Loading...
HomeMy WebLinkAboutPermit WorksheetsMobile Home Permit Worksheet Application Number: Date: Installer: EDDIE GRUNDEL License # IH1118467 Address of home 2062 NETTLES BLVD New Home O✓ Used Home ❑ Home installed to the Manufacturer's Installation Manual e✓ Home is installed in accordance with Rule 15-C being installed JENSEN BCH Single wide ❑ Wind Zone II Wind Zone III �✓ JACOBSEN 20X49/43 Double wide [ Installation Decal # TBD Manufacturer Length x width Triple/Quad Serial # TBD NOTE. if home is a single wide fill out one half of the blocking plan if home is a triple or quad wide sketch in remainder of home PIER SPACING TABLE FOR USED HOMES I understand Lateral Arm Systems cannot be used on any home (new or used) where the sidewall ties exceed 5 ft 4 in. Installer's initials EG Typical pier spacing �, ' I lateral 6IYY� Show locations of Longitudinal and Lateral Systems longitudinal (use dark lines to show these locations) I -; i-------------------- -- ---- - - ---- -- - --------- -- - ---------------- -----� Li Li Lj L-i Li marriage F1 wall Li piers M within 2' of end M of home per — ule 15C 171 =41 Load bearing capacity Fouter si3 e (sq i,n) 16" x 16" (256 ) 18 1 /2" x 18 1/2" (342 ) 20" x 20" (400) 22" x 22" (484)* 24" X 24" (576)* 26" x 26" (676) 000 psf 3 4 5 7 8' 500 sf 4' 6' 6 7 8 8' 2000 s 6' 8 8 8' 00 psf 7 8 8 3000 psf 8' 8 8 8 8 8' 500 pst 8' 8 8 8 8' mterpulateu uurn mule I au- I pier spacing [axle. PIER PAD SIZES -beam pier pad size 17X22.5 Perimeter pier pad size 16X16 Other pier pad sizes (required by the mfg.) Draw the approximate locations of marriage wall openings 4 foot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. Opening Pier pad size P PULAR PAD IZE Pad ize Sig In 16 x 16 x 288 5 x .5 42 6 x 22.5 360 7 x 22 74 13 4 x 4 348 20 x 2U 400 -17 6x25 44 7 2x 25 6 2 x 24 576 26 x 2 67 ANCHORS X ,�, Mobile Home Permit Worksheet POCKET PENETROMETER TEST The pocket penetrometer tests are rounded down to 1500 psf or check here to declare 1000 lb. soil without testing. X 1,500 X 1,500 X 1,500 POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the Tooter. 3. Using 500 lb. increments, take the lowest reading and round down to that increment. X 1,500 X 1,500 X 1,500 TORQUE PROBE TEST The results of the torque probe test is 290 inch pounds or check here if you are declaring 5' anchors without testing . A test showing 275 inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may requires anchors with 4000 lb holding capacity. Installer's initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Installer Name EDDIE GRUNDEL Date Tested Electrical Connect electrical conductors between multi -wide units, but not to the main power source. This includes the bonding wire between mult-wide units. Pg. Plumbina Connect all sewer drains to an existing sewer tap or septic tank. Pg. Connect all potable water supply piping to an existing water meter, water tap, or other independent water supply systems. Pg. Application Number: Date: Site Preparation Debris and organic material removed X Water drainage: Natural Swale Pad X Other Fastening multi wide units Floor: Type Fastener: LAG Length: 6" Spacing: 24" Walls: Type Fastener: LAG Length: 6" Spacing: 24" Roof. Type Fastener: GALV Length: CONT Spacing: 24" For used homes a min. 30 gauge, 8" wide, galvanized metal strip will be centered over the peak of the roof and fastened with galv. roofing nails at 2" on center on both sides of the centerline. Gasket (weatherproofing requirement) I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initials Type gasket FACTORY FOAM Installed: Pg. Between Floors Yes X Between Walls Yes X Bottom of ridgebeam Yes X Weatherproofing The bottomboard will be repaired and/or taped. Yes X . Pg. Siding on units is installed to manufacturer's specifications. Yes X Fireplace chimney installed so as not to allow intrusion of rain water. Yes X Miscellaneous Skirting to be installed. Yes X No Dryer vent installed outside of skirting. Yes X N/A Range downflow vent installed outside of skirting. Yes X N/A Drain lines supported at 4 foot intervals. Yes X Electrical crossovers protected. Yes X Other: installer verifies all information given with this permit worksheet is accurate and true based on the manufacturer's installation instructions and or Rule 15C-1 & 2 i'0A Installer Signature Date