HomeMy WebLinkAboutAPPROVED REVISION 2, WS LOT 17 - ENERGY CALCSFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EDEN GOODMAN
Buiider Name: KHOVNANAIN HOMES
Street: 5158 ARMINA PL
Permit Office:
City, State, Zip: FT PIERCE, FL ,
Permit Number:
Owner: EDEN MODEL LOT 17 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41808.3 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1528.30 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
c. NIA
R= ft2
4. Number of Bedrooms 4
d. NIA
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (1618.0 sqft,)
Insulation Area
a. Under Attic (Vented)
R=30.0 1618.00 ft2
6. Conditioned floor area above grade (W) 1616
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(162.8 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.32 104.56 ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 325
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55 42.08 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.34
a. Central Unit
28.0 SEER:16.00
c. U-Factor: Dbl, U=0.32 16.19 ft2
SHGC: SHGC=0.27
Area Weighted Average Overhang Depth: 4.840 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.307
a. Electric Strip Heat
23.0 COP:1.00
S. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
9. Floor Types (1616.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2
b. Conservation features
EF:0.930
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.101 Total Proposed Modified Loads: 54.55
���S
Total Baseline
Loads: 56.67
I hereby certify that the plans and specifcations covered by
Review of the plans and
orftE ST
this calculation are in compliance with t Florida Energy
specifications covered by this
Code.
calculation indicates compliance,,,
L
with the Florida Energy Code.
F, .rxiref''.;
PREPARED BY: I
Before construction is completed
:.
W1 �
DATE: k V
this building will be inspected for
compliance with Section 553.908
1 hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
d� .
OWNER/AGENT:
BUILDING OFFICIAL, -
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/9/2021 6:31 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST
Title:
KHOV-EDEN GOODMAN
Building Type:
User
Owner Name:
EDEN MODEL LOT 17 @ W
# of Units:
1
Builder Name:
KHOVNANAIN HOMES
Permit Office:
Jurisdiction:
Family Type:
Detached
NewlExisting:
New (From Plans)
Comment:
PROJECT
Bedrooms:
4
Conditioned Area:
1616
Total Stories:
1
Worst Case:
No
Rotate Angie:
135
Cross Ventilation:
No
Whole House Fan:
No
CLIMATE
Address Type:
Street Address
Lot #
Block/Subdivision:
PlatBook:
Street:
5158 ARMINA PL
County:
St. Lucie
City, State, Zip:
FT PIERCE.,
FL,
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name Area Volume
1
Entire House 1616 14220.8
SPACES
Number
Name Area Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
1
BED 3 161 1416.8
No
1
4
1
No
Yes
Yes
2
HALL BATH 77 678
No
0
1
No
Yes
Yes
3
FOYER 172 1514
No
0
1
No
Yes
Yes
4
BED 4 149 1307
No
1
1
No
Yes
Yes
5
LAUNDRY 52 458
No
0
1
No
Yes
Yes
6
BED 2 149 1307
No
1
1
No
Yes
Yes
7
GIRT DIN KITCHEN 550 4840
No
0
1
No
Yes
Yes
8
MASTER SUITE 176 1544
No
2
1
No
Yes
Yes
9
MAST W[C 58 506
No
0
1
No
Yes
Yes
10
M BATH 72 634
No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio BED 3
38 ft
0
163 112
----
0
1
0
2 Slab -On -Grade Edge Insulatio HALL BATH
11 ft
0
77 ft2
___-
1
0
0
3 Slab -On -Grade Edge Insulatio FOYER
25 ft
0
172 ft2
----
1
0
0
4 Slab -On -Grade Edge Insulatio BED 4
14 ft
0
148.5 ftx
----
0
1
0
5 Slab -On -Grade Edge Insulatio LAUNDRY
1 ft
0
52 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio BED 2
13.5 ft 0
148.5 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio GIRT DIN KITCHE
49 ft
0
550 ft2
--__
0.25
0.5
0.25
10/9/2021 6:31 AM EnergyGaugeS USA 7.0.00 - RaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5 ft 0
175.5 ft2
___-
0 1 0
9 Slab -On -Grade Edge Insulatio MAST WIC 11.5 ft 0
57.5 ft2
----
0 1 0
10SIab-On-Grade Edge Insulatio M BATH 1 ft 0
72 ft2
----
1 0 0
ROOF
/ Roof Gable Roof
Rad
Solar SA Emitt
Emitt Deck Pitch
V # Type Materials Area Area Color
Barr
Absor. Tested
Tested Insul. (deg)
1 Hip Composition shingles 1750 ft2 0 ft2 Medium
N
0.9 No 0.9
No 0 22.6
ATTIC
J
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1616 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BED 3
30
Blown
163 ft2
0.1
Wood
2
Under Attic (Vented) HALL BATH
30
Blown
77 ft2
0.1
Wood
3
Under Attic (Vented) FOYER
30
Blown
172 ft2
0.1
Wood
4
Under Attic (Vented) BED 4
30
Blown
149 ft2
0.1
Wood
5
Under Attic (Vented) LAUNDRY
30
Blown
52 ft2
0.1
Wood
6
Under Attic (Vented) BED 2
30
Blown
149 it$
0.1
Wood
7
Under Attic (Vented) GRT DIN KITCHE 30
Blown
550 ft2
0.1
Wood
8
Under Attic (Vented) MASTER SUITE 30
Blown
176 ft2
0.1
Wood
9
Under Attic (Vented) MAST WIC
30
Blown
58 ft2
0.1
Wood
10
Under Attic (Vented) M BATH
30
Blown
72 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity Width
Height
Ft In
Area
Sheathing Framing Solar
P-\/;;I-,e Fraction Ahqnr
Below
0
1
NE=>S
Exterior Concrete Block - Int Insul BED 3
4.1 13
1 9
4
122A ft2
0
0
0.5
0
2
SE=>W
Exterior Concrete Block - Int Insul BED 3
4.1 10
8 9
4
99.6 ft2
0
0
0.5
0
3
SW=>N
Exterior Concrete Block - Int Insul BED 3
4.1 12
2 10
0
121.7 ft2
0
0
0.5
0
4
SW=>N
Exterior Concrete Block - Int InsL HALL BATH
4.1 9
11 10
0
99.2 ft2
0
0
0.5
0
5
SE=>W
Exterior Concrete Block - Int Insul FOYER
4.1 4
10 9
4
45.1 ft2
0
0
0.5
0
6
SW=>N
Exterior Concrete Block - Int Insul BED 4
4.1 12
7 10
0
125.8 ft2
0
0
0.5
0
7
NE=>S
Exterior Concrete Block - Int Insul BED 2
4.1 13
1 9
4
122.1 ft2
❑
0
0.5
0
8
SW=>N
Exterior Concrete Block - Int Ins(RRT DIN KIT
4.1 22
6 10
0
225.0 ft2
0
0
0.5
0
9
NW=>E
Exterior Concrete Block - Int InsQRT DIN KIT
4.1 12
3 9
4
114.3 ft2
0
0
0.5
0
10
NE=>S
Exterior Concrete Block - Int InsMASTER SUI
4.1 12
7 9
4
117.4 ft2
0
0
0.5
0
11
NW=>E
Exterior Concrete Block - Int InsMASTER SUI
4.1 12
7 9
4
117.4 ftz
0
0
0.5
0
12
NE=>S
Exterior Concrete Block - Int InsuMAST WIC
4.1 11
2 9
4
104.2 ft2
0
0
0.5
0
10/9/2021 6:31 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width
_
Height
Area
Sheathing Framing Solar
R-VaIlle Frantonn
Below
o
13 NW=>E Garage Frame - Wood FOYER 11 30 0 9
4 280.0 ft2
0
0 0.5
0
14 NW=>E Exterior Concrete Block - Int Ins@RT DIN KIT 4.1 12 3 9
4 114.3 ft2
0
0 0.5
0
DOORS
# Ornt
Door Type Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 NW=>E
Insulated FOYER None
.46 3
8
24 ft2
2 NW=>E
Wood FOYER None
.46 2.8
6.8
19 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to As Built rotated 135 de rees .
/ Wall
Overhang
V # Ornt ID Frame
Panes NFRC U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1 SE=>W 2 Metal
Double (Tinted) Yes 0.32 0.27 N
16.2 ft2 1 ft 0 in
1 ft 0 in
None
None
2 SW=>N 6 Metal
Double (Tinted) Yes 0.32 0.3 N
16.2 ft2 1 ft 0 in
1 ft 0 in
None
None
3 NE=>S 7 Metal
Double (Tinted) Yes 0.32 0.3 N
16.2 ft2 1 ft 0 in
1 ft 0 in
None
None
4 SW=>N 8 Metal
Double (Tinted) Yes 0.55 0.34 N
42.1 ft2 11 ft 0 in
1 ft 0 in
None
None
5 NW=>E 14 Metal
Double (Tinted) Yes 0.32 0.3 N
24.1 ft2 1 ft 0 in
1 ft 0 in
None
None
6 NW=>E 9 Metal
Double (Tinted) Yes 0.32 0.3 N
24.1 ft2 9 ft 6 in
1 ft 0 in
None
None
7 NW=>E 11 Metal
Double (Tinted) Yes 0.32 0.3 N
24.1 ft2 1 ft 0 in
1 ft 0 in
None
None
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wail Insulation
1 380 ft2
380 ft2 64 ft
8 ft
1
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391 1657.2 90.92 170.69 .1312
7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/ None CORI 23 kBtu/hr 1 Sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER: 16 28 kBtulhr 840 cfm 0.71 1 sys#1
10/9/2021 6:31 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHFCICI VAT RFPnRT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.93
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 325 ft2
HALL BATH 1 ft2
Default Leakage
HALL BAT
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling j Jan Feb
Heating X] Jan X�j Feb
Mar
MarApr
A r
Ma
May
X Jun X Jul
4 Jun 4 Jul
AuSe
rl Au
X Se
Oct Nov
Oct Xj Nov
Dec
Dec
Ventin [ ] Jan [ ] Feb
X Mar
I)C
A r
[
Ma
[ Jun ( Jul
Aug
Se
[X] Oct [X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80 80
80
PM
80
80
78
78
78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78 78
78
PM
78
78
78
78
78 78
78
78
78 78 78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68 68
68
PM
68
68
68
68
68 68
68
68
68 68 66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68 68
68
PM
68
68
68
68
68 68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
0 ft
0.3
BED 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL BATH
Default(8 Ibs/sq.ftr
ft2
ft
0.3
FOYER
Default(8 lbs/sq.ft.
ftz
ft
0.3
BED 4
Default(8 Ibslsq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibslsq.ft.
ft2
ft
0.3
BED 2
Default(8 Ibsfsq.ft.
ft2
ft
0.3
GIRT DIN KITCHEN
Default(8 Ibslsq.ft.
ft2
ft
0.3
MASTER SUITE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MAST WIC
Default(8 Ibsls .ft.
ft2
ft
0.3
M BATH
10/9/2021 6:31 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.27
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. NIA
5158 ARMINA PL, FT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4,1
1528.30 ft2
b. Frame - Wood, Adjacent
R=11 A
280.00 ft2
1
c. NIA
R=
ft2
4
d. NIA
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1618.00 ft2
1616
b. NIA
R=
ftz
Area
c. NIA
R=
ft2
104.56 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH
6 325
42.08 ft2
13. Cooling systems
kBtu/hr
Efficiency
16.19 ft2
a. Central Unit
28.0 SEER:16.00
ft2
4.840 ft.
0.307
Area
ft2
Insulation Area
R=0.0 1616.00 ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtulhr Efficiency
23.0 COP:1.00
Cap: 50 gallons
EF: 0.93
Pstat
IV;3 E $0
QD
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/9/2021 6:31 AM EnergyGaugeV USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1