Loading...
HomeMy WebLinkAboutProject Information JMJ L; L• U c-_L � z -- ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A A,B, D 1,2,3,4,5,6,7' Wood Shingles and A,B, D Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 �'. LUCIE 1VVORKS FILE COPY EVEWED, FOR a c� �:��IMP�IIMM�E- Sec ion tlG enera Informa ion) Master.Permit No. R0CCG Process No. XIC Contractors Name:a(5kV\_Q(:M I W(1V-- License#CCC I 'no"'- Job Address!w)?iaaK°f_ _VA u 4 ROOF CATEGORY ❑Low Slope ❑Meckhnically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles etal Panel/Shingles Mood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ew roof ❑ Repair ❑ Maintenance ❑ Reroofing ❑Recovering .ROOF SYSTEM INFORMATIO Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) d�o Total(SF) � Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow'drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. t� Section E(Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values are greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: -x -�-Mg: =M,, Product Approval M (Zone 2e: = x _ _)-Mg: =M2e Product Approval Mf (Zone 2n: x)L -Mg: =Mr,, Product Approval Mf (Zone 2r. x 1L = Mg: =M& Product Approval Mf (Zone 3e: x _ _)-Mg: =Mri. Product Approval Mf (Zone 3r: x)L _ M9' =M Product Approval Mf Method 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistance(Mr)From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based the systems •For Uplift based tile systems use Method 3.Compare the values for F'with the values for.Fr If the F'values are greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable. Method 3"Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= )-W:-cos r =Fri Product Approval F' (Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= )-W: cos r =Fr2" Product Approval F' (Zone 2r: x L =x W:= )-W: cos r =Fr2r Product Approval F' (Zone 3e: x! =x W:= )-W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:= )-W: cos r =Fr3r Product Approval F' Whereto Obtain Information Description Symbol Whereto find Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity M8 Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Me Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application. Section C(Low Slope Roof) Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for An Sheet Attachment: manufacturer Zone 1':_.._."oc @ Lap,#Rows—® "oc (If a component is not used,identify as"NA") Zone 1_._"oc @ Lap,#Rows ®=oc System Manufacturer: Zone 2_.._."oc @ Lap,#Rows_®H oc Zone 3_. :"oc @ Lap,#Rows "ac Product Approval No.: Number of Fasteners Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1'• Zone 1- Zone 2 Zone 3: Zone 1':_Zone 1: Zone 2:_Zone 3: Illustrate Components Noted and Details as Applicable: Max.Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping, Etc., Deck: Indicate: Mean Roof Height, Parapet Height,.Height of Base Type: Flashing,Component Material,Material'.Thickness,Fastener Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply with RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet&No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: FT. Insulation Base Layer: Base Insultation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: Top Insulation Size and Thickness: FT. Top Insulation Fastener/Bonding Material: Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bonding Material: Height Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: LUCIE WORKS ( .. ��sec✓ "� r�x ttefi'� 5 �.• i f,a 1 y,�{Er'�•a FILE COPY BOCC Section D (Steep Slope Roof System) Roof System Manufacturer: r, 1� ,` '5 cooly Notice of Acceptance Number: Minimum Design Wind Pressures,If Aq licable(FrO A,S 127 or Qdcul tions): Zone 1: Zone 2e:-Zone P " Zone 2razZone 3e� one 3r: Deck Type: ® � ' Type Underlayment Roo�ope: ,$$ 2 Insulation: -A Fire Barrier: Ridge Ventilation? Fastener Type&Spacing: /zaa Adhesive Type: Type Cap Sheet: Mean Roof Height: 10 I Roof Covering: Type&Size Drip 3 X3 Edge: Property Card 10/18/21 7:50 AM' f i - � i0 - Sketch Area Legend Sub Area Description Area Fin Area Perimeter _ .. APSA Aluminium Porch(Screen)Average.216 0 60 - BAS 'BASE AREA .-.',,1712' 1712 204 GAA Garage Attached Average •'440 0 84 PATA Patio Average(Plain Slab) 210 0 58 SPAA Screen Porch Attached Average 80 0 36 Special Features and Yard Items Type Qty Units Year Blt Driv-Concret 1 765 1994 Fen WoodSB 6' 1 160 1999 Current Year Values Current Values Breakdown 'Current Year Exemption Value Breakdot_vn - Building: $133,800 Tarc,Year Grant Year Code Description - Amount -• 2021 2002 .0500 Homestead Exemption S25;000 Land: S36,700 2021 2008 0550 Homestead Exemption over$50,000 so Just/Market: S170,500 AgCredit: $0 Save Our Homes or 10%Cap: $128,728 Assessed: $41,772 Exemption(s): $25,000 ' Taxable: 516,772 . Current Year Special Assessment Breakdown Start Year AssessCode Units Description - Amount 2009 2009 - 12 County Solid Waste — $276.14 This does not necessarily re resent the total Special Assessements that could be charged against this property.The total amount charged for special assessments is rcflected on the most current tax statement and information is available with the SLC Tax Collector's Office Historical Values Year JustAMarket Assesscd Exemptions Taxable ' 2021 $170.500 $41,772 $25,000 $16,772 2020 $150.700 $41.196 $25,000 $16,196 2019 $142,900 $40.270 $25,000 $15,270 2018 $133,900 $39,520 $25,000 $14.520 Permits Number Issue Date Description Amount Fee C94-01405 Mar 21,1994 Residenfial New Construction $91.696 $91,696 C05031314 Mar 21,2005 Roof $10,000 $0 Notice:This does not necessarily represent all the permits for(his property. Click the following link to check for additional permit data in Saint Lucie County All informationis believed to be correct at this time,but is subject to change and is provided without any warranty. https://www.pasic.gov/RECard/#/propCard/l756 Page 2 of 3 Property Card 10/18/21,7:50 AM r Michelle Franklin,CFA--Saint Lucie County Property Appraiser--All rights reserved. Property identification Site Address:7808 LAKELAND BLVD Use Type:0100 Secfrown/Range:02A4S/39E Account,#.:1756 Parcel ID:1301-607-0114-000-2 Map ID:13102N Jurisdiction:Saint Lucie County Zoning:RS-4 Count ' Ownership Scheryl Johnson 1'ru 7808 Lakeland BLVD - Fort Pierce,FL34951 �- r: ,;� 'A �� e Legal Description LAKEWOOD PARK-UNfT7-BLK74LOT7@tAP1310M(OR 1387-1563) eurrentvalues Just/Market Value: - $170,500 Assessed Value: S41,772 �'"?• A - t Exemptions: $25,000 Taxable Value: $16.772 Property taxes are subject to change upon change of ownership. Total Areas • Past taxes are not a reliable projection of thture taxes.-. Finished/Under Au(SF): 1,712 • The sale of a property will prompt the removal of all exemptions,assessment caps,and special classifications. Gross Sketched Area S 2,658 Land Size(acres): 0.27 Land Size(SF):. 11,700 Taxes for this parcel: SLC Tax Collector's Office 17 , DownloadTRIM for this parcel:Download PDF12 Building Design Wind Speed- Occupancy Category I II III R IV Speed 140,150 160 ' SOnrCealllnka: Sale History Date Book/Page Sale Code Deed Grantor Price Apr4,2001 1387/1563 XX01 SP- Bank Of America Nat'l Assoc $70,000 Jun 13,2000 1366/2835 XX01 SP .Woad Benjamin R $70,700 Feb 17,1999 121311709 XX01 WD NATIONSBANC MORTGAGE CORP - $71,000 Nov 25,1998 1186/2791 XX01 Cr Theresa L Brennan $100 Mar29,1995 0948/0722 XX00 WD Frank V Semfini - $82,000 Mar 1,1994 0997/1328 XX01 WD Silas F Rexrode $10,200 Jul 1,1988 059312855 =0 CV $8,000 Building Information(1 of 1) Finished Area:1,712 SF - - Gross Sketched Area:2,658 SF Exterior Data View: Roof Cover.Dim Shingle Roof Structure:Hip Building Type:HC Year Built:1994 Frame: Grade:C Effective Year.1994 Primary Wall:Wood/Sheath Story Height:I.Story No.Units:I Secondary Wall: Interior Data,. Bedrooms:3 Electric:MAXIMUM Primary Int Wall: Full Baths:2 Heat Type:FrcdHotAir Avg Hgt/Floor:0 Half Baths:0- Heat Fuel:ELEC Primary Floors:Carpet A/C%:100% Heated%a:100% Sprinkled%:N/A% https://www.pasic.gov/RECard/#/propCard/1756 Page 1 of 3