Loading...
HomeMy WebLinkAboutResidential Heat Loss and Heat Gain CalculationPage 1 Residential Heat Loss and HeatGain Calculation 10/14/2019 In accordance with ACCA Manual J Report Prepared By: Central Air Systems Inc. For: Design Conditions: West Palm Beach Indoor: Outdoor: Summer temperature: 70 Summer temperature: 91 Winter temperature: 70 Winter temperature: 45. Relative humidity: 55 Summer grains of moisture: 126 Daily temperature range: Medium Building Component Sensible Latot Total Total Gain Gain Heat Gain Heat Loss (BTUH). (BTUH) (BTUH) (BTUH) Duct 857 0 1. 867 0 Floors 0 0 0 1,056 Walls 2,174 0 2,174 2,209 Ceilings 3,136 0 3',1.36 1,742 People _ .0 0 0. 0 Fireplaces 0 0 0 0 Misc 0 00 0 Windows 8,192 0 8,192 3,032 Doors Glassdoors 261 1,737 0 261 0 1,737 265 1,077 Skylights 0 0 . . 0. �® 0. (: Infiltration 1,626 3,112 4,738 �// Whole House 11,983 3,112 21,095 ,439 ( 2 tons ) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences.