HomeMy WebLinkAboutRevisions OFFICfE USE ONLY:
DATE FILED: � � ' �\ PERMIT# aTa- CLASS
REVISION FEE: 'Q �� �� RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE _
FORT PIERCE, FL 34982-5652 RECEIVED
(772)462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS OCT 14 2021
PROJECT INFORMATION ST. Lucie County, Permitting
LOCATION/SITE
ADDRESS:
kba - C>q 3s
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION: FILE COPY
STATE of FL REG./CERT. #: CRC1330146 ST. LUCIE CO CERT. #: 29179
BUSINESS NAME: ADAMS HOMES OF NORTHWEST FLORIDA, INC.
QUALIFIERS NAME: WILLIAM BRYAN ADAMS
ADDRESS: 3000 GULF BREEZE PARKWAY
CITY: GULF BREEZE STATE: FL ZIP: 32563
PHONE (DAYTIME): 772-905-8394 FAX: 772-905-8511
OWNER/BUILDER INFORMATION:
NAME: ADAMS HOMES OF NORTHWEST FLORIDA,INC.
ADDRESS:3000 GULF BREEZE PARKWAY
CITY: GULF BREEZE STATE: FL ZIP: 32563
PHONE (DAYTIME: 772-905-8394 FAX: 772-905-8511
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC: 9123109
Revised 06130117
OCT 14 2021
FORM R405-2020
FLORIDA ENERG F ( EI ; (, ILDING CONSTRUCTION
Florida Department o si ' ss a` �Pr "fies na s R gul ; i ` esidential Performance Method
Project Name: Lot 33 Block 2 Waterstone 2265 AGL Builder Name: ADAMS HOMES
Street: 8501 Waterstone Boulevard Permit Office:
City,State,Zip: Port Saint Lucie,FL,3495 _Permit Number:
urisdiction: 661000
Owner:. 'L '
Design Location: FL,ST_LUCIE_CO_INTL County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Typeo1994.2 sqft.) Insulation Area
a.Concrete Block-Int Insul,Exterior R=4.1 . 1378.30 ft2
2. Single family or multiple family Detached
b.Frame=Wood,Exterior R=13.0 407.83 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 208.00 ft2
4. Number of Bedrooms 4 d.N/A R=, ft2
11.Ceiling Types (2357.0 sqft.) Insulation Area
5. Is this a worst case?. No a.Under Attic(Vented) R=30.0 2277.00 ft2
6. Conditioned floor area above grade(ft2) 2277. b.Knee Wall(Vented) R=10.0 80.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
7. Windows(273.9 sqft.) Description Area 12.Ducts R ft2
a.Sup:Attic,Ret:Main,AH:Main 6 456.2
a. U-Factor: Dbl,U=0.33 154.00 ft2
SHGC: SHGC=0.23
b. U-Factor. Dbl,U=0.33 66.00 ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21 a.Central Unit 34.8. .SEER:16.00-
c. U-Factor: Dbl,U=0.55 35.56 ft2
SHGC: SHGC=0.70 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 5.043 ft.
Area Weighted Average SHGC: 0,292• a.Electric 33.0 HSPF:9.00
Heat Pump.
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15.Hot water systems
SHGC(AVG): N/A a. Electric Cap:40 gallons
9. Floor Types (2277.0 sqft.) Insulation Area EF:0.940
a.Slab-On-Grade Edge Insulation R=0.0 2277.00 ft2 b. Conservation features
b.N/A R= ft2. None
c.N/A R= ft2 16.Credits Pstat
Total Proposed Modified Loads: 63.67 PASS
Glass/Floor Area: 0.120 Total Baseline Loads: 66.97 PASS
I hereby certify that the plans and specifications covered by Review of the plans and 0� S�ArF
this calculation are in co liance with the FI da Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. ti"
PREPARED BY: Before construction is completed
DATE: this building will be inspected for '` i
compliance with Section 553.908
I hereby certify,that this building, as designed, is in compliance Florida Statutes. „'F' �y�S
CAD
with the Florida.Zper Write
OWNER/ V BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402A.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Lot 33 Block 2 Waterstone 22 Bedrooms: 4 Address Type: - Lot Information
Building Type: User Conditioned Area: 2277 Lot# 33-2
Owner Name: Total Stories: 1 Block/Subdivision: Waterstone
#of Units: 1 Worst Case: No PlatBook:
Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8501 Waterstone Boule
Permit Office: Cross Ventilation: No County: St. Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Port Saint Lucie,
Family Type: Detached FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location, TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture .Range
FL,ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number Name Area Volume
1 Blockl 2277 20493
SPACES
Number Name Area Volume Kitchen - Occupants Bedrooms InfillD. Finished Cooled Heated
1 ' Main 2277 20493 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type. Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 206.2 ft 0 2277 ftz 0.35 0 0.65
ROOF
l Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. 'Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 2546 ftz 570 ftZ Medium N 0.86 N 0.85. No 0 26.57
ATTIC
V # Type Ventilation_ Vent Ratio(1 in) Area RBS _ IRCC
1 Full attic Vented 300 2277 ftZ N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main- 30 Blown 2277 ftZ 0.11 Wood
2 Knee Wall(Vented) Main 19 Double Batt 80 ftZ 0.11 Wood
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00:FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent " Space Cavity Width Height Sheathing Framing Solar Below
0
1 NE Exterior Frame-Wood Main 13 10 2 8 0 81.3-ft2 0 0.23 0.6 0
2 NE Exterior Concrete Block-Int Insul Main 4.1 38 7 10 0 385.8 ftZ 0 0 0.6 0
3 NW Exterior Frame-Wood Main 13 4 6 10 0 45.0 ftZ 0 0.23 .0.6 0
4 NW Exterior Concrete Block-Int Insul Main 4.1 28 6 10 0. 285.0 W 0 0 0.6 0
_5 SW Exterior Frame-Wood. Main 13 6 9 8 0 54.0 ftZ 0 0.23 '0.6 0
6 SW Exterior Concrete Block-Int Insul Main 4.1 50 3 8 0 402.0 ftz 0 0 0.6 0
7 S Exterior Frame-Wood Main 13 3 10 10 0 . 38.3 ft2 0 0.23 0.6 0
8 S Exterior Concrete Block-Int Insul Main 4.1 0 5 10 0 4.2 ft2• 0 0 0.6 0
9 SE Exterior Frame-,Wood Main 13 18 11 10 0 1892 ftZ 0 0.23 0.6 0
10 SE Exterior Concrete Block-Int Insul Main 4A 37 8 S 0 301.3 ftZ 0 0 0.6 0
11 Garage Frame-Wood.. Main 13 26 0 8 0 208.0 ftZ 0 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 NW Insulated Main None .25 3 6 8 20 ftZ
2 - Wood Main None. .25 2 8 6 8 17.8 ftZ'
3 SW Insulated Main None .25 2 8 6 8 17.8 ftz
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 NE 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftZ 23 ft 0 in 0 ft 9 in Drapes/blinds None
2 NE 2 Vinyl Low-E Double Yes 0.33 0.23 N. 30.0 ftZ 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
3 NW 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft' 7 ft 8 in 0 ft 6 in None None
4 NW 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft- 7 ft 8 in 2 ft 10 in None None
5 NW 4 Vinyl Low-E Double Yes 0.33 0.21 N 30.0 ftZ 1 ft 0 in 0 ft 10 in Drapes/blinds- Exterior 5
6 NW 4 Vinyl Low-E Double Yes 0.33 0.21 N 36.0 ftZ 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5
7 SW 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.0 ft' 1 ft 0 in 0 ft 10 in 'Drapes/blinds Exterior 5
8 SW 6 Vinyl Low,E Double Yes 0.33 0.23 N 15.0 ftZ 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
9 S 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft' 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5
10 SE 9 Vinyl Low-E Double 'Yes 0.55 0.7 N 17.8 ftZ 9 ft 4 in 0 ft 9 in Drapes/blinds None
11 SE 9 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft' "6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5
12 SE 9 Vinyl Low-E Double - Yes 0.33 0.23 N 30.0 ftZ 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5
13 SE 10 Vinyl Low-E Double Yes 0.33. 0.23 N 45.0 ft' 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 617ft2 617ft2 64ft 9ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004 2390.9 131.17 246.26 .1324 7
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split Singl HSPF:9 33 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency, Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER:16 34.8 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.94 40 gal 62.3 gal 120•deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
----Supply---- ----Return-- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1
9/27/2021 9:50 AM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin ]Jan Feb Mar [ ]A r i
Ma ri
Jun ri
Jul X AugX]Se [ ]Oct [ ]Nov H
Dec
Heating f X]Jan Feb Mar []Apr I
May Jun Jul Auj ]SeP [ ]Oct [ ]Nov Dec
Ventin [ ]Jan Feb X Mar [X]Apr May Jun Jul Aug [ ]Se [X]Oct [X]Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80- 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-F[aRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5
z
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index,the more efficient the home.
8501 Waterstone Boulevard, Port Saint Lucie, FL, 34951
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1378.30 ftz
b.Frame-Wood,Exterior R=13.0 407.83 ft
3. Number of units,if multiple family 1 c. Frame-Wood,Adjacent R=13.0 208.00 ftZ
4. Number of Bedrooms 4 d.N/A R= ftZ
5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 2277.00 ftZ
6. Conditioned floor area(ftZ) 2277 b.Knee Wall(Vented) R=19.0 80.00 ftZ
7. Windows- Description Area c.N/A R= ftZZ
a. U-Factor: Dbl,U=0.33 154.00 ftZ 12.Ducts,location&insulation level R ft
a.Sup:Attic, Ret:Main,AH:Main 6 456.2
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.33 66.00 ftZ
SHGC: SHGC=0.21 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.55 35.56 ftZ a.Central Unit 34.8 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: other(see details) 18.33 ftZ 14.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Heat Pump 33.0 HSPF:9.00
Area Weighted Average Overhang Depth: 5.043 ft.
Area Weighted Average SHGC: 0.292
8. Skylights Description Area 15.Hot water systems Cap:40 gallons
a. U-Factor(AVG): N/A ftZ a. Electric EF:0.94
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 2277.00 ftZ Credits(Performance method) Pstat
b.NIA R= ftZ
c.NIA R= ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building �14E Sr
Construction through the above energy saving features which will be installed (or exceeded) ,y04- _ '���0
in this home before final inspection. Otherwise, a new EPL Display Card will be completed yk+", ``` �_'
based on installed Code compliant features.
Builder SijnatUre: � _ Date: c7 n
Address of New Home: City/FL Zip:
coD WE
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
CJ C"f 14 z021
I S1 i_ucie County, Pan-niltl
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
q' Y
FI'r� :e ar nt ' f s"end ;r:` Tonal Regulation
Simulated Pe ormanc Alt a 1v (P 'rf ance) Method
Applications for compliance with the 2020 Florida Building Code,Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form,R405-2020 report FILE PY
❑ Input summary checklist that can be used for field verification (usually four pages/may be greater)
❑ Energy Performance Level(EPL)Display Card(one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ . Mandatory Requirements(five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1-one page)
❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5
❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed
2020 Duct Leakage Test Report-Performance Method(usually one page)
9/27/2021 9:50:16 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 8501 Waterstone Boulevard Permit Number:
Port Saint Lucie,FL,34951
MANDATORY REQUIREMENTS -See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
❑ (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturers instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures:
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Uslm2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R402.4A Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,
including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise
sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire
system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the'ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where Qn=
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are
installed,they shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall
be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
❑ R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a .
downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60°C).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.'A separate valve shall be provided to permit the energy supplied to the main bumer(s)of
combustion types of service water-heating systems to be turned off.
❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system.shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for.Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical
ventilation,the air handler shall be powered by an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment.
R403.7.1 Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the
outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other
factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU
(CFM) (CFM/WATT) (CFM)
HRV or ERV Any 1.2 cfm/watt Any
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by aFlorida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
El shall
Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity an an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF(4.8°C).
❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5
^ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
u the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. .
❑ R403.10.4 Gas-and oil-fired pool'and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56:Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in'accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
DR403.13 Dehumidifiers(Mandatory If installed,a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. . If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
E] R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall,have an
efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 5
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot 33 Block 2 Waterstone 2265 AGL Builder Name: ADAMS HOMES
Street: 8501 Waterstone Boulevard Permit Office:
City,State,Zip: Port Saint Lucie,FL,34951 Permit Number: U
Owner: Jurisdiction: 661000 2
Design Location: FL,ST_LUCIE_CO_INTL v
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall .
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
cavities shall be filled by insulation that on
Narrow cavities installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and Wring
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
extedorwalls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler rnver plates i2nd walls or reelm
a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
9/27/2021 9:50 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000 Permit#:
Job Information
Builder: ADAMS HOMES Community: Lot: 33-2
Address: 8501 Waterstone Boulevard
City: Port Saint Lucie State: FL Zip: 34951
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
O PRESCRIPTIVE METHOD-The.building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2.
.0 PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50)value,as.shown on Form R405-2020(Performance)or R406-2020(ERI),section labeled as infiltration,sub-section ACH50.
ACH(56)specified on Form R405-2020-Energy Calc(Performance)or.R406-2020.(ERI): 7.000
x 60 _ 20493 — Method for calculating buildinq volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
F-1 PASS is Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control
measures.
3.Interior doors,if installed at the time of the test,shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: Issuing Authority:
9/27/2021 9:50:34 AM EnergyGaugeO USA 7.0,00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
DEL-- NOVE
AIR Manual S Compliance Report Jab: Block 2 Waterstone...
� Date: OVEMBER 3,2010
xEMNU•ate COMMON= Entire House By: DCS
DEL-AIR HEATING AND AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665
Project • •
For: ADAMS HOMES
8501 Waterstone Boulevard,Fort Pierce,FL34951
Cooling Equipment
Design Conditions
Outdoor design DB: 90.4°F Sensiblegain: 26215 Btuh Entering coil DB: 76.5°F
Outdoor design WB: 77.4OF Latent gain: 5116 Btuh
9 Entering coil WB: 63.3°F
Indoor design DB: 75.0 OF Total gain: 31331 Btuh
Indoor RH: 50% Estimated airflow: 1160 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Trane Model: 4TWR6036H1+TEM6AOC36H31++TDR
Actual airflow: 1160 cfm
Sensible capacity: 28872 Btuh 110%of load
Latent capacity: 5246 Btuh 103%of load
Total capacity: 34118 Btuh 109%of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 41.0°F Heat loss: 29493 Btuh Entering coil DB: 69.5OF
Indoor design DB: 70.0 cF
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Trane Model: 4TWR6036H1+TEM6AOC36H31++TDR
Actual airflow: 1160 cfm
Output capacity: 29510 Btuh 100%of load Capacity balance: 37 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1160 cfm
Output capacity: 7.8 kW 90%of load Temp.rise: 21 OF
Meets all requirements of ACCA Manual S.
wrightsoft, 2021-Sep-27 09.48:54
�• •w�- ��, Rigtt-Sute®Uriversal 2021 21.0.07 RSU24004 Page 1
265AGL\Lot33Blk2Waterstore2265AGL TraneAlt.np CaIc=MJ8 Horsefaces:NW
i
Component Constructions Job: Lot 33 Block 2Waterstone...
DEL-AIR P Date: NOVEMB ER 3,201•
HEATING•AIR CONDmOM. Entire House By Dcs
DEL-AIR HEATING AND AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665
Project • •
For: ADAMS HOMES
8501 Waterstone Boulevard,Fort Pierce,FL34951
Design Conditions
Location: Indoor: Heating Cooling
St Lucie Co Intl,FL,US Indoor temperature(OF) 70 75
Elevation: 26 ft Design TD(OF) 29 15
Latitude: 28°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9
Dry bulb(OF) 41 90 Infiltration:
Daily range(OF) - 15 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
W BluMtz°F ft"FBtuh BtuWft' Btuh M&W Btuh
Walls
12C-Osw:Frm wall,stucco ext,3/8"wood shth,r-13 cav ins, 1/2"gypsum ne 63 0.091 13.0 2.64 167 2.21 140
board int fnsh,2N4"wood frm,16"o.c.stud se 129 0.091 13.0 2.64 339 2.21 284
s 26 0.091 13.0 2.64 68 2.21 57
SW 36 0.091 13.0 2.64 95 2.21 80
nw 13 0.091 13.0 2.64 35 2.21 29
all 267 0.091 13.0 2.64 704 2.21 590
16B-19ad:Knee wall,asphalt shingles roof mat,r-19 kw ins,1/2"gypsum ne 20 0.049 19.0 1.42 28 2.59 52
board int fish se 20 0.049 19.0 1.42 28 2.59 52
sw 20 0.049 19.0 1.42 28 2.59 52
nw 20 0.049 19.0 1.42 28 2.59 52
all 80 0.049 19.0 1.42 114 2.59 207
Blk wall,stucco ext,r-4 ext bd ins;8"thk,1/2"gypsum board int fnsh ne 356 0.201 4A 5.83 2075 4.06 1445
se 256 0.201 4.1 5.83 1492 4.06 169
s 4 0.201 4.1 5.83 25 4.06 17
sw 378 0.201 4.1 5.83 2203 4.06 1535
nw 212 0.201 4.1 5.83 1237 4.06 862
all 1207 0.201 4.1 5.83 7033 4.06 4899
Partitions
12C-Osw.Frm wall,1/2"gyp.bd ext,r-13 cav ins,1/2"gypsum board int 242 0.091 13.0 2.64 639 1.31 317
fnsh,2N4"wood frm,16"o.c.stud
Windows
10C-v:2 glazing,clr low-e outr,air gas,vni frm mat,dr innr,1/4"gap,1/8" ne 18 0.550 0 16.0 285 30.6 546
thk;NFRC rated(SHGC=0.70);50%drapes,medium;23 ft overhang(6.7
ft window ht,0.75 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8" ne 30 0.330 0 9.57 287 17.7 531
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1 ft overhang(5 ft se 45 0.330 0 9.57 431 16.5 743
Window ht,0.83 ft sep.);6.67 ft head ht sw 15 0.330 0 9.57 144 16.5 248
all 90 0.330 0 9.57 861 16.9 1522
10C-v:2 glazing,clr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" se 18 0.550 0 16.0 285 12.6 226
thk;NFRC rated(SHGC=0.70);50%drapes,medium;9.33 ft overhang
(6.7 ft window ht,0.75 ft sep.);6.67 ft head ht
wrightsoft- 2021-Sep-27 09:48:54
+w•• •• -�=m m. Right-Sute®Uriversal 2021 21.0.07 RSU24004ACCK Page 1
265AGLLot33Blk2Walerstore2265AGL_TramAlt.rLp Calc=MJB Hotsefaces:NW
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8" se 13 0.330 0 9.57 120 8.52 107
fhk;NFRC rated(SHGC=0.23);50%drapes,medium;6.67 ft overhang(5
ft window ht,0.33 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" se 30 0.330 0 9.57 287 8.52 256
thk;NFRC rated(SHGC=0.23);50%drapes,medium;9.33 ft.overhang(5
ft window ht,0.33 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" s 13 0.330 0 9.57 120 8.52 107
thk;NFRC rated(SHGC=0.23);50%drapes,medium;11 ft overhang(5 ft
window ht,0.33 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,dr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" sw 9 0.330 0 9.57 86 15.5 140
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1 ft overhang(3 ft
window ht,0.83 ft sep.);6.67 ft head ht
2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" nw 5 0.330 0 9.57 48 26.3 132
thk;NFRC rated(SHGC=0.31);7.67 ft overhang(1 ft window ht,0.5 ft
sep.);6.67 ft head ht
2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr, 14'gap,1/8" nw 7 0.330 0 9.57 64 22.1 148
thk;NFRC rated(SHGC=0.31);50%drapes,medium;7.67 ft overhang
(6.7 ft window ht,2.83 ft sep.);6.67 ft head ht nw 7 0.330 0 9.57 64 22.1 148
all 13 0.330 0 9.57 128 22.1 296
2A-2ov:2 glazing,cir low-e outr,air gas,vnl frm mat,cir innr,1/4'gap,1/8" nw 30 0.330 0 9.57 287 16.6 498
thk;NFRC rated(SHGC=0.21);50%drapes,medium;1 ft overhang(5 ft
window ht,1.33 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,14'gap,1/8" nw 36 0.330 0 9.57 345 16.6 598
thk;NFRC rated(SHGC=0.21);50%drapes,medium;1 ft overhang(6 ft
window ht,2.83 ft sep.);6.67 ft head ht
Doors
11 J0:Door,mtl fbrgl type sw 18 0.600 6.3 17.4 311 17.6 314
nw 20 0.600 6.3 17.4 350 17.6 353
all 38 0.600 6.3 17.4 661 17.6 667
Ceilings
1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 2322 0.032 30.0 0.93 2154 1.69 3922
gypsum board int fnsh
Floors
22A-tpl:Bg floor,light dry soil,on grade depth 232 0.989 0 28.7 6659 0 0
I
I
I
iJ. WrilghtsOftN 2021-Sep-2709:48:54
Bight-Sute®Uriversal2021 21.0.07 RSU24004 Page 2
14CA:�k ...265AGLtLot33Blk2Waterstcre2265AGL_TraneAlt.nQ Calc=MJB Hoisefaces:NW
a Pro ectSumma Job: Lot 33 Block 2 Waterstone...
QEL-AIR 1 ry Date: 14OVEMBER 3,2010
HG•wa coeam010111 Entire House By: DCS
DEL-AIR HEATING AND AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665
Proeect Information
For: ADAMSHOMES
8501 Waterstone Boulevard,Fort Pierce,FL34951
Notes: HAupdate 5/14/14
RVSD 8-20-15 JA
L.S 8-11-16 JTW
L.S 8-16-16 JTW
Design Information
Weather: St Lucie Co Inti,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 41 OF Outside db 90 cF
Inside db 70 OF Inside db 75 cF
Design TD 29 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 57 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24790 Btuh Structure 19788 Btuh
Ducts 4703 Btuh Ducts 6427 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 29493 Btuh Use manufacturer's data y
Rate/swingg multipplier 1.00
Infiltration Equipmentsensibleload 26215 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3544 Btuh
Ducts 1572 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ft3) 2277 2277 Equipment latent load 5116 Btuh
Volume(ft3) 20789 20789
Air changes/hour 0.36 0.19 Equipment Total Load(Sen+Lat) 31331 Btuh
Equiv.AVF(cfm) 125 66 Req.total capacity at 0.75 SHR 2.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade TRANE Trade TRANE
Model 4TWR6036H1 Cond 4TWR6036H1
AHRI ref 7562981 Coil TEM6AOC36H31++TDR
AHRI ref 7562981
Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER
Heating input Sensible cooling 26100 Btuh
Heating output 33000 Btuh @ 47OF Latentcooling 8700 Btuh
Temperature rise 26 OF Total cooling 34800 Btuh .
Actual airflow 1160 cfm Actual airflow 1160 cfm
Airflowfactor 0.039 cfm/Btuh Airflowfactor 0.044 cfm/Btuh
Static pressure 0.30 in H2O Static pressure 0.30 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point=37 OF
Input kW, Output=26611 Btuh,100 AFUE
Calculations approved byACCAto meet all requirements of Manual J Sth Ed.
-�- wrightsoit' 2021-Sep-27 09:48:54
•- •^•-•r�ma-, Right-Sute®Universal 2021 21.0.07 RSU24004 Page 1
ACCK 265AGL\Lot33Blk2WatersbrL-2265AGL_TraneAlt.np Calc=W8 Hoisefaces:NW
it
'1' DEL-AIR Right-M Worksheet Job: Lot 33 Block 2Waterstone22...
VMMG•AMCGIi0MGM Entire House Date: NOVEMBER 3,2010
By: DCS
DEL-AIR HEATING AND AIR
531 CODISCO WAY SANFORD,FL 32771 Phhoo ONDITI ONI NG
1 Room name Entire House MBR
2 Exposed wall 2322 It 40.0 It
3 Room height 9.0 ft d 8.0 ft heaV000l
4 Room dimensions 1.0 x 268.0 ft
5 Room area 2321.5 tF 268.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (it') Load
number (Btuh/ftz-°l (Btuh/itz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 4)! 12C-Osw 0.091 ne 2.64 221 -81 63 167 140 a 81 63 -167 140
L ___G 1OC-v __ 0550 ne 1525 ._ 30,55 18 0 285 546 - _ 18_ 0 285. 546
W 16B-19ad 0.049 ne 1.42 259 20 20 28 52 _ 0 0 0 0
y Blk vsll,stucco ext 0.201 ne 5.83 4.06 386 356 2675 1445 0 0 0 6
11 L-G 2A-2ov _- 0330 ne 957 _ 17.70 30 _ 0 287 531 0 0 0 0
12C-Osw 0.091 se 2.64 221 189 129 339 284 0 0 0 0
10C-v 0.550 se 15.95 12.64 18 18 285 226 0 0 0 0
2A-2ov 0,330 se 9.57 852 13 13 120 107 0 0 0 0
2A-2ov 0.330 se 9.57._. . 8.52 .30 .... 30 .... _ 287 256 .0 _0 _ ._ -0 .. 0
W 1613-19ad 0.049 se 1.42 259 20 20 28 52 0 0 0 0
V)1 Blk v,all,stucco eM 0.201 se 5.83 4.06 301 256 1492 1039 120 90 525 365
L---G 2A-2ov 0230 se 957 16.51 45 7 431 743 30 5 287 495
W 12C-Osw 0.091 s 2.64 221 38 26 68 57 0 0 0 0
I-_ G 2A-2ov 0.330 s 957 __ 852 13 13 120 107 0 0 0 0
_
W Blk Nall,stucco-ext 0.201 s 5.83 4.06 4 4 25 17 _0 0 0 0
Vtl 12C-Osw 0.091 sw 2.64 221 54 36 95 80 0 0 0 0
t--_--D 11JQ 0.600 sw _17AO_ -1758 18 - 18 311 314 .- 0 ..0 0 0
W 16B-19ad 0.049 sw 1.42 2.59 20 20 28 52 _ 0 0 _ 0 0
Vi1 Blk mail,stucco ext 0.201 sw 5.83 4.06 402 378 2203 1535 128 128 746 520
2A-2ov 0,330 sw 957 1551 9 2 86 140 0 0 0 0
2A-2ov 0.330 sw 957 1652 15 2 144 248 0 0 0 _0
12C-Osw 0A91 nw 2.64 221 45 13 35 29 0 0 0 0
2B-2fv 0.330 nw 957 26.32 5 0 48 132 0 0 0 0
213-21y 0.330 nw 9.57 22.09 7 0 64 148 0 0 0 0
11J0 0.600 nw 17AO 1758 20, 20 350 353 0 0 0 0
0.049 nw 1.42 - 2.59 .. - 20-__.. 20
V. 1.6G19ad_. _.�. 26 52 0 . 0 ,. 0 0
Blk xell,stucco ext 0.201 nw 5.83 4.06 285 212 1237 862 0 0 0 0
2A-2ov 0.330 nw 957 16.61 30 0 287 498 0 0 0 0
2A-2ov 0.330 nw 957 16.61 36 0 345 598 0 0 0 0
2B-2ty 0.330 nw 9.5.7 22.09 7 0 64 148 0 0 0 0
P _ _ 12C-Osw _ 0.091 2.64 _ 1.31 242 242_ 639 317 0 0 0. 0
C 16B-30ad 0.632 0.93, 1.69 2322 2322 2154 3922 268 268 249 453
F, 22A-tpl 0.989 28.68 _ 0.00 _ 2322 232 6659 0 268 1 40 .1147 0
6 c)AED excursion 96 -42
Envelope loss/gain 20814 15124 3405 2476
12 a) Infiltration 3975 1114 701 196
b) Roomventilation 0 0 0 0
13 Internal gains: Occupants@ 230 5 1150 1 230
Applianoes(other 2400 1 600
Subtotal(lines6 to 13) 24790 19788 14106 3503
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 24790 19788 4106 3503
15 Dud loads 19% 32% 4703 6427 19% 32% 779 1138
Total room load 29493 26215 4885 4641
Air required(cfm) 1 1160 1160 192 205
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-P�1 wrigt�tsoft^ 2021-Sep-2709:48:54
AG�A Right-Sute®U iversal2021 21.0.07 RSU24004 Page 1
265AGL1Lot33Blk2Waterstone2265AGL_TraneAlt.r p Calc=MJ8 Hoisefaces:NW
'1 DEL-AIR Right-M Worksheet Job: Lot 33 Block 2 Waterston 22...
1�lIIUic•AM c01Mma1@Ic Entire House Date: NOVEMBER 3,2010
DEL-AIR HEATING AND AIR By: DCS
CONDITIONING
531 CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665
1 Room name WIC 1 WIC 2
2 Exposed wall 7.0 ft 0 It
3 Room height 8.0 ft heatbool 8.0 ft heatbool
4 Room dimensions 6.0 x 7.0 ft 5.0 x 7.0 It
5 Room area 42.0 ft2 35.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ft) Load
number (Btuh/ft-9 (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P5 Heat Cool Gross N/P/S Heat Cool
6 V�! 12C Osw - - -- 0.091 ne 2.64 221 _____. ._0-___ _.O -__._._O O.__. __.0 --__._O.---- -.. .0 . ._._.: 0
L_-_G_10C-v---__---__-_- _05,50._ne- 1595.. 3055 _ .___.. 0 _- - 0.- _0 _ _ 0 _-0 0._- --._ 0 0
W 16B-19ad 0.049 _ne 1.42 2,59 0 0 0 0 0 0 0 0
BlkHell,stti000e>Q- 0201 ne 583 - 4.06 _ 0 ---- _ 0 - __.6 _.0. ____ O -0 - 0 - 0
11 2A-2ov--- 0.330_ne 957 17.70_ _ -..__0
12C-Osw 0.091 se 2.64 221 0 p - ---p 0 --.._-__ 0 00 _ 0
0 __00
10C-v 0550 se 15.95 12.64 0 0 0 0 0 0 0 0
2A-2ov 0.330 se 9.57 852 0 0 0 0 0 0 0 0
2A2oy_... 0.330 _� -. .._9S7 .-852 __.. 0 ..__. _ 0_._ .__..._0 . __ 0_.,...___ -0 ._.. .... Q -- 0 __...__...0
W 166 19ad --_ _0.049 se 1.42, 259 0 __.._ _._0 _�.-__Q _ -.-- _. -0 -_._ .0 _ _ ....0____._ .. 0- _ 0
BIk vtall,stucco ext 0.201 se 5.83 4.06 0 6 0 0 0 0 0 0
2A-2ov _._.. _ _0.330 se_ _ 9.57 _ 1651 _ - ---.0 ._--- -. 0 -__------0 - - --.0 -_.----0 - - - 0---- 0 _ 0-
12C Osw 0.091 s 2.64 221 0 0 0 0 0 0 0 0
2A-20v___ ._ ___ -_ _ _ 0330 s 957 _- _852 -0. _ ._.0 _ _.-._ 0 0 __._ - _0 0 __ .0 _ . 0
W BIk vtell,st_uo_oo e d 0.201 _s 5.83 _ 4.06 0 0 0 0 0 0 0 0
Vf/ 12C-Osw _. _ _ _0.091 sw 2.64- 221 __0 _O __....- --0---- ._0 ._ _- .--0- _--..0 .-__-- -0 - .. _._0
_ - 114 0.600 sw _17.4.0, - .1758
_. .0 _ -_ _.0 0 ..... -.0..- 0.._. .. 0 . ._ .._._Q
W 16B 19ad 0.049 sw 1.42 _ _ 2S9 0__ 0 0 0 0 0 0 0
Blkwall,stucco exi 0.201 sw 5B3 4.06 56 56 326 227 - 0 0 --`- 0 6
2A-2ov 0.330 sw 957 1551 0 0 0 0 0 0 0 0
2A-2ov 0.330 sw 957 1652 0 0 0 0 0 0 0 0
12C-Osw 0.091 nw 2.64 221 0 0 0 6 0 0._._ _ 0 0
213-2N 0.330 nw 957 2632 0 0 0 0 0 0 0 0
28-2N 0.330 nw 9,57 22.09 0 0 0 0 0 0 0 0
_._ 11J0,. .___..--_- _0,600 .nw 17.40 . 1758 , 0 0 0. - 0 __ -. 0 0 0 0
16B'19ad._.__.___ -.0,049. nw ._. 1.42._._-_2.59 _..,9. ._.__.-_. 0 _._.__.._0_ _ 0 .._.._._._. 0 _.. __ .0__._ _._ 0 _ .,.-0
BIk wall,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0.330 nw 9.57 16.61 0 0 0 0 0 0 0 0
2A-2ov 0.330 nw 9,57 16.61 0 0 0 0 0 0 0 0
2B-2fv_,-,,_,_ -- _ -- 0,330 nw _ 957_ 22.09 _- __ -0 0 0 _0 0 . __. __ _ 0 _ _ 0
P -- 12C-0sw_. ___ _ 0.091....- 2.64 _1.3.1 - - _
C 16B-30ad _- . 0.032-. - 0.93_ _ 1.69 42 42 39 71 35 __ 35 32 59
F_ _. 22AWL _. 0989 28,68 _- _0.00 _ ._ -42 _.-._ 7 -0 35 ._ 0 0 0
6 c)AED excursion -18 -3
Envelope loss/gain 566 281 32 56
12 a) Infiltration 119 33 0 0
b) Room ventilation 0 0
0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Applianoesbther 0 0
Subtotal(lines6 to 13) 686 314 32 56
Less external load 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 686 314 32 56
15 Ductloads 19% 32% 130 102 19% 32% 6 18
Total room load 816 416 39 74
Air required(cfm) 32 18 2 3
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
-Pi.F wrightsoft�
........ Right-SuteOUriversal202121.0.07RSU24004 2021-Sep-2709:age2
54
�� Page 2
...265AGL�Lot3361k2Waterstore2265AGL_TraneAltnp CaIc=MJB Hoisefaces:NW
DEL--AIR Right-J®WOPkShe@t Job: Lot33 Block 2 Waterston 22...
own-Amcmmmarmr. Entire House Date: NOVEMBER 3,2010
By: DCS
DEL-AIR HEATING AND AIR
QNING
531 CODISCO WAY,SANFORD,FL 32771 PCOND333 22665
1 Room name MBATH WC
2 Exposed wall 11.0 It O ft
3 Room height 8.0 It heat/cool 8.0 It heaticool
4 Room dimensions 1.0 x 140.0 It 1.0 x 25.0 ft
5 Room area 140.0 tF 25.0 112
Ty I Construction U-value Or HTM Area (ft') Load Area (ftz) Load
number (Btuh/ftz-`F) (Btu ) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 UW Y 12C 0sw OA91 Y ne 221 -- 0 -0 - 0 - 0 0 0 -- - 0 -- - 0
0550-ne 1-5,95___3055 _.__.__.0 ___ 0 0 --_--_---0..____-._.. 0 ._-__0
W 1613-19ad _- 0049 ne_ ._ _1,422 259 0 0 0 _ __.._0 0 .. ...___., 0. 0
VN- Blk vtall,stu000 eM 0.201 ne 5 83 4 06 �' 0 -0 v' 0 6 A 0 0 0
0.330..De --957 0 - - 0 - - Q _9__._- __0
12C-Osw 0.091 se 2.64 221 0 0 0 0 0 0 0 0
10C-v 0550 se 15.95 12.64 0 0 0 0 0 0 0 0
2A2ov 0.330 se 957 852 0 0 0 0 0 0 0 0
0230 -_se-- _ 9.57 852 0 0 __._a. ._0 _.__0_.._.___0.___.__�0__. _.____0 __._.__.0.
0.0.9 se. __._1.42_. _259 0
VjJ Blk wall,stucco ext 0.201 se 5B3 4.06 0 0 0 0 0 0 0 0
------G 2A-2ov--- - - - - 0330 ---9.57___1651 --- 0 - -0 --- Q - --_0--- -0 - -
12C-Osw 0.091 s 2.64 221 0 v 0 0 0 0 0 O 0
__._ 2A-2ov_..__ _...-- --_ -_a--.0.330 __s. .957._ _852 _.._...0 ___-__-_0 _______0 _--_.0._........___0--_. 0_ .._.--_ 0 ___._.0
W Bilk yell,stuo�u ext _,-___0.201 s 5.83 4.06 0 0 0 0 0 0 0 0
T-.-_ .
12C-Osw 0.091 siiv T 2.64 221 0 - _0 ___ 0 ._ _._O _ _ 0
_ --. 11J0_ -.__„ _.__ 0600 .sw- 17AO 1758 - _ ._ .0 ._ . _ -0 ___.-- _0 -- _ .0__- __0_. _ _0_ _ ._-
.- 0 - 0
W 16B-19ad _0.049 -SW
1.42..._ 259 --. .._0 -_ - -0 0. -0 - .. 0 - - 0.- 0--
Blk well,sWcoo eM - 0.201 sw 5 83 4.06 88 79 460 321 . 0 0 0 0
2A-2ov 0.330 sw 957 1551 9 2 86 140 0 0 0 0
2A-2ov, a. _0.330_.sw. 957. ._.__1652 __. 0 .. .._ -_,4_.. 0 _0 - -0 - -_._0 -0 0
12'C-0sw 0.091 nw 2.64 221 0 0 0 0 0 0 0 0
213-2fv 0.330 nw 957 2622 0 0 0 0 0 0 0 0
213-2N 0330 nw 957 22.09 0 0 0 0 0 0 _ 0 0
11J0,_-. _ _. 0600 nw 17AO . r-175B_ -_T .t)._-.---- 0 -_. .......__0 .. 0 _._ 0 . .._.__.0 __. _0 .,. 0
nw. _.,,_1.42_._.. -2 ,. _,��..�0 ,- _'----0....__�,' 0 --------0
Blk v dl,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0330 nw 957 16.61 0 0 0 0 0 0 0 0
2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
2B-21v 0330 nw- ____9.57.__ 22.09 _.._ 0 ___.-._ 0 _ _0 _ ----. _Q,___....__0_.._ _ _9_._ _ -0.._ 0
P- - 12C_-0sw 091 --- -2,64 1 31 _..._: 0 0 0 : _0 - _.-.0 0 _ :0
C_ .._ 16B-30ad - -- 0.032 - 0.93 _.__1.69 - 140 140 _ . .. ._130 - 237 _._?5 23 42
0.989_._.. 28.68 ----0,00 _._.140 _._. _- =11- .. ,_.__315 - 0 25__. 0 _0
6 c)AED excursion 26 -2
Envelope loss/gain 992 723 23 40
12 a) Infiltration 188 53 0 0
b) Room ventilation 0 0 0 0
13 Internal gains Occupants pa 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines6 to 13) 1180 776 23 40
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1180 776 23 40
15 Ductloads 19% 32% 224 252 19% 32% 4 13
Total room load 1403 1027 28 53
Air required(cfm) 55145 1 2
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-P�F wrigtitsoft- 2021-Sep-2709:48:54
Rigl't-Sdte®Udversal 2021 21.0.07 RSU24004 Page 3
265AGLtLot338lk2Waterstore2265AGL-TraneAlLnQ Calc=MJ8 House faces:NW
DEL--AIR Right-M Worksheet Job: Lot 33 Block 2 Waterston 22...
xfmnm•AmCUUMn>mtc Entire House Date- NOVEMBER 3,2010
DEL-AIR HEATING AND AIR By: DCS
531 CODISCO WAY,SANFORD,FL 32771 Pb ON7-3T-2665 G
1 Room name LIV FAM
2 EVosed wall 32.0 ft 24.0 It
3 Room height 10.0 ft heal/cool 10.0 Itheal/cool
4 Room dimensions 15.0 x 12.0 ft 1.0 x 511.5 ft
5 Room areA 180.0 ftz 5115 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/ft2-9 (Btuh/W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/PiS Heat Cool Gross N/P/S Heat Cool
6 12C Osv 0.091 ne - 2.64 ._- 221 - p _- -0 0 _0 - - 0 - -.--0
10C-v -. _ ._0550-ne
W 16B-19a ne d 0.049 142 259 0 0 0 , 0 - 20 20 28 52
_._ _ _._ ..w._-
1?! BIk vtell s*uoco ex< - 0201 ne 5.83 4 06 4 50 50' -w 291 -- 203 -- _p .__._ o __0 -- r_..__.O
11 ----2Q 2ov__ _._____ 0330 ne
12C-Osw 0.091 se 2.64 221 0 0 0 0 144 96 254 213
1OC-v 0550 se 15.95 12B4 0 0 0 0 18 18 285 226
24-2ov 0,330 se 957 852 0 0 0 0 0 0 0 0
2A,2ov _0.330s ._ . . . _- _... _ __- 30 --- 819d _ _ . 0 _, __ 7.W 16B , _ _., �
___ _259_ _v-.J.- 0 0 _ -_-0 _20
.28 ,--,-_-.52
VIi Blk vtdl,stucco e:d 0.201 se 5.83 4.06 0 0 0 0 16 16 93 65
--�-_{_- 2A-2ov_- --. ----------_0330-s 2.64 `-- 221 0 0 0 0 0 0 4- -- p -` -p
L_G 2A-2ov ----_.-0.330 -s.. 957.. _.__...852_�.: __..0 0 _ .. .--0 _-____._0.... .._.__0_----_.. 0_.____ 0
w -, Blk wall,stucco e)d _ _ 0.201 s 523 4.06 0 0 0 0 0 0 0 0
12C-0sw 0'.091 sw 2.64 221 0 0 0 0 .._..._.__0__ _ _O
_ _ 11J0_. ___ - -- -_ 0.600 sw_. _ 17.40 _-- 1758 - _0-� . .-0 ._.. ___ 0 . _ .0 -.- --,-. _0. __0_ 0 ....___ -__0
W 16B 19ad 0.049 sw 142 259 0 0 _ __ 0 0___ 20 ^_ 20 28 52
Blkvall stiocoext 0.201 -sw - 5.83 4.06 - _ 120 105 612 426 0 0 ._.__ _ 0 ... 0
2A-2ov 0.336 sw 957. 1551 0 0 0 0 0 0 0 0
24-2ov -0 330- -957 - _1652 2 144 248:_..--- 0
sw 0
12C-Osnr 0.091 nw 2.64 221 0 0 0 0 45 __ 13 __ _.35 - 29
26.21vv 0.330 nw 957 26.32 0 0 0 0 5 0 48 132
2B-2fv 0.330 nw 957 2209 0 0 0 0 7 0 64 148
11J0 .. 0.600 nw_ _. 1740 1758 0 O 0 0 20 20,. 350.._t.._.353
_--0 ._._.._ .20_._-.__._20_ 28 _52
Blk sell,stud ed 0.201 nw 5.63 4.06 150 120 699 487 35 28 165 115
2A-2ov 0.330 nw 9.57 16.61 30 0 287 498 0 0 0 0
2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
213-2fv .._ - - 0.330 nw _. __957 ._ 22.09. - 0 0 0 _7 _ 0 -� _64..__-._148,
_ 0 _
0 ._.0 Q 0 Q 0
C 16B-30ad 0.032 093. • _e- 1.69 180 180 „--_167 304__--_512 512 475 ._ .--_-864.
F- 22 4 _ ..._. ._.._- 0989 - - 2868.._....-000 - -
160 .__:: $? 918 -_ ...._0 _.. _._5i2 _ __688 -- 0.
_.__ 24
6 c)AED excursion 220 -82
Envelope lossfgain 3118 2386 2921 2673
12 a) Infiltration 682 191 682 191
b) Roam ventilation 0 0
0 0
13 Internal gains; Occupants @ 230 0 0 3 690
Appliances(other 0 0
Subtotal(lines 6 to 13) 3800 2577 3603 3554
Less e)demal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3800 2577 3603 3554
15 Duct loads 19 J 329J6 721 837 191/ 32°/ 684 1154
Total room load 4521 3414 4287 4709
Air required(cfm) 178 151 169 208
Calculations approved by ACCAto meet all requirements of Manual J 8th Ed
-Rk- 2021-Sep-27 09:4854
Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 4
265AGL1Lot33Blk2Waterstore2265AGL_TraneAlt.np Calc=MJB Hoisefaces:NW
DEL--AIR Right-JO WorkSheet Job: Lot 33 Block 2Waterstone22...
xrmmc•nmcormmoxac Entire House Date: NOVEMBER3,2010
DEL-AIR HEATING AND AIR By: DCS
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665
1 1 Room name DIN UTIL
2 Exposed wall 12.0 ft 9.0 ft
3 Room height 10.0 ft heaU000l 8.0 ft heat/cool
4 Room dimensions 11.0 x 11.0 ft 7.0 x 11.0 ft
5 Room area 121.0 ft2 77D ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Btuhfft2-In (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VU- 12C Osni - 0.091 ne 2.64- "221 -- 0 - -----0 -0 ___6_ - __6 --- -- 6___ 6 .. _0
L_-G_ 10C v_-.__ __ .__ 0550 ne- 15.95 3055 0 _ _ _0 - . _ _-0 - _0 __ 0_ _ 0_ 0 _ _ _ _0
W 16&19ad 0.049 _ne 1.42 2.59 0 0 _ 0 0 0 0 0 6
_ Blk vall,.stu000 ext -�_0.201 ne 5.83 4.06 __0 ...__.. 0 6 _O O . _ . _O ._. -0___._,--_O
11 2A-2ov_-- ..... 0.330 ne_. ..__957 -._17.70__...._- 0-- --0 -- 0 0 -- _0 _0 - 0 -0
12GOsw 0. 51 se . 2 0 0 0 0 0 0 0 0
10C-v 0.550 se 15.95 95 12.6.64 0 0 0 0 0 0 0 0
2A-2ov 0.330 so 957 852 0 0 0 0 0 0 0 0
_ 2A2ov-..._ 0330 _se,. 957 ,852 __..._._0____._ .0 ___...__-0 .__ . .__Q_.. ..____0__ . .. _.0 .__._..__0 _....__. ._0.
W _ 16B 19ad ___.. -0.049 se _1 A2 ---_259_-_-__ __0 _.-0 . . ._.__.._0 _- _ _ 0_.__ _ 0 _ 0__. ---_ 0 .. 0
BIk wall,stucco e)d 0.201 se 5.83 4.06 0 0 0 0 0 0 0 0
_-- - 2A_2ov - - 0 330 ,se- 957 _ 1651 - --0 --_-0 0 00 -- 0
t12C-Osw 0.091 s 2.64 221 0 0 - 0 6 0 0 0 0
-.. 2A-2ov_._,-_'w__ 0.330 s - 957_ ___ 85 _2 .----..._..0._--. 0 __.. 0 0 ,._ _ 0 ._ 0 0. 0
W BIk vLell,stucco ext 0.201 s 5.83 4.0.6 0 0 0 0 0 0 0 0
12C Osw _ 0091 -sw 2.64 _._.-221 -0 -- -- .0 0 - 0 -- .... 6 - - - ...0._ __. 0 - -0
_ 11J0_ -- _0.600, sw 17AO,_- 1758 _-- -- 0 __ _0 ._ _0 -- 0.- _-- 0 0 0
W 1613-19ad 0.049 _snr_ 1A 259 0 0 0 0 0 0 0 0
V)J Blkw.all,stucooext -0.201 sw 5.83 4.06'- 10 10 58 4j -6 0 6 _ _.._ 0
I�-GG 2A-20v 0.330 sw 957 1551 0 0 0 0 0 0 0 0
2A-2ov 0.330 sw 957 16,52 _0_ 0 0 0 0 0 0 0
2C 1 -Osw -' 6.691 'nw 2.64 221 0 0 0 - 0 0 0 _O 0
2B-2fv 0.330 nw 957 2622 0 0 0 0 0 0 0 0
213-2ty 0230 nw 957 22.09 0 0 0 0 0 0 0 0
111,10 _ ._. 0.600 nw - ,17.40 1758 0 A_ .-..._.,0 0 _ 0 . _ . .0 --,--0, 0
!N.._. 16B 79.ad - _ 0,049,_nw. 1.42 259 :0 __.. 0 __.__._..._0 --0 ... _0 0 ._. .._ 0 0
BIk well,stucoo ed 0.201 nw 5,83 4.06 100 64 373 260 0 0 0 0
2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
2A-20v 0.330 nw 9.57 16.61 36 0 345 598 0 0 0 0
262(v _... 0330 nw- -- 957_ 22.09 __...._0 ._ ._ 0 ._-._ ..0 0 _ __0 .- 0 0 0
- - ---
- .__ __nQ0sN,_ _ _ .___ 0.09_1 _..- _- 2.64___ __1.31 _10 e-_ --- .10 _...:_26 ---.._13 __72_ _ ._72 190 .._ 94
C 16B-30ad 0.032 0.93 _1.69 121 121- 112 204 77 _ 77 . „ 71 _., -.. 134
_ . _ -
F 0 989 28.68.f 0.00 121 12 3 .0 ..... ._ 77
-- - .9__ 258 .--_._ O
6 c)AED excursion 208 44
Envelope loss/gain 1259 1324 520 181
12 a) Infiltration 234 66 0 0
b) Room ventilation 0 0
0 0
13 Internal gains: Occupants@ 230 1 230 0 0
Applianoeslother 0 600
Subtotal(lines 6 to 13) 1493 1620 520 781
Less extemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1493 1620 520 781
15 Ductloads 19% 320/6 283 526 19%1 329/6 99 254
Total room load 1776 2146 1 1 618 1034
Air required(cfm) 70 95 24 46
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
wrigF�tsoft 2021-Sep-27 09:48:54
AC Right-SUte®Uriversal202121.0.07RSU24004 Pages
265AGLtLot33Blk2Waterstone2265AGL_TraneAlt.rLQ Calc=WB Hosefaces:NW
",DEL-AIR Right-JO Worksheet Job: Lot 33 Block 2Waterstone22...
xurnuc•amcaxnmoroxc Entire House Date: NOVEMBER 3,2010
By: DCS
DEL-AIR HEATING AND AIR
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665
1 1 Room name BATH 2 BR 2
2 wall 6.0 ft 28.0 ft
3 Room height 8.0 ft heai/000l 8.0 ft heat/cool
4 Room dimensions 6.0 x 9.0 It 12.0 x 14.0 ft
5 Room area 54.0 ftz 168.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area z
(ft) Load
number (Btut -fl (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 12C-CF W_ 0.091 ne 2.64 221 -0 0 0 0 0 _ 0 ,. 0 p
10C-v 0,550 ne 15.95 3055 0 0 _0 0 0 0 _ 0 _0
W 16B-19ad 0.049 ne 1.42 259 0 0 0 0 0 0 0 0
yJ Blk v�all,stucco ext0201 ne 5.83 4.06 0 0 0 0 112 97 565 394
11 h _G 2A-2ov _ 0.330 ne 957 _ _ 17.70 0 0 0 0 15 0 _ 144 266
12C-Osw 055 se 5.95 2.6 0 0 0 0 0 0 0 0
10C-v 0550 se 15.95 12.64 0 0 0 0 0 0 0 0
2A-2ov 0230 se 957 852 0 0 0 0 0 0 0 0
2A-2ov.-. 0.330 se. 9.57 _ 8.52 0
0 D 0 0.
W 16B-19ad_ _ 0.049 se 1.42 259 _ 0- 0 0 0_ _ 0 _ 0 - 0 0
Bik wall,stucco ext 0.201 se 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0.330 se 957 1651 0 0 0 0 0 0 0 0
12C-Osw 0.091 s 2.64 221 0 0 0 0 0 0 0 0
2A-2ov 0.330 s 957 852 0 0 0 0 0 0 0 0
W Blk wall,stucco ext 0.201 s 5.83 _ 4.06 0 _ 0 0 0 _ 0 0 0 0
VI!- 12C-0sw 0.091 sw 2.64 221 0 0 0 0 6 0 0 0
�- -D 11J0 0.600 svv 17AO 1758 0 __. 0 _ 0 0 0. 0 _ 0 0
W 16B-19ad 0.049 sw 1.42 2.59 0 0 0 0 0 0 _ 0 0
Blk well,stucco ext 0.261 sw 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0.330 sw 957 1551 0 0 0 0 0 0 0 0
2A-2ov 0 330 svv 9.57 1652 0 0 0 0 0 0 0 0
12C-Osv 0.091 nw 2.64 221 0 0 0 0 0 0 0 0
2B-2fv 0,330 nw 9.57 2622 0 0 0 0 0 0 0 0
2B-2fv 0.330 nw 9.57 22.09 0 0 0 0 0 0 0 0
11J0 0.600 nw 17.40, 1758 _0 0 0 _ 0 0 0 0 0
W 16B-19ad 0.049 nw. 1.42 _ 259 _ 6. __ 0 0 0 0 0 _ 0 0
Blk wall,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0.330 nw 9.57 16.61 0 0 0 0 0 0 0 0
2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
2B-2fv 0 330 nw 957 _ 22.09 0 0 0 0 0 0 _ _ 0 0
P 12C-OsN 0.091 2.64 _ 1.31 48 48 127 63 112 112 296 147
C 16B-Wad 0.032 0.93 1.69 54 54 50 91 168 168 156 284
F 22A-tpl _ _. 0.989 28.68 0.00 LL 54 6 172 0 168 28 803 0
6 c)AED excursion -8 -31
Envelope loss/gain 349 146 1964 1059
12 a) Infiltration 0 0 239 67
b) Room ventilation 0 0
0 0
13 Internal gains: Occupants�la 230 0 0 0 0
Appliancestother 0 0
Subtotal(lines 6 to 13) 349 146 2202 1126
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 349 146 2202 1126
15 Duct loads 19% 32% 66 47 19/ 32% 418 366
Total room load 415 193 2620 1492
Air required(ctm) 16 9 1 T103 66
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
-� wrigF�tsoft- 2021-Sep-270948:54
Righd-Srite®Uriversal 2021 21.0.07 RSU24004 Page 6
265AGL\Lot33Blk2Waterstore2265AGL_TraneAlt.rp Calc=MJ8 Hoisefaces:NW
DEL AIR Right-M Worksheet Job: Lot 33 Block 2 Waterstone 22...
rffnnuc•amcormmormrc Entire House Date: NOVEMBER 3,2010 DEL-AIR HEATING AND AIR By- Dcs
CONDITIONING
531 CODISCO WAY SANFORD,FL 32771 Phore:407-333-2665
1 Room name BR 3 Krr
2 Exposed'mall 14.0ft Oft
3 Room height 8.0 ft heatl000l 10.0 ft heaVcool
4 Room dimensions 1.0 x 158.0 It 1.0 x 154.0 ft
5 Room area 158.0 ft' 154.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/ttz-4) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool
6 12C-09iu --e_---0.091 ne - 2.64 221 0 0 0 __...0....___..___000 O
0550- ne 15.95___3055. ..T__0. -0 0 -.--.----0 .__.._--...0 _._-0 0 0
W _ R-&dl d 0.049 ne _ 1.42 2S9 0 - 0 0 0 0 0 0 - 0
Blk vall,stucco ext 0201 ne 5.83 4.06 112 97 '565 - _394 -0 -- 0 - 0 0
11 2A-2ov- - --0.330 ne- 957 --17.70.. -__--15 -- -- ..0 -----144- - -- 26.6 - 0 0- --0 -0
V� 12C-Osw 0.091 se 2.64 221 0 0 0 0 0 0 0 0
I-G 1OC-v 0.550 se 15.95 12.64 0 0 0 0 0 0 0 0
2A-20v 0.330 se 957 852 0 0 0 0 0 0 0 0
2A 2ov .. . 0 330-_.so. ___957_..___852 _.._.._ ._0. __ .___._0 .._.__ __.A _._.;-------____.0,......_..____0._.____.0. .__ ..._._0
0
W - 16B 19ad_ _ ._ _ w0.049. 9e 1-42 --259 _._0 - - -0 _._Ol -__._._0 0 0 0. _O
Blk yell,stucco ext 0.201 se 5.83 4.06 0 0 0 0 0 0 0 0
-- 2A 2ov 0,330 _se_ ___957 __ 16.51. - --0 -- -0 -- ----. - --- -O 0 0 0 0
W, 12C Osw 0.091 s 2.64 v 221 0 0 0 0 0 0 - 0 0
-L---G 2A 2ov__-___. .-_ .._ _._ ._0.330 s. 957 _._852- _-_,__0 0 0- _- -- 0 _- 0 _0 _. 0 ._..._0
W Blk v dl,stucco ext 0.201 s 5.83 4.06 0 0 0 0 0 0 0 0
V►! 12C Osw - 0.091 sw - 2.64 221 0 _ _0 _ _.0 _._ 0 _ 0_ 0_ . 0 _-0
__._. 11 J0 - -._ _.,_0.600 _sni. 17AO ... 17.58 __._O __. ,O _.. ..._0 _ 0 _ "_ 0..-_ --,-_0 _. _ .. __0 0.
W - 16B-19ad 0049 sw 1.42 2.59 0 0 0 0 0 0 0 0
V� ffik- all,stu000ext - -0201 -sw- _5,B3 4.06 _.__0._______ O __.._ ,.._6 _-- - --.0- __
._._ O,. -.-- b _. _ __6 _. _6
I�-GG 2A 2ov 0.330 sw 957 1551 0 0 0 0 0 0 0 0
2A-2ov_ 0 330 sw 957 _1652_ 0_._ _ -_0.._ _.._.__0 __ 0 0 0 0 0
T5� 12C-Osw - 0.091 nw - 2.64 221 0 0 0 0 - 0 - 0 - 0 - 0
2B-2N 0.330 nw 957 2622 0 0 0 0 0 0 0 0
213-2fv 0.330 nw 957 22.09 0 0 0 0 0 0 0 0
11,10 _. 0.600_nw 17.40 . 1758 0 0 0 _ ._ 0 _0 0 0 0 _.. ___0
W-- -- 166-19ad__. :._ ._ ._ ....__-.0- 9...nw .-1:42 ._259 _.. .--0 -- ---. 0 __..,:__0 _. 0 :_.,:_ „0 __, ..__-0=,-- --.0 ._ i _O
Bilk well,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
2A-2ov 0230 nw 957 16.61 0 0 0 0 0 0 0 0
26-2fv - ______ _ OM'O _nw _ 957 22.09
P-----12GOsv--- - - - -_0.091 - 0. - - 0- 0 _0
------
2.64 131. 0--- 0__ _.__-0 - 0 -O _0 -._. Q 0
C 16B-30ad.
0.032_ - 0.93 1.69_ __. .158 158 _._ 147 267 154 154 _ 143 260
0989_. 28:68__.. 0_00 , _ -...158 .-_.. .14.- _402 __. _. 0 __. 154 _4 _
- o 0
6 c)AED excursion _22 -77
Envelope loss/gain 1257 904 143 183
12 a) Infiltration 239 67 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Oocupanis@ 230 0 0 0 0
Appliancestother 0 1200
Subtotal(lines 6to 13) 1496 971 143 1383
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1496 971 143 1383
15 Duct loads 19% 32% 284 315 19% 32%1 27 449
Total room load 1780 1287 170 1832
Air required(cfm) 70 57 7 81
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
-` wrigF�tsoTt^
Right-Su Paa gelteOUriversal 2021 21.0.07 RSU24004 2021-Sep-27 09:ge 7
Aft ...265AGL1Lot33Blk2Waterstore2265AGL-TraneAlt.np Calc=MJB Housefaces:NW
i
DEL-AIR Ri ht-M Worksheet Job: Lot 33 Block 2Waterstone22...
�mc+a•amcro+mmotaxc 9 Entire House Date: NOVEMBER 3,2010
DEL-AIR HEATING AND AIR By: DCS
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Ptone:407-333-2665
1 Room name BRKFST BATH 3
2 Exposed wall 92 ft 13.0 It
3 Room height 10.0 It heaU000l 8.0 ft heal/cool
4 Room dimensions 1.0 x 142.0 It 1.0 x 76.0 it
5 Room area 142.0 ftz 76.0 ftz
Ty Construction U-value Or HTM (
Area z Area (ftz) Load
number (Btu"2_19 ( z or perimeter Load
(ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross NIPS Heat Cool Gross MPrS Heat Cool
__._ .__....,-.-__. .._...___ ___._._. _. _..__------__-_-___.
6 12C-Osw���--'- _... 0.091 -ne -- 2.64 - _- 221 0 0 0 0. 0 0 0 0
ne_ 15,95 ---3055__._..___0,_-- - 0 - _- _-0 __ -_0.
W 16B-19ad _0.049 _ ne 1 A2 259 0 0 0 0 0 0 0 0
Blkv�all,4666cex<_ -- 0201 ne 5.83..- 4.06 -- - -0 -- -p_. _s_0 _. ___0 _-_ _ _ 0 _ ._ ___.O _
11 2A_2ov__. _-•-.-0______:_0 .._.0 0__. _ ._...0 0 ._._.__ 0
12C-Osw 0.091 se 2.64 221 45 33 86 72 0 0 0 0
_..__
10C-v 0550 se 15.95 12.64 0 0 0 0 0 0 0 0
2A-2ov 0.330 se 9.57 8.52 13 13 120 107 0 0 0 0
2A 2ov_. _-___..___... .___0.330 ._se._ _9.57 ..._ 852 0-_... ._ _0 -__..,__ _0 _ ..__ _0...._._._. .0.. _...__0 __ .._ _...0 __._._._0
---0049 se. - -1.42 M--259 ._0 ._..._ 0 _ ..._._..0 - 0 0 0 ' - 0 - -0
Blk wall,stucco ext 0.201 se 5.83 4.06 5 5 29 20 56 56 326 227
t=G 2A-20v _ . _ 0.330 _se_. ._ _9.57._ _._1651_ _ 0 ._0 0 _0 _ 0 0 0 0
V)/ 12C-0sw 0.091 s 2.64 221 38 26 68 57 0 0 '` -'0 -- 0
2A-2ov - _, _.__ .--_._._0,330 _s. __ ._957. ___852 13 _ .__.__13 ._. .._._120 _ _107-.- _.0_.
_W Blk wall,44gcq ext_ 0.201 s _ _ 5.83 4.06 4 4 25 17 0 - p ' ' - p p
Vjl 12C-0svv 0.091 sw 2.64 221 _- - p - 0 -0 --__--O .--_._.._ ._.__ _36 ---- 95 - 80
�---p_11J0._.__... _.._..._-__ 0.600 _sw 17.40 .n 1758. ._.- >0 ._. ._. _0 ..0 _.. ._ .,,,0.-_..._. ..18 __.. __. _18 _.311 -_ 314
W 1613-19ad 0049 sy 1.42 259 _ 0 0 0 0 0 0 0 0
Blk viell,stucco ext 0.201 sv 5.83 -4.06 -p -- r 0 - -`-0 --0 - 0 -_O---._ _ O _._6
2A 2ov 0.330 sw 957 1551 0 0 0 0 0 0 0 0
��---_-.--GG_ 2A-2ov 0,330 _sw 957 1652 0 0 0 0 0 0 0 0
...__0091 nw 2.64 -_ 221 0_ 0 0_ _..__ 0 0 0. ..-_ 0 0
213-2fv 0.330 nw 957 2622 0 0 0 0 0 0 0 0
2B-2fv 0.330 nw 957 22.09 0 0 0 0 0 0 0 0
11,10 _.. 0.600 ._n.w. -.. 17.4Q 1758 0 _0._...._._...0:._.. --_0 .._.._.... .0 __ -.._.,.0._ .,. _. 0 _ . _..., 0
W. ... 16B 19.ad__ _.__ -.__0049 .nw- - IA2,-,._ .-_259 0 _0 .__0 __ 0 .:.._...._ 0 0 -Lb
Blk mall,stucco ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 6 0
2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
2A-2ov 0.330 nw 957 16.61 0 0 0 0 0 0 0 0
2B-2iv_.. _._ _-_..0.330 ._ - _ .9.57 __ 22.09 --,_...0.
-__0 ..._ ___...9 0 0 0 0 0- ._ _.._.__. .
.12C Osw. _.. ._ ..0 091: ---2.64 -1.31- - - -_,0 -0 --0 0 0 -0-- --0 -..0,
.0_ --- 166-30ad ._ _ 0.032 -0.93. 1.69_ -_ 142.- _142 __,_132 _ _240 -___ 76 76 71 __128
F_.---. 22P-1p1 -- - -- 0.989 28.68__ 0
--- - -0.0, 263 _
- •_ ---..0 _.._ ...--76-- - 13 -373 _-_0
6 c)AED excursion -36 -q3
Envelope loss/gain 841 583 1176 707
12 a) Infiltration 197 55 234 66
b) Room ventilation 0 0
0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Applianceslother 0 0
Subtotal(lines6 to 13) 1038 639 1410 772
Less extemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1038 639 1410 772
15 Duct loads 19% 32% 197 207 19% 32% 268 251
Total room load 1235 846 16678
6 1045
Air required(dm) 49 37 66
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
+ wrYghtsoR� 2021-Sep-2709:48:54
�A Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 8
265AGL\Lot33Blk2Walerstore2265AGL-TraneAlt.rLp CaIc=MJ8 Housefaces:NW
i
Job: Lot 33 Block 2 Waterston 22...
s i ht-J®Worksheet
DEL--AIR R g Date: NOVEMBER 3,2010
'°"w-M1CUMMUMNS Entire House
By: DCS
DEL-AIR HEATING AND AIR
CONDITIONING
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665
1 Room name BR 4
2 Exposed wall 27.0 It
3 Room height 8.0 ft heat/cool
4 Room dimensions 1.0 x 170.0 ft
5 Room area 170.0 ftz
Ty I Construction U-value Or HTM Area (ftz) Load Area Load
number (Btuh/t2-19 (BtuhRtz) or perimeter (ft) (Btuh) or perimeter
Heat I Cool Gross N/PS Heat Cool Gross N/PPS Heat Cool =
O
6 Vdl - 12C-Osw -OD91 ne 2.64 22l 0
I- .(...10C v.._.._._..� --- _ __0.550 ne
W _ 166-19ad_----- 0.049 ne 1 ._ _ 259 -_0 -`--_0_---._._0- - 0 -
Ve Blk wall,stucco ext - 020f he- 5.83 4.06 112 .112 653 455
ne_ 1770_.__ 0 _______.0_.�._._0.__.__.__9
12C-Osw 0.091 se 2.64 221 0 0 0 0
1013-v 0550 se 15.95 12.64 0 0 0 0
2A-2ov 0.330 se 9.57 852 0 0 0 0
-
W_._._, __.__ 0.049. se. _ _1,42 ._.._.259-.___--_e0. -..___.-0 ......_ _0 ._.._ _.._0
yl Blk vd),stucco ext 0.201 se 5.83 4.06 104 89 519 361
-__L--_-G M-.2ov ------_.__ 0.330 .-se-- .__ 9.57._._..1651 _15 -----__2 - 1 4 - _-_-_2 ----- -_-_--._ _ _.-_ _._
VLJ 12C-Osw 0.001 s 2.64 221 0 0 0 0
-G_ 2A-2ov _-_ _...0.330- s.___ ...9.57 ._.�.852_._..._W.0 ,_._. .-.--0 __._v 0 -_ .0
W.__. BlkKell,stuccoext___. _--._ 0201 _s _-_583 _ 4.06 - _.0 .._ 0--- _. .__.0
V�! 12'C Osw 0.091 sv 2.64 221 0 0 0 0
�_7- 11J0_ .W_ _ _. ._ ..__.0.600,-sw _ ..17.40._._ _1758 ..._ .._,. D .__ 0 ..__ -_....0 _.. __. 0
W 166-19ad - -._ ._0.049._sw 1.42 .:.. .259 . . d 0 _ ...., 0 - -0
yJ BIk Kell,stucco ext 0201 sw 5 83 4.06 0 0 0 0
2A-20v 0330 sw 957 1551 0 0 0 0
0.330- sw 9.57
12C-Osrr 0.091 nw 2.64 221 0 0 0 0
-G 2B-2fv 0230 nw 957 2622 0 0 0 0
2B-2fv 0330 nw 957 22.09 0 0 0 0
nw _ 17AO 1758 0 0 _ 0 --. - Q
-161E 19ad, - . .---__.. ._ ._ 0049..)W 1.42,__._-259 -._.._::>.:_0
VV��JI Blk wall,stucco ext 0.201 nw 5.83 4.06 0 0 0 0
2A-2ov 0330 nw 957 16.61 0 0 0 0
2A-2ov 0230 nw 957 16.61 0 0 0 0
2B2iv_,,, ,.,__. _ _.0330 nw -,.__9.57 _..---22.09 ..._ _._ 4 .-_..._._.._0 ._... __ .0 _.. -._._0.._._
0 - O - ;0
C__-__F 16Q-30ad- _ -__ _ 0_032 ._0.93 ___ 1.69 _ _170 170 158 2872?A:Q�L.._: ..---- ------ -0,989 ------ 28,68 0_00 __ _170 .-- -'_27 _. _._774
- _0
6 c)AED excursion 50
Envelope loss/gain 2247 1401
12 a) Infiltration 460 129
b) Room ventilation 0 0
13 Internal gains: Occupants@ 230 0 0
Appliances(other 0
Subtotal(lines 6 to 13) 2708 1531
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 2708 1531
15 Duct loads 19% 321/. 514 497
Total room load 3221 2028
Air required(dm) 1 127 90
Calculations approved bV ACCAto meet all requirements of Manual J&h Ed.
-P�F wrigtitsoR^ 2021-Sep-2709.48.54
Right-Sute®Uriversal202121.0.07RSU24004 Page
265AGLtLot33Uk2Waterstore2265AGL_TraneAlt.np CaIc=MJB House faces:NW
Lot 33
DEL-AIR Duct System Summary Job: NOVEM ER 3,2aterstone...
Y �Y Date: NOVEMBER 3,2010
HFORNc•MR CONDMOHQ16 Entire House By: DCS
DEL-AIR HEATING AND AIR CONDITIONING
531 CODISCO WAY,SANFORD,FL32771 Phore:407-333-2665
Project Information
For: ADAMS HOMES
8501 Waterstone Boulevard,Fort Pierce,FL34951
Heating Cooling
External static pressure 0.30 in H2O 0.30 in H2O
Pressure losses 0.06 in H2O 0.06 in H2O
Available static pressure 0.24 in H2O 0.24 in H2O
Supply/return available pressure 0.120/0.120 in H2O 0.120/0.120 in H2O
Lowest friction rate 0.174 in/100ft 0.174 in/100ft
Actual airflow 1160 cfm 1160 cfm
Total effective length(TEL) 138 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk
BATH 2 h 415 16 9 0.329 4.0 Ox 0 VI Fx 3.0 70.0
BATH 3 h 1678 66 45 0.228 5.0 Ox 0 M Fx 20.4 85.0 st1
BR2 h 2620 103 66 0.295 6.0 Ox0 VIFx 11.4 70.0
BR 3 h 1780 70 57 0.234 6.0 Ox 0 VI Fx 17.5 85.0 sti
BR4 h 3221 127 90 0.217 7.0 Ox0 VIFx 25.4 85.0 st1
BRKFST h 1235 49 37 0.231 6.0 Ox0 MR 19.0 85.0 st1
DIN c 2146 70 95 0.300 6.0 Ox 0 VIFx 10.0 70.0
FAM c 4709 169 208 0.226 8.0 Ox 0 VIFx 21.2 85.0 st2
Krr c 1832 7 81 0.322 5.0 Ox 0 MR 4.5 70.0
LIv h 4521 178 151 0.201 8.0 Ox 0 VIFx 34.3 85.0 st2
M BATH h 1403 55 45 0.179 5.0 Ox 0 MR 34.0 100.0 st3
M BR C 4641 192 205 0.174 8.0 ' Ox 0 VIFx 38.3 100.0 st3
UTIL c 1034 24 46 0.328 4.0 Ox 0 VIFx 3.2 70.0
W c c 53 1 2 0.216 4.0 Ox 0 VI Fx 26.0 85.0 st2
WIC 1 h 816 32 18 0.176 4.0 Ox 0 MR 36.1. 100.0 st3
WIC 2 c 74 2 3 0.182 4.0 Ox 0 VI Fx 32.0 100.0 SO
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk
st3 PeakAVF 281 273 0.174 636 9.0 0 x 0 VnIFIX s2
st2 PeakAVF 628 634 0.174 593 14.0 0 x 0 VnlFlx
st1 PeakAVF 311 229 0.217 571 10.0 0 x 0 VinlFlx
wrightsoft, 2021-Sep-27 09:48:56
�_ .-,,..•,m, M.••.w. NgM-Sule@Uriversal202l 2l.O.O7 RSU24004 Page 1
A+CIN ...265AGL1Lot33Blk2Waterstore2265AGL_TraneAll.np Calc=MJ8 Hoisetaces:NW
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (Cfm) (Cfm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk
rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx
i
I,
wrightsoftm 2021-Sep-27 09:48:56
�/
�.�, ..•m.wM1,.•�,w-,..,-,.•, Right-Sute®Uriversa1202121.0.07 RSU24004 Paget
A/'C
...265AGL\Lo13361k2Waterstore2265AG1_TraneAlt.np CaIc=MJB Hoisetaces:NW
5" both duct
to roof cap
w/ standard 70
cfm bath fan
B � uWNFR'c B OROOM U NZ1
DO T.w to s two •A at >0 as ` Kl
lops 1-al zos 5" both duct z4 m p t K\
1n.m ay Cal kc\
B,4 o m:ASI 0� 14.6 lwcd to roof cap Q — M
Itess 0 G w/ standard 70 NN
e O
1OX61w cfm bath fan O
A g - +6• 16.18 tag V CNNo
� �-
5" bath duct C
to roof cap .. 6 M I l6■la ray z
8- 6. Iwcd
w/ standard 7 sR 20 g
cfm bath fan a 10,,10 rag 210
a, 1416 1wc
BEDROOM • 6" _ KIT H N F �" 4-
aG
p 10.6 lwcd 1DX6 6a 1 d a® .
R 9
� 9- 0'c BATH b
10.10 ra '10.1 e�ag0atX 10,6 4w5cd }
4
24.16 r. N
?t Z m
BFOROOM 2
65 ®orov ro r-r
b W Lu
42X42 A/C SLAB
i A 0
BY BLDR MIN T ,_,,,n ex t_d t o951waa Q p m r I I
2" FROM WALL , �' .9 i . we Mnor�.n - am 150
oav,a. 141,6 lwcd
FNTRY
to dryer oc dH I ru xA m I m s. w
w/dryer vent box Z
\\/ ` N O
LL1 F-
3 CAR OARAf.F 5" bath duct O N x
r-o•ao
to roof cop Z W
NOTE TO UNDERCUT
&ELOUST PROVIDE TO ESTRICTEDHABITABLE w/ standard 70 (n U r-- 1 INCH UNDERCUT BELOW ODORS TO HABITABLE ROOMS Q
1 Transfer ducts/grills sired In compliance
cfm bath fan-light O
with Florid re Residential BuOding Code-M7602.4 Q �
EXCEPT] S 11 e1r.
(�n EXCEPTIONS 1-J 0 � � N
f 2; � • J8.13 NI n/SKW 0240V 1P Q f� ZO }
.n owmr•n oan X)°`a°'+"0 ooa pin/form by (n N m
♦�_ i obldr
AREA CALCULATIONS -1 Q F- m I_ Q
S Q
rora uwc(•n un sr. '.
GN2 I
FLOOR PLAN �am�owste,..A—
Rating
s,.,,.,/r.ra on•noxe•••a�•
roru.wr•vau roar s4o:r,
Must have a minimum clearance of 4 inches around the air handler per the State Energy code, All duct has on r=6 insulation value.