Loading...
HomeMy WebLinkAboutREV ENERGY CALCSFORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: ❑ This checklist ❑ Form R405-2020 report ❑ Input summary checklist that can be used for field verification (usually four pages/may be greater) ❑ Energy Performance Level (EPL) Display Card (one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) 9/13/2021 1:16:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Skopelja Builder Name: G.M. Worley, Inc. Street: Southwind Trail Permit Office: City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: William Skopelja Jurisdiction: Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT County: Indian River(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wail Types(3798.1 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead dega8Y,,9M&if* ft2 b. NIA R= 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 No 11. Ceiling Types(1696.7 sqft.) Insulation Area 5. Is this a worst case? a. Cathedral/Single Assembly (Unventdld�11.0 1696.70 ft2 6. Conditioned floor area above grade (ft2) 1697 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(362.6 sgft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Dbl, U=0.35 362.65 ft2 a. SHGC: SHGC=0.20 b• b. U-Factor: N/A ft2 SHGC: C. 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 28.4 SEER:19.00 SHGC: Area Weighted Average Overhang Depth: 8.294 ft Area Weighted Average SHGC: 0.200 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 28.6 HSPF:10.60 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 15. Hot Water Systems 9. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1696.70 ft2 UEF: 1.260 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 16. Credits CF, Pstat Glass/Floor Area: 0.214 Total Proposed Modified Loads: 43.80 PASS Total Baseline Loads: 74.49 I hereby certify that the plans and specifications covered by Review of the plans and SHE S7',gT this calculation are in compliance with the Florida Energy specifications covered by this 0 _ - t ' Code. calculation indicates compliance rf, , with the Florida Energy Code. i`""r PREPARED BY: Before construction is completed r ^�3'Z this building will be inspected for Cd _ DATE: compliance with Section 553.908 a Florida Statutes. I hereby certify that this building, as designed, is in compliance tspn W with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Proposed Qn of NAN exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). requires a PERFORMANCE 9/13/2021 1:16:21 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Title: Skopelja Building Type: User Owner: William Skopelja Builder Name: G.M. Worley, Inc. Permit Office: Jurisdiction: Family Type: Detached New/Existing: New (From Plans) Year Construct: Comment: PROJECT Bedrooms: 1 Conditioned Area: 1697 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Terrain: Flat Terrain Shielding: Light shielding CLIMATE Design Design Temp 1/ Location Tmy Site 97.5% 2.5% _ FL, VERO_BEACH_MUNICIP FL_VERO_BEACH_MUNICIPA 45 90 BLOCKS Number Name Area Volume 1 Block1 1696.74902343714272.130859375 Number Name S1 # Floor Type 1 Slab -On -Grade Edge Ins f # Type 1 Hip # Type 1 Full cathedral ceiling Address type: Street Address Lot #: --- Block/SubDivision: --- PlatBook: Street: Southwind Trail County: Indian River City, State, Zip: Fort Pierce, FL, 34951 Int Design Temp Heating Design Daily temp Winter Summer Degree Days Moisture Range 70 75 299 64 Medium SPACES Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1696.74902328282.1305201953 Yes 2 1 Yes Yes Yes FLOORS (Total Exposed Area = 1697 sq.ft.) Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet S1 266 0 1696.749 ft 0.710 1.00 0.00 0.00 Materials Metal f # Ceiling Type _ 1 Cathedral/Single Assembly(Unvented) Ventilation Unvented ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Area Area Color Barr Absor. Tested Tested Insul. (deg) 1897 ftz 0 ftZ Medium N 0.3 No 0.9 No 20 26.57 ATTIC Vent Ratio (1 in) Area RBS IRCC 0 1696.749 ftZ N N CEILING (Total Exposed Area = 1697 sq.ft.) Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type S1 1.0 Blown 1696.7ft2 0.047 0.11 Wood 9/13/2021 1:16:21 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 3798 sq.ft.) Adjacent Cavity Width Height Area U- Sheath Frm, Solar Below V# Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade 1 NE Exterior Conc Blk - Poly S1 4.0 17.0 0 23.0 0 391.0 0.104 0 0 0.30 0 % �_ 2 NW Exterior Conc Blk - Poly S1 4.0 17.0 0 23.0 0 391.0 0.104 0 0 0.30 0 % 3 SW Exterior Conc Blk - Poly S1 4.0 17.0 0 23.0 0 391.0 0.104 0 0 0.30 0 % _ 4 SE Exterior Conc Blk - Poly S1 4.0 17.0 0 23.0 0 391.0 0.104 0 0 0.30 0 % _ 5 NE Exterior Conc Blk - Poly S1 4.0 17.0 0 8.0 0 136.0 0.104 0 0 0.30 0 % _ 6 SW Exterior Conc Blk - Poly S1 4.0 17.0 0 8.0 0 136.0 0.104 0 0 0.30 0 % _ 7 NW Exterior Conc Blk - Poly S1 4.0 34.0 0 12.0 0 408.0 0.104 0 0 0.30 0 % 8 NE Exterior Conc Blk - Poly S1 4.0 14.0 0 12.0 0 168.0 0.104 0 0 0.30 0 % - 9 SW Exterior Conc Blk - Poly S1 4.0 14.0 0 12.0 0 168.0 0.104 0 0 0.30 0 % - 10 SE Exterior Conc Blk - Poly S1 4.0 16.2 0 12.0 0 194.0 0.104 0 0 0.30 0 % 11 SW Exterior Conc Blk - Poly S1 4.0 18.0 0 12.0 0 216.0 0.104 0 0 0.30 0 % _ 12 SE Exterior Conc Blk - Poly S1 4.0 17.7 0 12.0 0 212.0 0.104 0 0 0.30 0 % _ 13 NE Exterior Conc Blk - Poly S1 4.0 14.0 0 12.0 0 168.0 0.104 0 0 0.30 0 % _ 14 SE Exterior Conc Blk - Poly S1 4.0 28.7 0 12.0 0 344.0 0.104 0 0 0.30 0 % _ 15 NW Exterior Conc Blk - Poly S1 4.0 7.0 0 12.0 0 84.0 0.104 0 0 0.30 0 % DOORS (Total Exposed Area = 24 sq.ft.) Width Height V # Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 NW Exterior Insulated S1 None 0.30 3.00 0 8.00 0 24.0ft2 WINDOWS (Total Exposed Area = 363 sq.ft.) I Wall \V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area -----Overhang----- Depth Separation Interior Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.35 0.20 N N 10.OW 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% - 2 NW 2 Vinyl Low-E Double Yes 0.35 0.20 N N 10.0ft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% 3 SW 3 Vinyl Low-E Double Yes 0.35 0.20 N N 10.Oft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% _ 4 SE 4 Vinyl Low-E Double Yes 0.35 0.20 N N 10.0ft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% _ 5 NE 5 Vinyl Low-E Double Yes 0.35 0.20 N N 72.0ft2 13.0 ft 0 in 0.5 ft 0 in None None _ 6 NE 5 Vinyl Low-E Double Yes 0.35 0.20 N N 24.0ft2 13.0 ft 0 in 0.5 ft 0 in None None _ 7 SW 6 Vinyl Low-E Double Yes 0.35 0.20 N N 24.0ft2 13.0 ft 0 in 0.5 ft 0 in None None _ 8 SW 6 Vinyl Low-E Double Yes 0.35 0.20 N N 72.0ft2 13.0 ft 0 in 0.5 ft 0 in None None _ 9 NW 7 Vinyl Low-E Double Yes 0.35 0.20 N N 15.0ft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% _ 10NW 7 Vinyl Low-E Double Yes 0.35 0.20 N N 6.7ft2 3.0 ft 0 in 5.5 ft 0 in Drapes/blinds Exterior 100% - 11 NE 8 Vinyl Low-E Double Yes 0.35 0.20 N N 6.7ft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% - 12SW 9 Vinyl Low-E Double Yes 0.35 0.20 N N 3.3ft2 3.0 ft 0 in 5.5 ft 0 in Drapes/blinds Exterior 100% 13SW 9 Vinyl Low-E Double Yes 0.35 0.20 N N 15.Oft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% _ 14SW 11 Vinyl Low-E Double Yes 0.35 0.20 N N 15.0ft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% _ 15SW 11 Vinyl Low-E Double Yes 0.35 0.20 N N 4.0ft2 3.0 ft 0 in 5.5 ft 0 in Drapes/blinds Exterior 100% _ 16SE 12 Vinyl Low-E Double Yes 0.35 0.20 N N 15.0ft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% _ 17SE 12 Vinyl Low-E Double Yes 0.35 0.20 N N 4.0ft2 3.0 ft 0 in 5.5 ft 0 in Drapes/blinds Exterior 100% _ 18SE 14 Vinyl Low-E Double Yes 0.35 0.20 N N 15.Oft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% _ 19SE 14 Vinyl Low-E Double Yes 0.35 0.20 N N 12.0ft2 3.0 ft 0 in 5.5 ft 0 in Drapes/blinds Exterior 100% _ 20NE 13 Vinyl Low-E Double Yes 0.35 0.20 N N 4.Oft2 3.0 ft 0 in 5.5 ft 0 in Drapes/blinds Exterior 100% _ 21 NE 13 Vinyl Low-E Double Yes 0.35 0.20 N N 15.0ft2 3.0 ft 0 in 0.5 ft 0 in Drapes/blinds Exterior 100% INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0,00064 2832 155.36 291.67 0.1731 7.0 All 9/13/2021 1:16:21 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS V # Mass Type Area Thickness Furniture Fraction Space 1 Default(8 Ibs/sq.ft.) 0 ftz 0 ft 0.30 S1 HEATING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity ----Geothermal HeatPump---- Ducts Block kBtu/hr Entry Power Volt Current _ 1 Electric Heat Pump Split/Single 201755942HSPF: 10.60 28.6 0.00 0.00 0.00 sys#0 1 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split/Single 201755942 SEER:19.0 28.4 852 0.75 Ductless 1 HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric Heat Pump S1 0.92 (1.26) 40.00 gal 40 gal 120 deg Standard None 92 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS Duct---------Supply------------------Return--------- # Location R-Value Area Location R-Value Area Leakage Type Air Handler CFM 25 CFM 25 TOT OUT QN HVAC # RLF Heat Cool TEMPERATURES Programable Thermostat: Y Cooling [ ]Jan [ ] Feb [ ] Mar [ Apr Ceiling Fans: N ; ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov Dec [ ] Heating [X] Jan [X] Feb [X] Mar [ 3 Apr [ ] May [ ] Jun [ ] Jul [ j Aug [ ] Sep [Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec I Thermostat Schedule. HERS 2006 Reference 2 Hours 3 4 5 6 7 3 9 10 11 12 V Schedule Type 1 Cooling (WD) AM PM 78 78 80 80 78 78 78 78 78 78 78 78 78 78 78 80 78 78 80 78 80 80 78 78 _ Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM PM 66 66 68 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 66 68 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 8 68 66 66 9/13/2021 1:16:21 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 59 The lower the EnergyPerformance Index, the more efficient the home. Southwind Trail,Fort Pierce,FL,34951 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 1 5. Is this a worst case? No 6. Conditioned floor area above grade (ft2) 1697 Conditioned floor area below grade (ft2) 0 7. Windows** Description Area a. U-Factor: Dbl, U=0.35 362.65 ft2 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 SHGC: c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 8.294 ft Area Weighted Average SHGC: 0.200 8, Skylights Description Area U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1696.70 ft2 b. N/A R= ft2 c. N/A R= ft2 10. Wall Types(3798.1 sqft.) Insulation Area a. Concrete Block - Polystyrene Beacf'*995--ga87,,g5d& tb b. N/A R= ft2 c. N/A R= ft2 d. N/A R= ft2 11. Ceiling Types(1696.7 sqft.) Insulation Area a. Cathedral/Single Assembly (UnventeArl.0 1696.70 ft2 b. N/A R= ft2 c. N/A R= ft2 12. Ducts, location & insulation level R ft2 a. b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 28.4 SEER:19.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 28.6 HSPF:10.60 15. Hot Water Systems a. Electric Cap: 40 gallons UEF: 1.260 b. Conservation features None 16. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Southwind Trail Date: City/FL Zip: Fort Pierce,FL,34951 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/13/2021 1:16:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: I Permit #: Job Information Builder: G.M. Worley, Inc. Community: Lot: NA Address: Southwind Trail City: Fort Pierce State: FL Zip: 34951 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, orERi Method O PRESCRIPTIVE METHOD-The.building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding:? air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. 40 PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2020 (Performance) or R406-2020 (ERI), section labeled as infiltration, sub -section ACI450. ACH(50) specified on Form R405-2020-Energy Cale (Performance) or R406-2020 (ERIJ 7.000 x 60 _ 5,163682E32 = CFM(50) Building Volume ACH(50) PASS When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume: O Retrieved from architectural plans • Code software calculated O Field measured and calculated R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Printed Name of Tester: License/Certification #: Date of Test: Issuing Authority: 9/13/2021 1:16:32 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Walls Page 2 of 5 Current Wall The Current Wall Number shown on the top of the screen corresponds to the Wall ID field on the Doors and Windows screens. Orient: Select the orientation of the current wall from the pull -down menu. Type: Select the appropriate wall type from the pull -down menu. Frame - Wood / Steel: Vertical and horizontal structural elements of the wall are primarily formed by a system of repetitive wood or light gage steel framing members. Concrete Block - Int Insul / Ext Insul: Concrete masonry unit structural walls with either insulation on the interior side of the block (Int Insul) or exterior side of the block (Ext Insul). Face Brick - Wood / Block / Steel: Wood frame, concrete block or light gauge steel walls with brick facing. Log - 6 inch /8 inch: Log walls of either 6 inch or 8 inch diameter. Note that if there is no added insulation, the Wall Cavity Ins. Fl-value entry is 0. Autoclaved Concrete Block - Int Insul: Autoclaved concrete masonry unit structural walls (either autoclaved aerated concrete or autoclaved cellular concrete) with either no added insulation or added interior insulation. Note that if there is no added insulation, the Wall Cavity Ins. F'-value entry is 0. Autoclaved Concrete Block - Ext Insul: Autoclaved concrete masonry unit structural walls (either autoclaved aerated concrete or autoclaved cellular concrete) with either no added insulation or added exterior insulation. Note that if there is no added insulation, the Wall Cavity Ins. R-value entry is 0. Concrete Block - Polystyrene Bead Aggregate. - Concrete masonry unit structural walls with polystyrene bead filled cores. Note that if there is no insulation in addition to the filled cores, the Wall Cavity Ins. R-value entry is 0. Insulated Concrete Form: Poured concrete walls with surrounding foam forms. The Wall Cavity Ins. R-value entry is the R-value of the total thickness of the foam insulation, not including the thickness of the concrete. mk: @MSITStore: C:\Users\User\AppData\Local\EnergyGaugeUSA7\Help\EnergyGauge_... 9/ 10/2021