HomeMy WebLinkAboutRevisions OFFICE USE ONLY: -�
DATE FILED: PERMIT# �--10� 011 r1
REVISION FEE: RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION -
2300 VIRGINIA AVENUE RECEIVED
FORT PIERCE, FL 34982-5652
(772)462-1553 OCT 14 2021
APPLICATION FOR BUILDING PERMIT REVISIC&Lucie County, Permitting
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
DUE TO EQUIPMENT SHORTAGES,TRADE TO INSTALL TRANE AIR CONDITIONER ILO CARRIER
FILE COPY
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CRC1330146 ST. LUCIE CO CERT. #: 29179
BUSINESS NAME: ADAMS HOMES OF NORTHWEST FLORIDA, INC.
QUALIFIERS NAME: WILLIAM BRYAN ADAMS
ADDRESS: 3000 GULF BREEZE PARKWAY
CITY: GULF BREEZE STATE: FL ZIP; 32563
PHONE (DAYTIME): 772-905-8394 FAX: 772-905-8511
OWNER/BUILDER INFORMATION:
NAME: ADAMS HOMES OF NORTHWEST FLORIDA,INC.
ADDRESS:3000 GULF BREEZE PARKWAY
CITY: GULF BREEZE STATE: FL ZIP: 32563
PHONE(DAYTIME: 772-905-8394 FAX: 772-905-8511
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
SLCCC.• 9123109
Revised 06130117
FRECEIVE-i-I2ort
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDIN 6ftf-
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 26 Block 5 Waterstone 1512 AGL Builder Name: ADAMS HOMES
Street: 5356 Vespera Street Permit Office:
City,State,Zip: Fort Pierce,FL,34951
Owner: REVISI - ,� --16Gt
Design Location: FL,ST_LUCIE_CO_INTLFI rida limate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Type$1641.9 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1347.00 ft2
b.Frame-Wood,Adjacent R=13.0 294.94 ft2
3. Number of units,if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Types (1512.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1512.00 ft2
6. Conditioned floor area above grade(ft2) 1512 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
7. Windows(174.2 sqft.) Description Area 12.Ducts R ft2
a. U-Factor: Dbl,U=0.33 118.38 ft2 a.Sup:Attic, Ret:Main,AH:Main 6 302.4
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.33 35.00 ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21 a.Central Unit 28.6 SEER:16.00
c. U-Factor: Dbl,U=0.55 17.78 ft2 FILE COPY
SHGC: SHGC=0.70 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 3.801 ft. a.Electric Heat Pump 27.8 HSPF:9.00
Area Weighted Average SHGC: 0.275
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15.Hot water systems
SHGC(AVG): N/A a. Electric Cap:40 gallons
9. Floor Types (1512.0 sqft.) Insulation Area EF:0.940
a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features
b.N/A R= ft2 None
c. N/A R= ft2 16.Credits Pstat
Glass/Floor Area: 0.115 Total Proposed Modified Loads: 46.87 PASS
Total Baseline Loads: . 50.05
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in c pliance with the FI ida Energy specifications covered by this p
Code. calculation indicates compliance
..'
with the Florida Energy Code.
PREPARED BY: Before construction is completed r T
DATE: - - this building will be inspected for ,. -_ !
compliance with Section 553.908 �..
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florid Energy Code. OD.y
OWNER/4GEON' BUILDING OFFICIAL:
DATE: 4-DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 4
FORM�R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Lot 26 Block 5 Waterstone 15 Bedrooms: 3 Address Type: Lot Information
Building Type: User Conditioned Area: 1512 Lot# 26
Owner Name: Total Stories: 1 Block/Subdivision: Waterstone
#of Units: 1 Worst Case: No PlatBook:
Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5356 Vespera Street
Permit Office: Cross Ventilation: No County: St. Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce,
Family Type: Detached FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1512 13608
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1512 13608 Yes 4 3 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 158.9 ft 0 1512 ft2 ---- 0.47 0 0.53
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 1691 ft2 378 ft2 Medium N 0.85 N 0.85 No 0 26.57
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1512 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1512 ft2 0.11 Wood
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent F yOrnt T Wall TypeSpace Cavity Width Height Sheathing Framing' Solar gBelow
1 N Exterior Concrete Block-Int Insul Main 4.1 39 10 8 9 348.5 ft2 0 0 0.6 0
2 SW Exterior Concrete Block-Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0
3 W Exterior Concrete Block-Int Insul . Main 4.1 18 1 8 3 -149.2 ft2 0 0 0.6 0
4 NW Exterior Concrete Block-Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0
5 S Exterior Concrete Block-Int Insul Main 4.1 53 7 8 7 459.9 ft2 0 0 0.6 0
6 E Exterior Concrete Block-Int Insul Main 4.1 41 2 8 7 353.3 ft2 0 0 0.6 0
7 - Garage Frame-Wood Main 13 35 9. 8 3 294.9 ft2 0 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 W Insulated Main None .25 3 6 8 20 ft2
2 Wood• Main None .25 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
# Ornt _.ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 13 ft 0 in 1 ft 4 in- None None
2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 0 in .0 ft 10 in Drapes/blinds None
3 SW 2 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
4 W 3 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft2 7 ft 4 in 0 ft 9 in Drapes/blinds None
5 W 3 Vinyl Low-E Double Yes 0.33 0.21 N 15.0 ft2 Y ft 4 in - 1 ft 0 in Drapes/blinds None
6 NW 4 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None
7 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None
8 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None
9 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 30.6 ft2 8 ft 4 in. 0 ft 10 in Drapes/blinds None
10 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None
11 E 6 Vinyl Low-E Double. Yes 0.33 0.23 N -32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 390 ft2 390 ft2 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004 1587.6 87.1 163.52' .1324 7
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant,Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split Sing[ HSPF:9 27.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER: 16 28.6 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return--- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Coo[
1 Attic 6 302.4 ft Main 75.6 ftz Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr May ri Jun rl
Jul rj Aug
rl
Se Oct Nov Dec
Heatin H
Jan H
Feb HX
Mar APr May Jun Jul AuSep 1XI
Oct XNov X Dec
Ventin Jan Feb Mar [X]Apr [ May Jun Jul Aug Se Oct X Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index,the more efficient the home.
5356 Vespera Street , Fort Pierce, FL, 34951
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1347.00 ft2
b.Frame-Wood,Adjacent R=13.0 294.94 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area
a.Under Attic(Vented) R=30.0 1512.00 ft2
6. Conditioned floor area(ft2) 1512 b.N/A R= ft2
7. Windows** Description Area c. N/A R= ft2
a. U-Factor: Dbl,U=0.33 118.38 ft2 12.Ducts,location&insulation level R ft2
SHGC: SHGC=0.23 a.Sup:Attic, Ret:Main,AH:Main 6 302.4
b. U-Factor: Dbl,U=0.33 35.00 ft2
SHGC: SHGC=0.21 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.55 17.78 ft2 a.Central Unit 28.6 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: other(see details) 3.00 ft2 14.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Heat Pump 27.8 HSPF:9.00
Area Weighted Average Overhang Depth: 3.801 ft.
Area Weighted Average SHGC: 0.275
8. Skylights Description Area 15.Hot water systems
a. U-Factor(AVG): N/A ft2 a. Electric Cap:40 gallons
EF:0.94
SHGC(AVG): N/A b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft2 Credits(Performance method) Pstat
b.N/A R= ft2
c. N/A R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building ZgE ST
Construction through the above energy saving features which will be installed (or exceeded) o� ATFo
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,''���
based on installed Code compliant-features.
Builder Signature: Date:
Address of New Home: City/FL Zip: j;-
CoD WF
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1
R CEIVED
FORM R405-2020 OCT I '021
ST. Lucie County, Permitting
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance 1=Alternat de:. 10
P",� V;
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification(usually four pages/may be greater)
❑ Energy Performance Level(EPL) Display Card(one page)
❑ HVAC system sizing and selection based on ACCA Manual S orper exceptions provided in Section R403.7
❑ Mandatory Requirements(five pages)
FILE COPY
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.9 -one page)
❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4
allows dwelling units of R-2 OccuPancies and multiple attached
d single family dwellings to
comply with Section.C402.5
❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed
2020 Duct Leakage Test Report-Performance Method(usually one page)
9/28/2021 3:47:21 PM Energy0auge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 5356 Vespera Street Permit Number:
Fort Pierce,FL,34951
MANDATORY REQUIREMENTS -See individual code sections for full details.
V/ SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
❑ (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturers instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3. Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems, if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
❑ per square foot 1.5 L/s/m2 and swinging doors no more than 0.5 cfm per square foot 2.6 L/s/m2 when tested according to NFRC 400 or
P q ( ). 9 9 P q ( ). 9
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,
including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise
sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa)across the entire
system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where Qn=
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are
installed,they shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall
❑ be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
❑ R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps(Mandatory). Storage water heaters notequipped with inte integral heat traps and having vertical pipe risers shall have
P ( ry) 99 p 9 P P
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140OF(38°C to 600C).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of
combustion types of service water-heating systems to be turned off.
❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical
ventilation,the air handler shall be powered by an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment.
R403.7.1 Equipment-sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the
outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other
factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUIV
(CFM) (CFM/WATT) (CFM)
HRV or ERV Any 1.2 cfm/watt Any
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5
I_
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall-be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with'Sections
❑ C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,.
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C).
❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 5
R403.10.3 Covers. Outdoor heatedswimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
L1 the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation p p gy g, p pera ion season,is from site recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
R403.13 Dehumidifiers(Mandatory If installed,a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
❑ R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall,in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6..
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5
it c
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a
Project Name: Lot 26 Block 5 Waterstone 1512 AGL Builder Name: ADAMS HOMES
Street: 5356 Vespera Street Permit Office:
City,State,Zip: Fort Pierce,FL,34951 Permit Number: Y
Owner: Jurisdiction: 661000 Lu
Design Location: FL,ST_LUCIE_CO_INTL U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind puping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exteriorwalls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition,inspection of log walls shall be in accordance with the provisions of]CC-400.
9/28/2021 3:47 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation,7th,Edition
Jurisdiction: 661000 Permit#:
S
Job:Information
Builder: ADAMS HOMES Community: Lot: 26
Address: 5356 Vespera Street
City: Fort Pierce State: FL Zip: 34951
Alr Leakage:TeSt,ReSWfS Pass�ngresultsmustmeet either,th6Performance;Prescrptwe,;or ERlMethod
O PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage.rate of not,exceeding 7 air
changes peY'hour at a pressure of 0 2 inch w g;`(50 Pascals}m Climate Zones 1 and,2
Q PERFORMANCE or ERl METHOD The building or dwelling unit shall be tested and'verified,es having an air'leakage rate of not exceetlmgR
the selected ACH(50)`value,as shown on Form R40552020(P.erformance)or R406 2020(.ERI),section-labeletl4as;infiltration„sub section ACH50:
ACH(50)spectfled+on Form R405-2020=Energy Calc(Performance)`or R406-2620;(Emy 7.000
x 60 _ 13608 = Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
FIPASS Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation Q.Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control
measures.
3. Interior doors,if installed at the time of the test,shall be open.
4. Exterior.doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Tesfing-Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester:' Date of Test:
'Printed Name of Tester:
License/Certification#: Issuing Authority:
9/28/2021 3:47:50 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1
/� Manual S Compliance Report Job: Lot 26 Block 5Waterstone...
$ DEL-AIR Date:
xames•we eoN11M.O G Entire House By: FLETCH
DEL-AIR HEATING &AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:W W W.DEL-AIR.COM
Project • •
For: ADAMS HOMES
5356 Vespera Street,Fort Pierce,FL 34951
Cooling Equipment
Design Conditions
Outdoor design DB: 90.4OF Sensible gain: 22400 Btuh Entering coil DB: 76.8°F
Outdoor designWB: 77.4`F Latent gain: 3690 Btuh Entering coilWB: 63.4OF
Indoor design DB: 75.0 OF Total gain: 26090 Btuh
Indoor RH: 50% Estimated airflow: 953 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Trane Model: 4TWR603OH1+TEM6AOB3OH21++TDR
Actual airflow: 953 cfm
Sensible capacity: 23853 Btuh 106%of load
Latent capacity: 4153 Btuh 113%of I oad
Total capacity: 28007 Btuh 1071/.of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 41.0`F Heat loss: 24891 Btuh Entering coil DB: 69.2°F
Indoor design DB: 70.0.°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Trane Model: 4TWR603OH1+TEM6AOB3OH21++TDR
Actual airflow: 953 cfm
Output capacity: 24827 Btuh 100%of load Capacity balance: 37 OF
Supplemental heat required: 64 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 953 cfm
Output capacity: 5.9 kW 81%of load Temp.rise: 19 cF
Meets all requirements ofACCA Manual S.
Wrlghtsoft® 2021-Sep-2815.4528
ti, a�• •� ��M Right-Sute®Uriversal2021 21.0.07 RSU24004
Page 1
...512AGL\Lot26BIk5Waterstore1512AGL_TraneAlt.rLp CaIc=MJB Hoisefaces:NW
DEL-AIR Component Constructions Job:
: Lot 26 Block 5waterstone...
xEAru1G•AIR CORMONNG Entire House By: FLETCH
DEL-AIR HEATING &AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DEL-AIR.COM
Project • •
For: ADAMS HOMES
5356 Vespera Street,Fort Pierce,FL 34951
Design Conditions
Location: Indoor: Heating Cooling
St Lude Cc Intl,FL,US Indoor temperature(OF) 70 75
Elevation: 26 ft Design TD(OF) 29 15
Latitude: 28°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr4b) 2.4 56.9
Dry bulb(OF) 41 90 Infiltration:
Daily range(OF) - 15 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ftz Btuhtftz*F ftz'FBtuh BtuWft' Btuh Btuh/ft� Bluh
Walls
Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board int fnsh n 323 0.261 4.1 5.83 1884 4.06 1313
e 267 0.201 4.1 5.83 1555 4.06 1083
s 434 0.201 4.1 5.83 ,2529 4.06 1762
sw 8 0.201 4.1 5.83 46 4.06 32
W 112 0.201 4.1 5.83 650 4.06 453
nw 8 0.201 4.1 5.83 46 4.06 32
all 1151 0.201 4.1 5.83 6711 4.06 4675
Partitions
12C-Osw:Fan wall,1/2"gyp.bd ext,r-13 cav ins,1/2"gypsum board int 278 0.091 13.0 2.64 734 1.31 364
fnsh,2"x4"wood frm,16"o.c.stud
Windows
10C-v:2 glazing,clr low-e outr,air gas,vnl frm mat,dr ,innr,1/4"gap,1/8" n 18 0.550 0 16.0 285 16.2 289
thk;NFRC rated(SHGC=0.70);13 ft overhang(6.7 ft window ht,1.3 ft
sep.);6.67 It head ht
2A-2ov:2 glazing,clr outr,air gas,vnl fnn mat,clr low-e innr,1/4"gap,1/8" n 7 0.330 0 9.57 66 8.52 58
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.3 ft overhang
(3.17 It window ht,0.83 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8" a 30 0.330 0 9.57 287 8.52 256
thk;NFRC rated(SHGC=0.23);50%drapes,medium;8.33 ft overhang(5
ft window ht,0.83 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" a 23 0.330 0 9.57 222 22.5 522
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.3 ft overhang
(5.25 ft window ht,0.83 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" a 33 0.330 0 9.57 313 22.5 736
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.3 ft overhang
(5.3 ft window ht,0.83 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" s 10 0.330 0 9.57 93 8.52 83
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.3 ft overhang
(3.17 ft window ht,1 ft sep.);6.67 It head ht
W trightsaft- 2021-Sep-28 15:4528
•wu.,•re.w,,.µ,m-,vmwro Rigid-Slite@Uriversal202l2l.D.O7RSU24004 Pagel
ACCK 512AGL\Lot26Blk5Waterstore1512AGL TraneAlt.rLp Calc=MJB Hotsefaces:NW
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" s 16 0.330 0 9.57 156 8.52 139
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.3 ft overhang
(5.3 ft window ht,1 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8'` sw 10 0.330 0 9.57 96 15.0 150
thk;NFRC rated(SHGC=0.21);50%drapes,medium;1.3 ft overhang(5 w 15 0.330 0 9.57 144 21.4 321
ft window ht,1 ft sep.);6.67 ft head ht nw 10 0.330 0. 9.57 96 16.6 166
all 35 0.330 0 9.57 335 18.2 637
2B-2fv:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap;1/8" w 3 0.330 0 9.57 29 9.72 29
thk;NFRC rated(SHGC=0.31);50%drapes,medium;7.33 ft overhang(1
ft window ht,0.75 ft sep.);6.67 ft head ht
Doors
11 JO:Door,mtl fbrgl type w 20 0.600 6.3 17.4 350 17.6 353
11 DO:Door,wd sc type n 18 0.390 0 11.3 202 11.4 204
Ceilings
1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 1580 0.032 30.0 0.93 1467 1.69 2670
gypsum board int fnsh
Floors
22A-tpl:Bg floor,light dry soil,on grade depth 192 0.989 0 28.7 5519 0 0
" wrightsc f - 2021-Sep-2815:4528
.�..•s•. ,.•w�_ Rigft-SUte®Uriversal 2021 21.0.07 RSU24004 Page 2
512AGL1Lot26Blk5Walerstore1512AGL_TrarL-Alt.np Calc=MJ8 Hoisefaces:NW
: DEL-AIR Project Summary Job: Lot 26 Block 5Waterstone...
K=NG•we.coxnmOM11 Entire House By- FLETCH
DEL-AIR HEATING &AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL32771 Pfore:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Project • •
For: ADAMS HOMES
5356 Vespera Street,Fort Pierce,FL 34951
Notes: RVSD 8-17-15 JA
L.S. 1-14-21 VWK
Design Information
Weather: St Lucie Co Intl,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 41 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 29 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 57 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 19507 Btuh Structure 16303 Btuh
Ducts 5384 Btuh Ducts 6097 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 24891 Btuh Use manufacturer's data y
Rate/swin multiplier 1.00
Infiltration Equipment sensible load 22400 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2548 Btuh
Ducts 1142 Btuh
Central vent(.0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 151g 151g Equipment latent load 3690 Btuh
Volume(ft3) 13571 13571
Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 26090 Btuh
Equiv.AVF(cfm) 86 45 Req.total capacity at 0.75 SHR 2.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade TRANE Trade TRANE
Model 4TWR603OH1 Cond 4TWR603OH1
AHRI ref 7562380 Coil TEM6AOB3OH21++TDR
AHRI ref 7562380
Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER
Heating Input Sensible cooling 21450 Btuh
Heating output 27800 Btuh @ 47OF Latent cooling 7150 Btuh
Temperature rise 27 OF Total cooling 28600 Btuh
Actual airflow 953 cfm Actual airflow 953 cfm
Airflowfactor 0.038 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0.40 in H2O Static pressure 0.40 in H2O
Space thermostat Load sensible heat ratio 0.86
Capacity balance point=37 OF
Backup:
Input=6 kW, Output=20230 Btuh,100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft` 2021-Sep-2815:4528
CK °w-+� w^• Right-SdteOUriversal 2021 21.0.07 RSU24004 Page 1
512AGL1Lot26Blk5Waterstore1512AGL_TraneAlt.rrp Calc=W8 Horsefaces:NW
DEL-AIR Right-JO Worksheet Job: Lot26 Block Waterstone 15...
•amcotmmormtc Entirle House Date:
By: FLETCH
DEL-AIR HEATING &AIR CONDITIONING
531 CODISCOWAY,,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
1 Room name Entire House WIC
2 Exposed wall 192.4 It 8.0 ft
3 Room height 9.0 It 8.3 ft heal/cool
4 Room dimensions 1.0 x 41.8 It
5 Room area 1516.0 ft' 41 B ft2
Ty Construction U-value Or HTM Area (ftz) Load Area (ft) Load
number (Btuh/ft-9 (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
J_HeatCool Gross N/PrS Heat Cool Gross N/P/S Heat Cool
6Blkwall,stu000eM" 0.201 n 4.06 � 323 1884 1313 0V�l10C v 0550 n - 1620 18 0 285 289 0 0 0 0
330 n 8S2 7 0 - 66 58 0 0 0 0
VVV[ Blk vall,stucco ext 0201 e 4.06 353 1 2A-2ov 0230 a 852 30 30 287 256 0 0 0 0
2A-2ov 0230 a 9.57 2251 23 1 222 522 0 0 0 0
2A 2ov 0.330 e_ 9.57, 2252 33 2 313 _736, 0 ___ _0 0 0
- Blkvell stumoexe _ 0201 s 583 406 460 434 2529 1762 d.__ 0 _ . _0 ,
2A 2ov 0.330 s 957 8.52 10 10 93 83 0 0 0 0
9.5T___8.52 .1-6.�___6 156_ --- 139__. _._0_ __ 0__x_ _0
y/ Blk veil,stu000 ext 0.201 sw 5.83 4.06 18 8 46 32 0 0 0 0
_..v—_<G_2A_2ov 0230._sw 9.57 14.96 10 -? 96_--- _150._ 0_._.. .-----___ Q _._.Q
Blk well sluom ext 0 201 w 5,83 4 05_ 150 112 650 453 3 3 17 12
2A 2ov 0.330 w 957 21.41 15 0 144 321 0 0 0 0
213 2N 0.330 w 957 9 72- 3 3 .29 29 0 0 0 0
,,0.600__w_ .. _17A0: :.._1758 _LL.,_ .20 _ __ .20 e.,_. „..350_ _..353 _.____ 0 .__,.m_...0' ..__.._w0 __0,
Blk v"I,stucco eM 0.201 nw 5.83 4.06 18 8 46 32 0 0 0 0
t—G 2A 2ov 0.330 nw 9,57 16.61 10 0 0 0 0
- 96 166 0
O'.091- � 264,-._ 131 29,_6 278 734 364 : 64 64 169 84
_090_n_ 1131 ____.18_ :_202 - 204
C w 1613-30ad 0.032 093 1.69 1580 1580 1467 2670 43 43 40 73
__. _,
F_w .._ AEI_ _192 :::5519 __ _0 ... ..___42
71
6 c)AED excursion 0 -6
Envelope loss/gain 16768 11017 455 162
12 a) Infiltration 2739 766 6 2
b) Room ventilation 0 0 0 0
13 Internal gains: Occupantspo 230 4 920 0 0
Appliances/other 3600 0
Subtotal(lines6 to 13) 19507 16303 461 164
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 19507 16303 461 164
15 Duct loads 128%1 379/6 5384 6097 289/6 37% 127 61
Total room load 24891 22400 588 225
Air required(cdm) 953 953 231 10
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-Fla- wrightsoft^ 2021-Sep-2815:4528
Right-Sute@Uriversal 2021 21.0.07 RSU24004 Page 1
512AGL\Lot26Blk5Waterstone1512AGL TraneAlt.rLp Calc=MJ8 Hoisefaces:NW
DEL-AIR Right-JO Worksheet Job: Lot 26 Block 5 Waterston 15...
HEMG-AM NOW= Entire House Date:
DEL-AIR HEATING&AIR CONDITIONING By: FLETCH
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
1 Room name NBATH WC
2 Exposed wall 17.5 It 4.0 ft
3 Room height 8.7 ft heat/cool 9.0 It heat/mol
4 Room dimensions 1.0 x 136.0 ft 1.0 x 20.3 It
5 Room area 136.0 ft2 20.3 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ftz`F) (BtuhRt2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 yJ Blkvsll,stu000e)d.- 0201 _.n_ _. 5.83
1 OC-v 0550 n 1625 1620 0 0 0 0 0 0 0 0
2A2ov 0.330 n 957 852 7 0 ____,.__66___ -_ .58...,_____._0 0 0 0
Blk%dI,stuooD&d__ __,--0201 e- _ . 5.83 - 4A6 0 0 0 0 6 ._6_. _---- � 0
11 2A-2ov 0.330 a 957 852 0 0 0 0 0 0 0 0
2A-2ov 0.330 a 957 2251 0 0 0 0 0 0 0 0
_ 2A2ov ___ __ _ _,._0,330 _e_ 957 _2252 _ __......_0___ ___ 0 �__r__0.--_-- - __,_..... 0---_-- ..0 _-- _ 0 ._0
Blk v all,sit co M 0201 s 5,83 - 4.06 0 0 0 0 0 0 0 0
2A 2ov 0.330 s 957 852 0 0 0 0 0 0 0 0
____0330__s_ 957_--__852 _ _ 0.___ __Q ____...___0 _--___0-_._._ __ 0 _ ___0 __._.___ _0. _. _.._. 0
V+1 Blk well,stuoca ext 0.201 sw 5.83 4.66 6 0 0 0 0 0 0 0
_._- ..-2A 2oy._. _.._ -__._._9,330 sw_ 957 _._.14.96 ._ 0 W..0____._ __0 _.__0 _..
Blk wall,stu000 ext 0:201 w 5.83 4.06 6 6 32 22 0. __..___-b-.__---_0 _ _._.._0
2A 2ov 0.330 w 957 21.41 0 0 0 0 0 0 0 0
26-21v - 0.330 w 9.57 9.72 0 0 0 0 0 0 0 0
,_0.600 _.w_ __17.40. ._.._17.58 . .._...._0 ._. __.._._0__ _...._-0,_ _.0 _„;._..._. 0 _ . _____0 ....__..___0 __.,;._ .,.0
Blk wall,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
t-G 2A-2ov ry 0.330 nw„ 9.57 16.61_ 0 0 0 0 0 0 0 0
R 12C-Osw. 0.091 2.64 , 131 44 44 116 58 0 ._ 0- O _0
L-D 11D0___ _ ._.0.390_-n- .-11.31. ... 11.43 0 ___ _
0 ___..___0 0 ._.._.__ 0 _ __.0._,
C 16B-30ad 0.032 0.93 1.69 147 147 136 248 22 22 21 38
1p _0989 _. _-2EIBR _.;0.00 _. 136 0.2 _0 __.20 .........__4_._ jig 0
6 c)AED excursion -28 _7
Envelope loss/gain 1372 721 322 161
12 a) Infiltration 207 58 65 18
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Applianoes/other 0 0
Subtotal(lines6 to 13) 1578 778 387 180
Less extemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1578 778 387 180
15 1 Duct loads 28% 37%1 436 291 28% 37% 107 67
Total room load T-F2014 1069 494 247
Air required(cfm) 77 45 19 10
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed.
-f�F wrigf�tsoft-
Righ[-Suite®Uriversal 2021 21.0.07 RSU24004 2021-Sep-2815:age 2
9
'�� ...512AGL\Lot2681k5Waterstone1512AGL_TraneAlt.np CaIc=MJB Hoisefaces:NW Page
i DEL-AIR Right-JO Worksheet Job: Lot26 Block 5 Waterstone 15...
' -MCOIM"UMG Entire House Date:
By. FLETCH
DEL-AIR HEATING&AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DEL-AIR.COM
1 Room name MBR LAU
2 Exposed wall 355 ft 6.0 ft
3 Room height 8.6 It heat/cool 8.0 ft heat/cool
4 Room dimensions 135 x 16.5 It 1.0 x 56.0 ft
5 Room area 222.8 ft2 56.0 ft2
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/tz-`l (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat C001 Gross N/PiS Heat Cool Gross N/PiS Heat Cool
6 VIl- f3 mall,stucco eM - _ -0.201 n 5 83 4.06- - 132 132 - --769 - 536 - 0 -0 __-0 ----0
10C-v 0550 n 1525 1620 0 0 0 0 0 0 0 0
2A-2ov 0.330 n 957 852 _ 0 0 0 0 0 0 0 0
Blk vdi,stucco e� T 0.201 --e - 5,83 _ 4.06 - 116 -- 84 _-_488 340_ _ ____-_ _ 0 -- ._--_ 0.__-.-_ 0 -- ..._-_0
11 2A-2ov 0.330 a 957 852 0 0 0 0 0 0 0 0
2A-2ov 0230 a 957 2251 0 0 0 0 0 0 0 0
_.._._ 2A-2ov __,-_ ___-0,330 _ e_-__-,-957___ 2252 _ .---_33 _2_._ 313 _
a __ 736 _.. _ 0 _ _0_. ..-_0 - _- Q
VL Blk vall,stuco0'ext 0.201 s 5.83 4.06 44' 44 256 179 0 0 0 -0
2A-2ov 0.330 s 957 852 0 0 0 0 0 0 0 0
0,330 s_ _ 957_..J__85.2_..._._._.O --- -0----,-,-Q _ 9 ..__ _._. 0__ .._ 0. - 0 0.
Blk well,stucco e)d 0.201 sw 5.83 4.06 0 0 0 0 0 0 0 0
I-G 2A_2ov _ _.____.__0230 _sw _..-_ 957 -_w14.96 0 _ .0-_..__._9._ ..---...0 ..._.._.- __ 0
y Blk uvall,stucco e# 0201 w 5.83 ' 4.06 0 0 0 0 0 0 0 0
2A-2ov 0230 w 957 21.41 0 0 0 0 0 0 0 0
2B-21v 0230 w 9.57 9.72 0 0 0 0 0 0 0 0
---.--- 11J0--------__---- -_-- .0.600_.w. _-1.7.40....-_-]758 ---_-----A'----- --0 _._-_-_ 0____-_ -0 _ ._ - - 0 ______.-0_ -- ---0 .-. ___ 0
Vf/ Blk wall,stucco eM 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
-G 2A-2ov 0.330 nw 9.57 16.61 0 0 0 0 0 0 0 0
fj 12C-0sw 0.091 2.64 121 -0 - 0 0 0 48 -- 48 - 127 ___.-63
L_-_-p--11D0 _- ---0390 n- 11,31 _ _11:43 _. _- --� ---0 _-__-0 __0_'_____0- ----0---
C 16B-30ad 0.032 0.93 1.69 238 221 402 56 56 _____.5 95
F - 22A'pl_ - ---- - 0.989 = _28:68 - 0-00 - - _ 36 1018 -- - 0 -- -56 - S --- 172 0
6 c)AED excursion 114 -27
Envelope los§gain 3065 2306 351 131
12 a) Infiltration 595 166 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Oocupants@ 230 1 230 0 0
Applianoes/other 600 600
Subtotal(lines 6 to 13) 3660 3303 351 731
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3660 3303 351 731
15 Dud loads 128% 379/6 1010 1235 28% 37%1 97 273
Total room load 4670 4538 448 1004
Air required(dm) 179 193 17 43
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
�� wrigtitsoft- Rigid-Su 2021-Sep-2815.4528te®Uriversa1202121.0.07RSU24004 Page
512AGL1Lot26Blk5Waterstore1512AGL_TraneAlt.np Calc=W8 Hosefaces:NW
rMEL--AIR Right-JO Worksheet Job: Lot26 Block 5 Waterstone 15...
x 0-amcormmutans Entire House Date:
By: FLETCH
DEL-AIR HEATING &AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:W W W.DEL-AIR.COM
1 Room name BR3 BATH2
2 Exposed wall 31.9 ft 6.0 ft
3 Room height 8.0 ft heat/cool 8.9 it heat/cool
4 Room dimensions 1.0 x 162.0 ft 95 x 6.0 ft
5 Room area 162.0 ft2 57.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ftz-cg (Btuhflt2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/PrS Heat Cool Gross N/P/S Heat Cool
6 V)l Blkasll,stucaoext__ _.b.201 n 583 -4.06 -.._44 44 - - __-25B 179 _..___.0 - _.0 ._,---- ..10 ._.._._O
ll—_GG 10C-v 0550 n 1 E95 1620 0 0 0 0 0 0 0 0
2A-2ov 0.330 n 957 852 0 0 0 0 0 0 0 0
Blk v�dl,stucco ex[ 0.201 a 5b3 4.06 0 0 0 0 0 0 0 - 0
11 2A-2ov 0.330 a 957 852 0 0 0 0 0 0 0 0
2A-2ov 0230 a 957 2251 0 0 0 0 0 0 0 0
2A-2ov 0230 a 957_ 2252 0 0 0 0 0 0 0 0
Blk Hell,stucco e)d - 0.201 ^s 5,83 4.06 108 108 630 439 48 - 48 - 280 195
2A-2ov 0.330 s 957 852 0 0 0 0 0 0 0 0
»0330 s- -_957,. -852 - -._.:0,- - - 0 - 0 10.___- ___0 -- - 0 -0
Blk wall,stucoo eM 0.201 sw 5.83 4.06 18 8 46 32 0 0 6 0
t—C 2A-2ov 0.330 _sw 957 14.96 10 2 96 150 0 0 0 0
---- - -
Blk%all,stucco ext 0201 w 5.83 4.06 68 53 309 215 8 8. 49 _ _._
V�--G 2A 2ov 0.330 w 957 21 Al 15 0 144 321 0 0 0 0
--C 2B-2fv 0.330 w 957 9.72 0 0 0 0 0 0 0 0
11J0 _._....__.__ _.0.600__w 17AO..__ 1758 0__. __ 0 _____0 _ 0 _ _ ____0 _ __0 _ __ _0 0
Blk mall,stucco eM 0.201 nw 5,83 4.06 18 8 46 32 0 0 0 0
t—G 2A-2ov 0.330 nw 957 16.61 10 0 96 166 0 0 0 0
R 12COsw 0.091 2.64 1J1 6 0 0 b_._ _. 0. _- _0 _. __. 0 _ _..6
__� 11D0______. -0.390 _-n 11.31 11.43_ 0 --- _ __0 -____0 0 _.._._ 0 __0 ___ _ 0 . _. 0
C 16B 30ad 0.032 am 1.69 162 162 150 274 62 62 58 105
F _ ... 22A-$ol-- _ -
0_989._-_ _28,68 _--.. 0.00 _ _162--- - _32 915-- -�. _ 57 _-_6 172 0
6 c)AED excursion 254 -13
Envelope losstgain 2688 2061 558 321
12 a) Infiltration 520 145 115 32
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Applianoestother 300 0
Subtotal(lines6 to 13) 3208 2507 673 353
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3208 2507 673 353
15 Duct loads 28% 37%1 885 937 28%1 37%1 1861132
Total room load 4094 3444 859 485
Air required(dm) 157 147 33 21
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-P�F wrGgtstsoTt^ 2021-Sep-2815:4528
Rigid-Suite®Uriversal 2021 21.0.07 RSU24004 Page 4
512AGL1Lot26Blk5Waterstcre1512AGL-TraneAlt.np Calc=MJ8 Hoisefaces:NW
sDEL--AIR Right-J®Worksheet Job: Lot 26 Block 5 Waterstone 15...
,
Entire House Date:
DEL-AIR HEATING &AIR CONDITIONING By: FLETCH
531 CODISCO WAY SANFORD,FIL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DEL-AIR.COM
1 Room name BR2 Krr
2 Exposed wall 11.0 ft 10.0 ft
3 Room height 8.6 ft heat/cool 8.7 ft heaUcool
4 Room dimensions 14.0 x 11.0 ft 1.0 x 120.8 ft
5 Room area 154.0 ftz 120.8 ftz
Ty Construction U-value Or HTM Area (ft2) Load Area (ftz) Load
number (Btuh/ft-'n (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/PIS Heat Cool Gross N/PJS Heat Cool
6 Blkk vall,stucoo eM -_ -0.201-n 5.83 _..'4.06 _..,.0 0 - - 0
10C-v 0550 n 15D5 1620 0 0 0 0 0 0 0 0
2A-2ov_.__-,_-_. - _____0.330 n__-- 957 _852. _ 0,----- 0 -._ 0 - 0 0- - - --_0
Blk well,stucco ext 0.201 a 5,83 4.06 0 0 0 0 0 0 0 0
11 2A-2ov 0.330 a 957 852 0 0 0 0 0 0 0 0
2A-2ov 0.330 a 957 2251 0 0 0 0 0 0 0 0
2A-2ov _ 0.330 e_ 9.57 _22.52 0 _ 0 0 _ _ 0 0 0 0 0
- Blk Hell,stucco ext- + -0201 s 5B3 4.06 88 72 -- 418 - 291 -- 80- 70 -- 409 285
2A 2ov .0.330 s 957 852 6 0 0 0 10 10 93 83
_. 2A2ov__ _ ___ _____0.330 s- _ 957.. 852--'_._.._16 ___ ---�6 -
Vd Blk Hell,stucco ext 0.201 sw 5.83 4.06 0 0 0 0 0 0 0 0
-G 2A-2ov 0 330 sw 957 14.96 0 0 0 0 0 0 0 0
Blkvall,stuccoe)d 0201 w __0 ...... 0_-_ 0 _ _ _ 0 0 -- 0 0
-G 2A-2ov 0.330 w 957 21.41 0 0 0 0 0 0 0 0
I--G 213-2fv 0.330 w 957 9.72 0 0 0 0 0 0 0 0
11J0_ - ,_____ _ __0.600_ w_ __ 17.40. _1758__ __0__ ___ 0 _._ -__0 _ __ _ 0 __ 0__. _D___. __ 0 .___.___0
vf/ Blk Hall,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
�--G 2A-2ov 0.330 nw 9.57 16.61 0 0 0 0 0 0 0 0
12C-Osw 0.091 2.64 121 .0 0 0 0. _.- .,_0-_.__._.:0._ _._0 _.._..0
11 Do____._. ___._ __0390-n- _11.31 _- 11.43 _0_-. - -_._0 __- 0 __0 - 0 _0
C 16B-30ad 0.032 0.93 1.69 164 164 152 277 130 130 121 219
F- 22A tpl,----- -- - __0.989____ _ 28.68 . 0.00 -154. __.11 _-_315 _._ 0 - - 121 -- -10_ _ 287 �.
6 c)AED excursion -37 -64
Envelope loss/gain 1042 670 910 524
12 a) Infiltration 179 50 163 46
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@a 230 0 0 0 0
Appliances/other 300 1200
Subtotal(lines 6to 13) 1221 1020 1073 1769
Lessextemal load 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1221 1020 1073 1769
15 Duct loads 28% 37°/ 337 382 28% 37% 296 662
Total room load 1558 1402 1369 2431
Air required(cfm) 60 60 52 103
Calculations approved bVACCA to meet all requirements of Manual J 0 Ed.
-f�.1- wrigF�tsoft^ f�gf 2021-Sep-2815.4528d-Sute®Uriversal202121.0.07RSU24004 Page
512AGL\Lct26Blk5Waterstore1512AGL-TrareAlt.rrp Calc=MJ8 HOrsefaces:NW
` DEL-AIR Right-M Worksheet Job: Lot 26 Block 5 Waterstone 15...
Entire House Date.
DEL-AIR HEATING &AIR CONDITIONING By: FLETCH
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DEL-AIR.COM
1 Room name DIN GRT/FOY/HALLS
2 Exposed wall 28.0 ft 34.5 ft
3 Room height 86 ft heat/cool 10.0 ft heaUcool
4 Room dimensions 1.0 x 119.0 ft 1.0 ,x 426.5 ft
5 Room area 119.0 ftz 426.5 ftz
Ty Construction U-value Or HTM Area (ftz) Load
(ftz) Load Area
number (Btuh/ftz-`F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross NIPS Heat Cool
6 . Blk Nsll,stucco ext V0201 "-h - � 5.83 4.06 44 26 152 106 0 0 0 0
10C-v 0550 n 15.95 1620 18, 0 285 289 0 0 0 0
2A-2ov__ ------- -----0.330_n_ ___957 --- 852 _0._ _4 _______0. . ---_---.0_- __0 _ ___._0-_--.-
�/ Blk vdl,stucco ext 0201 a 5.83 4A6 96 73 426 297 140 110 641 447
11 I({-G�,G 2A-2ov 0.330 a 957 852 0 0 0 0 30 ' 30 287 256
2A-2ov 0.330 a 957 2251 23 1 222 522 0 0 0 0
-_� _2A_2ov-- __ 0.330--e- _957-.._2252 -- -0 - - _ -T -
0 5- -0-- ---0 - -_0 ----_0 - --0
Blk well,stucco ext 0201 s 563 4.06 k2 M 536- 374 0 0 0 0
2A-2ov 0.330 s 957 852 .0 0 0 0 0 0 0 0
----0330_-5------ 957_ ___852 _0 -----.-__..._._0 ----_-A . 0____..___.-0_.__---._ 0
Vt/ Blk vsll,stucco ext 0.201 sw 5.83 4.06 0 0 0 0 0 0 0 0
__.. 2A_2oy- -- -- -- -0330 s'w -- _957 -_14.96-- - 0.. -0 - 0 -____0 -.0 _..-0
Blk wall,stucco e)d 0201 w 5,83 4.06 0 0 0 0 65 42 244 170
2A-2ov 0.330 w 957 21.41 0- 0 0 0 0 0 0 0
213-21v 0.330 w 957 9.72 0 0 0 0 3 3 29 29
_11J0____ ______ __ _0.600_w_ 17.40. 1758____.... _0 w__ - 0_ _ __._0 _ ._ ._ _0 __.____20 _...__._..20_.__.__350 _ 353
Vp/ Blk mall,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
-G 2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
12C Osvv__- --._ 0.091 2.64 131 _ _0 0 ___ 0_ _.0 .._140 122-.__- 322 -160
_.___.0390-n __11.31,__11.43 _ _ _T 0_.......0 __0._.- _ 0.-. _18_ -- _18 202
C _ 1613-30ad - 0.032 0.93 1 69 129 129 120 219 427 427 396 721
F-- tpI - - - -.-_0.989 = 28.68-___.000 _..^.__119 ---- 28 ---8M - 0 -_----427 - 35 - - 989 - -- _.0
6 c)AED excursion -76 -111
Envelope loss/gain 2545 1731 3461 2229
12 a) Infiltration 473 132 417 117
b) Room ventilation 0 0 0 0
13 Internal gains Occupants@ 230 1 230 2 460
Applianoes/other 0 600
Subtotal(lines 6 to 13) 3018 2093 3878 3405
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3018 2093 3878 3405
15 Duct loads 28% 37% 833 783 28% 37% 1070 1274
Total room load 3851 2876 4948 4679
Air required(cfm) 147 122 189 199
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-P�.F wrightsoft- Right-Su 2021-Sep-2815.45�8le®Uriversal 2021 21.0.07 RSU24004 Page 6
512AGULot26Blk5Waterstorel512AGL_TraneAlt.rLp Calc=MJ8 Hoisefaces:NW
DEL-AIR Duct System Summary Job: Lot 26 Block 5Waterstone1R ...
Date:
HEATING•Mil CGNGmGNN+G Entire House By FLETCH
DEL-AIR HEATING &AIR CONDITIONING
531CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Project • •
For: ADAMS HOMES
5356 Vespera Street,Fort Pierce,FL 34951
Heating Cooling
External static pressure 0.40 in H2O 0.40 In H2O
Pressure losses 0.06 in H2O 0.06 in H2O
Available static pressure 0.34 in H2O 0.34 in H2O
Supply/return available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O
Lowest friction rate 0.359 in/100ft 0.359 in/100ft
Actual airflow 953 cfm 953 cfm
Total effective length(TEL) 95 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk
BATH2 h 859 33 21 0.379 4.0 Ox 0 MFx 19.7 70.0
BR2 c 1402 60 60 0.408 6.0 Ox 0 VIFx 13.3 70.0
BR3 h 4094 157 147 0.359 7.0 Ox 0 MR 24.7 70.0
DIN h 3851 147 122 0.370 7.0 Ox 0 M Fx 22.0 70.0
GRT/FOY/HALLS c 4679 189 199 0.458 8.0 Ox0 MFx 4.3 70.0
KIT c 2431 52 103 0.406 6.0 Ox 0 VIFx 13.7 70.0
LAU c 1004 17 43 0.456 4.0 Ox 0 VIFx 4.6 70.0
MBATH h 2014 77 45 0.430 6.0 Ox 0 VIFx 9.0 70.0
MBR c 4538 179 193 0.411 8.0 Ox 0 VIFx 12.8 70.0
we h 494 19 10 0.417 4.0 Ox 0 VIFx 11.5 70.0
W Ic h 588 23 10 0.453 4.0 Ox 0 VI Fx 5.0 70.0
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk
rb2 Ox 0 953 953 0 0 0 0 Ox 0 VI Fx
C � Wrigf7tsoft- 2021-Sep-2815:4528
•�•t•�•�•~mw-���� Right-Sute®Uriversal2021 21.0.07 RSU24004 Page 1
ACCK 512AGL1Lo26BIk5Waterstore1512AGL_TraneAlt.np Calc=MJ8 Horsetaces:NW
V
42X42 A/C SLAB
BY BLDR MIN
2' FROM WALL O
xucTPB rsrlwvwr lbGNG a u 0 N 6 K
14XB 1I—d - 135 - N
12x6 lwcd U
5" bath duct p
to roof cap
w/ standard 70 1ex16 rvq Ibxe lwcd 7
cfm bath fan—light
6
5" bath duct 4lid d �
180 grva. 10x6110wcd
to roof cap IBxI KIWI
w/ standard 70 6-
cfm bath fan .13 }
yq CO
I0x6 lwcd 4 250 4.
8x4 t c 8.4 we 1 40 10x6 lwcd W W w :—; 70
.................: is�Jii�_a 10x ry QQ
4'd,yer d-t 5" bath duct i
to "Pt b,x to roof cap
w/ standard 70
4• cfm bath fan
R 1 4 1—d
2c 9G,,RuE -
'= G a ...................
12x12
7• LLI
Z
I zxlz rag NLU O
BEJiL2.5 TON W/SKW B240V iPH (n
115Q10 Plen
le:l/R'-"0' O r 12,6 lwcd = Y LLI
bar by 130 (n U F- Y
Q
0 m cV
I
NOTE TO BUILDER:MUST PROVIDE UNRESTRICTED / Q N Z
1 INCH UNDERCUT BELOW DOORS TO HABITABLE RC DmS cj O
N }
Transfer ducts/grills shed di complionc,e-MI N — m
b Ivncledidvturtsid'f tial Building Coda-M1602{ W •• 7 Z
EXCEPTIONS 1-3v p
Q F m t— Q
J O =) Q Ct
m t1 J 0 0 0
Rating
Must have a minimum clearance of 4 inches around the air handler per the State Energy code. All duct has an r=6 insulation value.