FILE Product ApP
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail f�
✓ Gy _
FL# FL33818-RI Zile
Application Type Revision R
Code Version 2020
Application Status Approved CODE; PUIANCE
To LUC��� � 14
Comments
Archived O G C
Product Manufacturer Gulf Coast Supply&Manufacturing, LLC.
Address/Phone/Email 4020 S.W.449th Street
Horseshoe Beach, FL 32648
(352),498-0778' Ext 0565
Jared.Pearce@gulfcoastsupply.com
Authorized Signature Jared Pearce
jared.pearce@gulfcoastsupply.com
Tech nical`Rep resentative
Address/Phone/Email
Quality Assurance Repre'seriiative
Address/Phone/Email,
Category Roofing
Subcategory Metal Roofing
Compliance Method... Evaluation Report from,a Florida Registered Architect or a Licensed Florida
Professional Engineer
[I Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Steven M. Urich, PE
- Chi Validation Checklist- Hardcopy Received
Certificate of Independence EL3381 RI COI GCS20002,1a 2020 FBC Eval Metal Roofing NonHVHZ
i a Pcff .
Referenced Standard and Year:(of Standard) °. Standard Year
ASTM B 117 2016
ASTM G 155 2013
FM 4471 1992
httpsi//www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtcpgflynXQVdmda12NiCFr3eBjf5nka1q%2bw5sQ9vG6mg%3d--3d`' Page'1 of 3
Florida Building Code Online 10/1,8/21,7:46 AM
S
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 1897 2012
UL"580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
PP P
Date Submitted 04 13 2021
Date Validated 04/15/2021
Date Pending FBC Approval 04/19/2021
Date Approved 06/09/2021
Summary of Products
FL# Model,Number or Name Description
33818.1 Metal Roofing Systems(HVHZ) GulfLok,VersaLoc, 5V Crimp, GulfPBR and GulfRib
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL33818—Rj 11 GCS20002.1b 2020 FBC Eval Metal Roofing.
Approved for use outside HVHZ: No HVHZ final.pff
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-164.25 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL33818 1 A GCS20002.1b 2620 FBC Eval Metal Roofing
HVHZ_final.pdf
Created by Independent Third Party: Yes
33818.2 Metal Roofing Systems(nonHVHZ) GulfLok,GulfSeam, Megal-oc,VersaLoc, 5V Crimp, GulfPBR,
GulfRib and GulfWave
Limits of Use Installation Instructions
Approved for use in HVHZ: No FI-33818 R1 RI GCS20002.1a 2020 FBC Eval Metal Roofing
Approved for use outside HVHZ:Yes NonLjVHZ final.pd
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-164.25 Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL33818 RI AE GCS20002.1a 2020 FBC Eval Metal Roofing
NonHVHZ final,pdf
Created by Independent Third Party: Yes
Contact Us i;2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 ,
The State of Florida is an AA/EEO employer.,copyright 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F,S.must provide the Department with an email address If they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public,To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:.
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtcpgflynXQVdmdal2NzCFr3eBjfSnkalq%2bw5sQgvG6mg%3d%3d... Page 2 of 3
Registry No. 29824
CREEK 17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION- EPORT FLORIDA BUILDING CODE,7T"EDITION(2020) -
Manufacturer;' GULF:COAsT;SUPPLY&MANUFACTURING, LLC . issued April 13, 2021
14429 SW 2"d Place, Suite G30
Newberry, FL,32669
(352)498-7852
www.gulfcoastsupr)[y.com
Manufacturing Locations: . Alachua, FL
Sebring, FL
Montgomery,.AL
`Quality Assurance: Keystone Certifications, Inc. (QUA1824)
SCOPE
Category: Roofing
'Subcategory: Metal Roofing
Code Edition: Florida Building Code,7th Edition(2020) High-Velocity Hurricane Zones(HVHZ)
Code Sections: 1518.9.1, 1523.1.1, 1523:6:5,-1523.6.5.2.4, 1523.6.5.2.4.1
Properties: Wind Resistance
REFERENCES
Enti Report No. - Standard Year
Architectural Testing, Inc.(TST1527)' B9000.01-450-18 TAS 125 2003
Farabaugh Engineering&Testing, Inc.(TST1654). T126-07 TAS 100 1995
Farabaugh Engineering&Testing,Inc.(TST1654) T128-07 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) T129-07 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) T130-07 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654Y T132-07 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) T215-08 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) T270-08. TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654)`. '' : T271-08 TAS 100 1995
Farabaugh Engineering&Testing,Inc.(TST1654) - : r_T272-08 TAS 100 1995
Farabaugh Engineering&Testing, Inc.(TST1654) , T273-08.. TAS 100. 1995
Farabaugh Engineering&Testing, Inc.(TST1654)._ . ' _ T356-10- TAS 100 1995
Force Engineering&Testing(TST5328)' 72-0313T-06A-C. TAS 125 2003
Force Engineering&Testing(TST5328) 72-0198T-07A-C TAS 125 2003
Force Engineering&Testing(TST5328) -` 1.17-0062T-07A-C TAS 125 2003
Force Engineering&Testing(TST5328) 117-0062T-07D-F TAS 125 2003
Force Engineering&Testing(TST5328) 117-0062T-07G-1 TAS 125 2003
Force Engineering&Testing(TST5328) 117-0062T-07J-L TAS 125 2003
Force Engineering&Testing(TST5328) 117-0065T-07A-C TAS 125 2003
Force Engineering&Testing(TST5328) .117-0238T-09D. FM 4471 1992
Force Engineering&Testing(TST5328) 117-0238T-09E FM 4471 1992
Force Engineering&Testing(TST5328) 1.17-0238T-11A FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-11A -• FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-11 B' FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-11 C FM 4471 1992
PRI Construction Materials Technologies(TST5878) HTL-018-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878). 1272T0002 ASTM B 117 2016
TAS 110 2000
PRI Construction Materials Technologies(TST5878) .1272T0003 -- ASTM B 117 2016
TAS 110 2000
PRI Construction Materials Technologies(TST5878) 1272T0005 ASTM G 155 2013
TAS 110 2000
PRI Construction Materials Technologies(TST5878) 1272T0006 ASTM G 155 2013
TAS 110 2000
GCS20002.1b FL33818-R1 Page 1 of.4
This evaluation'repoit.is provided for State of Florida"product approval under,Rule,61 G20-3. ..The Manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance.changes throughout the.duration for which this report is valid.
This evaluation;report does.not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C� CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing(HVH2)
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
GulfLok Profile: 1 in. snap lock seam; Max.16 in. coverage
Description: Non-structural, snap lock standing seam roof panel with 718 in. slotted nail strip:
Material: Min. 26 ga.ASTM A792 AZ50 coated with Florupon@ or ASTM A653 G90;
F = min. 50 ksi; Shall conform with FBC Section 1507.4.3
1 � - -
12"and 16" Coverage
VersaLoc Profile: 1.5 in. mechanical seam; Max. 18 in. coverage
Description: Non-structural, mechanical lock 180e standing seam roof panel
Material: Min. 24 ga.ASTM A792 AZ50 coated with Florupon@ or ASTM A653 G90;
F = min: 50 ksi; Shall.conform with FBC-Section 1507.4.3
11./2.
W.is-coverage
5V Crimp Profile: 7/16 in. ribs at 12 in. o.c.; 24 in. coverage
Description: Non-structural,through fastened roof panel
Material: Min. 26 ga.ASTM A792 AZ50 coated with Florupon@ or ASTM A653 G90; '
Fy= min. 50 ksi; Shall conform with FBC Section 1507.4.3
Min. 0.032 in.ASTM B209, 3105 H24 aluminum; Optional Florupon@ paint finish;
Fy= min. 25 ksi; Shall conform with FBC Section 1507.4.3
12"
24" Coverage
GCS20002.1 b FL33818-RI Page 2 of 4
This evaluation report is provided for State of Florida,product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes'or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
Y GULF COAST SUPPLY&MANUFACTURING,.LLC
:> CREEK; Metal Roofing(HVH2)"
TECHNICAL SERVICES, LLC
GuIfPBR Profile: 1 1/4 in, ribs at 12 in. o.c.; 36 in. coverage -
Description Non-structural,through fastened roof panel
Material: Min.26 ga.ASTM A792-AZ50-.coated.with�Floruoon®:orASTM A653'.G90;
F, =min::80,ksi;.Shall conform with FBC Section,1507:4:3
111410t 2n
36"Coverage
GulfRib' Profile: 3/4 in. ribs at 9 in. o.c.;36 in. covers e
Description: Non-structural,through;fastened-roof panel.:';
Material: Min.29 ga;'ASTM A792 AZ50 coated'with Florupon®or.ASTM A653 G90;
F =min. 80 ksi; Shall conform with FBC Section 1507.4.3
3/4" g„
v
36" Coverage
GCS20002.1b FL33818-Rt Page 3 of 4
This evaluation report,is" id ed,'for:State.of-Florida product approval under Rule 61'G20-3. The rnanufactu�er shall notify CREEK
Technical Services, LLC of-any,product.changes or quality assurance changes through"out.the duration for_which this report-is valid.
This evaluation:report does note_xpress nor imply warranty, installation, recommended use,-or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY&MANUFACTURING, LLCCREEK .
Metal Roofing(HVHZ)
TECHNICAL SERVICES, LLC
LIMITATIONS
1. Fire classification is,not withimthe'scope.of this evaluation:
2. The roof deck and the.roof deck attachment-information are provided based on testing. FBC requirements
for the rational design of the roof deck, including the attachment, are not within the scope of this
evaluation.
3. Roof slope shall be 2:12 or greater.
4. Reroofing shall be in accordance with Section 1521.
5. Installation of the evaluated products shall comply with this report, RAS 133, and the ,manufacturer's `
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
6. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
.The products evaluated herein by Zachary.R.:Priest, P.E..have demonstrated compliance with the Florida Building
:Code, 7t' Edition (2020)High-Velocity Hurricane Zones(HVHZ).as evidenced in the referenced documents submitted
by the named manufacturer..
`oG ptY,R, p9��i,�� This item has been
8•. Fs digitally signed and
ti. F� '• sealed by Zachary R.
No 74021 - Priest, PE,on 4/13/2021.
' Printed copies of this
7t —
o document are not
STATE, OF : 14 considered signed and
O •. sealed and the signature
T •.� P =o` g Zachary R. Priest, P.E.
R 1'�.��o`,` electronicco must be 1ees.n any Florida Registration No. 74021
p Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A—Installation(3 pages)
2) APPENDIX B—Approved Roof Systems(4 pages)
3) APPENDIX C—Design Wind Loads(3 pages)
GCS20002.1b _ _ FL33818-R1 Page 4 of 4
This evaluation report is"provided for State of"Florida product approval under Rule61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, orother product attributes that'are not
specifically addressed herein.
CREEK- GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing(HVHZ)
TECHNICAL SERVICES, LLC
APPENDIX A
INSTALLATION
Note-Refer to the APPRoigo RooFSYsreMssection of this report for specific installation details of a selected system. -
Unless otherwise specified in.this report,the following installation details shall be met for the named products:
Component Product Installation Detail
#9-15 HWH wood screw
with sealing washer
#9-15 HWH WoodZAC
screw Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion
#10-12 Pancake Type A --resistant in accordance with FBC section 1507.4.4.
Fasteners screw
#12-11 Pancake Type A
screw
1/4-14 HWH ZAC Impax Installed at panel side lap;Shall be corrosion resistant in accordance with FBC
Lap screw section 1507.4.4:
24 ga.in-seam clip
1%
-T
GulfLok'Clip
14i4'
Clips
0.76
[71 _ - H - 4-1/4"
2"
NC-3300373 Sliding Clip
1/2"
TiteBond Weathermaster.
Sealants Metal Roof Sealant Shall be applied in 1/4"=5/16"continuous beads on the male rib along the seam
GCS20002.1b FL33818-Rl Page 1 of 3
This evaluation report is provided for State of Florida-product approval under Rule,61.G20-3. -The manufacturer shall notify CREEK
Technical,Services' LLC of any product changes or quality assurance changes throughout the duration for which this report,is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes:that,are not
specifically addressed herein.
C CREEKGULF COAST SUPPLY&MANUFACTURING, LLC-
Metal Roofing(HVHZ).
TECHNICAL SERVICES, LLC APPENDIX A
Fastening Details
Nomenclature Attachment ,
MAX. 16" COVERAGE
GulfLok Type 1
(1) #10-12 X 1"'TYPE A PANCAKE
Gullok'" CLIP 24 GA.
GulfLok Type 2
(1) #10-12 X 1"TYPE A PANCAKE
Max. 18"
VersaLoc Type 1 —Icv
T
\-1500SC SLIDING CLIP
(2)#12-11 x 1"Panhead per Clip
(1) #9-15 x 1-1/2" HWH w/Sealing Washer
5V Type 1
12" 12"
At Panel Lap
At Panel Lap
#1/4-14 x 7/8"Lap Screw @ 24"O.C. Max.
12" 1211 12"
GWIPBR Type 1
(1) #9-15 x 1-1/2"
GCS20002.1 b 171-33a18-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes'or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
�R=g � GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing(HVHZ(
TECHNICAL SERVICES,LLC
APPENDIX A
Fastening Details
Nomenclature Attachment;
#1/4-14 x 7/8"Lap Screw @ 24'.'O.C.-Max
5n 7a 5u- 7u 5n 7u �u
GultPBR Type.2
(i) #9-15 x 1-1/2",
i At Panel Lap
GuIfRlb Type 1 '
�-(1)#9-15 x 1-1/2"w/Sealer Washer
_ �6.5"�2.5" 6.5" 2.5" , 6:5" 2.5".. 6.5"
Gulfft Type 2
-(1)#9-15 x 1-1/2"w/Sealer Washer
GCS20002.1 b FL33818-Rl Page 3 of 3
This"evaluation report is provided-for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing(HVH2)
TECHNICAL SERVICES, LLC ..
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1523.4.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system.
5. Underlayment shall be installed in accordance with FBC requirements. The minimum underlayment shall be ASTM D 226, Type II installed as described
in FBC Section 1518.2.1 with nails and tin caps per 1517.5.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(Fy=min.40 ksi)Wide Rib Deck(Type WR)
conforming to ANSI/SDI-RD1.0&FBC. In no case shall the panels be installed on less than two continuous spans,which are spaced a maximum 5-ft o.c.
At minimum,the deck shall be attached with one(1)#12 x 1.5-inch HWH self-drilling screws at the bottom of each flute(maximum. 6-inch o.c. along the
support). At minimum,the deck side laps shall be fastened a maximum 6-inch o.c.with#12 x 1.5-inch HWH self-drilling screws.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 19/32-inch thick APA Span-Rated plywood
sheathing or wood plank at maximum 24-inch span for new construction. Existing construction shall be the minimum plywood sheathing or wood.plank
thickness at maximum 24-inch span as stated in the approval tables on following pages. In no case shall the attachment be less than 8d ring shank nails
spaced 6-inch o.c.
Roof System Numbers and Definitions
LOK-W# GulfLok over Wood Deck New or Existing)
VL-W# 1.5"VersaLoc over Wood Deck new or Existing)
5V-W_# 5V Crimp over Wood Deck New or Existing)
PBR-W# GulfPBR over Wood Deck New or Existing)
RIB-W# GulfRib over Wood Deck New or Existing)
Approved Systems for GulfLok over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
OPTIONAL
Min.15/32 26 ga.,Grade 80 Gulf-ok Guff-ok Type 1 attachment #10-12 x 1"
LOK-W-1 Approvedfire barrier As required per FBC -63.5
B-C plywood Max.16 inch coverage Pancake Type A screws spaced 5 3/16 in.o.c
or insulation
OPTIONAL GUIfLok Type 1 attachment with#10-12 x 1"
Min.15/32 Min.26 ga.Gulf-ok Pancake Type A screws spaced 5-3116 in.o.c.
LOK-W-2 Approved fire barrier As required per FBC -121.75
CDX plywood Max.16-inch coverage Titebond Weathermaster Metal Roof Sealant
or insulation applied to male rib.
OPTIONAL Gu/fLok Type 2 attachment with
LOK-W-3 Min.plywood
Approved fire barrier As required per FBC' 26 ga.,_ -inchrade o Guge #10-12 x 1"Pancake Type A screws through 461
B-C I ood Max.16 inch coverage p� or insulation g clip and spaced 5-3116 in.o.c.
GCS20002.1 b FL33818-Rl
� Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or"other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing(HVHZ)
TECHNICAL:SERVICES, LLC - APPENDIX B
Approved Systems for VersaLoc over Wood Deck(New or Existing)
System Deck. ,- _ _ .- .Fire Barrier, _ _ Underla ment_-, , , Roof Panel" Panel Attachment MDP
Y . P
OPTIONAL
Min. 15/32 Min.24.ga..VersaLoc VersaLoc Type 1 attachment
VL-W 1 B-C plywood ' Approved fire.barrier As required per FBC. Max.16-inch coverage., with clips spaced 24 in.o.c.- -59.75
or insulation
OPTIONAL
Min.15/32 Min.24 ga.VersaLoc VersaLoc Type 1 attachment
VL-W 2 B-C plywood Approved fire barrier As required per FBC . Max.16 inch coverage with clips spaced 6 in.o.c.- -123.5
or insulation
Approved Systems for 5V Crimp over Wood Deck(New or Existing)
System Fire Barrier/ MDP
Deck Underlayment Roof Panel . ,Panel Attachment
No. Insulation : (Psfl
OPTIONAL
Min.15/32- Min.26 ga.5V Crimp 5V Crimp Type 1 attachment with#9-15 HWH wood
5V-W1 B-C plywood Approved fire barrier As required per FBC 24-inch coverage screws with sealing washers spaced 12 in.o.c. -1l)8:5
or insulation .
'OPTIONAL
Min.15/32 B `'Min.26 ga.SV Crimp 5V Crimp Type 1 attachment with#9 15 HWH wood
W2 B-C plywood Approved fire barrier. As required per FBC 24-inch coverage, screws with sealing washers spaced 6 in.o.c. -156.5
or insulation - _ _
-.-Approved.8 stems,for.GuIfPBR over Wood Deck New or Existin
System Deck.' Insulation
Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No.
OPTIONAL GWIPB W R Type 1 attachment with#9-515 HWH WoodZAC
Min.15/32 Min.26 ga.GulfPBR . . . . .screws spaced 24 in.o.c.
PBR-W-1 g-C plywood Approved fire barrier As required per,FBC or insulation 36-inch coverage Laps fastened.with 1/4-14 x 7/8"-HWH.ZAC Impax Lap 60.5
screws spaced 24 in.o.c:
GCS20002.1 b - FL33818-R1 ..Page 2 of 4.
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing(HVHZ)
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for GulfPBR over'Wood Deck(New or Existing)
System Fire Barrier/ MDP
No. Deck Insulation Underlayment Roof Panel Panel Attachment (psf)
Min. 1x4 No.2
SYP wood GultPBR Type I-attachment with#9-15 HWH WoodZAC
pur4 i spaced OPTIONAL' Min.26 ga.GulfPBR screws spaced,24 in.o.c.into wood purlins
PBR-W-2 24 in.o.c." .Approved fire barrier As required per FBC 400.5
over or insulation 36-inch coverage Laps fastened with 1/4-14 x 718 ZAC Impax Lap screws
-
spaced 24 in.o.c.
Min.15132.
B-C plywood
Min.1x4 No.2
SYP wood
purlins spaced OPTIONAL GuIfPBR Type 2 attachment with#9-1515 HWH
p P Min.26 ga.GuIfPBR WoodZAC screws spaced 12 in.o.c.into wood purlins
PBR-W-3 12 in-o.c. Approved fire barrier As required per FBC - `461.76
over or insulation 36-inch coverage Laps fastenedwi4h 1/414 x 7/8"HWH ZAC Impax Lap
Min.15f32
screws spaced 24 in.o.c.
. . . . . - .
B-C plywood
OPTIONAL GulfPBR Type 2 attachment with#9-15 HWH WoodZAC
Min.15/32 Min.26 ga.GulfPBR screws spaced 12 in.o.c.
PBR W 4 B-C plywood App or insulation roved fire barrier As required per FBC 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax Lap -154.75
-
J screws spaced 24 in.o.c.
Approved Systems for GulfRib over Wood Deck(New or Existing)
System Fire.Barrier/ MDP
Deck. Underlayment Roof.Panel, , Panel Attachment,
No._ Insulation. (psf)
Min.15/32 OPTIONAL Min.29 ga:GulfRib GulfRib Type 9 attachment with#with#9-15 HWH •
RIB-W-1 B-C plywood approved fire barrier As required per�FBC 36-inch coverage WoodZAC screws spaced 24 in.o.c -71.75
or insulation
Min.1x4 No.Z
SYP wood
purlins spaced OPTIONAL Min.26 ga.GulfRib GulfRib Type 9 attachment with#9-15 HWH WoodZAC
RIB-W-2 24 in.o.c. Approvedfire barrier As required per FBC 406.75
over or insulation 36-inch coverage screws spaced 24 in.o.c.into wood purlins -
Min.15/32
B-C plywood
GCS20002.1 b FL33818-R1: Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other -
product attributes that are not specifically addressed herein.
CREEK , GULF COAST SUPPLY&MANUFACTURING, LLC,
MetalRoofing(HVHZ)
c i
. . L SERvicEsL.L.,- G ..
: : . E : APPENDIX B
Approved Systems for GulfRib over Wood Deck(New or Existing) V
System Fire Barrier/ MDP
Deck Underiaymerit Roof Panel. Panel Attachment
No. Insulation (psf)
OPTIONAL
Min.15/32 . Min.26 ga.GulfRib GulfRib Type2 attachment with#9-15 HWH WoodZAC
RIB-W-3 B-C plywood Approved fire barrier As required per FBC 36 inch coverage screws spaced 12 in.o.c. 459.25
or insulation
Min.1x4 No.,2
SYP wood
purlins spaced OPTIONAL Min.26 ga.GulfRib GufffWb Type 1 attachment with#9-15 HWH WoodZAC
RIB-W-4 12 in.o.c. Approved fire barrier As required per FBC 464.25
over or insulation 36-inch coverage screws spaced 12 in.o.c.into wood purlins
Min. 15132
B-C plywood
6C820002.1 b . . FL33818-Rl Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3_ The manufacturer shall notify CREEK Technical Services,LLC of any product changes.or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
GULF COAST SUPPLY&MANUFACTURING, LLC
CREEKMetal Roofing(HVHZ)
TECIitV cAL SERVICES;LLC'
APPENDIX.0
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1620 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1620 of the FBC.
2. Exposure C and D shall be as defined in section 1620 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd=0.85
8. Design wind loads are calculated using Pasd=0.6P„it.
9. Zone 2 is inclusive of Zone 2e,Zone 2n,and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1,2, and 3 shall be defined as shown below. Dimension"a°shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever
is smaller, but not less than either 4%of the least horizontal dimension or 3ft
Gable Hip
a
3 2 3 13 2 3 a 3 2 30 a
2 1 2 2 1 2 2 1 2 2 1 2
1 _
3 2 13 131 2 3 a 3 2 %3J a
GCS20002.1b- :_.. . .FL33818-R1._,- Page.1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product-changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING, LLC
Metal Roofing(HVHZ) -
TECHNICAL SERVICEs, LLC y
APPENDIX C.
Gable/Hip Roofs in Ex sure C in Miami-Dade&Broward Count Roof slopes between 2:12 and 12:12
Basic Wind S eed m h
Mean Roof
Building Type. :Zone Risk Cat I Risk Cat I` Risk Cat II Risk Cat II Risk Cat III IV Risk Cat III IV
_Height(ft)
156 -165 170 77 175-;_ :-"180- 186
.20 -62.3 -69.7 -74.0 -78.5 183.0 :-88.6 -
25 -65.1 -72.8 -77.3 -81.9 -86.7 -92.6
30 -67.9 -75.9 -80.6 -85.4 - -90.4 -96.5
1 40 -72.0 -W6 85.6 -907 -95.9 =1+02.4
50 -75.5 =84.5 -89.7 -95.0 A 00.5. 107•.3
60 78.3 -87.6` -93.0 -98:5 -104:2 -111 c3
20 -90.9 -101.7 108.0 -114.4 -121.1 -129.3
25 -95.0 -106.3 ,112.8 -119.5 -126.5 -135.0
Enclosed/ 30 -99.0 -110.8 -117.15 -124.6 131.8 -140.8
Partially Open 2 40 -105.1 -117.6 -124.8 -132.2 .139.9 - - -149A
50 -110.1 -123.2 -130:8 -138.6 -146.6. -156.6
60 -114.2 :1127.7 135.6 -143.7' A52.0 - -162.3
20 -108.1 -120.9 -128.4 -136.0 7143.9 7153.7
25 -112.9 -126.3 134.I -142.1 -.150:3 -160.5
3 30 -117.7 -131.7 -139.8 148.1 -156.7 -167.3
:40 -124.9 -139.7 -148.3 -157.2 -166.3 -17T6
50 -130.9. -146.5 -155:5 _._ =164.7 -174.3 =186.1
60 -135.7 7151.8 161:2 A 70.8 -180.7 -192.9
20 - -72.9 - -81.6 -86.6 -_-91.8 -97.1 -103.7
25 =76.2 -85.2 -90.4 -95.8 -161.4 -108:3
30 -79.4 -88.8 -94.3 -99.9 -105.7 -112.9
1 -40 -84.3 -94.3 -100>1 -106:0 -112.2 -119.8
50 -88.3 -98.8' -104.9 -111 i 1' -117.6 -125.5
60 =91.6 -102.4 -108.7 -115.2 -121.9 -130.2
20 -101.5 -113.6 -120.6 -127.8 -135.2 1144:3
25 -106.0 118.6 -125.9 -133.4 141.2 150.7
Partially 30 -110.5 -123.7 - =131.3 -139..1 -147.2 -157:1 T-
Enclosed 2 40 -117.3 -181.2 -139.3 -147.6 -156.2 -166.8
50- -123.0 -137.5 -146.0- -154.7 -163.7 -174.9
60 -127:5 -142.6 -151.4 -160.4 -169.7 -181.2-
20 -118.7 -132.8 -140.9 -149.3 -158.0 -168.7
25 -124.0 -138.7 -147.2 -156.0 -165.0 -176.2
. ._
30 -129.2 144.6 -153.5 -162.6 -172.0 -189.7
3..
40 -137.1 -153A -162.9 _-172.6 182.6 -195.0
`50 -143.7• -160.8 -170.7 -180.9 191.4 -204.3
60 -149.0 -166.7 -177.0 -187.5 -198.4 -211.8
GCS20002.1 b FL33818-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
C_• CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing(HVHZ)
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hi Roofs in Ex sure Din Miami-Dade&Broward Count Roof slopes between 2:12 and 12:12
Basic Wind Speed(mph)
Building Type Zone Mean Roof Risk Cat I Risk Cat I Risk Cat II Risk Cat II Risk Cat III,IV Risk Cat III,IV
Height(ft) 156 165 170 175 180 186
20 -74.8 -83.7 -88.8 -94.1 -99.6 -106.3
25 -77.6 -86.8 -92.1 -97.6 -103.3 -110.3
1 30 -80.4 -89.9 -95.4 -101.1 -107.0 -114.2
40 -84.5 -94.5 -100.4 -106.3. -112.5 -120.1
50 -88.0 "-98.4 -104.5 -110.7 -117.1 -125.1
60 -90.7 -101.5 -107.8 -114.2 120.8' -129.0
20 -109.1 -122.1 -129.6 -137.3 -145.3 -155.1
25 -113.2 -126.6 -134.4 142.4. -150.7 -160.9.
Enclosed/ 30 -117.2 -131.1 -139.2 -147.5 -156.0 -166.6
Partially Open 2 40 -123.3 -137.9 -146.4 -155.1 -164.1 -175.2
50 -128.3 -143.6 -152.4 -161.5 -170.8 -182.4
60 -132.4 -148.1 -157:2 -166.6 -176.2 -188:2
20 -129.7 =145.1 -154.0 -163.2 -172.7 -184.4
25 -134.5 -150.5 -159.7 -169.3 -179.1 -191.2
3 30 -139.3 -155.9 -165.4 -175.3 -185.5 -198.1
40 -146.5 -163.9 -174.0 -184.4 -195.1 -208.3
50 -152.5 -170.6 -181.1 -192.0 -203.1 -216.8
60 -157.3 -176.0 -186.8 -198.0 -209.5 -223.7
20 -87.5 -97.9 -103.9 -110.1 -116.5 -124.4
25 -90.7 -101.5 -107.8 -114.2 -120.8 -129.0
1 30 -94.0 -105.1 -111.6 -118.3 -125.1 -133.6
40 -98.8 -110.6 -117.4 -124.4 -131.6 -140.5
50 -102.9 -115:1 -122.2 -129.5 -137.0 -146.3
60 -106.1 -118.7 -126.0 -133.6 -141.3 -150.9
20 -121.8 -136.3 -144.7 -153.3 -162.2 -173.2
25 -126.3 -141.3 -150.0 -159.0 -168.2 -179.6
Partially 2 30 -130.8 -146.4 -155.4 -164.7 -174.2 -186.0
Enclosed 40 -137.6 -154.0 -163.4 -173.2 -183.2 -195.6
50 -143.3 -160.3 -170.1 -180.3 -190.7 -203.6
60 -147.8 -165.3 -175.5 -186.0 -196.7 -210.1
20 -142.4 -159.3 -169.1 -179.2 -189.6 -202.5
25 -147.7 -165.2 -175.4 -185.8 =196.6 -210.0
3 30 -153.0 -171.1 -181.6 -192.5 -203.6 -217.4
40 -160.9 -180.0 -191.0 -202.4 -214.2 -228.7
50 -167.5 -187.3 -198.9 -210.7 -223.0 -238.1
60 -172.7 -193.2 -205.1 -217.4 -230.0 -245.6
GCS20002.1 b FL33818-R1 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other
product attributes that are not specifically addressed herein.