Loading...
HomeMy WebLinkAbout4700 indrio rd fa.pdfSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Ross and Norann Chambers AGENT: Jared Modine PROPERTY ADDRESS: LOT 4700 Indrio Rd Fort Pierce, FL 34951 BLOCK: APPLICATION #:AP1528633 PERMIT # : 56-S F-2113466 DOCUMENT #:F11716460 DATE PAID . 06/02/2021 FEE PAID:240.00 RECEIPT #:56-PID-5009320 SUBDIVISION: ID # : 1418-133-0040-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1250.00 [21 483.00 [ ] [27] SURFACE WATER FT [ ] [021 TANK MATERIAL Concrete [ ] [281 DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 28-015-16DC3 2. 70-143-54SC4 [ ] [32] POTABLE WATER 100 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 8.5 FT [ ] [08] LEVEL [ ] [341 PROPERTY LINES 44 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 815.04 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] (371 SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 9.00 2. [ ] [38] SLOPES [ ] (131 DRAINLINE SEPARATION [ ] [39] STABILIZATION 10/06/2021 [ ] [14] DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 7.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS 1.00 [ ] [42] ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] (25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION St. Lucie CHD DISAPPROVED ] ° Environlpental Specialist III B ryJ Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED. / DISAPPROVED ]: U ram` St. Lucie CHD Environmental Specialist III r' n J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1528633 EID2113466 DATE: 06/15/2021 DATE: 10/18/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1528633 PERMIT # : 56-S F-2113466 DOCUMENT # : FI 1716460 DATE PAID : 06/02/2021 FEE PAID:240.00 RECEIPT #:56-PID-5009320 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 460 3pd• New ST, filter, DT, liberty 1/3 hp pump, and 9x8 long BED DF installed. No violations, system ok to cover, contractor notified by phone. Needs final inspection for mound system, final site grading, and scale survey with correct DF location. =inal system approved. Contractor emailed final approval DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v1.0.1 AP1528633 EID2113466