HomeMy WebLinkAboutWS LOT 17 - MANJCalculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Oct-09 06:32:52
Right-Suite® Universal 2019 19.0.12 RSU08398 Page 1
...OJECTS ENERGY\A- MANUAL J\KHOV-EDEN-GOODMAN.rup Calc = MJ8 Front Door faces: W
Job:Project Summary Date:Entire House LINDSTROMBy:
Lindstrom Air Conditioning
3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com
Project Information
KHOVNANIAN HOMESFor:
LOT 17 EDEN MODELNotes:
Design Information
Fort Pierce, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F42 Outside db °F90
Inside db °F70 Inside db °F75
Design TD °F28 Design TD °F15
Daily range M
Relative humidity %50
Moisture difference gr/lb61
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh17412 Structure Btuh15008
Ducts Btuh2809 Ducts Btuh5225
Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0
(none)(none)
Humidification Btuh0 Blower Btuh0
Piping Btuh0
Equipment load Btuh20221 Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load Btuh20233
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average
0Fireplaces Structure Btuh2980
Ducts Btuh1547
Central vent (0 cfm) Btuh0
CoolingHeating (none)
16161616Area (ft²)Equipment latent load Btuh4527
1422114221Volume (ft³)
Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh24760
Equiv. AVF (cfm) 4790 Req. total capacity at 0.79 SHR ton2.1
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade Trade
Model 7.5 KW Cond GSX16S301
AHRI ref Coil ASPT37C14
AHRI ref 201785798
Efficiency 100 EFF Efficiency 16 SEER
Heating input kW7.2 Sensible cooling Btuh22000
Heating output Btuh24400 Latent cooling Btuh6000
Temperature rise °F22 Total cooling Btuh28000
Actual air flow cfm1000 Actual air flow cfm1000
Air flow factor cfm/Btuh0.049 Air flow factor cfm/Btuh0.049
Static pressure in H2O0 Static pressure in H2O0
Space thermostat Load sensible heat ratio 0.82
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Oct-09 06:32:52
Right-Suite® Universal 2019 19.0.12 RSU08398 Page 1
...OJECTS ENERGY\A- MANUAL J\KHOV-EDEN-GOODMAN.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House LINDSTROMBy:
Lindstrom Air Conditioning
3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com
1 Room name Entire House BED 3
2 Exposed wall 188.5 ft 38.0 ft
3 Room height 8.8 ft 8.8 heat/coolft
4 Room dimensions ft15.0x10.9
5 Room area 1616.0 ft²163.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 572 514 2058 1125 122 122 488 267
.GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 16 0 143 224 0 0 0 0
.GG 1D-h2omd1D-h2omd 0.5500.550 nn 15.4015.40 17.4717.47 42 0 647 734 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 333 261 1045 571 0 0 0 0
11 GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 48 0 430 2260 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 14.0214.02 24 48 215 337 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 465 449 1798 982 122 122 488 267
GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 16 32 143 224 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 144 108 432 236 99 83 332 182
GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 16 0 143 753 16 0 143 753
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 20 20 218 207 0 0 0 0
PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 200 181 492 241 0 0 0 0
DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 19 19 207 196 0 0 0 0
CC 16B-30ad16B-30ad 0.0320.032 ww 0.900.90 1.601.60 1616 1616 1448 2586 163 163 146 261
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1616 189 5220 0 163 38 1052 0
6 c) AED excursion 0 303
Envelope loss/gain 14641 10676 2651 2033
12 a) Infiltration 2772 781 628 177
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 5 1150 1 230
Appliances/other 2400 0
Subtotal (lines 6 to 13)17412 15008 3279 2440
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 17412 15008 3279 2440
15 Duct loads 16%35%2809 5225 16%35%529 850
Total room load 20221 20233 3808 3290
Air required (cfm)Air required (cfm)1000 1000 188 163
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Oct-09 06:32:52
Right-Suite® Universal 2019 19.0.12 RSU08398 Page 2
...OJECTS ENERGY\A- MANUAL J\KHOV-EDEN-GOODMAN.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House LINDSTROMBy:
Lindstrom Air Conditioning
3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com
1 Room name HALL BATH FOYER
2 Exposed wall 11.0 ft 25.0 ft
3 Room height 8.8 heat/coolft 8.8 heat/coolft
4 Room dimensions ft7.0x11.0 ft21.5x8.0
5 Room area 77.0 ft²172.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 99 99 396 217 0 0 0 0
.GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
.GG 1D-h2omd1D-h2omd 0.5500.550 nn 15.4015.40 17.4717.47 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
11 GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 0 0 0 0 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 45 25 100 55
GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 20 20 218 207
PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 0 0 0 0 20 1 3 1
DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 19 19 207 196
CC 16B-30ad16B-30ad 0.0320.032 ww 0.900.90 1.601.60 77 77 69 123 172 172 154 275
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 77 11 305 0 172 25 692 0
6 c) AED excursion -16 -31
Envelope loss/gain 770 324 1375 703
12 a) Infiltration 181 51 82 23
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)951 375 1457 726
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 951 375 1457 726
15 Duct loads 16%35%153 131 16%35%235 253
Total room load 1105 505 1693 979
Air required (cfm)Air required (cfm)55 25 84 48
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Oct-09 06:32:52
Right-Suite® Universal 2019 19.0.12 RSU08398 Page 3
...OJECTS ENERGY\A- MANUAL J\KHOV-EDEN-GOODMAN.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House LINDSTROMBy:
Lindstrom Air Conditioning
3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com
1 Room name BED 4 LAUNDRY
2 Exposed wall 14.0 ft 0 ft
3 Room height 8.8 heat/coolft 8.8 heat/coolft
4 Room dimensions ft13.5x11.0 ft6.5x8.0
5 Room area 148.5 ft²52.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 126 110 440 241 0 0 0 0
.GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 16 0 143 224 0 0 0 0
.GG 1D-h2omd1D-h2omd 0.5500.550 nn 15.4015.40 17.4717.47 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
11 GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 0 0 0 0 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-30ad16B-30ad 0.0320.032 ww 0.900.90 1.601.60 149 149 133 238 52 52 47 83
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 149 14 388 0 52 0 0 0
6 c) AED excursion -41 -28
Envelope loss/gain 1105 662 47 55
12 a) Infiltration 231 65 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 1 230 0 0
Appliances/other 0 600
Subtotal (lines 6 to 13)1335 957 47 655
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1335 957 47 655
15 Duct loads 16%35%215 333 16%35%8 228
Total room load 1551 1290 54 883
Air required (cfm)Air required (cfm)77 64 3 44
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Oct-09 06:32:52
Right-Suite® Universal 2019 19.0.12 RSU08398 Page 4
...OJECTS ENERGY\A- MANUAL J\KHOV-EDEN-GOODMAN.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House LINDSTROMBy:
Lindstrom Air Conditioning
3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com
1 Room name BED 2 GRT DIN KITCHEN
2 Exposed wall 13.5 ft 49.0 ft
3 Room height 8.8 heat/coolft 8.8 heat/coolft
4 Room dimensions ft11.0x13.5 ft25.0x22.0
5 Room area 148.5 ft²550.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 225 183 733 400
.GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
.GG 1D-h2omd1D-h2omd 0.5500.550 nn 15.4015.40 17.4717.47 0 0 0 0 42 0 647 734
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 216 168 673 368
11 GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 0 0 0 0 24 0 215 1130
GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 14.0214.02 0 0 0 0 24 24 215 337
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 122 106 424 232 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 16 16 143 224 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 0 0 0 0 180 180 489 239
DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-30ad16B-30ad 0.0320.032 ww 0.900.90 1.601.60 149 149 133 238 550 550 493 880
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 149 14 374 0 550 49 1357 0
6 c) AED excursion -17 -251
Envelope loss/gain 1075 677 4821 3837
12 a) Infiltration 223 63 807 228
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 1 230 0 0
Appliances/other 0 1800
Subtotal (lines 6 to 13)1298 970 5628 5864
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1298 970 5628 5864
15 Duct loads 16%35%209 338 16%35%908 2042
Total room load 1507 1308 6536 7906
Air required (cfm)Air required (cfm)75 65 323 391
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Oct-09 06:32:52
Right-Suite® Universal 2019 19.0.12 RSU08398 Page 5
...OJECTS ENERGY\A- MANUAL J\KHOV-EDEN-GOODMAN.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House LINDSTROMBy:
Lindstrom Air Conditioning
3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com
1 Room name MASTER SUITE MAST WIC
2 Exposed wall 26.5 ft 11.5 ft
3 Room height 8.8 heat/coolft 8.8 heat/coolft
4 Room dimensions ft13.0x13.5 ft11.5x5.0
5 Room area 175.5 ft²57.5 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
.GG 1D-h2omd1D-h2omd 0.5500.550 nn 15.4015.40 17.4717.47 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 117 93 372 203 0 0 0 0
11 GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 24 0 215 1130 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 117 117 468 256 104 104 416 228
GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-30ad16B-30ad 0.0320.032 ww 0.900.90 1.601.60 176 176 157 281 58 58 52 92
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 176 27 734 0 58 12 318 0
6 c) AED excursion 101 -15
Envelope loss/gain 1947 1971 786 304
12 a) Infiltration 428 121 190 54
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 2 460 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)2375 2552 977 358
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 2375 2552 977 358
15 Duct loads 16%35%383 889 16%35%158 125
Total room load 2759 3440 1134 483
Air required (cfm)Air required (cfm)136 170 56 24
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Oct-09 06:32:52
Right-Suite® Universal 2019 19.0.12 RSU08398 Page 6
...OJECTS ENERGY\A- MANUAL J\KHOV-EDEN-GOODMAN.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet Date:Entire House LINDSTROMBy:
Lindstrom Air Conditioning
3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com
1 Room name M BATH
2 Exposed wall 0 ft
3 Room height 8.8 heat/coolft
4 Room dimensions ft12.0x6.0
5 Room area 72.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area Load
number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0
.G 1D-h2om 0.320 n 8.96 14.02 0 0 0 0
.G 1D-h2omd 0.550 n 15.40 17.47 0 0 0 0
.W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0
11 G 1D-h2om 0.320 e 8.96 47.08 0 0 0 0
G 1D-h2om 0.320 e 8.96 14.02 0 0 0 0
W 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0
G 1D-h2om 0.320 s 8.96 14.02 0 0 0 0
W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0
G 1D-h2om 0.320 w 8.96 47.08 0 0 0 0
D 11D0 0.390 w 10.92 10.34 0 0 0 0
P 12B-0sw 0.097 -2.72 1.33 0 0 0 0
D 11D0 0.390 s 10.92 10.34 0 0 0 0
C 16B-30ad 0.032 w 0.90 1.60 72 72 65 115
F 22A-tpl 0.989 -27.69 0.00 72 0 0 0
6 c) AED excursion -5
Envelope loss/gain 65 110
12 a) Infiltration 0 0
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal (lines 6 to 13)65 110
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 65 110
15 Duct loads 16%35%10 38
Total room load 75 149
Air required (cfm)4 7