Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: DATE FILED: ` (`� ' a� PERMIT# REVISION FEE: RECEIPT# SO 1Yb PLANNING &DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE EREECEIVED]FORT PIERCE,FL 34982.5652 (772)462.1563 4 20APPLICATION FOR BUILDING PERMIT REVISIOty, Pe PROJECT INFORMATION LOCATION/SITE ADDRESS: P4-' aj63 �> >3y DETAILED DESCRIPTION OF PROJECT FILE C®PY REVISIONS: DUE TO EQUIPMENT SHORTAGES,TRADE TO INSTALL TRANE AIR CONDITIONER ILO CARRIER CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC1330146 ST. LUCIE CO CERT. #: 29179 BUSINESS NAME: ADAMS HOMES OF NORTHWEST FLORIDA, INC. QUALIFIERS NAME: WILLIAM BRYAN ADAMS ADDRESS: 3000 GULF BREEZE PARKWAY CITY: GULF BREEZE STATE: FL ZIP: 32563 PHONE(DAYTIME): 772-905-8394 Fes; 772-905-8511 OWNER/BUILDER INFORMATION: NAME: ADAMS HOMES OF NORTHWEST FLORIDA,INC. ADDRESS:3000 GULF BREEZE PARKWAY CITY: GULF BREEZE STATE: FL ZIP: 32563 PHONE (DAYTIME: 772-905-8394 FAX: 772-905-8511 ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC. 9123109 Revised 06130/17 ML.VISIUN LREc �/Fi�2021 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FORBUILDIN_ Florida Department of Business and Professional Regulation - Residential Performance Method P 9 Project Name: Lot 123 Block 5 Waterstone 1820 BGRNE Builder Name: ADAMS HOMES Street: 5354 San Benedetto Place Permit Office: City,State,Zip:_ Fort Pierce,FL,34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL,ST_LUCIE_CO_INTL County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing Na s• 10. , K_me 2120.0 sgft:) Insulation Area Clock-Int Insul,Exterior R=4.1 1850.00 ft' 2. Single family or multiple famil JEDVe "eolf .. Food,Adjacent R=13.0 270.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms. 4 d.N/A R= ft' 5. Is this a worst case? NO 11.Ceiling Types (1900.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1820.00 ft' 6. Conditioned floor area above grade(ft') 1820 b.Knee Wall(Vented) R=19.0 80.00 ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft Z 7. Windows(239.3 sgft.) Description Area S ttt Ret:Main,AH:Main R ft' 6 364 a. U-Factor: Dbl,U=0.33 168.74 ft2FILl . SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 32.38 ft' 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 34.8 SEER:16.00 c. U-Factor: Dbl,U=0.33 20.42 ft' SHGC: SHGC=0.31 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.999 ft. Area Weighted Average SHGC: .0.269. a.Electric Heat Pump 33.0 HSPF:9.00 8. Skylights Area c. U-Factor:(AVG) N/A ft' 15.Hot water systems SHGC(AVG): N/A a. Electric Cap:40 gallons 9. Floor Types (1820.0 sqft.) Insulation Area EF:0.940 a.Slab-On-Grade Edge.lnsulation R=0.0 .1820.00 ft' b. Conservation features b.N/A R= ft' None c.N/A R= ft' 16.Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 63.69 PASS Total Baseline Loads: 65.00 I hereby certify that the plans and specifications covered by Review of the plans and 1t� SrAr this calculation are in c Hance with the FI Ida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: - - this building will be inspected for 01, - . compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance "Florida Statutes. !� with the Florida E Cod (NCO OWNER/AGENT-GENT• i- BUILDING OFFICIAL:. DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with 111403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 �I r FORM Ft405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 123 Block 5 Waterstone 1 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1820 Lot# 123-5 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone #of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5354 San Benedetto PI Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce, Family Type: Detached FL, 34951 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes - Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 33 ft 0 1820 ft2 0.42 0 0.58 ROOF Roof Gable Roof Rad Solar, SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color ' Barr Absor. Tested Tested Insul: -(deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N- CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type . 1 Under Attic(Vented) Main 30 Blown 1820 ft2 0.11 Wood 2 Knee Wall(Vented) Main 19 Batt 80 ft2 0.11 Wood" 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of.4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NW Exterior Concrete Block-Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 2 NE Exterior Concrete Block-Int Insul Main 4.1 20 0 10 0 200.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block-Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 SE Exterior Concrete Block-Int Insul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 Garage Frame-Wood Main 13 27 0 10 0 270.0 ft' 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height, Area Ft In Ft In 1 NE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in None None 2 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 3 NE 2 Vinyl. Low-E Double Yes 0.33 0.31 N 7.1 ft2 9 ft 0 in, O ft 6 in None None 4 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 3 ft 11 in None None 5 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 5 ft 4 in None None 6 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in None None 7 SE 3 -Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in Oft 10 in None None 8 SE. 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 10 ft 6 in 0 ft 6 in None None 9 SE 4 , Vinyl Low-E Double - Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in None None 10 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 ft 6 in Oft 6 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8 ft 1 INFILTRATION # .Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 -HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity' Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:9 33 kBtu/hr 1 sys#1 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC.7th Edition(2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type. Subtype Subtype Efficiency Capacity Air Flow SHR_ Block Ducts 1 Central Unit/ Split Singl SEER:16 34.8 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC# v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr Ma rj Jun X Jul rj Au rj Se Oct Nov Dec Heatin X}Jan H Feb Mar Apr f May Jun Jul AuSeP Oct Nov Dec Ventin ]]Jan Feb HX Mar [X]Apr [ May Jun [ Jul Aug Se [ Oct H Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020).Compliant Software Page 4 of 4 i FORM R405-2020 r ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5354 San Benedetto Place, Fort Pierce, FL, 34951 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1850.00 ft2 b.Frame-Wood,Adjacent R=13.0 270.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1820.00 ft2 6. Conditioned floor area(ft2) 1820 b.Knee Wall(Vented) R=19.0 80.00 ft2 7. Windows" Description Area c.N/A R= ft2 a. U Factor: Dbl,U=0.33 168.74 ft2 12.Ducts,location&insulation level R ft2 a.Sup:Attic, Ret:Main,AH:Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 32.38 ft2 SHGC: SHGC=0.21 13.Cooling systems kBtulhr Efficiency c. U-Factor: Dbl,U=0.33 20.42 ft2 a.Central Unit 34.8 SEER:16.00 SHGC: SHGC=0.31 d. U-Factor: other(see details) 17.78 ft2 14.Heating systems kBtu/hr Efficiency SHGC: other(see details) a.Electric Heat Pump 33.0 HSPF:9.00 Area Weighted Average Overhang Depth: 3.999 ft. Area Weighted Average SHGC: 0.269 8. Skylights Description Area 15.Hot water systems 2 a. Electric Cap:40 gallons a. U-Factor(AVG): N/A ft EF:0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ft2 Credits(Performance method) Pstat b.N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building oEsr Construction through the above energy saving features which will be installed (or exceeded) 0� CC Apo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature- Date: Address'of New Home: City/FL Zip: ; CAD WB. *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 RK-EIVEP �FOT�M R405-2020 OCT 14 2021 w v • r i Ll-- ST. Lucie County, Permitting RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Bull e r C servation via the Residential Simulated Pen°or ern v ` h I de. ❑ This checklist ❑ Form R405-2020 report ❑ Input summary checklist that can be used for field verification (usually four pages/may be greater) ❑ Energy Performance Level(EPL)Display Card(one page) ❑ HVAC system sizing and selection based on A CCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -one page) ❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed 2020 Duct Leakage Test Report-Performance Method(usually one page) 9/28/2021 2:12:21 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5354 San Benedetto Place Permit Number: Fort Pierce,FL,34951 MANDATORY REQUIREMENTS -See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law ❑ (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOPE ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. ❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturers instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. ❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake, makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. ❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 5 I� MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system, including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for Section R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where Qn= duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are installed,they shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. ❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TMA,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical ventilation,the air handler shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment. ❑ R403.7.1 Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New.or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU (CFM) (CFM/WATT) (CFM) HRV or ERV Any 1.2 cfm/watt Any Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. Fi R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity.on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50oF(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 407(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5 QR403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall beequipped with a va or-retardant cover on or at P PP the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. ❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. R403.13 Dehumidifiers(Mandatory If installed,a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential. R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: Lot 123 Block 5 Waterstone 1820 BGRNE Builder Name: ADAMS HOMES Street: 5354 San Benedetto Place Permit Office: City,State,Zip: Fort Pierce,FL,34951 Permit Number: Y Owner: Jurisdiction: 661000 w Design Location: FL,ST_LUCIE_CO_INTL v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit /soffit ai Ceiling/attic y g the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a.In addition,inspection of log walls shall be in accordance with the provisions of[CC-400. 9/28/2021 2:12 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, 9Y Ener Conservation 7th Edition Jurisdiction: 661000 - Permit#: J0 :information . Builder: ADAMS HOMES Community: Lot: NA Address: 5354 San Benedetto Place City: Fort Pierce State: FL Zip: 34951 . 141P LelkBge Test Results Passing results must meet either-the P•erformancb.Prescriptive,or ERI Method PRESCRIPTIVE,METHOD TI16 building or dwelling'unit shall be tested and verified as having an air leakage.rate of not exceeding 7 air: changes per hour at a pressure"of 0.2 inch w.g,'.(50 Pascals)in Climate Zones 1 and 2: O PERFORMANCE or ERI METHOD=The building,or dwelling unit shall be tested andwerified as having an air leakage rate 'f<not:exceeding r, the.selected ACH(50)'value;as showmon Form R405<,2020'(Performance);or R406-2020(ERI),section labeled as infiltration,sub-section ACH50i' AC14(50)specified,on Form R405-2020-Energy.Calc,(Peiformance)or R406 2020.(ERI):- 7.000 x 60 _ 18200 — Method for calculating buildinq volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans PASS is Code software calculated ❑When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 9/28/2021 2:12:40 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1 ! DEL:AIR Manual S Compliance Report Job: Lot 123 Block 5 Waterson... Date: xUMG•M coN11MOR»c Entire House By: DCS DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM Project • • For: ADAMS HOMES 5354 San Benedetto Place,Fort Pierce,FL 34951 Cooling Equipment Design Conditions Outdoor design OR 90.4OF Sensible gain: 27005 Btuh Entering coil DB: 76.4°F Outdoor designWB: 77.4°F Latent gain: 4767 Btuh Entering coilWB: 63.2°F Indoor design DB`. 75.0 OF Total gain: 31772 Btuh Indoor RH: 50% Estimated airflow: 1160 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Trane Model: 4TWR6036H1+TEM6A0C36H31++TDR Actual airflow: 1160 cfm Sensible capacity: 29024 Btuh 107%of load Latent capacity: 5037 Btuh 106%of load Total capacity: 34060 Btuh 1070/.of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 41.0OF Heatloss: 28570 Btuh Entering coil DB: 69.5`F Indoor design DB: 70.0 OF Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Trane Model: 4TWR6036H1+TEM6A0C36H31++TDR Actual airflow: 1160 cfm Output capacity: 29510 Btuh 103%of load Capacity balance: 37 OF Supplemental heat required: 0 Btuh Economic balance: .-99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1160 cfm Output capacity: 7.6 kW 91%of load Temp.rise: 20 OF. Meets all requirements ofACCA Manual S. wrightsoftm 2021-Sep-2814:10:18 Right-SLite@Uriversal202l 2l.O.O7 RSU24004 Page 1 RNE1Lot123BIk5Waterstone1820BGRNE_TrareAltnQ Calc=MJ8 Frort Door fams:NE L Job: Lot 123 Block 5 Waterson... 4.,AKDEL-AIR Component Constructions Date: NFAi1N8•Ala CONDRrONING Entire House By: DCS DEL AIR HTG,A/C& REFRIG. INC 531CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM Project • • For: ADAMS HOMES 5354 San Benedetto Place,Fort Pierce,FL 34951 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(OF) 70 75 Elevation: 26 ft Design TD(OF) 29 15 Latitude: 28 ON Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 2.4 56.9 Dry bulb(OF) 41 90 Infiltration: Daily range(OF) - 15 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft"F ftz°F/Btuh Btuh/ft� Btuh BtuhV Btuh Walls 16B-19ad:Knee wall,asphalt shingles roof mat,r-19 kw ins,1/2"gypsum ne 20 0.049 19.0 1.42 28 2.59 52 board int fnsh se 20 0.049 19.0 1.42 28 2.59 52 sw 20 0.049 19.0 1.42 28 2.59 52 nw 20 0.049 19.0 1.42 28 2.59 52 all 80 0.049 19.0 1.42 114 2.59 207 Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board int fnsh ne 127 0.201 4.1 5.83 737 4.06 514 se 611 0.201 4.1 5.83 3561 4.06 2481 sw 317 0.201 4.1 5.83 1846 4.06 1286 nw 534 0.201 4.1 5.83 3113 4.06 2168 all 1588 0.201 4.1 5.83 9258 4.06 6449 Partitions 12C-Osw:Frm wall,1/2"gyp.bd ext,r-13 cav ins,1/2"gypsum board int 270 0.091 13.0 2.64 713 1.31 354 fnsh,Z"4'wood frm,16"o.c.stud Windows 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" ne 16 0.330 0 9.57 156 16.6 271 thk;NFRC rated(SHGC=0.21);50%drapes,medium;1 It overhang(5.3 ft window ht,3.9 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl fan mat,clr innr,1/4"gap,1/8" ne 16 0.330 0 9.57 156 16.6 271 thk;NFRC rated(SHGC=0.21);50%drapes,medium;1 ft overhang(5.3 ft window ht,5.3 ft sep.);6.67 ft head ht 2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap, 1/8" ne 7 0.330 0 9.57 67 26.3 184 thk;NFRC rated(SHGC=0.31);9 ft overhang(1.4 ft window ht,0.5 ft sep:);6.67 ft head ht 213-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr, 1/4"gap,1/8" ne 13 0.330 0 9.57 128 22.1 296 thk;NFRC rated(SHGC=0.31);50%drapes,medium;9 ft overhang(6.7 ft window ht,2 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" se 49 0.330 0 9.57 469 15.6 763 thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 ft overhang sw 33 0.330 0 9.57 313 15.6 509 (5.3 ft window ht,0.8 ft sep.);6.67 ft head ht nw 49 0.330 0 9.57 469 17.7 868 all 131 0.330 0 9.57 1251 16.4 2140 t wrightsOft- 2021-Sep-28 14:10:18 •�•••.• .•;..�.� �� m Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 1 RNE1Lot123Blk5Waterstone1820BGRNE TrareAlt.nip Calc=MJB Front Door faces:NE 10C-v:2 glazing,clr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" sw 18 0.550 0 16.0 285 16.2 289 thk;NFRC rated(SHGC=0.70);10.5 ft overhang(6.7 ft window ht,0.5 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" sw 33 0.330 0 9.57 313 8.52 279 thk;NFRC rated(SHGC=0.23);50%drapes,medium;11.5 ft overhang (5.3 ft window ht,0.5 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8" nw 7 0.330 0 9.57 66 17.7 123 thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 ft overhang (3.2 ft window ht,0.8 ft sep.);6.67 ft head ht Doors 11 JO:Door,mtl fbrgl type ne 20 0.600 6.3 17.4 355 17.6 359 Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 1835 0.032 30.0 0.93 1703 1.69 3100 gypsum board int fish Floors 22A-tpl:Bg floor,light dry soil,on grade depth 212 0.989 0 28.7 6080 0 0 wrightsoft, 2021-Sep-28 14:10:18 Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 2 RNE\Lotl23Blk.5Waterslone1B20BGRNE TraneAlLnQ CaIc=MJ8 Frort Door faces:NE II I ' ®EL-AIR Project Summary Job: Lot 123 Block 5 Waterson... xEannc•we coxcmorcxc Entire House By: DCS DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM Proiect Information For: ADAMS HOMES 5354 San Benedetto Place,Fort Pierce,FL 34951 Notes: JA8-18-15 Change to 3.0 ton 2/16/16 S.Finch L.S. 2-5-21 VW K Design Information Weather: St Lude Co Intl,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24350 Btuh Structure 21228 Btuh Ducts 4220 Btuh Ducts 5777 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28570 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 27005 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3364 Btuh Ducts 1403 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1820 1820 Equipment latent load 4767 Btuh Volume(ft3) 18350 18350 Air changeS/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 31772 Btuh Equiv.AVF(cfm) 116 61 Req.total capacity at 0.75 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR6036H1 Cond 4TWR6036H1 AHRI ref 7562981 Coil TEM6AOC36H31++TDR AHRI ref 7562981 Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER Heating Input Sensible cooling 26100 Btuh Heating output 33000 Btuh @ 470F Latent cooling 8700 Btuh Temperature rise 26 OF Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 cfm Airflowfactor 0.041 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.30 in H2O Static pressure 0.30 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=37 OF Backup: Input=8 kW, Output=25920 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -4- wri9htsoft- 2021-Sep-2814:10:18 C �� ^^ Pugtf-Sute®Uriversal 2021 21.0.07 RSU24004 Page 1 RNE\Lot123Blk.5Waterstone1B20BGRNE_TraneAlLrtp Calc=MJB Frort Door faces:NE i DEL-AIR Right-J®Worksheet Job: Lot 123 Block 5 Watersone 18... ruatec-=COMmotanc Entire House Date: By: DCS DEL AIR HTG,A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM 1 Room name Entire House BDRM2 2 Exposed well 212.0 It 36.0 ft 3 Room height 10.0 ft d 10.0 It heat/cool 4 Room dimensions 13.0 x 13.0 It 5 Room area 1835.0 ftz 169.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-`q (Btuh/tz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Ccol Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 W _0.049 -ne _ 1.42. 259 - 20._,___ 20_ _ .28 52 ... _O _0 0 _0 Blk wall,stucco ex 0.201 ne 5.83 4.06 200 127 737 514 0 0 0 0 2A-20v 0.330 ne 957 16.61 16 0 156 271 0 0 0 0 2A-2ov 0.330 ne 957 16.61 16 0 156 271 0 0 0 0 11 2B-2fv 0.330 ne 957 26.32 7 0 67 184 0 0 0 0 2B-2fv 0230 ne 957 22.09 13 0 128 296 0 0 0 0 11J0- _0.600-ne 17.40 -1758 20 ___- 20 .__-,355 _ 359 .049. -se. 1.42 _._259 .20_ 20_--__._ _28_ ,_. .,52 _--_Q __.4 .0 , .__- o V�/ Blk v all,stucco ex 0.201 se 5.83 4.06 660 611 3561 2481 136 136 758 528 L-G 2A-2ov 0.330 se 957 1557 49 13 469 763 0 0 0 0 _168-19ad__ '�___ --_0.049 -sw_ _ 1.42 _259 _ _20 _ -- 20 --28 - 52 __ _-__ 0 _ 0 .0 --. 0 Blk vall,stucco ex 0.201 sw 5.83 4.06 400 317 1846 1286 130 114 663 461 10C-v 0550 sw 15.95 1620 18 18 285 289 0 0 0 0 2A-2ov 0.330 sw 957 1557 33 8 313 509 16 4 156 254 2A-2ov 0,330 sw 957 852 33 33 313 279 0 0 0 0 __. .-_ 0 2_ ._- , _ 0,049 nw _ 1.42 _2S9 ...2O .__. .20 28 _ 52_. .Q_ 0 0 -__0 Blk mall,stuom ex 0.201 nw 5.83 4.06 590 534 31M 2168 100 100 583 4(6 2A-2ov 0.330 nw 957 17.70 7 0 66 123 0 0 0 0 2A-2ov_- ___ 0.330_nw .957,-_ _17.70 _ __49 0 . 469 -- $68 - _0 --0 _ 0 _ _. _0 P_ 12C=0sw-__ _ _0.091 __ 2.64 _ - 1,31 _270 __.__ 270 - -,713 __. 354-__ _ 0 0 0 _ C 16B-30ad 0.032 0.93 1.69 1835 1835 1703 3100 169 169 157 286 F 22A-1pI- -._.._ -- 0.989 _ 28.68 _ _ _ - __.._ .. -0,00 ___ -1835, __212 __ 6080 __ _ 0 _ _169 _ 36_ -1033 _ 0 6 c)AED excursion 821 -1 Envelope losstgain 20646 15143 3349 1934 12 a) Infiltration 3704 1035 691 193 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupantst7a 230 5 1150 0 0 Appliancestother 3900 300 Subtotal(lines 6 to 13) 24350 21228 4040 2427 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 24350 21228 4040 2427 15 Duct loads 17% 27% 4220 5777 17%1 27%1 7001 660 Total room load 28570 27005 4740 3087 Air required(cfm) 1160 1160 192 133 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -i*i+F 2021-Sep-2814:10:18 R Aft, ght-Sute®Udversa12021 21.0.07 RSU24004 Page 1 RNE\Lot123Blk5Waterstone1820BGRNE_TrareAlt.ftp Calc=MJB Frort Door faces:NE DEL--AIR Right-JO Worksheet Job: Lot 123 Block 5 Watersone 18... HUMNO''Mc0'Mrr`Mr Entire House Date: DEL AIR HTG,A/C&REFRIG. INC By DCS 531CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM 1 Room name BATH BDRM3 2 Exposed wall 6.0 ft 13.0 It 3 Room height 10.0 It heattcool 10.0 It heat/cool 4 Room dimensions 13.0 x 6.0 ft 13.0 x 13.0 It 5 Room area 78.0 ft2 169.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (III) Load number (Btuh/ft2-'n (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PrS Heat Cool Gross N/PuS Heat Cool -- --- - - -- - -- -- - - _ --- 6 W _ .16B 19ad.,.� _ - . 0.049 ne.-- .1.9 _-259 y. .-_0 - 0 0 _ 0 _ _- 0 ^0 __.0 Blk vmll,stucco ext 0.201 ne 5.83 4.06 0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 957 16.61 0 0 0 0 0 0 0 0 2A-20v 0.330 ne 957 16.61 0 0 0 0 0 0 0 0 11 26-2fv 0.330 ne 957 2632 0 0 0 0 0 0 0 0 2B-2fv 0330 ne 957 22.09 0 0 0 0 0 0 0 0 -- --- 11J0,-_-.-_.._-_._..__ -__ _0600 _ne_ 17.40. 1758 -- --0---- 0._---_-_. 0 ---_0 -0 -----,r-0 -- 0 -- 0 -16li 19ad_�,-___----_0.049_ se -_-1..0' _259-__..,..-.0__.____ _._.�._0_---.4__0 ..,______ 0 _-- ---19 0 ....__-_-._0 VI/ Blk vv,sll,stucm ext 0.201 se 5B3 4.06 60 60 350 244 130 114 663 461 --G 2A-2ov 0,330 se 9.57 1557 0 0 0 0 16 4 156 254 _ -_ 0.049 _sw- ._ __1.42, „259.-__ 0 0-- _0 BIk-all,stucco ext 0.201 sw 5. 0 0 0 0 0 0 0 0 10C-v 0550 sw 15.95 95 1620620 0 0 0 0 0 0 0 0 2A-2ov 0230 sw 957 15.57 0 0 0 0 0 0 0 0 2A-2ov 0230 sw 957 852 0 0 0 0 0 0 0 0 W_ 16B 19ad ._ --- _ _ _0.049 nw_ 1.42. _259 _ __0 .__-__-0 .. 0__ _-__-0_ __0 ... _ __0 0 0 y! Blk vvdll stucoo ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 -0 2A 2ov 0330 nw 957 17.70 0 0 0 0 0 0 0 0 2A-2ov 0.330 nw 957 .._ _17.70 _ _0 _ ._ _ 0 0 0 _._ 0 . .__ 0 0_.- -0 P.._. 12C-0sw._- - 0.091 __ _2;64 0-----0 C 166-30ad 0.032 - 0.93 1.69 78 78 72 132 169 169 157 286 22A-F- -- WL - -- 0989_ __ 28.68. ._.,_000--------78 .. - -6 -- 172. - _0 169 _ 13 . _._373 6 c)AED excursion -21 66 Envelopeloss/gain 5941 355 1349 1068 12 a) Infiltration 115 32 249 70 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoesbther 0 300 Subtotal(lines6 to 13) 709 387 1598 1437 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 0 0 14 Subtotal 709 387 1598 1437 151 uct loads 17% 27% 123 105 17% 27/ 277 391 Total room load 832 492 1875 1828 Air required(dm) 34 21 76 79 _ Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -R�F wrigF�tsoft- 2021-Sep-2814:10:18 AMA Right-Sule®Uriversal 2021 21.0.07 RSU24004 Page 2 RNE\Lotl23Blk5Waterstorre1820BGRNE_TraneAltnp CaIc=MJ8 Frort Door faces:NE - , DEL--AIR Right-J®Worksheet Job: Lot 123 Block 5 Watersone 18... MUM -=coimmurma Entire House Date: DEL AIR HTG,A/C&REFRIG. INC By: DCS 531 CODISCO WAY SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name DININCvMYER DENBDRM4 2 E)posed wall 25.0 ft 31.0 It 3 Room height 10.0 It heat/cool 10.0 ft heaUcool 4 Room dimensions 1.0 x 276.0 ft 13.0 x 13.0 ft 5 Room area 276.0 ftz 169.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (it) Load number (Btuh/It-fl (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/s Heat Cool Gross N/P/S Heat Cool 6 0.049 ne_ 1.42 259 _----- 0-- --0 --.3 0 Blk well,stucco e# 0.201 ne 5,83 4.06 70 29 170 119 130 97 567 395 2A-2ov 0330 ne 957 16.61 0 0 0 0 16 0 156 271 2A-2ov 0.330 ne 957 16BI 0 0 0 0 16 0 156 271 11 2B-2fv 0230 ne 957 2622 7 0 67 184 0 0 0 0 26-2N 0230 ne 957 22.09 13 0 128 296 0 0 0 0 1110- 0,600 ne-„ 17.40_ 1758 20 355 359 __._ 0 0 0 0 _ _ _ . - UZ/ Blk wall,stucco e# 0.201 se 5.83 4.06 110 77 451 314 130 130 758 528 -G 2A-2ov _ 0.330 se 957 1557 33 8 313 509 0 0 0 0 16&19ad _-- -,______0.049 sw_ 1.42 _ 259. _----0 ,.-----0_ _ 0 0 _._. _. _0_. _ 0 Blk val,stucco e# 0.201 sw 5.83 4.06 0 0 0 0 0 0 0 0 10C-v 0550 sw 15.95 1620 0 0 0 0 0 0 0 0 2A-2ov 0.330 sw 957 1557 0 0 0 0 0 0 0 0 2A-2ov _ 0330 sw 9.57 852 0 0 0 0 0 0 0 0 0049 nw_ 1.42. 259 __. _0= 0 .-__.--_._0 ----- - . _ .- 0 -----0_- 0 -_ -- __0 y/ Blk Snell,stucco e# 0.201 nw 5.83 4.06 0 0 0 0 50 50 291 263 LG 2A-2ov 0230 nw 9.57 17.70 0 0 0 0 0 0 0 0 --,- 2A-2ov _,_----------0 330 nw _ _957- _ 17.70_--- __0. --_ -_-0_.._____0 _-0 --_ _0 _ P -__ _ 12C=0sw---___ ----.. .-0.091 __:__----Z64-_,_131. --_ 70----70 -._- 185-_-__- -_92_-_ --_0- _._ C 16B-30ad 0.032 0.93 1.69 276_ 276 256 466 169 169 - 157 - . 286 _28.68 ___0.00-----276 _25--- --717 --889 ---- 6 c)AED excursion 33 _5 Envelopeloss/gain 2642 2371 2975 1949 12 a) Infiltration 345 97 595 166 b) Room ventilation 0 0 0 0 13 Internal gains Occupants@a 230 1 230 0 0 Appliancesbther 0 300 Subtotal(lines 6 to 13) 2987 2698 3570 2416 Less a#emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2987 2698 3570 2416 15 Dud loads 17% 279/61 518 734 17% 27% 619 657 Total room load 3505 3432 4189 3073 Air required(cfm) 142 147 170 132 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 4- wrightsoft- 2021-Sep-28 14:10:18 Right-Sule®Uriversal 2021 21.0.07 RSU24004 Page 3 RNE'Lot123Blk5Waterstone1820BGRNE TraneAlt.np Calc=MJ8 Frort Door faces:NE DEL--AIR Right-M Worksheet Job: Lot 123 Block 5 Watersone 18... W AMCOKUMOMr Entire House Date: DEL AIR HTG,A/C&REFRIG. INC By: DCS 531CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM 1 Room name FAMILY RM NISTR BDRM 2 Exposed wall 13.0 It 41.0 It 3 Room height 10.0 It heaUmol 10.0 8 heat/cool 4 Room dimensions 13.0 x 22.0 ft 14.0 x 17.0 It 5 Room area 286.0 ft2 238.0 ftz Ty Const uclion U-value Or HTM Area (ft2) Area (ft2) Load . number (Btuhfit-`F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat - Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .__Q.049 .ne 1;42._. 259 20 ._ _.._ 20 28- _52 .,w_. 0 --------0 Blk Hell,stucco ext 0.201 ne 5B3 4.06 0 0 0 0 0 0 0 0 2A-2ov 0,330 ne 957 16.61 0 0 0 0 0 0 0 0 2A-2ov 0230 ne 957 16.61 0 0 0 0 0 0 0 0 11 2B-2fv 0.330 ne 957 2632 0 0 0 0 0 0 0 0 2&2fv 0.330 ne 957 22.09 0 0 0 0 0 0 0 0 11JO -- _ -_0.600 -ne 1740 -_1758 0 0 0 .__-- 0 ,.- _ 0--- _0_ _ _ 0 0 ..16&19ad _. _ 0.049_se _ 1,42,--259_ _,20 _-___20 _.__.u.28 __ _52--_.'__.' ._ 0_ _..___Q ___-0. Blk Hall,stucco ext 0.201 se 5.83 4.06 0 0 0 0 100 100 583 406 2A-2ov 0330 se 9.57 1557 0 0 0 0 0 0 0 0 W ---- 16&19ad--- --- - 0.049_sw_ 1.42____259 - ----20 -_. _20_-,-_-,28_---- 52-- -0 . _0 ----0 - --Q Blk Hell,stuccD eA 0.201 sw 5.83 4.06 130 79 463 323 140 124 721 502 10C-v 0550 sw 15.95 1620 18 18 285 289 0 0 0 0 2A-2ov 0330 sw 957 1557 0 0 0 0 16 4 156 254 2A-2ov 0230 sw 957 852 33 33 313 279 0 0 0 0 _..- _ __.-- - _--.----- ----- �. _ -__ - _ - 16B-19ad 0,049_nw_ 1,42 '4-.0-6 - -__-20 _20_ w28.. 52._..._ _0 .__ _0 __ 0 0. VI! Blk Hall,stucco eM 0.201 nw 5.83 4.06 0 0 0 0 170 154 896 624 2A 2ov 0230 nw 957 17.70 0 0 0 0 0 0 0 0 - 2A-2oy-. - - 0.330_nw _957 17.70 - 0- -- -0 ---0 " -0 -. __16_ .. 0 - -156 289 P- - -12GOsw_----.------- _ -_-0.091 _._ _.2.64 131. --- ---- -0 - --- -- --0 -- -9 - ----0 -- ,0 0. C 1613-30ad 0.032 0.98 1.69 286 286 265 483 238 238 221 402 F 22A-pI -- - -- _0989 _. 28.68 - -0'00 - _._286 -- - 13 _373 - 0 -238 _ _41 _1176. 0 6 c)AED excursion 509 97 Envelope losstgain 1813 2090 3909 2575 12 a) Infiltration 403 113 787 220 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 3 690 1 230 Applianoes/other 600 600 Subtotal(lines 6 to 13) 2216 3493 4696 3625 Less eMemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2216 3493 4696 3625 15 Duct loads 17% 27% 384 950 17% 27% 814 986 Total room load 2600 4443 5510 4611 Air required(c1m) 106 191 224 198 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -i"�F wrightsoft- 2021-Sep-2814:10:18 Right-SL&OUriversal202121.0.07RSU24004 Page RNEtLot123Blk5Waterstone18208GRNE TraneAlLnQ Calc=MJB Front Door faces:NE DEL--AIR Right-JO Worksheet Job: Lot 123 Block 5 Watersone 18... KFA„NG-AIRCUNDMO NG Entire House Date: DEL AIR HTG,A/C&REFRIG. INC By: DCS 531CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM 1 Room name R BATH M WIC 2 Exposed wall 12.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 It heaticool 4 Room dimensions 1.0 x 119.0 ft 7.0 x 7.0 ft 5 Room area 119.0 ftz 49.0 ftz Ty Conshuction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh4tz-fl (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PiS Heat Cool 6 W.._ 16B 19ad-a_ ._ - 0.049 _ne- _ _1.42 __259 -- ._. _. 0 ._ 9 _ _. 0 r_0 -_ ..._-0 Blk wall,stucco eM 0.201 ne 5.63 4.06 -0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 957 16.61 0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 957 16.61 0 0 0 0 0 0 0 0 11 2B-2fv 0.330 ne 957 26.32 0 0 0 0 0 0 0 0 2B-2fv 0.330 ne 957 22.09 0 0 0 0 0 0 0 0 __-_- 11J0_-- 0.600 -ne 17.401758 _ --- _Q .-- 0 .__. _ .0 0 0. . 0_ _ 0 _Q W 16619ad _.,. --_--.-__ __,..0,049 ._SE -1-42..-y._259___. -.Q_�_- __0 ____._„___9 __- - 0 _0_ .__.Q___ .__ 0 Blk vjell,stucco ext 0.201 se 5.83 4.06 0 - 0 0 0 0 0 0 0 tG 2A-2ov 0230 se 9.57 15.57 0 0 0 0 0 0 0 0 _w.__._ 16&19ad- --- _- -0.049 _sw, 1.42. - 259 0- -- -0 ------0 -- __ _.0_ _._ .0 0 0- __.._a 1-=G Blk Hell,stucco ext 0.201 sw 5.83 4.06 0 0 0 0 0 _ 0 0 0 10C-v 0550 sw 15.95 1620 0 0 0 0 0 0 0 0 2A-2ov 0,330 sw 957 1557 0 0 0 0 0 0 0 0 2A-2ov 0,330 sw 957 852 0 0 0 0 0 0 0 0 W_ ._ 16B-19ad__ ._ -_ ___ _.0.049 nw 1.A2 259 _ 6 _ _ - ___0 .0 0 ___.. .0 __. 0 0 0 VlJ BIk well,stucoo eM 0.201 nw 5.83 4.06 120 113 659 459 0 0 - 0 0 I�GG 2A-2ov 0230 nw 957 17.70 7 0 66 123 0 0 0 0 _,. _ - 2A-2ov__ _ ._ 0.330 nw 957 . 17.70 __ __0 _ _ 0 P- - 12C-0snr. - _.0 _ 0 .._ _ _0 _ .. ., _._0 -0 --09 = _2.64__ -_1 31 ._. _..__0_.. --0 - 0 _ - - 0 - 0 - -- 0 0. C _16B-30ad 0.032 0.93 1.69 119 119 110 201 49 49 45 - 83 0.989 = 28,68__-- 0.00 _. 119__ = 12 - --_.344 ._ P _.. . . 49 -- --0 -_ 0 6 c)AED exalrsion 26 -4 Envelope losstgain 1180 809 45 79 12 a) Infiltration 230 64 0 0 b) Room ventilaton 0 0 0 0 13 Internal gains: Oa upantsQa 230 0 0 0 0 Applianoesbther 10 0 Subtotal(lines 6 to 13) 1410 873 45 79 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 115 Subtotal 1410 873 45 79 Ductloads 17% 27°/ 244 238 17% 27% 8 21 Total room load 1655 1111 53 100 Air required(c1m) 67 48 2 4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -14- 2021-Sep-2814:10:18 Right-Suite®Uriversal 2021 21.0.07 RSU24004 Page 5 RNE\Lot123Blk5Waterstone1B20BGRNE_TraneAlt.np Calc=MJB Front Door faces:NE it s DEL--AIR Right-J®Worksheet Job: Lot 123 Block 5 Watersone 18... H=HQ-AMCO °MMr Entire House Date: DEL AIR-HTG,A/C&REFRIG. INC By: DCS 531 CODISCO WAY SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name KrrCHENMOOK LAUNDRY 2 Exposed wall 29.0 ft 6.0 It 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 246.0 ft 6.0 x 6.0 ft 5 Room area 246.0 ft2 36.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/t2-fl (BtuMfl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/Pi5 'Heat Cool Gross N/P/S Heat Cool 6 .W 16&19ad_.....__,.., _ 0,049_ne._____.1.42._._._259 _.- __._"�0 _�-._..�0 �_•:.__._0 _ _: _�_.�:..,___0_ ____ ._0.,_ _�-__�_. ._...:�.0. Blk well,stucco ext 0.201 ne 523 4.06 0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 957 16.61 0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 9,57 16.61 0 0 0 0 0 0 0 0 11 2B-2fv 0.330 ne 957 2622 0 0 0 0 0 0 0 0 2B-2fv 0.330 ne 9,57 22.09 0 0 0 0 '. 0 0 0 0 11JQ __. 0.600_ne_ 17.40 1758, .0 _0 «_ . 0 40 _0 0 _16B-19,d Val Blk wall,stucco ext 0.201 se 5.83 4.06 0 0 0 0 0 0 0 0 I� 2A-2ov 0.330 se 9.57 1557 _0 0_s 0 0 0 0 0 0 _ _ _._ - _ .. W 16B:19ad .. , w.v. _ _0.049 ^sw_- --1.42...____259_._.--_,<0 ;:,��.0 _ . 0 --0 .. _._0.__..._.._0. -. 0 ___ __-0 1-=--G Blk well,stucco ext 0.201 sw 5B3 4.06 0 0 0 0 0 0 0 0 10C-v 0550 sw 15.95 1620 0 0 0 0 0 0 0 0 2A-2ov 0230 sw 9.57 1557 0 0 0 0 0 0 0 0 2A-2ov 0.330 sw 9.57 8.52 0 0 0 0 0 0 0 0 W_. 16B 19ad_'_ _ 0.049 nw _ 142 259____ 0.._W_ ___ __.__ _0_ T___0__. _ _.0 ..r .0 w._.0 _.... 0 Blk well,stucco ext 0.201 nw 5.83 4.06 150 117 684 476 0 0 0 0 2A-2ov 0230 nw 9.57 17.70 0 0 0 0 0 0 0 0 2A 2ovµ_a_ __ _0M0 nw __ ,957 170 33 _0_ _313 __ 579 _0 _ 0 _0 0 P 12Q0sw_--­a-- _0;091 _ _ 2.64 .� 131.r140 -1.40_:- _.369 _-__. _183---j0� 80 __158 C 1613-30ad 0.032 0.93 1.69 246 246 228 416 36 36 33 61 _28_68 _ 0 00 w_246 . �__.29.__. 832_., _ _0 _�.36_- 6 172 6 c)AED excursion 159 -38 Envelope losstgain, 2426 1813 364 102 12 a) Infiltration 288 80 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: OocupantsQa 230 0 0 0 0 Appliancesrother 1200 600 Subtotal(lines6 to 13), 2714 3093 364 702 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2714 3093 364 702 1151 Ductloads 17% 27%1 470 842 17% 27% 63 191 Total room load 3184 3935 427 893 Airrequired(clm) 129 169 17 38 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. P�F wrigF�tsoft^ 2021-Sep-2814:10:18 Aft Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 6 RNBLot1238lk5Waterstone18208GRNE_TraneAltrtp Calc=MJS Front Door faces:NE DEL-AIR Duct System Summary Job: Lot123Block5Waterson.. NMMIG•amCONUMONiNG Date: Entire House By: ocs DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM Project • • For: ADAMS HOMES 5354 San Benedetto Place,Fort Pierce,FL 34951 Heating Cooling External static pressure 0.30 in H2O 0.30 in H2O Pressure losses 0.06 in H2O 0.06 in H2O Available static pressure 0.24 in H2O 0.24 in H2O Supply/retumavailable pressure 0.120/0.120 in H2O 0.120/0.120 in H2O Lowest friction rate 0.212 in/100ft 0.212 in/100ft Actual airflow 1160 cfm 1160 cfm Total effective length(TEL) 113 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mat Ln(ft) Ln(ft) Trunk BATH 2 h 832 34 21 0.278 4.0 Ox 0 VI Fx 16.3 70.0 BDRM2 h 4740 192 133 0.258 8.0 Ox0 VIFx 22.9 70.0 BDRM 3 c 1828 76 79 0.305 6.0 Ox 0 VIFx 8.6 70.0 DENSDRM4 h 4189 170 132 0.288 7.0 Ox0 VIFx 13.2 70.0 DININGTOYER c 3432 142 147 0.314 7.0 Ox 0 VIFx 6.5 70.0 FAMILYRM c 4443 106 191 0.233 8.0 Ox 0 VIFx 17.9 85.0 st1 KrrCHENMOOK c 3935 129 169 0.228 8.0 Ox 0 VIFx 20.1 85.0 sti LAUNDRY c 893 17 38 0.223 4.0 Ox 0 VI Fx 22.7 85.0 st1 M.BATH h 1655 67 48 0.224 5.0 Ox 0 VI Fx 22.2 85.0 st1 M.WIC c 100 2 4 0.225 4.0 Ox 0 VIFx 21.9 85.0 sti MSTR B DRM h 5510 224 198 0.212 8.0 Ox 0 VI Fx 28.2 85.0 sti Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk sti PeakAVF 545 648 0.212 606 14.0 0 x 0 VinlFlx - wrightsofta 2021-Sep-2814:10:19 .u.•kvm xdw- . Rght-Srite®Uriversal 202121.0.07 RSU24004 Page 1 RNEkLot123Blk5Waterstone1820BGRNE_TrareAltnQ Calc=W8 Frort Door faces:NE i i Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rbi Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx -�- wrightsoft` 2021-Sep-2814:10:19 I&S Right-Sule®Uriversal202121.0.07RSU24004 Page ACCK RNE\Lotl23Blk5Waterstore1820BGRNE_TraneAlLrLp Calc=MJB Frort Door faces:NE �I [L5pe9 [OKpp U BEDROOM 42 rua ucl mr vuarm eaurP �' 135 v / 0 5" bath duct 4.8 w 2.1 _J c aG t z z Is., to roof cap axe lwca _ N w/ standord 70 xns D" �r^i 2°0 ` 0 N cfm bath fan — 15,16 ro9t 11z16 rag A Q to za lw e 1 14 rug EAMILV ROOMB. 5" bath duct V V `n '�6 B. IV— 4• ® to roof cap o 14.81wcd na w/ standard 70 c3 _ 90 x4lwcd ® cfm bath fan g '� 10.10 ag A 8- 1Dx6 lwcd 10,6 twotl 5' 50 b BO 6. 14" v BAIIAc � ceps e r as rx7,sx _ r 24.B fe N m 9 e. Z A ODININGRmOOM �m 74z8 lwcd � 4"dryer duet O IQ 12x6 lwcd 7- 170 A to roof cap N 150 4 w/dryer vent box ;:I.D ooa � ruxrm as `am' LU F 9-.PI1242 rag ,a 9 8 7- 4 w�d em 4 12,12 ra g OYE tl a_ 8 u t: BEDROOM 64 I 42X42 A/C SLAB 12.61wed ,1„•, BY BLDR MIN 135 r cAR GARAGE 2' FROM WALL W 2V-V (n Z -..,aNTTRRc W Q H axe o.e.v.a Ppm �O to V) NL W N U H W/5KW 0240V 1P O Q 1.03 J 3 m Piatfarmeby AREA CALCULATIONS QNbldr Z tCo30TN V NOTE TO BUILDER:MUST PROVIDE UNRESTRICTED roruuw,a(K7 msv. N O CV m 1 INCH UNDERCUT.BELOW DOORS TO HABITABLE ROOMS rpss:r. W •• >_ Do Transfer ducts/grills eimal in compliance maaa um Ws0 se it with Florida Residential Building Code—MI602.4 spoAxza J Z in W �j balanced return air. — ExcEPnONS T—s FLOOR PLAN rou uwapuwar ,peer. Q F Do F'¢ ALL ELEVATIONS m CL J V) 0 0 Rating Must have a minimum clearance of 4 inches around the air handler per the State Energy code. All duct has an r=6 insulation value.