Loading...
HomeMy WebLinkAbout2020tiedownT 0 0 N n 0 1,0000 TYP, 0,693B TYP, 0.3063 TYP, 0.3081 O.1i726 TYP. TYP. 11290 TYP, n L1290 I I TYP, 0.7500 TYP. 12500 TYP, 1 4" SOLONG CLIP 1 N.T.S. FLATTENED 1.0000 TYP. 0.6939 TYP, 0.3063 TYP. 1.110,6152 97 TYP, TYP, 1 290 TYP. MIAMI TECH, INC. MECHANICAL UNIT STEEL TIE -DOWN CLIP: AT GRADE &ROOF -TOP MOUNTED APPLICATIONS STEEL TIE -DOWN CLIP 0.0700 TYP. 4,C SIDE VIEW TYP. 0.6939 ALL OTHER CLIPS SIMILAR TYP, VARYING LENGTH ONLY 03063 _ TYP, I 0.0700 J- TYP, 0.7500 0.5000 TYP. TYP. 1.0000 TYP, 0.693E TYP. 0.3063 TYP. 1.3759 0.8114 TYP. TYP, _F T 1.1290 TYP. n I I 1,1290 TYP, 0.7500 0.7500 TYP. TYP. � 1.2500 L.2500 TYP. O TYP. 00.2500 � 2 6" LONG CLIP 1 N.T.S. FLATTENED 0D.2500 � 3 8" LONG CLIP 1 N.T.S. FLATTENED 1.0000 TYP. 0,6937 TYP, 0.3062 TYP. 0.5534 TYP. 1.1179 TYP. 1.1290 TYP. 1.1290 TYP. 1 1 0.7500 TYP. 1.2500 TYP. 00.2500 � 4 10" LONG CLIP 1 N.T.S. FLATTENED 0.0599 TYP. 1.0000 TYP, 1.1290 TYP, 1.1290 TYP, 0.7500 TYP. TYP. L TYP. 00.2500 � 5 12" LONG CLIP 1 N.T.S. FLATTENED DESIGN NOTES: 1. THIS PRODUCT HAS BEEN DESIGNED IN ACCORDANCE WITH ASCE 7-16 AND THE FLORIDA BUILDING CODE SEVENTH EDITION (2020) FOR USE WITHIN AND OUTSIDE THE HIGH yELOCITY HURRICANE ZONE AS INDICATED IN THE ACCOMPANYING DESIGN SCHEDULES. THE DESIGN CRITERIA USED TO CALCULATE THE ALLOWABLE ROOF -TOP HEIGHTS CONSIDERS FBC CHAPTER 16: (GCFLte I=1.90 WITHIN THE HVHZ & OUTSIDE THE HVHZ, (GCF)upl It=1.5 FOR ALL LOCATIONS (CONCURRENT). 2. ALL OTHER DESIGN VARIABLES ARE IN ACCORDANCE WITH ASCE 7 CHAPTERS 26 & 29. 3. THE HEIGHTS LISTED IN THE DESIGN SCHEDULES REPRESENT THE ALLOWABLE HEIGHT OF THE BUILDING. 4. THIS PRODUCT APPROVAL ALLOWS FOR EACH UNIT TO BE INSTALLED ON A MAXIMUM 30" TALL ABC STAND (CERTIFICATION BY OTHERS) ON TOP OF THE HEIGHTS LISTED IN THE DESIGN SCHEDULES. 5. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. 6. DESIGN IS BASED ON CLIENT PROVIDED PRODUCTAND DIE SHEETS FROM TEST REPORT PROJECT #15-6206 BY FENESTRATION TESTING LABORATORY, INC.. NO SUBSTITUTIONS WITHOUT WRITTEN APPROVAL BY THIS ENGINEER SHALL BE PERMITTED. 7. STEEL CLIPS SHALL BE ASTM A653 STEEL WITH Fy=33 KSI OR BETTER. STEEL MEMBERS SHALL BE PROTECTED AGAINST CORROSION WITH AN APPROVED COATOF PAINT, ENAMEL OR OTHER APPROVED PROTECTION. G90-RATED COATING REQUIRED FOR COASTAL INSTALLATIONS. GENERAL NOTES: 1. THIS PRODUCT HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE & ASCE 7. THIS PRODUCT MAY BE USED WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 2. MAXIMUM & MINIMUM DIMENSIONS AND MINIMUM WEIGHT OF MECHANICAL UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 3. FASTENERS TO BE #10 X 3/4" OR GREATER STAINLESS STEEL 410 UNLESS NOTED OTHERWISE. ANCHORS REFERRED TO HEREIN SHALL BE ELCO BRAND, STAINLESS STEEL ONLY, INSTALLED TO 3000 PSI MIN CONCRETE. SEE ANCHOR TO HOST SCHEDULE FOR ANCHOR REQUIREMENTS. ALL FASTENERS SHALL HAVE APPROPRIATE CORROSION PROTECTION TO PREVENT ELECTROLYSIS. 4. ALL CONCRETE SPECIFIED HEREIN IS NOT PART OF THIS CERTIFICATION. AS A MINIMUM, ALL CONCRETE SHALL BE STRUCTURAL CONCRETE 4" MIN. THICK AND SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI, UNLESS NOTED OTHERWISE. 5. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 6. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 7. THE ADEQUACY OF ANY EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS SHALL BE VERIFIED BY THE ONSITE DESIGN PROFESSIONAL AND IS NOT INCLUDED IN THIS CERTIFICATION. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. S. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FORA SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 9. WATER -TIGHTNESS OF EXISTING HOST SUBSTRATE SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THATANY REMOVED ORALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. FOR AN EXPLANATION OF EXPOSURE AND RISK CATEGORIES THAT ACCOMPANYTHE Vult WIND SPEEDS USED IN THIS APPROVAL, SEE ASCE 7. VISIT ECALC.10126324 r FOR SITE SPECIFIC DEVIATIONS & MORE INFORMATION ABOUT THIS DOCUMENT OR SCAN THIS OR CODE VISIT ENGINE ERINGEXPRESS.COMIMIAMITECH FOR ADDITIONAL PLANS, REPORTS & RESOURCES LANK BENNARDO, PE °# 0046549 CA# 9885 ° N O � fm o,u0 Wo-- V1U Z V� LJL wLn ILLL a w O 2 GJjK wW U fox gawoWi� OZ M SLUE iv 0� 0+m•+ZW V N -LJz 3LL�:f� cn w W W En Z O a H > LiLLa z Lua w L--L U m CA It LLn H LL p O N v CL U + Z r1 ^�`'� 3a o 30^ oo°' LW r Z f L1 H .N. J C ,1 0 m Z ILL ~ O L O Q U Lu w ICI 2 U U p, w ^ ~ U m a LL W z-`zz � o H u� `m sa 0 0 0 93 Y m m m Z w�0=� tl IJi lJi I g § Z = �E Z0 < < mw �Y5 0 �rff z o w boo ���w� a>> s4 V U z K K 4 111 O m m ? z o Y w cn ? q z�tr� COPYRIG HT ENG INEERING EXPRESSm 20-26324 Ple-34* 1 n COIV IV ECTI ON TYPE Cl 1"X6" CLIP - UTILIZE (1) AT EACH CORNER FOR A TOTAL OF (4) PER UNIT NOTE: ALSO APPLICABLE FOR CLIP 4" LONG ALTERNATE CLIP LOCATION, SEE PAGE 3 DETAIL 3/3 -v 3" MA �TYP. CLIPS �r 3 MA)(t CONNECTION TYPE C2 1"X6" CLIP - UTILIZE (2) AT EACH CORNER FOR A TOTAL OF (8) PER UNIT NOTE: ALSO APPLICABLE FOR CLIP 4" LONG *NOTE: SEE ANCHOR TO HOST SCHEDULE FOR ALL EDGE DISTANCE TO ANCHOR SPACING LIMITATIONS. SEE PAGE 4. n CONNECTION TYPE C3 1"X12" CLIP - UTILIZE (1) AT EACH CORNER FOR A TOTAL OF (4) PER UNIT NOTE: ALSO APPLICABLE FOR CLIPS 8" & 10" LONG LTERNATE CLIP LOCATION, SEE PAGE 3 DETAIL 3/3 3 a0 CONNECTION TYPE C4 1"X12" CLIP - UTILIZE (2) AT EACH CORNER FOR A TOTAL OF (8) PER UNIT NOTE: ALSO APPLICABLE FOR CLIPS 8" & 10" LONG LANK BENNARDO, PE °# 0046549 CA* 9885 it7'w2p,. kQ N O F W M al u o w1�-1 J U113 V � LL w U) m wW U tax F _z - g < Lu 7 a� m z� zw 074 fW-1 4 @ cn w W ow ,i %o o Ln Z O � a 0 Va z Lua w 1-4 U m Ln HLLn -j O N UrL U _ 1 Z (+1 ^ �''� 3 0 ^ LLLLI�a� r Z f 1 1 og� Lb f�1 Z IL C C U Lu W = Ste' U r, L W ^ ~ U m Q LL f W o Ymmmz a U ILL LJL w�1yF z z 0 +9 rcz °¢ ° m Cf z p w� Wig o o o ;��� m ms�$ 0 COPYRIGHTENGINEERING EXPRESSm 20-26324 SCALE: N.T.S. STEEL TIE -DOWN CLIP PH T 0 0 2 n 0 MAXIMUM UNIT ATTACHMENT TO STAND HEIGHT (SEE DESIGN SCHEDULES)" �t " CLIPS 3" MAX* TYP. 3" MA) TYP. "� 3"x3"xY" OR 3"x5"x3/6" SMALL UNIT ANGLE ATTACHED PER MIAMI TECH STAND NOA, SEE DETAIL A/A FOR ALTERNATE CLIP ATTACHMENT WHEN ANGLE IS NOT USED n CONNECTION TYPE Cl MAXIMUM UNIT HEIGHT (SEE DESIGN SCHEDULES) (1) OR (2) CLIPS PER DETAILS Cl THROUGH C4 AND SHEET 4 UNIT BY OTHERS FASTEN CLIPS TO UNIT AND STAND PER SHEET 4 � MLyM `�pu��51 MYNZ N 5'' 3"x3"x/" OR 3"x5"x3/6" SMALL UNIT ANGLE ATTACHED PER MIAMI TECH STAND NOA, SEE DETAIL A/A FOR ALTERNATE CLIP ATTACHMENT WHEN ANGLE IS NOT USED n CONNECTION TYPE C3 `J 1"X6" CLIP - UTILIZE (1) AT EACH CORNER FOR A TOTAL OF (4) PER UNIT NOTE: ALSO APPLICABLE FOR CLIP 4" LONG MAXIMUM UNIT 3"x3"x%" OR 3 SMALL UN] ATTACHED PER MIS STAND NOA, SEE DE FOR ALTERN, ATTACHMENT WHEN ANGLE IS NOT USED n CONINIECTION TYPE C2 ALTERNATE CLIP TO STAND DETAIL SCALE: N.T.S. 1"X12" CLIP - UTILIZE (1) AT EACH CORNER FOR A TOTAL OF (4) PER UNIT NOTE: ALSO APPLICABLE FOR CLIPS 8" & 10" LONG MAXIMUM UNIT HEIGHT (SEE DESIGN SCHEDULES) *NOTE: SEE ANCHOR TO HOST SCHEDULE FOR ALL EDGE DISTANCE TO ANCHOR SPACING LIMITATIONS. SEE PAGE 4. A 2" CLIPS i i 3" MAX* % TYP. ' 3" Mr A TYP. MYNZ Z�N 5 Nip L�S� Qr 3"x3"x%" OR 3"x5"xfi6.. r SMALL UNIT ANGLE ATTACHED PER MIAMI TECH STAND NOA, SEE DETAIL A/A FOR ALTERNATE CLIP ATTACHMENT WHEN ANGLE IS NOT USED n CONNECTION TYPE C4 STEEL TIE -DOWN CLIP 4NK BENNARDO, PE 0 0046549 CA# 9885 l 7'w2p,. ko N O w M of fn Ql u o � v � LL Lu �ONW U �a Ox gQ W owl9 ozMSLUE +I ON 0 mz W .)74 LU LU z 1-1 4 @ 3 LL U) W Lu ow 1 %o In z J oa H 7 Va Z Lua w �--� U m Ln _j O N � _ 1 Z (+1 3 0 ^ 0rq LWL3ao r f 1 1 Lb.N. J ,1 m z U- C L M Q U Lu w I --I 2 U U w ^ ~ U m a LL f W o Y m m m z 0n0 Z z1yy 0 '9LL z w UI omm z e o=$ i5 0 s W L z � � � COP"RIGHTENGINEERING EXPRESSm 20-26 54 1"X6" CLIP - UTILIZE (2) AT EACH CORNER FOR A TOTAL OF (8) PER UNIT NOTE: ALSO APPLICABLE FOR CLIP 4" LONG 1"X12" CLIP - UTILIZE (2) AT EACH CORNER FOR A TOTAL OF (8) PER UNIT NOTE: ALSO APPLICABLE FOR CLIPS 8" & 10" LONG 01 0.07" THICK ASTM A653 STEEL, TYP. (4)-#10 SS 410 SELF DRILLING SCREWS FOR CLIPS UP TO 6' LONG. UTILIZE (8)-#10 SS 410 SELF DRILLING SCREWS FOR CLIPS LONGER THAN 6", TYP. *FOR ANY CLIP LONGER THAN 6" UTILIZE (8)-#10 SS 410 SELF DRILLING o SCREWS, TYP. Ln o w� �o v /4"0 HOLE, WITH ANCHOR FROM CLIP ANCHOR TO HOST SCHEDULE, TYP. 1" CLIP ISOMETRIC DETAIL N .T.S. F.11 \ Is] mW:4111011mLola IMIQi1:1DIM A:1 SUBSTRATE DESCRIPTION (1)-1/4"0 STAINLESS STEEL 410 DEWALT CONCRETE: ULTRACON, IY4" FULL (4" THICK MIN, EMBED TO CONCRETE, 2/" 3000 PSI MIN.) MIN. EDGE DISTANCE, 3" MIN. SPACING TO ANY ADJACENT ANCHOR. (1)-#14 SAE STAINLESS ALUMINUM: STEEL BOLT 410 WITH NUT (0.125" MIN. AND WASHER TOP & THICK, 6061-T6 BOTTOM SS OD 1", 1/2" MIN. ALUMINUM) MINIMUM EDGE DISTANCE TO METAL EDGE (1)-#14 SAE STAINLESS STEEL: STEEL BOLT 410 WITH NUT (0.125" MIN. AND WASHER TOP & THICK, 50 KSI BOTTOM SS OD 1", X" MIN. STEEL) MINIMUM EDGE DISTANCE TO METAL EDGE ISOMETRIC MECHANICAL UNIT BY OTHERS. ALUMINUM HOUSING UNITS SHALL BE 6063-T6 MIN. ALUMINUM SHEET WITH Fty=30 KSI, 0.125" MIN. THICKNESS, STEEL HOUSING UNITS SHALL BE ASTM A653 Fy=33KSI MIN. STEEL, GRADE 33, 22GA MIN. (t=0.0299"). 1. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 2. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 2 3. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. 4. SEE DETAILS ON SHEET 4 FOR ANCHORS ATTACHING TO MECHANICAL UNIT. 5. PROTECT ALL METALS FROM DISSIMILAR METALS GENERAL NOTE #5 0.07" THICK ASTM A653 STEEL CLIP, TYP. (4)-#10 SS 410 SELF DRILLING SCREWS FOR CLIPS UP TO 6" LONG. UTILIZE (8)-#10 SS 410 SELF DRILLING SCREWS FOR CLIPS LONGER THAN 6". PROVIDE (5) PITCHES MIN. PAST THREAD PLANE FOR EACH SMS, TYP. ANCHOR PER ANCHOR SCHEDULE. SEE DETAIL A -A FOR I THRUBOLT i ATTACHMENT SUBSTRATE PER ANCHOR TO HOST SCHEDULE i (VARIES) 1" TIE -DOWN CLIP ANCHOR DETAIL 4 / 3" = 1'-0" DETAIL �� CLIP IS DESIGNED FOR FULL CONTACT WITH THE BASE OF EACH MECHANICAL UNIT, TYP. LANK BENNARDO, PE °# 0046549 CA* 9885 .IF - kQ N O . w M O z i M 0'pp6o Wby J Ln OIu ui Lu Fj V zw 1 t � < LU O Q3�wz 1 Lu 0. ozd cc ApLu A -A / Lu STEEL OR 0 *� L j Tw z ALUMINUM 3 LL a f iv BOLT PER \ — SUBSTRATE PER Ul W w ANCHOR ANCHOR O w SCHEDULE SCHEDULE cl ►4 ECHANICAL NIT PER PARATE =RTI FI CATION SEE ANCHOR TO HOST SCHEDULE TYP. 3 ALTERNATE 8 CLIP DETAIL 4 N.T.S. PLAN VIEW THIS DETAIL MAY BE USED AS AN ALTERNATE GEOMETRIC PATTERN FOR ALL CONNECTION TYPES THAT UTILIZE (2) CLIPS AT EACH CORNER FOR ATOTAL OF (8) CLIPS PER UNIT. to Z J oa o LL CL Va Z Lua w 1- 4 U m a o N HLLn UCL U _ 1 ^, r� Z (+1 30^ LU ID og� Z f 1 1 1 .N. J "' C G rn Z w O L Q U Lu w U r, w ^ ~ U m Q LL f w H u `m o 't Q w z1yz1y 13 m $; 0 0 0 Ymmmz � � 1202 w�1y U IJi lJi 7SF z 0 +9 w F oz z yzy O w K w U ? LC�f o b 9 Q>> U U s z UI Y 0 w m w ?z o COP"RIGHTENGINEERING EXPRESSm 20-26324 SCALE: N.T.S. OF 0 n 0 STEEL TIE -DOWN CLIP FRANK SENNARDO,PE PE# 0046549 CA# 9885 O 7'w2p, TABLE 1 PERMISSIBLE INSTALLATION HEIGHTS: Vult=175 MPH, EXPOSURE C TABLE 2 PERMISSIBLE INSTALLATION HEIGHTS: Vult=175 MPH, EXPOSURE D (FOR USE WITH A RISK CATEGORY II STRUCTURE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ)*) (FOR USE WITH A RISK CATEGORY II STRUCTURE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ)*) ;# RISK CATEGORY nice rnrrrnnv n is nrn ncrr y c _Q U 3 0 0 2 d II IS PER ASCE 7 16 ALLOWABLE ROOF -TOP HEIGHT (H) TIE -DOWN CONFIGURATION TYPE C1 C2 C3 C4 MAXIMUM SURFACE AREA OF UNIT'S LARGEST FACE UNIT HEIGHT UNIT WIDTH 6 FT2 29" MAX 15" MIN AT GRADE H <_ 200 FT AT GRADE H <_ 200 FT 9 FT2 36" MAX 27" MIN AT GRADE H <_ 200 FT AT GRADE H <_ 200 FT 4 FT2 48" MAX 36" MIN H <_ 160 FT H <_ 200 FT H <_ 200 FT H <_ 200 FT 6 FT2 H <_ 15 FT H <_ 200 FT H <_ 30 FT H <_ 200 FT 9 FT2 AT GRADE H <_ 200 FT AT GRADE H <_ 200 FT 12 FT2 N/A H <_ 60 FT N/A H <_ 100 FT 16 FT2 N/A H <_ 15 FT N/A H <- 15 FT 20 FT2 60" MAX 48" MIN N/A AT GRADE N/A AT GRADE 25 FT2 N/A AT GRADE N/A AT GRADE 30 FT2 N/A N/A N/A N/A 36 FT2 N/A N/A N/A N/A ALLOWABLE ROOF -TOP HEIGHT (H) TIE -DOWN CONFIGURATION TYPE C1 C2 C3 C4 MAXIMUM SURFACE AREA OF UNIT'S LARGEST FAC E UNIT HEIGHT UNIT WIDTH 6 FT2 29" MAX 15" MIN N/A H <_ 200 FT AT GRADE ;H <_ 200 FT 9 FT2 36" MAX 27" MIN N/A H <_ 140FT N/A H <_ 200 FT 4 FT2 48" MAX 36" MIN H <- 80 FT H <_ 200 FT H <- 140FT _- H <_ 2W FT 6 FT2 AT GRADE H <_ 200 FT AT GRADE H <_ 200 FT 9 FT2 N/A H <_ 160 FT AT GRADE H <_ 200 FT 12 FT2 N/A H <_ 30 FT N/A H <_ 40 FT 16 FT2 N/A AT GRADE N/A AT GRADE 20 FT2 60" MAX 48" MIN N/A AT GRADE N/A AT GRADE 25 FT2 N/A N/A N/A N/A 30 FT2 N/A N/A N/A N/A 36 FT2 N/A N/A N/A N/A *THIS TABLE IS PERMISSIBLE TO BE USED WITHIN THE HVHZ WHICH CONTAINS BROWARD AND *THIS TABLE IS PERMISSIBLE TO BE USED WITHIN THE HVHZ WHICH CONTAINS BROWARD AND MIAMI-DADE COUNTIES. CHECK WITH LOCAL AUTHORITY HAVING JURISDICTION FOR THE APPLICABILITY MIAMI-DADE COUNTIES. CHECK WITH LOCAL AUTHORITY HAVING JURISDICTION FOR THE APPLICABILITY LL OF THIS TABLE WITHIN CERTAIN FLORI DA COUNTIES. OF THIS TABLE WITHIN CERTAIN FLORIDA COUNTIES. z E °a ~ o Q VLLa ce o o Z ¢ wb u� d Ln _j O LL ^ U a U _ , z TABLE 3 PERMISSIBLE INSTALLATION HEIGHTS: VUlt=170 MPH, EXPOSURE C TABLE 4 PERMISSIBLE INSTALLATION HEIGHTS: VUlt=170 MPH, EXPOSURE D w a a' 0 N F Z i'D in N "' (FOR USE WITH A RISK CATEGORY II STRUCTURE**) (FOR USE WITH A RISK CATEGORY II STRUCTURE**) o z LL RISK CATEGORY I I IS PER ASCE 7-16 RISK CATEGORY II IS PER ASCE 7-16 CI --I G M v p 0C Q G U w ALLOWABLE INSTALLATION ROOF HEIGHT TIE -DOWN CONFIGURATION TYPE Cl C2 C3 C4 MAXIMUM SURFACE AREA OF UNIT'S LARGEST FACE UNIT HEIGHT UNIT WIDTH 6 ft2 29 in 15 in AT GRADE <_ 200 FT AT GRADE <_ 200 FT 9 ft2 36 in 27 in AT GRADE <_ 200 FT AT GRADE <_ 200 FT 4 ft2 48 in 36 in < 200 FT <_ 200 FT <— 200 FT <_ 200 FT 6 ft2 48 in 36 in H <— 30 FT <_ 200 FT H <— 40 FT <_ 200 FT 9 ft2 48 in 36 in AT GRADE <_ 200 FT AT GRADE <_ 200 FT 12 ft2 48 in 36 in N/A < 80 FT N/A <— 140 FT 16 ft2 48 in 36 in N/A H <— 15 FT N/A H <— 30 FT 20 ft2 60 in 48 in N/A AT GRADE N/A AT GRADE 25 ft2 60 in 48 in N/A AT GRADE N/A AT GRADE 30 ft2 60 in 48 in N/A N/A N/A AT GRADE 36 ft2 60 in 48 in N/A N/A N/A N/A ALLOWABLE INSTALLATION ROOF HEIGHT TIE -DOWN CONFIGURATION TYPE C1 C2 C3 C4 MAXIMUM SURFACE AREA OF UNIT'S LARGEST FACE UNIT HEIGHT UNIT WIDTH 6 ft2 29 in 15 in AT GRADE <_ 200 FT AT GRADE <_ 200 FT 9 ft2 36 in 27 in N/A < 200 FT AT GRADE <_ 200 FT 4 ft2 48 in 36 in < 120 FT <_ 200 FT <— 200 FT <_ 200 FT 6 ft2 48 in 36 in AT GRADE <_ 200 FT H <— 15 FT <_ 200 FT 9 ft2 48 in 36 in N/A < 200 FT AT GRADE <_ 200 FT 12 ft2 48 in 36 in N/A H <— 40 FT N/A H <— 60 FT 16 ft2 48 in 36 in N/A AT GRADE N/A AT GRADE 20 ft2 60 in 48 in N/A AT GRADE N/A AT GRADE 25 ft2 60 in 48 in N/A N/A N/A N/A 30 ft2 60 in 48 in N/A N/A N/A N/A 36 ft2 60 in 48 in N/A N/A N/A N/A T 1� C U G w n ~ U m ¢ LL f w W�m�c r m o w .s C3 0 0 m 0 $; Y U m m LL m z LL Z yzy w p�o� O J K J U CCfS �q�,�? z o UI o m m ?z o$ i5 0 o z H COP"RIGHTENGINEERING EXPRESSm T 20-26324 E SCALE: N.T.S. Q n OFI/}a� N V o **AS AN EXAMPLE, THESE TABLES ARE PERMISSIBLE TO BE USED WITHIN PALM BEACH COUNTY. CHECK WITH LOCAL AUTHORITY HAVING JURISDICTION FOR THE APPLICABILITY OF THESE TABLES WITHIN CERTAIN FLORIDA COUNTIES. STEEL T.L E-DOWN CUP _j n 0