HomeMy WebLinkAboutNOAPalram Americas, Inc.
9735 Commerce Circle
Kutztown, PA 19530
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-
Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve
the right to have this product or material tested for quality assurance purposes. If this product or material
fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ
may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction.
RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Corrugated and Flat Polycarbonate Panels
APPROVAL DOCUMENT: Drawing No. 20-096, titled "Polycarbonate Panels", sheet 1 of 1, dated
08/02/2020, prepared by Engco Inc., signed and sealed by John Pedro M. De Figueiredo, P.E., bearing the
Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration
date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: None
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/ series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA # 18-0328.02 and consists of this page 1 and evidence pages E-1, E-2
and E-3, as well as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
I NOA No. 20-0828.02
MIAMI-DADE COUNTY ?f : ✓' ��
� Expiration Date: January 22, 2026
Approval Date: October 22, 2020
Page I
Palram Americas, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs
A. DRAWINGS "Submitted under NOA # 15-1207.07"
1. Drawing No. KC15-0805, titled "Polycarbonate Panel", sheet 1 of 1, dated 10/19/2015,
prepared by Knezevich Consulting, LLC, signed and sealed by John W. Knezevich, P.E.
B. TESTS "Submitted under NOA # 00-1226.02 & 05-0907.03"
Laboratory Test
Date
Signature
1.
SGS 369159-4 ASTM E 84
08/22/05
J. Lomash
2.
SGS 170558-7 ASTM E 84
09/23/02
G. Banasky
3.
SGS 170558-2 ASTM E 84
09/23/02
G. Banasky
4.
SGS 170558-10 ASTM D 635
09/23/02
G. Banasky
5.
SGS 170558-12 ASTM D 635
09/23/02
G. Banasky
6.
SGS 369159-1 ASTM D 635
08/22/05
J. Lomash
7.
SGS 155380-10 ASTM D 1929
05/29/01
D. Lepore
8.
SGS 528768 ASTM D 1929
02/06/06
J. Lomash
9.
Celotex MTS # 258188A ASTM D 1929
07/28/97
R.G. Miller, P.E.
10.
Celotex MTS # 258188B ASTM D 635
07/28/97
R.G. Miller, P.E.
11.
Celotex MTS # 258188C ASTM E 84
07/18/97
R.G. Miller, P.E.
12.
Celotex MTS # 257933 ASTM D 638 & G26
09/12/97
R.G. Miller, P.E.
C. CALCULATIONS
1.
None.
D. QUALITY ASSURANCE
1.
Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1.
None.
F. STATEMENTS "Submitted under NOA # 15-1207.07"
1. Statement letter of code conformance to the 5' edition (2014) FBC issued by Knezevich
Consulting, LLC, dated 11/30/2015, signed and sealed by John W. Knezevich, P.E.
2. Statement letter of no financial interest issued by Knezevich Consulting, LLC, dated
11/30/2015, signed and sealed by John W. Knezevich, P.E.
3. Standards' equivalency letter issued by Knezevich Consulting, LLC, dated 11/30/2015, signed
and sealed by John W. Knezevich, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0828.02
Expiration Date: January 22, 2026
Approval Date: October 22, 2020
E-1
Palram Americas, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. EVIDENCE SUBMITTED UNDER NOA # 18-0328.02
A. DRAWINGS
1. Drawing No. KC18-0218, titled "Polycarbonate Panel", sheet 1 of 1, dated 10/19/2015,
with revision 0 dated 03/26/2018, prepared by Knezevich Consulting, LLC, signed and
sealed by John W. Knezevich, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 6`s Edition (2017) FBC issued by
Knezevich Consulting, LLC, dated 03/26/2018, signed and sealed by John W.
Knezevich, P.E.
Carlos M. lUtrera, P.E.
Product Control Examiner
NOA No. 20-0828.02
Expiration Date: January 22, 2026
Approval Date: October 22, 2020
E-2
Palram Americas, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
3. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 20-096, titled "Polycarbonate Panels", sheet 1 of 1, dated 08/02/2020,
prepared by Engco Inc., signed and sealed by John Pedro M. De Figueiredo, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Drawing No. 20-096 code conformance statement to the 7 h Edition (2020) of the FBC
issued by Engco Inc., dated 08/02/2020, signed and sealed by John Pedro M. De
Figueiredo, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0828.02
Expiration Date: January 22, 2026
Approval Date: October 22, 2020
E-3
GENERAL NOTES:
1- CODE: FLORIDA BUILDING CODE 2020 - 7TH EDITION - HVHZ.
2- POLYCARBONATE PANELS SHALL BE 0.8 MM (0.031") OR THICKER, SOLID CLEAR PANELS, FLAT OR
CORRUGATED WITH NO SURFACE FINISH
3- THIS PRODUCT EVALUATION DOCUMENT ADDRESSES THE REQUIREMENTS OF THE POLYCARBONATE
PANELS AS AN APPROVED PLASTIC. SPECIFIC USE OF THIS PANEL SHALL COMPLY WITH THE FBC. ANY
EXTERIOR ENVELOPE USE SHALL REQUIRE A NOTICE OF ACCEPTANCE INCA) ADDRESSING THE SPECIFIC
USE.
4- TABLE 1 PROVIDES MATERIAL PROPERTIES AS REQUIRED TO COMPLY WITH CHAPTER 26 OF THE
FLORIDA BUILDING CODE. REFERENCE SPECIFIFC CODE REQUIREMENTS BASED ON THE USE TO
EVALUATE MATERIAL COMPLIANCE.
5- TABLE 2 REFERENCES THE TENSILE TESTING ON CONTROLLED AND WEATHEREEO SPECIMENS PER ASTM
D638. RESULTS ARE WITHIN ±10% IN ACCORDANCE WITH THE FBC SECTION 2615.2.2C AND
M IAM I-DADE CHECKLIST #0445.
6- THE FOLLOWING PRODUCT TRADE NAMES ARE USED TO DESCRIBE THIS MATERIAL:
SUNTUF, SUNSKY, DYNAGLAS, PALTUF AND PALSUN
TABLE 1
TRADENAME
MATERIAL
THICKNESS
FORMAT
TEST
DESIGNATION
TEST PARAMETER
TEST
RESULTS
FLAME SPREAD
SUNTUF/SUNSKY/DYNAGLAS
0.8mm
(0.031")
CORRUGATED
ASTM E84
INDEX
S0
SMOKE DEVELOPED
VALUE
130
FLAMESPREAD
PALTUF/PALSUN
3 mm
(0.118"I
FLAT
ASTM E84
INDEX
60
SMOKE DENSITY
<450
FLAME SPREAD
PALTUF/PALSUN
12 mm
(0.472")
FLAT
ASTM E84
INDEX
45
SMOKE DENSITY
<450
AVERAGE BURNING
TIME
155 SEC
SUNTUF/SUNSKY/DYNAGLAS
0.8mm
(0.031")
CORRUGATED
ASTM D63S
AVER NING
LENGTH BURNING
LENGTH
mm
28.0
BURN RATE
mm//mm in.
AVERAGE BURNING
PALTUF/PALSUN
3mm
(0.118")
FLAT
ASTMD635
TIME
6.4 SEC
AVERAGE BURNING
LENGTH
21.9 mm
AVERAGE BURNING
PALTUF/PALSUN
12 mm
(0.472")
FLAT
ASTM D635
TIME
2.8 SEC
AVERAGE BURNING
LENGTH
10.3 mm
SELF IGNITI ON
SUNTUF/ SUNSKY/ DYNAGLAS/
0.8 mm
TEMPERATURE
1.162°F
PALTUF/PALSUN
(0.0311)
FLAT
ASTM D1929
FLASH IG NITION
TRMPERATURE
9827
TABLE 2 -AVERAGE YIELD TENSILE STRENGTH PER ASTM D-638
PLASTICSPECIMEN
WEATHERING (PSI)
VAR.
BEFORE
AFTER
0.8mm (0.031") CLEAR CORRUGATED
9240
9270
0.3°%
0.8mm (0.031") CLEAR FLAT
9710
8940
7.9%
3.Omm (0.0118") CLEAR FLAT
9660
9090
5.9°%
PALRAM
MANUFACTURER:
PALRAM AMMCAS, INC.
9735 COMMERCE CIRCLE
KUTZTOWN, PA 15530
PHONE: (G 1 0) 285-39 18
PHONE:(800)999-9455
PAX: (G 10)285-2859
WWW. PALRAMAMERICA5.COM
PRODUCT:
"OD'
PANELS
FLAT AND CORRUGATED PANELS
IMPACT RATED
ENGINEERING:
ENGCO INC. CA811G
97 15 W. BROWARD BLVD. 247
PLANTATION, FL 33324
ENGCO@AOL.COM
BE'F
C ENSF
No.52609
` STATE OF
• ?0�`� R 10 `'���P�C•
�'ss�ONAI �•`'���'
S�t7� fngmeer Seat
Pedro De figueireda - PE 52GO9
MIAMI-DADE BCCO:
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 20-0828.02
Expiration Date01/22/2026
By-i.,�..-,..,
Miami -Dade Product Control
DATE: 08/02/2020
SCALE: NA
DESIGN BY: PPMF
SMEET I DRAWING #:
I OF I 20-OOG