Loading...
HomeMy WebLinkAboutAPPROVED WIND LOADS(10)Planning & Deveopment Services Q lapartment Building & Code Regulations Division • •'' 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1577 Certification for Design Load Compliance 71 Edition Project Name: William & Regina Skopelja ProjectAddre": TBD Southwind Trail, Fort Pierce, FL 34951 Permit #:. —Occupancy Type: Single Family^New ConatISFR Construction Type: Il�JCiIONS FOR USE — • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent Information, St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still • All digital files must be in an unlocked Portable Document Format (PDF) version required * Note: Form not required for interior renovations provided that at exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIG PAR (METERS AND ASSuivLpno pis USED: (complete all that apply) 1, DESIGN CODE: Florlda2020 Code 7th Edition using ASCE 7-16 2. Structure Designed as(check one): X Enclosed Partially Enclosed ____Open S. Risk Category: 1 II `ill IV Exposure Category: BLX C —D 4. Design Wind Velocity � 60 S. Mean Roof Height.'C30 mphggp LRFD End Zone Width:_`ft - - ft Roof Pitch: 5 :12 Parapet:.ft 6. Components & Cladding Design Pressures Used. Zone 4: Zone S:_ i /A Garage: a. o Maximum +/- pressures: + psf - psf Or define Individual zones on the plans 7. Design Loads: Floor:40_p ---t PSF Roof -Dead'. Roof -Live . c.C. Z'D BalcNIA PSF Dock: NIA PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A _ -- - PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure?X — — Yes Nat Applicable Please Explain: 9. is a Continuous Load Path Provided?%- Yes Not Applicable Explain Why Not: 10. Design Sol[ Bearing Pressure.2500 .PSF Soil Test Reports Submitted? Yes No DESIGN PROFESSIONAL CERTIFICATION STATEMENT; ' certify that, to thed best of my knowledge and belief, the attached plans & specifications have been designed to Edward FAv" %i ( applicable structural portions of the current Florida Building Code as adopted. by dwar Shinskie Shinskie Jr. —fie:_2�1 n(L a 2Q __ �dti+.lcr ax Sig �f@A dSeal rThis iter. has beenn electronically signed and sealed by Print Name Cert # & Co. Cert ofAuthorization Edward F. Slunshie, PE on the Date and/or Time stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified Company Name & Address on any electronic copy.i mS �(r 3� amity