Loading...
HomeMy WebLinkAboutAPPROVED, MS86155-OP445084-ROBERTMCCLELLAN-MS86155FINALDESIGNStamped (1)(1)COVER PAGE PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US COVER PAGE SYSTEAD INFORADATION MODULE HANWHA Q.PEAK DUO BLK-G6+/AC 340 INVERTER ENPHASE IQ7PLUS-72-2-US RACKING ROOFTECH RT-MINI & ECOFASTEN CLICKFIT 2-RAIL SYSTEM SYSTEM SIZE (DC)8.16 KW LOCATION 27.4191605,-80.3477459 HANWHA Q.PEAK DUO BLK-G6+/AC 340 340 WATT MODULE 68.5'' X 40.5'' X 1.57''(SEE DATASHEET) BUILDING INFORMATION/B.O.M. # STORIES 1/15 ROOF AREA 2453.34 P.V. AREA 462 ROOFING TYPE ASPHALT SHINGLES ROOF PITCH 10 # RAILS 12 # L-FOOT ATTACHMENTS 35 # MODULES 24 # INVERTERS 24 # SKIRTS 7 # ENPHASE COMBINER BOXES 1 EATON 60A FUSIBLE SOLAR AC DISCONNECT 1 40A FUSES 2 125A LINE TAPS 2 PLAN KEY PV-1 COVER PAGE PV-2 SITE PLAN PV-3 PANEL SPECIFICATION PV-3.1 PANEL LOAD TESTING RESULTS PV-3.2 INVERTER SPECIFICATION PV-3.3 COMBINER BOX SPECIFICATION PV-3.4 JUNCTION BOX SPECIFICATION PV-3.5 ATTACHMENT DETAIL PV-3.6 STRUCTURAL CALCULATION PV-3.7 SEALANT SPECIFICATION PV-3.8 SEALANT SPECIFICATION CONT. PV-4 THREE LINE DIAGRAM PV-4.1 ELECTRICAL NOTES PV-4.2 EQUIPMENT LABELS PV-5 STRUCTURAL CERTIFICATION STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE SECTION 1512 THROUGH 1525 AND SECTION 1616 THROUGH 1626 FOR HIGH VELOCITY HURRICANE ZONES. GENERAL NOTES: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA FIRE PREVENTION CODE, NEC 2017 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF FOR SLOPED ROOF AND NO MORE THAN 10-INCHES ABOVE THE SURFACE OF THE ROOF FOR FLAT ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO THE DESIGN CONSTRUCTION OR ALTERATION OF BUILDINGS AND STRUCTURES FOR HUMAN HABITATION. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 1 / 15 SCALE: 1/8" = 1'-0" SITE PLAN PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS. . THE LOCATION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAFTER LAYOUT START POINT, SPACING VARIATIONS AND ROOFING TYPE. VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WILL PRODUCE A STAGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGERED TILE JOINT LOCATIONS 3. EXISTING RESIDENCE EQUIPPED WITH SMOKE/CO DETECTOR IN AND OUTSIDE OF ALL SLEEPING ROOMS HARDWIRED AND INTERCONNECTED AS PER FEDERAL LAW ASPHALT SHINGLES SITE PLAN SYMBOL LEGEND MAIN SERVICE PANEL UTILITY METER SKYLIGHT VENT CHIMNEY SUB-PANEL MSP SP M SOLAR AC DISC UDC LC N3R CB SOLAR AC DISCONNECT LOAD CENTER NEMA 3R BOX W/ ENVOY-S COMBINER BOX PIPE VENT FAN SATELLITE DISH MODULE FIRE SETBACKS PITCH DIRECTION UTILITY DISCONNECT MIN 3'x3' GROUND ACCESS POINT WIND PRESSURE ZONE LINES ROOF PANEL COUNT TILT AZIMUTH SHADING R1 24 10°89°92% RAFTER SPACING 24" O.C. (TYP) TOTAL SQUARE FOOTAGE OF ROOF: 2454 SQFT SQUARE FOOTAGE OF SOLAR ARRAY:462 SQFT PERCENTAGE OF SOLAR ROOF COVERAGE: 18.85% 18" RIDGE SETBACK SHALL BE REQUIRED CLAMPING MAX SPACING IN ZONE 1 48" O.C AND IN ZONE 2 AND ZONE 3 48" O.C 51'-5" 51'-5" 58'-1"58'-1"FRONT OF RESIDENCEPLACID AVEMSP M SOLAR AC DISC ELECTRICAL EQUIPMENT CB PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ2e PZ2e PZ2e PZ2e PZ2e PZ2e PZ2e PZ2e PZ2e PZ2e PZ2n PZ2n PZ2n PZ2n PZ2rPZ2r PZ2rPZ2r PZ2rPZ2r PZ2rPZ2r PZ3rPZ3r PZ3e PZ3e PZ3e PZ3e PZ3r PZ3r PZ2 PZ2 PZ3 PZ3 PZ3 PZ3 PZ3 PZ3 PZ3 PZ3 5'-1" 5'-1"5'-1"5'-1"5'-1"5'-1"5'-1" 5'-1" 10'-2"10'-2" 10'-2"10'-2" 5'-1" 5'-1" 5'-1"5'-1" 5'-1"5'-1" 5'-1" 5'-1" 5'-1" 5'-1" R1 J-BOX GUTTERRIDGEGUTTERGROUND ACCESS (TYP) FIRE SETBACK (36" VENTILATION, 36" ROOF ACCESS) 3'-0" 3'-0" Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 2 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US PANEL SPECIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 3 / 15 PANEL LOAD TESTING RESULTS PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 4 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US INVERTER SPECIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 5 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US COMBINER BOX SPECIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 6 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.4 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US JUNCTION BOX SPECIFICATION JUNCTION BOX SPECIFICATION FOR SHINGLE ROOFS Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 7 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.5 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US ATTACHMENT DETAIL ATTACHMENT DETAIL FOR SHINGLE ROOF Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 8 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.6 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US STRUCTURAL CALCULATION 2-RAIL RACKING PLUS SOLAR SYSTEM DEAD LOAD COMPONENT WEIGHT/UNIT (LB)# MODULES 0 24 INVERTERS 4.0 24 RAILS (2-RAIL) @ 1.8LB/LF.1.8 12.0 ATTACHMENT/FLASHING 0.98 35 ARRAY TOTAL AREA (SQFT)462 ARRAY TOTAL WEIGHT (LB)152 TOTAL DEAD LOAD PER SF (LB/SQFT)2.60 10 % OF LEAST HORIZONTAL DIMENSION OR 40% OF THE BUILDING HEIGHT WHICHEVER IS SMALLER BUT NOT LESS THAN EITHER 4% OF THE LEAST HORIZONTAL DIMENSION OR 3'-0" WIND PRESSURE ZONE CALCULATION (ASCE FIGURE 30.4-2A, 2B) HORIZONTAL DIMENSION A 51.5'X 10% = 5.15' HORIZONTAL DIMENSION B 58.099998474121'X 10% = 5.80999984741211' BUILDING HEIGHT 15'X 40% = 6' PRESSURE ZONE WIDTH 5' 1.8 " CERTIFICATION OF WIND LOAD PRESSURE CALCULATION THIS IS A 2-RAIL DESIGN DESIGN LOAD CRITERIA. AS PER ASCE 7-16 (2.4.1) FOR THIS PARTICULAR CASE, THE "DOWNFORCE" CASE 2 AND UPLIFT HAVE BEEN TAKEN INTO CONSIDERATION. P (PSF) = 1xD + 1x PNET (DOWNFORCE) P (PSF) = 0.6xD + 0.6x PNET (UPLIFT) (P = TOTAL DESIGN LOAD) (PNET = WIND LOAD) (D = DEAD LOAD) PNET HAVE BEEN CALCULATED FOLLOWING THE ALLOWABLE STRESS DESIGN METHOD. THE MAXIMUM ABSOLUTE VALUE OF THE 2 CASES IS THE UPLIFT LOAD. THIS 2-RAIL DESIGN IS WELL UNDER THE CAPACITY OF THE INDIVIDUAL ATTACHMENT CAPACITIES FOR THE DESIGN. THE PHOTOVOLTAIC MODULES USED IN CONJUNCTION WITH 2-RAIL ATTACHMENT SYSTEM ADDED HAVE A DESIGN CAPACITY OF -4,000 PA., 84 PSF. THIS DESIGN IS WITHIN THE LOADING CAPACITIES OF THE PHOTOVOLTAIC MODULE 2-RAIL DESIGN TESTING CAPACITIES THAT HAVE BEEN PERFORMED BY INDEPENDENT TESTING BY THE PANEL MANUFACTURERS ENGINEERS. SEE ATTACHED MANUFACTURERS TEST DATA. WIND LOAD CALCULATIONS (ASCE 7-16 EQ. 29.4-7) VELOCITY PRESSURE Qh = 0.00256 Kz*Kzt*Kd*Ke*V^2(LB/SQFT) (EQ. 26.10-1) EXPOSURE B Kz (VELOCITY PRESSURE EXPOSURE)0.57 Kzt (TOPOGRAPHIC FACTOR)1 Kd (WIND DIRECTIONALITY)0.85 Ke (GROUND ELEVATION FACTOR)1 V (WIND SPEED)160 MEAN HEIGHT 15.00 TOTAL PRESSURE AND ATTACHMENT SPACING FOR GABLE ROOF WITH 7 to 20 DEGREE TILT GCp p- (LB/SQFT)p+ (LB/SQFT) pnet- (LB/SQFT)pnet+ (LB/SQFT) ATTACHMENT SPACING (INCH)UPLIFT PRESSURE FOR EACH ATTACHMENT (LB) ZONE UPLIFT DOWNWARD ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE 1 -2.00 0.30 -50.80 -76.21 7.62 -28.92 -44.16 10.22 48.00 24.00 -330.19 -252.10 2e -2.00 0.30 -50.80 -76.21 7.62 -28.92 -44.16 10.22 24.00 24.00 -165.10 -252.10 2n -3.00 0.30 -76.21 -114.31 7.62 -44.16 -67.02 10.22 24.00 24.00 -252.10 -382.60 2r -3.00 0.30 -76.21 -114.31 7.62 -44.16 -67.02 10.22 24.00 24.00 -252.10 -382.60 3e -3.00 0.30 -76.21 -114.31 7.62 -44.16 -67.02 10.22 24.00 24.00 -252.10 -382.60 3r -3.60 0.30 -91.45 -137.17 7.62 -53.31 -80.74 10.22 24.00 16.00 -304.30 -307.27 WIND PRESSURE PNET IS CALCULATED BY ASCE 7-16 EQ. 29.4.7, WHERE Qh IS CALCULATED BY EQ. 29.4-7 (PARAMETERS SHOWN IN THE TABLE). GCp ARE CHOSEN FROM FIGURE 30.3-A-I FOR SPECIFIC ROOF TYPE AND ROOF TILT WITH EFFECTIVE WIND AREA EQUALS TO 10 SQFT (INTERPOLATION MAY REQUIRED). ARRAY EDGE FACTOR rE = 1.5 FOR ARRAY EDGES UPLIFT PRESSURE IF ARRAY EDGE IS MORE THAN 10 FEET (0.5h) TO ROOF EDGES AND MORE THAN 4 FEET TO ADJACENT ARRAY OR NEXT ADJACENT PANEL. rE = 1.0 FOR ARRAY INTERIOR UPLIFT PRESSURE AND ALL DOWNWARD PRESSURE AS DEFINED IN ASCE 7-16 29.4.4. SOLAR PANEL PRESSURE EQUALIZATION FACTOR ra = 0.8 AS PER ASCE 7-16 FIGURE 29.4-8. NO PANEL ARE LOCATED IN ARRAY EDGE AREA AS DEFINED BY ASCE 7-16 29.4.4. FOR THIS PROJECT. ALLOWABLE LOAD / ATTACHMENT 5/16” LAG SCREW W/ 3.00” EMBEDMENT INTO RAFTER BELOW ACCORDING TO THE NATIONAL DESIGN SPECIFICIFICATION FOR WOOD CONSTRUCTION 2015 EDITION. = W' = W X CD X CT. - PER TABLE 11.3.1 NDS 5/16” DIA. 4" LONG LAG W/ 3.00” EMBEDMENT INTO 2X ROOF RAFTER W' = 266LB/IN EMBEDMENT (NDS11.3.1 TABLE 12.2A) FOR DF. LARCH, S.Y.P., AND S.P.F. SPECIES CD = 1.6 (TABLE 2.3.2 2015 NDS) CT = 1.0 (TABLE 10.3.4 2015 NDS) W' = 266LB/IN X 3.00” X 1.6 X 1.0 = 1,276.8LBS = ULTIMATE MAX ALLOWABLE UPLIFT PRESSURE WITH 60% OF ULTIMATE CAPACITY 1,276.8LBS X 0.6 = 766.08LBS -THREAD MUST BE EMBEDDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE. -LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER. -THESE VALUES ARE NOT VALID FOR WET SERVICE. -INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). TORQUE AS PER MANUFACTURERS SPECIFICATIONS. DO NOT OVER-TORQUE. -WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.3.1 IN THE AMERICAN WOOD COUNCIL NDS FOR WOOD CONSTRUCTION. Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 9 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.7 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US SEALANT SPECIFICATION SEALANT SPECIFICATION FOR SHINGLE ROOFS Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 10 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.8 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US SEALANT SPECIFICATION CONT. Roofing Read Safety Data Sheets before using this product. 19 Flashing Cement DESCRIPTION: KARNAK 19 Flashing Cement is a scientifically compounded composition of selected asphalts, mineral fibers, and refined solvents that are manufactured to a heavy consistency for application by trowel to provide a durable, elastic coating of excellent adhesion and high resistance to water and weathering. This product dries to a tough, flexible, waterproof and corrosion proof coating which gives excellent performance over wide ranges of temperature and weather conditions. KARNAK 19 Flashing Cement is available in 3 consistencies: Summer, Semi and Winter. USES: KARNAK 19 Flashing Cement is a general purpose cement for repairing leaks in shingles, concrete, metal or asphalt roofs, flashings on walls, chimneys, flues, downspouts and cornices. It is excellent for sealing cracks in concrete and brick, as a joint filler for precast roof slabs and for general purpose use in maintenance of exposed buildings and structures. SURFACE PREPARATION: All surfaces should be clean, dry and free from oil or grease, dust, dirt, loose paint or other foreign matter. Recommended application temperature is 40°F to 120°F. If applying at temperatures lower than 40°F, the substrate must be free of moisture and/or ice crystals. APPLICATION: Spread KARNAK 19 Flashing Cement to an average thickness of 1/8” (approximately 8 gallons per square) and press tightly into joints, seams or cracks. To repair large cracks, breaks and blisters: 1. Spread KARNAK 19 Flashing Cement over the damaged area. 2. Embed KARNAK Cotton, Fiberglass or Poly-Mat Membrane reinforcement. 3. Apply another coat of KARNAK 19 Flashing Cement over the entire patch. SPECIFICATIONS: Federal Specification SS-C-153 Type I (Except Non-Asbestos) ASTM D-4586 Type I Class I Revised 12.14.18 330 CENTRAL AVENUE, CLARK, NJ 07066 732-388-0300 • 800-526-4236 • FAX: 732-388-9422 WEB: http://www.karnakcorp.com Roofing Read Safety Data Sheets before using this product. 19 Flashing Cement PHYSICAL PROPERTIES: 1. Consistency: A smooth, heavy trowel consistency which will readily spread on and adhere to vertical and horizontal surfaces without sagging. 2. Character of Dried Film: Uniform, excellent adhesion to masonry, steel, cured concrete, shingles, asphalt roofing and a variety of other surfaces. 3. The dried film retains its flexibility and ductility so that the coating will resist extreme variations in temperature and weather. 4. Has excellent resistance to flow at high temperatures when used on a vertical surface. CAUTION: Do not use near open flame. Material is for building exterior applications only. Avoid breathing solvent fumes and prolonged contact with skin. Do not take internally. If swallowed, do not induce vomiting. Call a physician immediately. Keep out of reach of children. Keep container covered when not in use. Do not thin. Dispose of in an environmentally safe manner. Cover air intakes during application and while drying. PACKAGING: Available in 5 gallon, 3 gallon, 1 gallon cans and 10.1 oz. caulk tubes. If further information is needed, contact Karnak Technical Services at 1-800-526-4236. Revised 12.14.18 330 CENTRAL AVENUE, CLARK, NJ 07066 732-388-0300 • 800-526-4236 • FAX: 732-388-9422 WEB: http://www.karnakcorp.com Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 11 / 15 ENPHASE 80A AC COMBINER BOX 10A/15A BREAKER (MANUFACTURER SUPPLIED FOR ENVOY) 20A BREAKER (A) 20A BREAKER (B) 2A 2B 3 GND NEU TERMINATION CAP INSTALLED ON END OF CABLE INVERTERS INSTALLED ON RAIL SYSTEM =...== =...== 1A TO 1B ROOF JUNCTION BOX BRANCH CIRCUIT A 12 MICRO-INVERTERS BRANCH CIRCUIT B 12 MICRO-INVERTERS 24 HANWHA Q.PEAK DUO BLK-G6+/AC 340 340W MODULES PAIRED WITH 24 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS GND BUS NEU BUS POWER GROUND EXISTING SQUARE D 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 200A 200A UTILITY METER GRID GND BUS NEU BUS POWER GROUND EXISTING SQUARE D 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 200A 200A UTILITY METER GRID GND NEU 4 EATON 60A FUSIBLE SOLAR AC DISCONNECT 40A 40A FUSES SOLAR CIRCUIT DISCONNECTING MEANS GND BUS NEU BUS POWER GROUND EXISTING SQUARE D 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 200A 200A UTILITY METER GRID PV SYSTEM CURRENT 36.3 A SOLAR AC DISCONNECT EMPHASE COMBINER BOX EXISTING METER MSP LOCATED INSIDE OF STRUCTURE MSP METER RISER #2/0 AWG SERVICE CONDUCTOR FROM OVERHEAD FOR 200AMP SERVICE HOT LINE TAPS MINUMUM BEND RADIUS 4" ENCLOSURE DIMENSIONS LENGTH: 21.31" WIDTH:10.3" DEPTH:9.06" #2/0 AWG SERVICE CONDUCTOR FROM UTILITY METER FOR 200AMP SERVICE Wire Tag Conduit Wire Qty Wire Gauge Wire Type Temp. Rating Wire Ampacity (A) Temp. Derate Conduit Fill Derate Derated Ampacity (A) Inverter Qty NOC (A)NEC Correction Design Current (A) Ground Size Ground Wire Type 1A TO 1B OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 12 1.21 1.25 18.15 06 AWG BARE CU 2A 1” PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 2B 1” PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 3 1” PVC 3 + G 08 AWG THWN-2 75°C 50 0.96 1 48.00 24 1.21 1.25 36.30 08 AWG THWN-2 4 1” PVC 3 + G 06 AWG THWN-2 75°C 65 0.96 1 62.40 24 1.21 1.25 36.30 THWN-2 THREE LINE DIAGRAM PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-4 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US ELECTRICAL SERVICE ELEVATION INTERCONNECTION DETAIL NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 12 / 15 ELECTRICAL NOTES SUB PANEL BREAKER SIZE # OF MODULES PV BREAKER PER BRANCH UP TO 16 20A PV ADODULE RATINGS MODULE MAKE HANWHA MODEL Q.PEAK DUO BLK-G6+/AC 340 MAX POWER 340W OPEN CIRCUIT VOLTAGE 40.66V MPP VOLTAGE 33.94V SHORT CIRCUIT CURRENT 10.52A MPP CURRENT 10.02A NUMBER OF MODULES 24 UL1703 COMPLIANT YES INVERTER RATINGS INVERTER MAKE ENPHASE MODEL IQ7PLUS-72-2- US MAX OUTPUT POWER 290W OPEN DC VOLTAGE 60V NOMINAL AC VOLTAGE 240V MAX AC CURRENT 1.21A CEC INVERTER EFFICIENCY 97% NUMBER OF INVERTERS 24 UL1703 COMPLIANT YES VOLTAGE DROP CALCULATIONS FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE WIRE RUN Vmp Imp R L (FT)Vo % Vo WIRE SIZE BRANCH TO J-BOX 240.00 J-BOX TO LOAD CENTER 240.00 LOAD CENTER TO AC DISCONNECT 240.00 AC DISCONNECT TO INTERCONNECTION 240.00 #NUM!1.98 #NUM!#NUM!#NUM!12 AWG 0 1.24 50.00 0.000 0.00%10 AWG 0 1.24 3.00 0.000 0.00%10 AWG 0 1.24 10.00 0.000 0.00%10 AWG PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-4.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US MAKE MODEL VOLTAGE RATING CONDUCTOR RANGE MAIN CONDUCTOR RANGE TAP ILSCO IPC 4020 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4006 600 V 4/0-2 AWG 2/0-6 AWG INSTRUCTIONS FOR LINE TAPS FIGURE 1: 1.ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2.PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3.INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4.TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5.SCREW THE NUT WITH THE SLEEVE SPANNER. 6.SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND DROPPED DOWN THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE 1.ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFFICIENTS. 2.THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER WIRE. 3.THIS SYSTEM COMPLIES WITH NEC 2017 4.BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7.INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8.CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9.EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10.ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) 11.PER NEC 690.13, 690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. 12.PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13.INTERCONNECTION METHOD SHALL COMPLY WITH NEC705.12 14.AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB-CIRCUIT BRANCHES IS ACCEPTABLE. ELECTRICAL NOTES: 15.ALL CONDUCTORS MUST BE COPPER. 16.NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17.EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18.FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19.SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20.METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22.WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 25.TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 28.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29.ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30.NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(A) OR 705.12(B) Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 13 / 15 29.04 ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING QUANTITY LOCATION A LABELTAG B C 1 JUNCTION BOX 1 COMBINER BOX 1 AT ANY COMBINER BOX 1 AT ANY JUNCTION BOX NOTE EXAMPLES A B DC RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE A 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT WARNING: PHOTOVOLTAIC POWER SOURCE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC SOLAR VOLTAGE 12 AC CONDUITS 1 AT EVERY SEPARATION BY ENCLOSURES / WALLS / PARTITIONS / CEILINGS / FLOORS OR NO MORE THAN 10' F G BACKFEED ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING CAUTION 29.04 D POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR GENERATION AC SYSTEM DISCONNECT CAUTION E F 1 INTERCONNECTION POINT 1 UTILITY METER 1 AC DISCONNECT (RAPID SHUTDOWN SWITCH, MAX 3FT FROM SERVICE DISCONNECT) 1 OF EACH AT FUSED AC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON DISCONNECT LABEL 1 OF EACH AT BUILDING INTERCONNECTION POINT AND ONE DIRECTORY PLACARD 1 AT UTILITY METER AND ONE DIRECTORY PLACARDREVENUE METER DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 1 G DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING BACKFEED PANEL 1 PV METER SOCKET 1 AT PV METER SOCKET AND ONE DIRECTORY PLACARD PV METER WARNING TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN ENTIRE PV SYSTEM SOLAR ELECTRIC PV PANELS SECTIONS OF THE PV SYSTEM THAT ARE SHUT DOWN WHEN THE RAPID SHUTDOWN SWITCH IS OPERATED SECTIONS OF THE PV SYSTEM THAT ARE NOT SHUT DOWN WHEN THE RAPID SHUTDOWN SWITCH IS OPERATED EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM INSTALLED BY MOMENTUM SOLAR 3096B HAMILTON BLVD S. PLAINFIELD, NJ 07080 PHONE NUMBER:732-902-6224 EQUIPMENT LABELS PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-4.2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 14 / 15 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-5 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ROBERT MCCLELLAN - MS86155 2809 PLACID AVE FORT PIERCE, FL 34982 7723327842 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/17/2021 SYSTEM SIZE (DC ): 8.16 KW 24 MODULES: HANWHA Q.PEAK DUO BLK-G6+/AC 340 24 INVERTERS: ENPHASE IQ7PLUS-72-2-US STRUCTURAL CERTIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2021.09.17 05:09:10 -05:00 Powered by TCPDF (www.tcpdf.org) 15 / 15