Loading...
HomeMy WebLinkAboutREV ENERGY CALCS COMMENTS10/6/21, 8:15 AM Gmail - Energy Calcs - Building Deparment Comments https://mail.google.com/mail/u/0?ik=cf5c83400c&view=pt&search=all&permmsgid=msg-f%3A1710813940734222452&simpl=msg-f%3A17108139407…1/2 G.M. Worley, Inc. <gmworleyinc@gmail.com> Energy Calcs - Building Deparment Comments Mike Thornton <Mike_Thornton@smithservices.org>Mon, Sep 13, 2021 at 2:55 PM To: "G.M. Worley, Inc." <gmworleyinc@gmail.com> Cc: Bill Skopelja <wgskopelja44@comcast.net> HI MYRANDA…ENCLOSED ARE REVISED CALCULATIONS. I HOPE THAT MY RESPONSE BELOW WILL HELP CLEAR UP ANY CONFUSION. From: G.M. Worley, Inc. [mailto:gmworleyinc@gmail.com] Sent: Thursday, September 09, 2021 2:51 PM To: Mike Thornton Subject: Energy Calcs - Building Deparment Comments Good afternoon Mike, This is in regards to the William and Regina Skopelja project: Would you mind taking a look at your energy calcs to make sure we don't have an error somewhere? Below is the comment I got from the St. Lucie Building Department. PLEASE CLARIFY; CEILING R = 20.0 FOAM R20 IS CORRECT. THE CEILING AND THE ROOF ARE ACTUALLY ONE ASSEMBLY. AND WALL R = 19.0 ON TYPICAL WALL SECTION ON SHEET A-4 THE EXTERIOR CBS WALL IS AT LEAST R-9 CORE-FIL FOAM w/R-4 INSULATION BOARD; R-19 IS ONLY A SMALL SECTION OF THE EXTERIOR WALL, THEREFORE, I HAVE TO CALCULATION WITH THE LESSER R-VALUE, NOT WITH THE GREATER VALUE OF R-19. VS. CEILING R = 1.0 IN THIS CASE, BECAUSE THE CEILING IS SOMEWHAT 10/6/21, 8:15 AM Gmail - Energy Calcs - Building Deparment Comments https://mail.google.com/mail/u/0?ik=cf5c83400c&view=pt&search=all&permmsgid=msg-f%3A1710813940734222452&simpl=msg-f%3A17108139407…2/2 UNCONVENTIONAL FOR A RESIDENCE, THE ROOF IS ACTUALLY THE CEILING. SO, I HAVE TO ENTER AT LEAST ONE COMPONENT ON THE “CEILING” SCREEN IN MY CALCULATIONS, USING R-1, SO THAT IT WOULD QUALIFY AS A “STRUCTURE”. AND CBS R = 9.0 ON PAGE 1 OF 5 OF THE ENERGY CALCULATIONS. I HAD TO CHANGE THE DESIGNATION OF THE CBS WALL. THE NEW INPUT IS “POLYSTYRENE BEAD AGGREGATE-EXTERIOR”. IF THERE WAS NOT ANY 3/4" INSULATION BOARD, IT WOULD ONLY SHOW UP AS R-0 FOR THE EXTERIOR WALL. THE PROGRAM AUTOMATICALLY TAKES INTO ACCOUNT THE MINIMUM R-VALUE OF THE POLYSTYRENE BEAD AGGREGATE, SO IT ONLY WANTS US TO SHOW THE R-VALUE OF THE INSULATION BOARD, WHICH IS R-4. (I HAVE ENCLOSED AN EXPLANATION OF THIS. IT IS CALLED “CURRENT WALL”, FROM THE HELP SECTION OF MY CALCULATIONS. I HIGHLIGHTED IT FOR YOU). THE NUMBERS THAT ARE ENTERED ON 10a OF PAGE 1 of 5, SPELL OUT “POLYSTYRENE BEAD AGGREGATE-EXTERIOR”, BUT, THEY INTERFERE WITH THE R-4.0 RATING OF THE ¾” INSULATION BOARD. (THE FLORIDA SOLAR ENERGY CENTER IN COCOA SAID YOU ARE WELCOME TO CALL THEIR TECH SUPPORT TEAM TO VALIDATE MY CLAIMS. I HAVE BEEN IN CONTACT WITH JEFF M. ABOUT THIS. THEIR PHONE NUMBER IS: (321) 323-7255 [Quoted text hidden] 1627_001.pdf 652K