1598 1634
15 Duct loads 117% 29% 123 113 17% 29% 277 474
Total room load 832 503 1875 2108
Air required(dm) 34 23 76 95
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- - �*� wrigF�tsoft- 2021-Sep-2813:4307
""'-" ""' Bight-Suite®Uriversal202121.0.07RSU24004 Paget
820DGR�Lot2OBlk5Waterstorel82ODGR_TraneAlLnQ Calc=WB FrontDoorfaces:S
`WEL--AIR Right-M Worksheet Job: Lot 20 Block 5 Waterstone 18...
Hf 11G-AMcotmmmmNc Entire House Date:
DEL AIR HTG, A/C&REFRIG. INC By: DCS
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
1 Room name DINING/FOYER DEN/BDRM4
2 Exposed wall 25.0 ft 31.0 It
3 Room height 10.0 It heat(000l 10.0 It heat/cool
4 Room dimensions 1.0 x 276.0 ft 13.0 x 13.0 It
5 Room area 276.0 ft2 169.0 ft2
Ty Construction U-value Or HTM Area 02) Load Area (ft2) Load
number (Btuh/ftz`l (Btu"2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/PB Heat Cool Gross W/s Heat Cool
6 W 1613-19ad am n 1.42 _ 259 0 0 0 0 0 0 0 0
Blk Kell,stucco ext 0.201 n 5.83 4.06 0 0 0 0 0 0 0 0
1OC-v 0550 n 15.95 1620 0 0 0 0 0 0 0 0
2A-2ov 0.330 n 957 852 0 0 0 0 0 0 0 0
11 2A-2ov 0.330 n 9.57 852 0 0 0 0 0 0 0 0
W 16B-19ad 0.049 a 1A2 259 0 0 0 0 0 0 0 0
y/ Blk wall,stucco ext 0.201 a 5B3 4.06 0 0 0 0 50 50 291 203
I�-CG 2A-2ov 0.330 e 957 21.79 0 0 0 0 0 0 0 0
2A-2ov 0230 a 9.57 2225 0 0 0 0 0 0 0 0
W 1613-19ad 0.049 s 1.42 259 0 0 0 0 0 0 0 0
Blk Kell,stucco eM 0.201 s 5.83 4.06 70 32 184 128 130 97 567 395
2A-2ov 0,330 s 9.57 822 0 0 0 0 33 33 313 269
2B-2fv 0.330 s 957 11.58 5 5 48 58 0 0 0 0
2B-2fv 0230 s 957 9.72 13 13 128 130 0 0 0 0
11JO 0.600 s 17AO 1758 20 20 350 353 0 0 0 0
W 1613-19ad 0.049 w 1.42 259 0 0 0 0 0 0 0 0
Blk vol[,stucco ext 0.201 w 5.83 4.06 110 77 451 314 130 130 758 528
t-_ G 2A-2ov 0230 w 9.57 22.35 33 2 313 730 0 0 0 0
P 12C-Osw 0.091 2.64 121 70 70 185 92 0 0 0 0
C 1613-30ad 0.032 0.93 1.69 276 276 256 466 169 169 157 286
F 22A-lpl 0.989 28.68 0.00 276 25 717 0 169 31 889 0
6 c)AED excursion 267 -95
Envelope loss/gain 2631 2539 2975 1585
12 a) Infiltration 345 97 595 166
b) Room ventilation 0 0 0 0
13 Internal gains: Occupantspa 230 1 230 0 0
Appliancestother 0 300
Subtotal(lines 6 to 13) 2976 2866 3570 2051
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2976 2866 3570 2051
15 1 Dud loads 117% 29%1 516 832 17 X 290/6 619 595
Total room load 3492 3698 4189 2647
Air required(cfm) 142 167 170 120
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-f'�F wrigF�tsoTt-AC�A Right-Su 2021-Sep-2813:43:07te®Uriversal 2021 21.0.07 RSU24004 Page 3
820DGR�Lot2OBlk5Waterstoml82ODGR_TraneAlLrLQ Calc=MJ8 FrontDoorfaces:S
`1 DEL-AIR Right-JO Worksheet Job: Lot 20 Block 5 Waterstone 18...
Kmwe.=cormmumc Entire House Date:
DEL AIR HTG, A/C&REFRIG. INC By: DCS
531 CODISCO WAY SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
1 Room name FAMILY RM MSTR BDRM
2 Exposed wall 13.0 It 41.0 ft
3 Room height 10.0 ft heaUmol 10.0 it heaUmol
4 Room dimensions 13.0 x 22.0 it 14.0 x 17.0 ft
5 Room area 286.0 ft2 238.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Bluh/ftz-�q (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 1.42, _' 0.
Blk mall,stucco ext 0.201 n 5.83 4.06 130 79 463 323 140 124 721 562
10C-v 0550 n 15.95 1620 18 0 285 289 0 0 0 0
2A-2ov 0.330 n 957 852 0 0 0 0 16 0 156 139
11 2A-2ov 0230 n 957 852 33 0 313 279 0 0 0 0
16B 19ad���_- ^ _ 0.049__e_ -- 1A2 259 _- _20 _ 28 52__.____ 0__---_0-_� 0 ___ 0
UI/ Blk vall,stucco ext 0.201 a 5.83 4.06 0 0 0 0 170 154 896 -624
2A-2ov 0230 a 957 21.79 0 0 0 0 0 0 0 0
2A 2ov _- 0230 e_.. 9.57 22.35 0 r 0 0 0 _ 16�.-- 1. _ 156 365
W 16B 19ad - _ ---0.049,_s_. _ -4, 20_ - -20 =28 52_ =-�0 -- - - 0 _. .__.0
__2,59
Blk wall,stucco e/d 0.201 s 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0.330 s 957 822 0 0 0 0 0 0 0 0
26-21V 0230 s 957 11.58 0 0 0 0 0 0 0 0
26-21v 0230 s 957 9.72 0 0 0 0 0 0 0 0
11J0 0.600 s 17AO 1758 0 0 0 0 0 0 0 0
W -16B-19ad - 0.049. W_. _1.42 2 59___ _._20 --- 20 ____28 -- -52 ... _.. 0 - 3- - 0 0
V�/ Blk%all,stucco eM 0.201 w 5B3 4.06 0 6 0 0 100 100 583 - -'406
-G 2A-2ov 0.330 w 957 22.35 0 0 0 0 0 0 0 0
P 12C Osw _ _ 0.091 2.64-_.._131 _- _._._ 0 -�_0- -,�_9_ __. 0 ___--0
C- _ 16B-30ad------- ----.-0.032 -_. - 0.93._ -_1-69- -- 286- 286 _•-_265- 483 _238_-----238 --221_
_ .402
F- - WI--- -.------.-01289_ _- _ M.68 -_0.00 __286__�_. 13-- --373.._- 0 .-__._238_ 41-----1176- .--- -0
-------------
6 c)AED excursion -119 -130
Envelope loss/gain 1813 1462 3909 2308
12 a) Infiltration 403 113 787 220
b) Roomventilation 0 0 0 0
13 Internal gains: Occupantsr?a 230 3 690 1 230
Appliances/other 1300 600
Subtotal(lines 6to 13) 2216 2564 4696 3358
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal P-216 2564 4696 3358
15 Duct loads 17% 29% 384 744 17% 29% 8141 975
Total room load 2600 3309 5510 4333
Air required(cfm) 106 149 224 196
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
;` -P�1 wr➢gF�tsoit- 2021-Sep-2813.43:07
AMk Right-SuteO Uriversal 2021 21.0.07 RSU24004 Page 4
820DGR1Lot2OBlk5Waterstorie182ODGR_Trar)eAlLrLp Calc=MJ8 FrontDoorfaces:S
DEL-AIR Right-JO Worksheet Job: Lot20 Block Waterston 18...
ufnntts'amCUUrn M Entire House Date:
DEL AIR HTG,A/C&REFRIG. INC By: DCS
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM
1 Room name M BATH M WIC
2 Exposed wall 12D It 0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heaUmol
4 Room dimensions 1.0 x 119.0 ft 7.0 x 7.0 ft
5 Room area 119.0 ft2 49.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh4t2-'q (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/Pi5 Heat Cool
-6 16&19-ad- — ----0.049 -n.-- --1.42- 259
0 0 0
_ - - -
W--_ - _.._ _ -_ ._ .... . _ -- __ _ --_ __ _ 0 _ --0 0 0 0
Blk%dl,stucco ext 0.201 n 5.83 4.06 0 6 -- 0 0 _-_ 0 0 0 0
10C-v 0550 n 15.95 1620 0 0 0 0 0 0 0 0
2A-2ov 0230 n 957 852 0 0 0 0 0 0 0 0
11 2A-2ov 0230 n 957 852 0 0 0 0 0 0 0 0
W--- 16B-19ad__----- _ _ 0,049. e 1.42 __259 --____O 0 _0 - —0 _ _- _ 0 v _ _0 _-_ 0 _ 0
Blk Hell,stucco ext 0.201 a 5.83 4.06 120 113 659 459 0 - 0 0 0
2A-2ov 0230 e 957 21.79 7 1 66 151 0 0 0 0
2A2oy_. _ _. 0230 e- _957, 2225 _.. 0 . _0 ._...__-_0 ----. 0 _. 0_-- ._.-_0_. _0 _0
W . .-_ 16B-19ad_-_ ___- _ _.0.049 -s _ _ 1.42-_-259 _ 0_ _ -. 0 __ _ -0 __ 0---. 0 _
Blk Hell,stucco ext 0.201 s 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0230 s 957 822 0 0 0 0 0 0 0 0
2B-2N 0330 s 957 11.58 0 0 0 0 0 0 0 0
2B-2fv 0230 s 957 9.72 0 0 0 0 0 0 0 0
11J0 __ _ 0.600 s_ _ 1,7AO _ 17.58 _ 0 0 _ 0 0 0 0 0 0
--0,049- w_ 259_ ---- 0 _ -_._ 0 . 0 0 ._ _ ._0 0- _ . 0 _ _ _0
V}/ Blk vall,stucco ext 0.201 w 5.83 4.06 0 0 0 0 0 0 0 0
�--G 2A-2ov 0.330 w 957 2235 0 _ 0 0 0 0 0 0 0
12C-Osw 0 09 1 =- 2.64 _._ .131 - - -
0 _ -0 -0 ., 0 _0 0 _..._0
166 30ad..- - 0.032 0.93.__..1:69 _ 119 _ .__. 119_. ._ 110 .._ _ 201 49 - - 49 45 - - 83
F._ .22A-0p1__.. _._-_-- ----0.989-_._ -- 28.68 0.00- __._.119--.---_12 344
6 c)AED exausion 1 -4
Envelope losstgain 1180 813 45 79
12 a) Infiltration 230 64 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1410 877 45 79
Less external load 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1410 877 45 79
15 Dud loads 17% 29% 245 255 17% 29% 8 23
Total room load 1655 1132 53 102
Air required(cfm) 1 67 51 1 2 5
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-F°&- wr➢gf�tsotrt^ 2021-Sep-2813:43:07
""" """"" Right-Suite®Unversal 2021 21.0.07 RSU24004 Page 5
820DGFNLot2OBlk5Waterstonel82ODGR—TrarioAltnp Calc=MJB FrortDoorfaces:S
DEL-AIR Right-M Worksheet Job: Lot20 Block Waterstone 18...
xFanxc.amcormmcrmic Entire House Date:
DEL AIR HTG,A/C&REFRIG. INC By: DCS
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM
1 Room name KrrCHENMOOK LAUNDRY
2 Exposed wall 29.0 ft 6.0 ft
3 Room height 10.0 It heaV000l 10.0 ft heaVmol
4 Room dimensions 1.0 x 246.0 ft 6.0 x 6.0 ft
5 Room area 246.0 ft2 36.0 ft2
Ty Construction U-value Or HTM Area 2 (ftz) Load
number (Btuh/ft2-fl (Btuh/ft2) or perimeter (ft) (B h) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/R)S Heat Cool
6 W_ _ 1613-19ad_. __-
_ -0.049 -n _ 1.42 - -259 - _-0 ---- -Q - --- -0 - - -0 - - --0 -- -._.0--
0 0
WWW Blk wall,stucco ext 0.201 n 5.83 4.06 0 0 0 0 0 0 0 0
10C-v 0.550 n 15.95 1620 0 0 0 0 0 0 0 0
2A-2ov 0.330 n 957 852 0 0 0 0 0 0 0 0
11 2A-2ov 0-330 n 957 852 0 0 0 0 0 0 0 0
W -_-- 166-19ad _ _ _ _.
_0 049 e- 1-42 259 _-- -0 -- 0 - 0 - - 0 .. - -0 - --0 - 0 - _0.
Vf/ Blk wall,stucco ext 0.201 a 5,83 4.06 150 117 684 476 0 0 0 0
2A-2ov 0.330 a 9.57 21.79 0 0 0 0 0 0 0 0
2A-2ov_-- _ 0.330 -.a 957 -__22.35_ _-_ 33-_ _--_- -2 _- ----313 --- --730 ---- --0
0.049 s _ 1.42. - ._ 259 ___--_- 0 _-- _0__. _ _ 0 .__0
Blk vall,stucco ext 0.201 s 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0.330 s 957 822 0 0 0 0 0 0 0 0
213-2fv 0230 s 9.57 11.58 0 0 0 0 0 0 0 0
2B-2fv 0230 s 9.57 9.72 0 0 0 0 0 0 0 0
11J0 0.600 s 17AO 1758 0 0 0 0 0 0 0
-__,_.- __.. _-___. __.__
W 16B 19ad _ 0,049 w-- -- 1.42 _ 259 _ _-_O _-- 0_____0 0 _ _0_ ..._ _0 _
tVt! Blk u�all,stucco e)d 0.201 w 5.83 4.06 0 0 0 0 0 0 - 0 0
-G ?A-2ov 0230 w 957 22.35 0 0 0 0 0 0 0 0
P ._ ..12C-Osnr _.. __. . _. _-0.091 _- . _ 2.64 131- - -,_14.0 -. _140 -_ _-,W9 _ - _1 - -.-60 ._- 60 158 _ ----__79
C ........ 16B-30ad_ -..__..9.032_._ ._ ..0.93. ._. -LB9 .. __..246 . 246 -228 416 _36 36 - 33 .
F._ _ 22A-Ipl -___ 0.989 _ 28.68 61.
0.00 _. .246 - - .29 --832 0-- 36 - - 6 - 172 0
6 c)AED excursion 81 -33
Envelope loss/gain 2426 1887 364 107
12 a) Infiltration 288 80 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Appliances/other 1200 600
Subtotal(lines6 to 13) 2714 3168 364 707
Less edemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2714 3168 364 707
15 Duct loads 17% 29% 471 919 17% 29% 63 205
Total room load 3185 4087 427 912
Air required(cfm) 129 185 17 41
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-FF wrightsoR- 2021-Sep-2813:43:07
Right-Sute@Uriversal202121.0.07RSU24004 Page
820DGFr ot2OB]k5Waterstoriel82ODGR_TrareA]Lfp Calc=MJB FrordDoorfaces:S
. ` DEL-AIR Duct System Summary Job: Lot 20 Block 5 Waterston...
"a'nNG°MR C0ND1i1°NMG Date:
Entire House By: Dcs
DEL AIR HTG,A/C& REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3653 Web:W W W.DELAIR.COM
Project • •
For: ADAMS HOMES
5377 San Benedetto Place,Fort Pierce,FL 34951
I
Heating Cooling
External static pressure 0.40 in H2O 0.40 in H2O
Pressure losses 0.06 in H2O 0.06 in H2O
Available static pressure 0.34 in H2O 0.34 in H2O
Supply/return available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O
Lowest friction rate 0.300 in/100ft 0.300 in/100ft
Actual airflow 1160 cfm 1160 cfm
Total effective length(TEL) 113 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Mat Ln(ft) Ln(ft) Trunk
BATH 2 h 832 34 23 0.394 4.0 Ox 0 VI Fx 16.3 70.0
BDRM 2 h 4740 193 129 0.366 8.0 Ox 0 MFx 22.9 70.0
BDRM 3 c 2108 76 95 0.433 6.0 Ox 0 MFx 8.6 70.0
DENBDRM4 h 4189 170 120 0.409 7.0 Ox0 VIFx 13.2 70.0
DINING/FOYER c 3698 142 167 0.444 7.0 Ox 0 VIFx 6.5 70.0
FAMILYRM c 3309 106 149 0.330 8.0 Ox 0 VIFx 17.9 85.0 sti
KrrCHEN/NOOK c 4087 129 185 0.323 8.0 Ox 0 VIFx 20.1 85.0 sti
LAUNDRY c 912 17 41 0.316 4.0 Ox 0 VIFx 22.7 85.0 sti
M.BATH h 1655 67 51 0.317 5.0 Ox 0 VI Fx 22.2 85.0 sti
M.W Ic c 102 2 5 .0.318 4.0 Ox 0 VI Fx 21.9 85.0 sti
MSTR BDRM h 5510 224 196 0.300 8.0 Ox 0 VI Fx 28.2 85.0 sti
SupplyTrunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk
sti PeakAVF 545 627 0.300 586 14.0 0 x 0 VinlFlx
wrightsofta 2021-Sep-2813:43,08
.w,�k•,�,F,rt�w. a� Right-SLiteDUriversal202l 2l.O.O7 RSU24004
Page 1
ACCK 820DGR\Lot2OBlk5Waterstonel82ODGR_TraneA mp Calc=MJ8 FrordDooriaces:S
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (Cfm) (Cfm) (ft). FR (fpm) (in) (in) Opening(in) Mat Trunk .
rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx
Wrightsoft' 2021-Sep-2813:43:08
•�-r,�.,�•w.q . Right-Sute®Uriversal2021 21.0.07 RSU24004
Page 2
820DGRLo2OBlk5Waterstoml82ODGR TrareAILW CaIc=MJ8 FroMDoorfaces:S
44 M p 9, 111
BEDROOM N2 LAR61
na mwc vxuu omaa vwnn®xro �^v
130
5" bath duct r'laxe a zxtz o � NE,
Kl
to roof cop B-i wn�
N
w/ standard 70 rna 19x2lwcd
cfm bath fan xns a o =— o0
16.16 rlo'gJl� z16 rag {y A Q O e1 � OJ�
8z41 w54 1 14 rog FAMIIY ROOM B. 5�� bath duct fl
e ,ram 4• r-e to roof cap v g�
�14.8 lwcd w/ standard 70
a CJ ! m
150
a.6 R=a ® cfm both fan n '�
tOx rog b � —1
10z6 lwmca lOz6 lw
90 6• � - 55
P 14• 5" OWNER
b�
C46e
r oc
Mns«
24x 8 A 9 B• u, Ell
DINING ROOM �n� �14.8 loved
-a mnp 7• 185 b 42X42 A/C SLAB N
g 12:s°i 4 ° $ BY BLDR MIN
2' FROM WALL LU H
N4faK Q
9• 12x12 1.9 f 0
7. ax tap
ao
12,2 ra g EQYE@ O 4•d r Q t
8 YE o 1
w/d,y yer vM box
BEDROOM Y4 .t r A
12.6 twcd g8tl tzNzopv� 2 CAR GARAGE
120 16b r oa.No w 1
O
v: LU I
k wa ar—eom Q Cn
LU
3.0 TON W/5KW 0240V 1PH O Q
S18z13 plen
plot I—by 0 O Q]
bldr AREA CALCULATIONS Q � N o 1+7 }
m uw u4 v. —
fn m
NOTE TO UNDERCUT
BELO PROVIDE UNRESTRICTED rorw uxzo p0 ,vo v. uJ •• � LZ
1 INCH UNDERCUT BELOW DOORS TO HABITABLE ROOMS c.xza; ]ue u.
Transfe!duets/grills shed In eompllon ce raves — Z ll.l
with ilarldo Residential Building Code-M1602A FLOOR PLAN cmtixm".A— "'y J Q I— CO ~ Q
balanced return W, J O 7 Q Lt:
EXCEPTIONS 1-3 d..r,r•-•�'-r T.aex veil ova 1uo v. CLl N Q 0
ALL ELEVATIONS
Rating
Must have a minimum clearance of 4 inches around the air handler per the State Energy code. All duct has an r=6 insulation value.