Loading...
HomeMy WebLinkAboutCompactionUES Project No: Workorder No: Report Date: 3310.2100336.0000 248252-1 10/18/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:John Wiliams UES Technician:Mark Rogers 2201 North 43rd Street Fort Pierce, FL 34946 Date Tested:10/12/2021 Project:CMT Williams Residence 2201 N 43rd St 2201 N 43rd Street, Fort Pierce, St Lucie County, FL 34946 Type of Test: Area Tested:2201 N 43rd Street, Fort Pierce Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northeast corner of lot 0-1 ft 103.3 12.3 102.7 12.0 99 Pass 2 Southwest corner of lot 0-1 ft 103.3 12.3 102.9 11.8 100 Pass 3 Center of lot 0-1 ft 103.3 12.3 103.4 12.3 100 Pass Remarks: Permit:SLC18110076 Reviewed By GFA International, Inc FBPE Registry No.4930 Alex Albandoz, P.E. STATE OF FLORIDA Professional Engineer No. 92555 This item has been digitally signed and sealed by Alex Albandoz, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1