FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: JONATHAN GOODHUE
Builder Name:
Street: 113 NE NARANJA AVE.
Permit Office:
City, State, Zip: PORT ST. LUCIE, FL,
Permit Number:
Owner: JONATHAN GOODHUE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing
Addition
10. Wall Types(416.0 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Ext Insul, ExterioR=0.0 416.00 ft
b.c.
3. Number of units, if multiple family
1
NIA
R= ft'
4. Number of Bedrooms
0
d. NIA
R= ft`
5. Is this a worst case?
No
11. Ceiling Types(441.0 sgft.)
Insulation Area
6. Conditioned floor area above grade (ft2)
441
a. Under Attic (Vented)
R=19.0 441.00 ft
Conditioned floor area below grade (ft')
0
b. NIA
c. NIA
R= ftz
R= ft-
7. Windows(0.0 sgft.) Description
Area
12. Ducts, location & insulation level R ft'
a. U-Factor: NIA
ft2
a.
SHGC:
b,
b. U-Factor: NIA
ft2
C.
SHGC:
13. Cooling Systems
kBtulhr Efficiency
c. U-Factor: NIA
ft2
a. Central Unit
9.0 SEER:18.50
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft
Area Weighted Average SHGC:
0.000
14. Heating Systems
kBtulhr Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
9.0 HSPF:10.00
U-Factor:(AVG) NIA
NIA ftz
SHGC(AVG): NIA
9. Floor Types Insulation
Area
15. Hot Water Systems - None required
a. Slab -On -Grade Edge Insulation R= 0.0
441.00 ft 2
a. Zu@
Cap: WA
c.
2
b. Conservation features
NIA R=
ft2
16. Credits
None
Glass/Floor Area:0.0 Total Proposed Modified Loads: 12.53
Total Baseline
Loads: 13.26
PASS
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida
Energy
specifications covered by this
p4�H� SraTtp
Code.
calculation indicates compliance'
with the Florida Energy Code.
'' s
PREPARED BY:
Before construction is completed
this building will be inspected for
DATE: 10-8-2021
compliance with Section 553.908
Florida Statutes.
t;OD
I hereby certify that this building, as designed, is in compliance
WE
with the Florida Energy Code.
OWNERIAGENT:e-C
BUILDING OFFICIAL: _
DATE: i0 - ZI
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Proposed On of NAN exceeds the performance method default limit of 0.08
and therefore does not require duct testing. R405 .2.3
Compliance requires an Air Sarrien and Insulation Inspection: Choc:dlst In accordanco with 0.1402.4.1.1 and thin pro;eet
rem.ire� a DrocnolmA k1!`e an.•elnne laa4ene fee# re"~+ a 14h envelnne l-t- nn nr +ar lhen 4 nn At URA MAW) A i 'M
10/8/2021 3:21:05 PM EnergyGaugeg USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compiant Software Paq e
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: JONATHAN GOODHUE
Building Type: User
Owner: JONATHAN GOODHUE
BuiiderName:
Permit Office:
Jurisdiction:
FamilyType: Detached
NewlExisting: Addition
YearConstruct:
Comment:
Bedrooms: 0
ConditionedArea: 441
Total Stories: 1
Worst Case: No
RotateAngle: 0
Cross Ventilation: No
Whole House Fan: No
Terrain: Suburban
Shielding: Suburban
Addresstype: StreetAddress
Lot#: —
Block/SubDivision: --
P1atBook: —
Street: 113 NE NARANJA AVE.
County: St. Lucie
City, State, Zip: PORT ST. LUCIE,
FL,
CLIMATE
JDesign
Location
Tmy Site
Design Temp
97.5% 2.5°%
Int Design Temp Heating Design Dailytemp
Winter Summer Degree Days Moisture Range
_FL, Fort Pierce
FL_VERO_BEACH_MUNICIPA 39 90
70 75 299 62 Low
BLOCKS
Number Name
Area
Volume
1 Entire House
441
3528
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms Finished Cooled Heated
1 GAR
441
3528 No 0
Yes Yes Yes
FLOORS
(Total Exposed Area = 441 sq.ft.)
# FloorType
Space
Exposed Perim PerimeterR-Value Area U-Factor JoistR-Value Tile Wood Carpet
1 Slab -On -Grade Edge Ins
GAR
52 0
441 ft 0.473 --- 0.00 1.00 0.00
ROOF
, /
V # Type
Materials
Roof Gable Roof
Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1 Hip
Composition shingles 465 ft' 0 W Medium N 0.6 No 0.9 No 0 18.43
ATTIC
# Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1 Full attic
Vented
150 441 ftz N N
CEILING
(Total Exposed Area = 441 sq.ft.)
# CeilingType
Space R-Value Ins Type Area U-Factor Framing Frac. Truss Type
1 tlnrtPrA#ir(VPnt.-d)
GAR 19 n Blown
441 nft2 n n034 O in Wood
10/8120213:21:05 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software page 2
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
(Total Exposed Area = 416 sq.ft. )
V# Adjacent
Ornt To Wall Type
Cavity Width
Space R-Value Ft In
Height Area U- Sheath Frm. Solar Below
Ft In sq.ft. Factor R-Value Frac. Absor. Grade
-1
_ 2
_ 3
SE Exterior Conc. Blk - Ext Ins GAR 0.0 10.0 0
SW Exterior Conc. 81k - Ext Ins GAR 0.0 21.0 0
NW Exterior Conc. Blk - Ext Ins GAR 0.0 21.0 0
8.0 0 80.0 0.284 0 O 0.50 0 %
8.0 0 168.0 0.284 0 0 0.50 0 %
8.0 0 168.0 0.284 0 0 0.50 0 %
DOORS
(Total Exposed Area = 133 sq.ft.)
V#
Ornl Adjacent To DoorType
Space Storms
Width Height
U-Value Ft In Ft In Area
-1
2
SW Insulated
NW Insulated
GAR None
GAR None
0.38 16.00 0 7.00 0 112.0ft2
0.28 3.00 0 7.00 0 21.0ft2
INFILTRATION
#
Scope Method
SLA CFM50 ELA EgLA
ACH ACH50 Space(s)
1
Wholehouse ProposedACH(50)
0.00025 294 16.13 30.28
0.0902 5.0 All
MASS
#
Mass Type
Area Thickness
Furniture Fraction Space
1
Default(Blbslsq.ft.)
0 ft2 0 ft
0.30 GAR
HEATING SYSTEM
#
System TypelFl.Addition Subtype/Speed AHRt# Efficiency Capacity --GeothermalHeatPump---- Ducts Block
kBtulhr Entry Power Volt Current
1
Electric Heat Pump/Existing/co
Split/Single HSPF:10.00
9.0 0.00 0.00 0.00 sys#O 1
COOLING SYSTEM
#
SystemTypelFl.Addition Subtype/Speed AHRI# Efficiency
Capacity Air Flow SHR Duct Block
kBtulhr cfm
-1
Central UnitlExistinglco
Split/Single SEER:18.5
9.0 0 0.70 Ductless 1
HOT WATER SYSTEM
#
SystemType Subtype
Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipelength
Recirculation RecircControl
System Type
Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
length length power Connected Flow Eff
DUCTS
/Duct ---------Supply Return---------
V # Location R-Value Area Location R-Value Area LeakageType
Air CFM 25 CFM 25 HVAC #
Handler TOT OUT QN RLF Heat Cool
10/8/2021 3:21:05 PM EnergyGaugoO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
DUCTS(Continued)
TEMPERATURES
ProgramableThermostat: N
Ceiling Fans: N
Cooling []Jan
[] Feb
[] Mar
[ )Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep
[ ] Oct
[ ] Nov
[I Dec
Heating [X] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ] May []Jun [] Jul
[ ] Aug
[ ] Sep
[ ] Oct
[X] Nov
[X] Dec
Venting [ ] Jan
[] Feb
[X] Mar
[X] Apr
[ ]may []Jun []Jul
[ ] Aug
[I Sep
[X] Oct
[X] Nov
[I Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8
9
10 11
12
_Cooling (WD)
AM
78
78
78 78 78 78
78
78
80
80
80
80
PM
80
80
80 80 78 78
78
78
78
78
78
78
Cooling (WEN)
AM
78
78
78 78 78 78
78
78
80
80
80
80
PM
80
80
80 80 78 78
78
78
78
78
78
78
Heating(WD)
AM
65
65
65 65 65 65
65
68
68
68
68
68
PM
68
68
68 68 68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65 65 65 65
65
68
68
68
68
68
PM
68
68
68 68 68 68
68
68
68
68
68
68
10l8120213:21.05PM EnergyGauge® USA 7.0.00-FlaRes2020FBC7thEdition (2020)Compliant Software Paur4
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name: JONATHAN GOODHUE Builder Name:
Street: 113 NE NARANJA AVE. Permit Office:
City, State, Zip: PORT ST. LUCIE, FL, Permit Number: Y
Owner: JONATHAN GOODHUE Jurisdiction: U
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) s
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air-penneableinsulationshall
requirements
The exteriorthermal envelope containsa continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffd
Cellinglattic
the insulation and any gaps in the air barriershall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the lop of exterior walls shall be
shall be insulated by completely filling the cavitywith
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exterior thermal envelope insulation forframedwalls
shall be installed in substantial contact and
continuous alignmentwith the air barrier.
Windows, skylights
The space between windowldoorjambsand framing, and
and doors
skylights and framing shall be sealed.
Rimjoists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floorframing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
andcantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, oroontinuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floor insulation, insulation
with a Class I vapor retarder with overlapping joints taped
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrowcavities
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garageseparation
Airsealingshall beprovided between the garage and
conditionedspaces.
Recessed lighting
Recessed light fixtures installed in the building thermal
Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and p umbing in exteriorwalls, or insulation that on
installation readily conformsto availablespace shall
extend behind piping and wiring.
Shower/tub
The air bamerinstalled atexteriorwallsadjacent toshowers
Exterior walls adjacent to showers and tubs shall
onexteriorwall
and tubs shall separate them from the showers and tubs.
beinsulated.
Electrical/phonebox
The air barrier shall be installed behind electrical or
onexteriorwalls
communication boxes or air -sealed boxes she I be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
Spfillru Is
UC itWWU III d I I Idl II Nil UIdt 161 UWI f1111W WeU Uy U Ikd 111dI Iu1d41Urei.
Caulking orother adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls she I be in accordance with the provisions of ICC400.
10/8/2021 3:21:05 PM EnergyGauge@) USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
113 NE NARANJA AVE.,PORT ST. LUCIE,FL,
1. New construction or existing
Addition
10. Wall Types(416.0 sqft.)
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Ext Insul, ExterioR=0.0
416.00 ft'
3. Number of units, if multiple family
1
c. NIA
R=
ft7
4. Number of Bedrooms
0
d. NIA
R=
ft2
5. Is this a worst case?
No
11. Ceiling Types(441.0 sgft.)
Insulation
Area
6. Conditioned floor area above grade (fts)
441
Under Attic (Vented)
b. NIA
R=19.0
441.00 fe
Conditioned floor area below grade (ft2)
0
c. NIA
R=
R=
fea.
fe
7. Windows— Description
Area
12. Ducts, location & insulation level
R fe
a. U-Factor: NIA
ftz
a.
SHGC:
b.
b. U-Factor: NIA
ft2
C.
SHGC:
13. Cooling Systems
kBtulhr
Efficiency
c. U-Factor: NIA
ft2
a. Central Unit
9.0 SEER:18.50
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft
Area Weighted Average SHGC:
0.000
14. Heating Systems
kBtulhr
Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
9.0 HSPF:10.00
U-Factor:(AVG) NIA
NIA ftz
SHGC(AVG): NIA
9. Floor Types Insulation
Area
15. Hot Water Systems - None required
a. Slab -On -Grade Edge Insulation R= 0.0
441.00 ftz
a. 2u@
Cap: N/A
z
b. Conservation features
c. NIA R=
ft2
16. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card wirl be competed
based on installed Code compliant features.
Builder Signature: lyn!PK Date:
10 -t—Z1
Address of New Home: 113 NE NARANJA AVE. City/FL Zip: PORT ST. LUCIE,FL,
*Note: This is not a Bui'ding Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Bui;ding Commission's support staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1018/20213:21:05 PM EnergyGaugeGr} USA 7.0.00 - FlaRes202O F8C 7th Edition (2020) Compliant Software Page 1 of 1