HomeMy WebLinkAboutEnergy Efficiency Compliance for Swimming Pool1
A"I The Association of
v�� Pool & Spa Professionals'
ANSI/APSPACC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS
PROJECT NAME:
AND ADDRESS
Buchanon POOL
CONTRACTOR NAME
AND ADDRESS:
OASIS POOLS & SPAS OF THE TREASURE COAST
1453 W ISLAND CLUB SQ
665 4TH STREET
VERO BEACH,FLORIDA 32963
VERO BEACH, FLORIDA 32962
OWNER: Jeffery BUChanon
CONTRACTOR PHONE: 772-226-7196
DATE: 7-22-21
This into rmation sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa
Professionals (APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only. Contractors should acquire and comply
with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org.
1. §5.2.1: Calculated pool volume
a. Gallons: 9975 : or =allons
b. Calculated Gallons: (surface area) X (average depth) X 7.48 (gal/R^3) =_0
2. §5.2.1: Calculated maximum filtration flow rate 12. 36 apm
(Pool volume _ 360 or 36gpm whichever is larger)
3. §5.2.2: Auxiliary Pool Load: Yes, ✓ No?
(Enter the highest 'auxiliary pool load" to be powered by the swimming pool filtration pump. Do not add auxiliary 3. gpm _
pool load flow rates together, only the highest is used.)
4. Calculated maximum flow rate 4. 36 apm
(Item 2 or item 3, whichever is larger.)
S. §5.5.1: Pipe sizing:
a. Minimum suction pipe diameter 5a. 1.5 inches _
(Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than item 4.)
b. Minimum suction branch pipe diameter 5b. 1.5 inches _
(Calculate: Item 4. 36 (qpm) = Branch Pipes 1 (quantity) = branch flow rate 36 (gpm),:
Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than the calculated
suction branch flow rate.)
c. Minimum return pipe diameter 5c. 1.5 inches _
(Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than item 4.)
d. Minimum return branch pipe diameter 5d. 1.5 inches _
(Calculate: Item 4. 36 (qpm) _ Branch Pipes 1 (quantify) = branch flow rate 36 (qy m).
Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than the calculated
return branch flow rate.)
6. §5.4.1: Filter type and size:
a. Filter type: (Cartridge, DE, Sand)
b. Minimum filter area 6b. 96 sq. ft. —
(Calculate: item 4. 36 (aom) -filter factor 0.375 ) '
Filterfactors: Cartridge=0.375, Sand=15, Diatomaceous Earth=2
7. §5.4.2: Backwash valve: _Yes, ✓ No? 7. 2.0 inches —
(When using a backwash valve, enter result of item Sc or 2 inches whichever is larger)
Table 1
I' Pipe Size:
1.5"
2"
2.5"
3"
1 3.5"
4"
5"
y 6"
Nominal GPM @ 6 fps
38
63
90
138
185
238
374
540
Nominal GPM @ 8 fps
51
84
119
184
247
317
499
720
S. Pump selection: 1110
§5.3.2.1: Pools 17,000 gallons or less, select pump* from the database with a Curve -A gpm flow equal to item 2 or kov
§5.3.2.2: Pools 17,001 gallons or more, select pump* from the database with a Curve-C gpm flow equal to item 2 or less. *Multi -
speed pumps must have onespeed listed that satisfies this requirement.
a. Pump model
b. Pump flow
(§5.3.2.1, 5.3.2.2: Applicable Curve A or C gpm flow listed in database)
.M,
4/5/12 ANSI/APSP/ICC- 15 Standard Writing Committee Form 1 of 2
ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS
Component
Section
Requirements
Check
Heaters
4.4.1.1
Heater has no pilot light
4.4.1.2
Readily accessible on -off switch mounted outside of the heater
4.3.1.3
No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation,
or for pool with 60% of documented pool heating from on -site solar or recovered energy.
4.3.2
Heater efficiency: gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0
Pool systems
5.1.1
Pool filter pump listed in database
5.3.1
Pool filter pump with total horsepower 1.0 or more is multi -speed
5.3.3
Multi -speed pump controller programmed to default to the filtration flow rate when no auxiliary
pool loads are operating within 24 hours and programmed with temporary override capability for
servicing.
5.3.4
Single -speed pump controller capable of operating pump during off-peak electric demand.
5.5.2
Pipe before pump has at least 4 diameters of straight pipe.
5.5.3
System installed with solar, or setup for the future addition of solar heating equipment by
installing 18 inches of horizontal or vertical pipe after the filter and before a heater, or built-in or
built-up connections, or dedicated pipe to and from the pool.
5.5.6
Directional inlets for mixing pool water.
4/5/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 2 of 2