HomeMy WebLinkAboutREV ENERGY CALCSFORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification (usually four pages/may be greater)
❑ Energy Performance Level (EPL) Display Card (one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements (five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page)
❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
2020 Duct Leakage Test Report - Performance Method (usually one page)
9/13/2021 1:16:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Skopelja
Builder Name: G.M. Worley, Inc.
Street: Southwind Trail
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner: William Skopelja
Jurisdiction:
Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT
County: Indian River(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wail Types(3798.1 sqft.) Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead dega8Y,,9M&if*
ft2
b. NIA R=
3. Number of units, if multiple family 1
c. N/A R= ft2
4. Number of Bedrooms 1
d. N/A R= ft2
No
11. Ceiling Types(1696.7 sqft.) Insulation Area
5. Is this a worst case?
a. Cathedral/Single Assembly (Unventdld�11.0 1696.70 ft2
6. Conditioned floor area above grade (ft2) 1697
b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A R= ft2
7. Windows(362.6 sgft.) Description Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Dbl, U=0.35 362.65 ft2
a.
SHGC: SHGC=0.20
b•
b. U-Factor: N/A ft2
SHGC:
C.
13. Cooling Systems kBtu/hr Efficiency
c. U-Factor: N/A ft2
a. Central Unit 28.4 SEER:19.00
SHGC:
Area Weighted Average Overhang Depth: 8.294 ft
Area Weighted Average SHGC: 0.200
14. Heating Systems kBtu/hr Efficiency
8. Skylights Description Area
a. Electric Heat Pump 28.6 HSPF:10.60
U-Factor:(AVG) N/A N/A ft2
SHGC(AVG): N/A
15. Hot Water Systems
9. Floor Types Insulation Area
a. Electric Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R= 0.0 1696.70 ft2
UEF: 1.260
b. N/A R= ft2
b. Conservation features
c. N/A R= ft2
None
16. Credits CF, Pstat
Glass/Floor Area: 0.214 Total Proposed Modified Loads: 43.80
PASS
Total Baseline
Loads: 74.49
I hereby certify that the plans and specifications covered by
Review of the plans and SHE S7',gT
this calculation are in compliance with the Florida Energy
specifications covered by this 0 _ - t
'
Code.
calculation indicates compliance rf, ,
with the Florida Energy Code.
i`""r
PREPARED BY:
Before construction is completed r
^�3'Z
this building will be inspected for Cd _
DATE:
compliance with Section 553.908 a
Florida Statutes.
I hereby certify that this building, as designed, is in compliance
tspn W
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Proposed Qn of NAN exceeds the performance method default limit of 0.08
and therefore does not require duct testing. R405 .2.3
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
requires a PERFORMANCE
9/13/2021 1:16:21 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Title:
Skopelja
Building Type:
User
Owner:
William Skopelja
Builder Name:
G.M. Worley, Inc.
Permit Office:
Jurisdiction:
Family Type:
Detached
New/Existing:
New (From Plans)
Year Construct:
Comment:
PROJECT
Bedrooms:
1
Conditioned Area:
1697
Total Stories:
1
Worst Case:
No
Rotate Angle:
0
Cross Ventilation:
Whole House Fan:
Terrain:
Flat Terrain
Shielding:
Light shielding
CLIMATE
Design Design Temp
1/ Location Tmy Site 97.5% 2.5%
_ FL, VERO_BEACH_MUNICIP FL_VERO_BEACH_MUNICIPA 45 90
BLOCKS
Number Name Area Volume
1 Block1 1696.74902343714272.130859375
Number Name
S1
# Floor Type
1 Slab -On -Grade Edge Ins
f # Type
1 Hip
# Type
1 Full cathedral ceiling
Address type:
Street Address
Lot #:
---
Block/SubDivision:
---
PlatBook:
Street:
Southwind Trail
County:
Indian River
City, State, Zip:
Fort Pierce,
FL, 34951
Int Design Temp Heating Design Daily temp
Winter Summer Degree Days Moisture Range
70 75 299 64 Medium
SPACES
Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
1696.74902328282.1305201953 Yes 2 1 Yes Yes Yes
FLOORS (Total Exposed Area = 1697 sq.ft.)
Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
S1 266 0 1696.749 ft 0.710 1.00 0.00 0.00
Materials
Metal
f # Ceiling Type
_ 1 Cathedral/Single Assembly(Unvented)
Ventilation
Unvented
ROOF
Roof Gable
Roof
Rad Solar SA Emitt Emitt
Deck Pitch
Area Area
Color
Barr Absor. Tested Tested
Insul. (deg)
1897 ftz 0 ftZ
Medium
N 0.3 No 0.9 No
20 26.57
ATTIC
Vent Ratio (1
in) Area RBS IRCC
0
1696.749 ftZ N N
CEILING
(Total Exposed Area = 1697 sq.ft.)
Space R-Value
Ins. Type
Area U-Factor Framing Frac.
Truss Type
S1 1.0
Blown
1696.7ft2 0.047 0.11
Wood
9/13/2021 1:16:21 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
(Total Exposed Area = 3798 sq.ft.)
Adjacent
Cavity
Width
Height Area U-
Sheath Frm,
Solar Below
V# Ornt
To
Wall Type
Space
R-Value
Ft
In
Ft In sq.ft. Factor
R-Value Frac.
Absor. Grade
1 NE
Exterior
Conc Blk - Poly
S1
4.0
17.0
0
23.0 0 391.0 0.104
0 0
0.30 0 %
�_ 2 NW
Exterior
Conc Blk - Poly
S1
4.0
17.0
0
23.0 0 391.0 0.104
0 0
0.30 0 %
3 SW
Exterior
Conc Blk - Poly
S1
4.0
17.0
0
23.0 0 391.0 0.104
0 0
0.30 0 %
_
4 SE
Exterior
Conc Blk - Poly
S1
4.0
17.0
0
23.0 0 391.0 0.104
0 0
0.30 0 %
_
5 NE
Exterior
Conc Blk - Poly
S1
4.0
17.0
0
8.0 0 136.0 0.104
0 0
0.30 0 %
_
6 SW
Exterior
Conc Blk - Poly
S1
4.0
17.0
0
8.0 0 136.0 0.104
0 0
0.30 0 %
_
7 NW
Exterior
Conc Blk - Poly
S1
4.0
34.0
0
12.0 0 408.0 0.104
0 0
0.30 0 %
8 NE
Exterior
Conc Blk - Poly
S1
4.0
14.0
0
12.0 0 168.0 0.104
0 0
0.30 0 %
- 9 SW
Exterior
Conc Blk - Poly
S1
4.0
14.0
0
12.0 0 168.0 0.104
0 0
0.30 0 %
- 10 SE
Exterior
Conc Blk - Poly
S1
4.0
16.2
0
12.0 0 194.0 0.104
0 0
0.30 0 %
11 SW
Exterior
Conc Blk - Poly
S1
4.0
18.0
0
12.0 0 216.0 0.104
0 0
0.30 0 %
_
12 SE
Exterior
Conc Blk - Poly
S1
4.0
17.7
0
12.0 0 212.0 0.104
0 0
0.30 0 %
_
13 NE
Exterior
Conc Blk - Poly
S1
4.0
14.0
0
12.0 0 168.0 0.104
0 0
0.30 0 %
_
14 SE
Exterior
Conc Blk - Poly
S1
4.0
28.7
0
12.0 0 344.0 0.104
0 0
0.30 0 %
_
15 NW
Exterior
Conc Blk - Poly
S1
4.0
7.0
0
12.0 0 84.0 0.104
0 0
0.30 0 %
DOORS
(Total Exposed Area = 24 sq.ft.)
Width
Height
V # Ornt
Adjacent To Door Type
Space
Storms
U-Value Ft In
Ft In
Area
1 NW
Exterior
Insulated
S1
None
0.30 3.00 0
8.00 0
24.0ft2
WINDOWS
(Total Exposed Area = 363 sq.ft.)
I Wall
\V # Ornt ID
Frame
Panes NFRC
U-Factor
SHGC
Imp Storm
Area
-----Overhang-----
Depth Separation
Interior Shade
Screening
1 NE
1
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
10.OW
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
- 2 NW
2
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
10.0ft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
3 SW
3
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
10.Oft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
_
4 SE
4
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
10.0ft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
_
5 NE
5
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
72.0ft2
13.0 ft 0 in 0.5 ft 0 in
None
None
_
6 NE
5
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
24.0ft2
13.0 ft 0 in 0.5 ft 0 in
None
None
_
7 SW
6
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
24.0ft2
13.0 ft 0 in 0.5 ft 0 in
None
None
_
8 SW
6
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
72.0ft2
13.0 ft 0 in 0.5 ft 0 in
None
None
_
9 NW
7
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
15.0ft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
_
10NW
7
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
6.7ft2
3.0 ft 0 in 5.5 ft 0 in
Drapes/blinds
Exterior 100%
- 11 NE
8
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
6.7ft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
- 12SW
9
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
3.3ft2
3.0 ft 0 in 5.5 ft 0 in
Drapes/blinds
Exterior 100%
13SW
9
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
15.Oft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
_
14SW
11
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
15.0ft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
_
15SW
11
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
4.0ft2
3.0 ft 0 in 5.5 ft 0 in
Drapes/blinds
Exterior 100%
_
16SE
12
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
15.0ft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
_
17SE
12
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
4.0ft2
3.0 ft 0 in 5.5 ft 0 in
Drapes/blinds
Exterior 100%
_
18SE
14
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
15.Oft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
_
19SE
14
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
12.0ft2
3.0 ft 0 in 5.5 ft 0 in
Drapes/blinds
Exterior 100%
_
20NE
13
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
4.Oft2
3.0 ft 0 in 5.5 ft 0 in
Drapes/blinds
Exterior 100%
_
21 NE
13
Vinyl
Low-E Double
Yes
0.35
0.20
N
N
15.0ft2
3.0 ft 0 in 0.5 ft 0 in
Drapes/blinds
Exterior 100%
INFILTRATION
# Scope
Method
SLA CFM50
ELA
EgLA
ACH ACH50
Space(s)
1 Wholehouse Proposed ACH(50)
0,00064 2832
155.36
291.67
0.1731 7.0
All
9/13/2021 1:16:21 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
V # Mass Type
Area
Thickness Furniture Fraction Space
1 Default(8 Ibs/sq.ft.)
0 ftz
0 ft
0.30
S1
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI # Efficiency Capacity ----Geothermal HeatPump----
Ducts Block
kBtu/hr Entry
Power Volt
Current
_ 1 Electric Heat Pump
Split/Single
201755942HSPF: 10.60 28.6
0.00 0.00
0.00
sys#0 1
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI # Efficiency
Capacity
Air Flow
SHR
Duct Block
kBtu/hr
cfm
1 Central Unit
Split/Single
201755942 SEER:19.0 28.4
852
0.75
Ductless 1
HOT WATER SYSTEM
# System Type Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
1 Electric Heat Pump
S1
0.92 (1.26) 40.00 gal 40 gal
120 deg
Standard None
92
Recirculation Recirc
Control
Loop Branch Pump DWHR
Facilities Equal DWHR
Other Credits
System Type
length
length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA NA
None
DUCTS
Duct---------Supply------------------Return---------
# Location R-Value Area Location R-Value Area Leakage Type
Air
Handler
CFM 25 CFM 25
TOT OUT
QN
HVAC #
RLF Heat Cool
TEMPERATURES
Programable Thermostat: Y
Cooling [ ]Jan [ ] Feb
[ ] Mar [ Apr
Ceiling Fans: N
; ] May [X] Jun [X] Jul
[X] Aug
[X] Sep [ ] Oct
[ ] Nov Dec [ ]
Heating [X] Jan [X] Feb
[X] Mar [ 3 Apr
[ ] May [ ] Jun [ ] Jul
[ j Aug
[ ] Sep [Oct
[X] Nov [X] Dec
Venting [ ] Jan [ ] Feb
[X] Mar [X] Apr
[ ] May [ ] Jun [ ] Jul
[ ] Aug
[ ] Sep [X] Oct
[X] Nov [ ] Dec
I Thermostat Schedule. HERS 2006 Reference
2
Hours
3 4 5 6 7
3 9
10
11 12
V Schedule Type
1
Cooling (WD) AM
PM
78 78
80 80
78 78 78 78
78 78 78 78
78
78
78 80
78 78
80
78
80 80
78 78
_ Cooling (WEH) AM
PM
78 78
78 78
78 78 78 78
78 78 78 78
78
78
78 78
78 78
78
78
78 78
78 78
_ Heating (WD) AM
PM
66 66
68 68
66 66 66 68
68 68 68 68
68
68
68 68
68 68
68
68
68 68
66 66
Heating (WEH) AM
PM
66 66
68 68
66 66 66 68
68 68 68 68
68
68
68 68
68 68
68
68
8 68
66 66
9/13/2021 1:16:21 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 59
The lower the EnergyPerformance Index, the more efficient the home.
Southwind Trail,Fort Pierce,FL,34951
1. New construction or existing New (From Plans)
2. Single family or multiple family
Detached
3. Number of units, if multiple family
1
4. Number of Bedrooms
1
5. Is this a worst case?
No
6. Conditioned floor area above grade (ft2)
1697
Conditioned floor area below grade (ft2)
0
7. Windows** Description
Area
a. U-Factor: Dbl, U=0.35
362.65 ft2
SHGC: SHGC=0.20
b. U-Factor: N/A
ft2
SHGC:
c. U-Factor: N/A
ft2
SHGC:
Area Weighted Average Overhang Depth:
8.294 ft
Area Weighted Average SHGC:
0.200
8, Skylights Description
Area
U-Factor:(AVG) N/A
N/A ft2
SHGC(AVG): N/A
9. Floor Types Insulation
Area
a. Slab -On -Grade Edge Insulation R= 0.0
1696.70 ft2
b. N/A R=
ft2
c. N/A R=
ft2
10. Wall Types(3798.1 sqft.)
Insulation
Area
a. Concrete Block - Polystyrene Beacf'*995--ga87,,g5d&
tb
b. N/A
R=
ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
11. Ceiling Types(1696.7 sqft.)
Insulation
Area
a. Cathedral/Single Assembly (UnventeArl.0
1696.70 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
12. Ducts, location & insulation level
R ft2
a.
b.
C.
13. Cooling Systems
kBtu/hr
Efficiency
a. Central Unit
28.4 SEER:19.00
14. Heating Systems
kBtu/hr
Efficiency
a. Electric Heat Pump
28.6 HSPF:10.60
15. Hot Water Systems
a. Electric Cap: 40 gallons
UEF: 1.260
b. Conservation features
None
16. Credits CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home: Southwind Trail
Date:
City/FL Zip: Fort Pierce,FL,34951
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/13/2021 1:16:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: I Permit #:
Job Information
Builder: G.M. Worley, Inc. Community: Lot: NA
Address: Southwind Trail
City: Fort Pierce State: FL Zip: 34951
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, orERi Method
O PRESCRIPTIVE METHOD-The.building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding:? air
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2.
40 PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50) value, as shown on Form R405-2020 (Performance) or R406-2020 (ERI), section labeled as infiltration, sub -section ACI450.
ACH(50) specified on Form R405-2020-Energy Cale (Performance) or R406-2020 (ERIJ 7.000
x 60 _ 5,163682E32 =
CFM(50) Building Volume ACH(50)
PASS
When ACH(50) is less than 3, Mechanical Ventilation installation
must be verified by building department.
Method for calculating building volume:
O Retrieved from architectural plans
• Code software calculated
O Field measured and calculated
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester:
Printed Name of Tester:
License/Certification #:
Date of Test:
Issuing Authority:
9/13/2021 1:16:32 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Walls Page 2 of 5
Current Wall
The Current Wall Number shown on the top of the screen corresponds to the Wall ID field on
the Doors and Windows screens.
Orient: Select the orientation of the current wall from the pull -down menu.
Type: Select the appropriate wall type from the pull -down menu.
Frame - Wood / Steel: Vertical and horizontal
structural elements of the wall are primarily formed by
a system of repetitive wood or light gage steel framing
members.
Concrete Block - Int Insul / Ext Insul: Concrete
masonry unit structural walls with either insulation on
the interior side of the block (Int Insul) or exterior side
of the block (Ext Insul).
Face Brick - Wood / Block / Steel: Wood frame,
concrete block or light gauge steel walls with brick
facing.
Log - 6 inch /8 inch: Log walls of either 6 inch or 8
inch diameter. Note that if there is no added
insulation, the Wall Cavity Ins. Fl-value entry is 0.
Autoclaved Concrete Block - Int Insul: Autoclaved
concrete masonry unit structural walls (either
autoclaved aerated concrete or autoclaved cellular
concrete) with either no added insulation or added
interior insulation. Note that if there is no added
insulation, the Wall Cavity Ins. F'-value entry is 0.
Autoclaved Concrete Block - Ext Insul: Autoclaved
concrete masonry unit structural walls (either
autoclaved aerated concrete or autoclaved cellular
concrete) with either no added insulation or added
exterior insulation. Note that if there is no added
insulation, the Wall Cavity Ins. R-value entry is 0.
Concrete Block - Polystyrene Bead Aggregate. -
Concrete masonry unit structural walls with
polystyrene bead filled cores. Note that if there is no
insulation in addition to the filled cores, the Wall
Cavity Ins. R-value entry is 0.
Insulated Concrete Form: Poured concrete walls with
surrounding foam forms. The Wall Cavity Ins. R-value
entry is the R-value of the total thickness of the foam
insulation, not including the thickness of the concrete.