Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: 1 n DATE FILED: 1 a-I PERMIT# O "� REVISION FEE: '��.b0 RECEIPT# PLANNING & DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE RECETVD FORT PIERCE, FL 34982-5652 (772)462-1553 O C T 14 2021 APPLICATION FOR BUILDING PERMIT REVISI T. Lucie County, Permitting PROJECT INFORMATION LOCATION/SITE ADDRESS: ��3 r�✓)S�� �3 cam, L S2 DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC1330146 ST. LUCIE CO CERT. #: 29179 BUSINESS NAME: ADAMS HOMES OF NORTHWEST FLORIDA, INC. QUALIFIERS NAME: WILLIAM BRYAN ADAMS ADDRESS: 3000 GULF BREEZE PARKWAY CITY: GULF BREEZE STATE: FL ZIP; 32563 PHONE (DAYTIME): 772-905-8394 Fes{; 772-905-8511 OWNER/BUILDER INFORMATION: NAME: ADAMS HOMES OF NORTHWEST FLORIDA,INC. ADDRESS:3000 GULF BREEZE PARKWAY CITY: GULF BREEZE STATE: FL ZIP: 32563 PHONE (DAYTIME: 772-905-8394 FAX: 772-905-8511 ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: FIVP (�npu SLCCC.• 9/23/09 R"'s Revised 06130/17 N RECEIVED � FORM R405-2020 OCT 14 2021 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING-GO TRU iT N Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 25 Block 46-7 IndianRiverEstates 1755 AGR Builder Name: ADAMS HOMES Street: 5003 Sunset Boulevard Permit Office: City,State,Zip: Fort Pierce, FL,34982 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL,ST_LUCIE_CO_INTL County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type�1512.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1348.00 ft2 b.Frame-Wood,Adjacent R=13.0 164.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11.Ceiling Types (1819.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1760.00 ft2 6. Conditioned floor area above grade(ft2) 1760 b. Knee Wall(Vented) R=19.0 59.00 ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 7. Windows(212.0 sqft.) Description Area 12. Ducts R ft2 a.Sup:Attic, Ret:Main,AH: Main 6 352 a. U-Factor: Dbl,U=0.33 129.50 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 46.38 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 35.0 SEERA6.00 c. U-Factor: Dbl,U=0.31 18.33 ft2 SHGC: SHGC=0.22 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 5.817 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.264 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a. Electric Cap:40 gallons 9. Floor Types (1760.0 sqft.) Insulation Area EF:0.940 a.Slab-On-Grade Edge Insulation R=0.0 1760.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.120 PASS Total Proposed Modified Loads: 52.28 P/yASS Total Baseline Loads: 56.07 I hereby certify that the plans an ions covered b Review the plans and ��HE S74 this calculation are in complian gy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. Ift rm,r.. '' PREPARED BY: Before construction is completed O DATE: 10-19-217121 Winn KPnmany this building will be inspected for 0 �. compliance with Section 553.908 * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Enerav Code. C0D yW-E OWN R/AG _J BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR goy CODE COMPLIANCE FILE COPY ST. LUCIE COUNTY 10/12/2021 4:30 PM EnergyGauge®USA 7.0.t$Oe&0 FBC 7th Edition(2020) Compliant Software Page 1 of 4 REVISION FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 25 Block 46-7 IndianRiver Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1760 Lot# 25 Owner Name: Total Stories: 1 Block/Subdivision: IndianRiverEst. #of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5003 Sunset Boulevard Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce, Family Type: Detached FL, 34982 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST LUCIE CO INTL FL VERO BEACH MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1760 15136 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1760 15136 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 167.5 ft 0 1760 ft2 ____ 0.33 0 0.67 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1968 ft2 440 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1760 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Knee Wall(Vented) Main 19 Batt 59 ft2 0.11 Wood 2 Under Attic(Vented) Main 30 Blown 1760 ft2 0.11 Wood 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NW Exterior Concrete Block-Int Insul Main 4.1 43 0 8 0 344.0 ft2 0 0 0.6 0 2 NE Exterior Concrete Block-Int Insul Main 4.1 34 0 8 0 272.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block-Int Insul Main 4.1 37 0 8 0 296.0 ft2 0 0 0.6 0 4 SW Exterior Concrete Block-Int Insul Main 4.1 54 6 8 0 436.0 ft2 0 0 0.6 0 5 - Garage Frame-Wood Main 13 20 6 8 0 164.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .25 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 2 NE 2 Vinyl Low-E Double Yes 0.31 0.22 N 5.0 ft2 9 ft 0 in 0 ft 5 in None None 3 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 46.4 ft2 1 ft 0 in 0 ft 10 in None Exterior 5 4 NE 2 Vinyl Low-E Double Yes 0.31 0.22 N 13.3 ft2 9 ft 0 in 2 ft 6 in None None 5 SW 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 4 in 0 ft 10 in None Exterior 5 6 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 7 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 64.8 ft2 11 ft 4 in 0 ft 10 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000382 1765.9 96.88 181.88 .13 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 352 ft2 Main 88 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr Ma X Jun X Jul JXJ Aug �Xj Se Oct Nov Dec Heatin H Jan HFeb Mar Apr May Jun Jul Au Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep �Xj Oct H Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. 5003 Sunset Boulevard, Fort Pierce, FL, 34982 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1348.00 ftz b. Frame-Wood,Adjacent R=13.0 164.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case.? No a. Under Attic(Vented) R=30.0 1760.00 ft2 6. Conditioned floor area(ft2) 1760 b. Knee Wall(Vented) R=19.0 59.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U Factor: Dbl,U=0.33 129.50 ft2 12.Ducts,location&insulation level R ft2 a.Sup:Attic, Ret:Main,AH: Main 6 352 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 46.38 ft2 SHGC: SHGC=0.21 13.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.31 18.33 ft2 a.Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.22 d. U-Factor: other(see details) 17.78 ft2 14.Heating systems kBtu/hr Efficiency SHGC: other(see details) a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 5.817 ft. Area Weighted Average SHGC: 0.264 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap:40 gallons EF: 0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1760.00 ft2 Credits(Performance method) Pstat b.N/A R= ft2 c. N/A R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building F fKE STAp Construction through the above energy saving features which will be installed (or exceeded) ,y� a �D in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: car a Address of New Home: City/FL Zip: ry gS *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 III • Manual S Compliance Report Job: Lot 25 Block 46-7Indian R... wri htsoft p Date: 5.9.16 9 Entire House By: DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM Project • • For: ADAMS HOMES I 0 C T 14 2021 5003 Sunset Boulevard,For[Pierce,FL 34982 LST. Lucie County, Permitting Cooling Equipment Design Conditions Outdoor design DB: 90.3 OF Sensible gain: 27840 Btuh Entering coil DB: 77.2OF Outdoor design WB: 77.3OF Latentgain: 4188 Btuh Entering coil WB: 63.5OF Indoor design DB: 75.0 OF Total gain: 32028 Btuh Indoor RH: 50% Estimated airflow: 1167 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC537AP03+FX4DNF037L00 Actual airflow: 1167 cfm Sensible capacity: 28482 Btuh 1020%of load Latent capacity: 4879 Btuh 117%of load Total capacity: 33361 Btuh 104%of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 38.0 OF Heat loss: 30646 Btuh Entering coil DB: 69.0OF Indoor design DB: 70.0 OF Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC537AP03+FX4DNF037L00 Actual airflow: 1167 cfm Output capacity: 30129 Btuh 98%of load Capacity balance: 35 OF Supplemental heat required: 517 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1167 cfm Output capacity: 7.8 kW 87%of load Temp.rise: 21 OF Meets all requirements ofACCA Manual S. FILE COPY - - wrightsoft- 2021-oa-1216:16:56 �,<,• .. „,,.,,,.m�., Righ[-&Ae®Uriversal 2021 21.0.07 RSU23828 Page 1 55AGR\Lot2561k46-71ndianRiverEstates1755AGR.np Calc=MJ8 Horse faces:NE REVISION Component Constructions Job: Lot 25 Block 46-7 Indian R omonen ... - wrightsoft' p Date: 5.9.16 Entire House By: DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM Project • • For: ADAMS HOMES 5003 Sunset Boulevard,Fort Pierce,FL 34982 Design Conditions Location: Indoor: Heating Cooling St Lude County Inti,FL,US Indoor temperature(T) 70 75 Elevation: 24 ft Design TD(OF) 32 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 5.7 56.4 Dry bulb(OF) 38 90 Infiltration: Daily range(OF) - 15 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft"F ft"F/Btuh Bwhift� Btuh Btuh/t= Btuh Walls Blk wall,stucco ext,r-2 ext bd ins,8"thk,1/2"gypsum board int fnsh ne 186 0.201 4.1 6.43 1199 4.03 751 se 296 0.201 4.1 6.43 1904 4.03 1193 sw 304 0.201 4.1 6.43 1954 4.03 1224 nw 328 0.201 4.1 6.43 2107 4.03 1320 all 1114 0.201 4.1 6.43 7164 4.03 4489 166-19ad:Knee wall,asphalt shingles roof mat,r-19 kw ins, 1/2"gypsum nw 59 0.049 19.0 1.57 93 2.58 152 board int fnsh Partitions 12C-Osw:Frm wall,stucco ext,r-13 cav ins, 1/2"gypsum board int fnsh, 222 0.091 13.0 2.91 647 1.61 357 2"x4"wood frm, 16"o.c.stud Windows 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/8" ne 47 0.330 0 10.6 494 16.6 776 thk;NFRC rated(SHGC=0.21);50%drapes,medium;1.33 ft overhang (5.3 ft window ht,0.83 ft sep.);6.67 ft head ht 2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr, 1/4"gap, 1/8" ne 5 0.310 0 9.92 53 19.8 106 thk;NFRC rated(SHGC=0.22);9 ft overhang(1 ft window ht,0.42 ft sep.);6.67 ft head ht 2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr, 1/4"gap, 1/8" ne 13 0.310 0 9.92 133 16.8 225 thk;NFRC rated(SHGC=0.22);50%drapes,medium;9 ft overhang(6.7 ft window ht,2.5 ft sep.);6.67 ft head ht 10C-v:2 glazing,clr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap, 1/8" sw 18 0.550 0 17.6 314 16.2 289 thk;NFRC rated(SHGC=0.70);11.33 ft overhang(6.7 ft window ht,0.83 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/8" sw 33 0.330 0 10.6 345 18.2 594 thk;NFRC rated(SHGC=0.23);1.33 ft overhang(5.3 ft window ht,0.83 ft nw 16 0.330 0 10.6 173 20.8 340 sep.);6.67 It head ht all 49 0.330 0 10.6 518 19.0 934 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8" sw 16 0.330 0 10.6 173 15.6 255 thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 ft overhang (5.3 ft window ht,0.83 ft sep.);6.67 ft head ht 41- wrightsoft" 2021-Oct-1216:16:56 M,,..•,A.,,,,.,,.�,•,. m Right-Sute@Uriversal202121.0.07RSU23828 Page 55AGRLo125Blk46-71ndianRiverEstates1755AGR.rtp Calc=W8 Ho se faces:NE 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8" sw 65 0.330 0 10.6 690 8.49 555 thk;NFRC rated(SHGC=0.23);50%drapes,medium;11.33 ft overhang (5.3 ft window ht,0.83 ft sep.);6.67 ft head ht Doors 11 JO:Door,mtl fbrgl type ne 20 0.600 6.3 19.2 384 17.5 350 11 DO:Door,wd sc type n 18 0.390 0 12.5 223 11.4 203 Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 1922 0.032 30.0 1.02 1968 1.68 3238 gypsum board int fnsh Floors 22A4pl:Bg floor,light dry soil,on grade depth 199 0.989 0 31.6 6282 0 0 wrightsaft- 2021-Oct-1216:16:56 «,.�,,•.� Right-Sute®Udversal202121.0.07RSLI23828 Page 55AGR\Lot25Blk46-71ndianRiverEstates1755AGR.np Calc=W8 Horse faces:NE Job: Lot 25 Block 46-7 Indian R... wrightsoft- Project Summary Date: 5.9.16 Entire House By- DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY.SANFORD.FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM Project Information For: ADAMSHOMES 5003 Sunset Boulevard,Fort Pierce,FL 34982 Notes: HA6/13/13 HA updated 2/8/14 JA UPDATED 8-18-15 L.S. 10-12-21 VW K Design Information Weather: St Lucie County Inti,FL,US Winter Design Conditions Summer Design Conditions Outside db 38 OF Outside db 90 OF Inside db 70 of Inside db 75 OF Design TD 32 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 56 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22617 Btuh Structure 18647 Btuh Ducts 8029 Btuh Ducts 9193 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30646 Btuh Use manufacturer's data y Rate/swing multipplier 1.00 Infiltration Equipment sensble load 27840 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2795 Btuh Ducts 1392 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Outside air Area(ft2) 1760 1760 Equipment latent load 4188 Btuh Volume(ft3) 15626 15626 Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 32028 Btuh Equiv.AVF(cfm) 99 52 Req.total capacity at 0.75 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC537AP03 Cond 25HBC537AP03 AHRI ref 204837926 Coil FX4DNF037L00 AHRI ref 204837926 Efficiency 8.5 HSPF Efficiency 12.5 EER, 16 SEER Heating input Sensible cooling 26250 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 8750 Btuh Temperature rise 27 OF Total cooling 35000 Btuh Actual air flow 1167 cfm Actual air flow 1167 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.30 in H2O Static pressure 0.30 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point=35 OF Ipciutt=8 kW, Output=26778 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft' 2021-Oct-1216:16.56 - mw•• Right-Sute®Uriversal 2021 21.0.07 RSU23828 Page 1 55AGR\Lot25Blk46-71ydianRiverEstates1755AGR.np Calc=MJ8 Horse faces:NE wrightsoft Right-J® Worksheet Job: Lot 25 Block 46-7Indian Riker... Entire House Date: 5.9.16 By: DEL AIR HTG, A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name Entire House BDRM2 2 Exposed vall 198.5 it 265 it 3 Room height 8.6 ft d 8.0 it heat/000l 4 Room dimensions 125 x 14.0 ft 5 Room area 1826.5 tF 175.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ft?) Load number (Btutvft2-`F) (BtuMP) or perimeter (it) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/PS Heat Cool Gross N/PS Heat Cool 6 Blk wall,stucco e)d 0.201 ne 6.43 4.03 272 186 1199 751 0 0 0 0 2A-2ov 0.330 ne 1056 16.57 47 0 494 776 0 0 0 0 213-2ty 0.310 ne 9.92 19B1 5 0 53 106 0 0 0 0 213-2N 0310 ne 9.92 16.82 13 0 133 225 0 0 0 0 11 11J0 0.600 ne 1920 17.49 20 20 384 350 0 0 0 0 W Blk wall,stucco ext 0.201 se 6.43 4.03 296 296 1904 1193 112 112 720 451 Blk Ml,stucco ext 0.201 sw 6.43 4.03 436 304 1954 1224 100 84 538 337 10C-v 0.550 sw 17.60 16.16 18 18 314 289 0 0 0 0 2A-2ov 0,330 sw 10.56 18.16 33 8 345 594 0 0 0 0 2A-2ov 0,330 sw 10.56 15.60 16 4 173 255 16 4 173 255 2A-2ov 0,330 sw 10.56 8.49 65 65 690 555 0 0 0 0 W 16B-19ad 0.049 nw 1.57 2.58 59 59 93 152 0 0 0 0 Blk wall,stucco eM 0.201 nw 6.43 4.03 344 328 2107 1320 0 0 0 0 2A-2ov 0330 rtw 10.56 20.81 16 0 173 340 0 0 0 0 PI 12C-Osw 0.091 - 2.91 1.61 240 222 647 357 0 0 0 0 L-D 11 DO 0.390 n 12.48 11.37 18 18 223 203 0 0 0 0 C 1613-30ad 0.032 1.02 1.68 1922 1922 1968 3238 175 175 179 295 F 22A-10 0.989 31.65 0.00 1827 199 6282 0 175 27 839 0 6 c)AED exarsion 1323 99 Envelope loss/gain 19136 13251 2449 1438 12 a) Infiltration 3480 876 524 132 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 4 920 0 0 Applianoesbther 3600 300 Subtotal(lines 6to 13) 22617 18647 2973 1870 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22617 18647 2973 1870 15 Duct loads 35%1 49%1 8029 9193 35% 49% 1056 922 Total room load 30646 27840 4029 2791 Air required(ctm) 1167 1167 153 117 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C - wVlw t:soft 2021-Oct-1216:16:56 �AA 1-1""111,111"""" " RigN-SLite®Uriversal 2021 21.0.07 RSU23828 Page 1 55AGR\Lot25Blk46-71ydianRiverEstates1755AGR.np Calc=MJ8 House faces:NE wrightsoft, Right-JO Worksheet Job: Lot 25 Block 46-7 Indian River.. Entire House Date: 5.9.16 By. DEL AIR HTG, A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name BATH BDRM3 2 Exposed well 6.0 ft 265 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaVbool 4 Room dimensions 9.0 x 6.0 it 12.5 x 14.0 it 5 Room area 54.0 ft2 175.0 ft' Ty Construction U-value or HTM Area (ftz) Load Area 02) Load number (Blu"2--F) (Bluh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat C001 Gross N/P/5 Heat Cool Gross N/P/S Heat Cool 6 Blk waft,stucco e1d 0201 ne 6.43 4.03 0 0 0 0 100 77 493 309 2A-2ov 0.330 ne 1056 1657 0 0 0 0 23 0 247 388 2B-2ty 0310 ne 9.92 19BI 0 0 0 0 0 0 0 0 2B-2ty 0310 ne 9.92 1682 0 0 0 0 0 0 0 0 11 11,10 0.600 ne 1920 17.49 0 0 0 0 0 0 0 0 W Blk veil,stucco ex! 0.201 se 6.43 4.03 48 48 309 193 112 112 720 451 Blk wall,stucco eM 0201 sw 6.43 4.03 0 0 0 0 0 0 0 0 t OC-v 0.550 sw 17.60 16.16 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 18.16 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 15.60 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 8.49 0 0 0 0 0 0 0 0 W 16B-19ad 0.049 nw 1.57 2.58 0 0 0 0 0 0 0 0 Blk wall,stucco ext 0201 nw 6.43 4.03 0 0 0 0 0 0 0 0 t-G 2A-2ov 0330 nw 1056 20BI 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 2.91 1.61 0 0 0 0 0 0 0 0 11 DO 0390 n 12.48 11.37 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 1.02 1.68 54 54 55 91 175 175 179 295 F 22A-1pl 0.989 31.65 0.00 54 6 190 0 175 27 839 0 6 c)AED excursion -5 -15 Envelope losstgain 554 280 2478 1428 12 a) Infiltration 119 30 524 132 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Applianoes/other 0 300 Subtotal(lines 6to 13) 673 309 3002 1859 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 673 309 3002 1859 15 Duct loads 135% 49% 239 153 35% 49% 1066 917 Total room load 911 462 1 4068 2776 Air required(dim) 35 19 155 116 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. ,` 1'I.F wrigt�tsoR- Right-Sute®Uriversa1202121.0.07 RSU23828 2021-Oct-1216:16:56Paget 55AGR\Lot25B1k46-71ndianRiverEstatesl755AGR.rip Calc=W8 House faces:NE wrightsoft• Right-JO Worksheet Job: Lot 25 Block 46-7Indian River.. Entire House Date: 5.9.16 By. DEL AIR HTG, A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name BDRM4 GREAT RM 2 Exposed well 18.0 ft 25.5 It 3 Room height 8.0 ft heatbool 9.4 ft heatbool 4 Room dimensions 1.0 x 187.0 It 1.0 x 426.9 It 5 Room area 187.0 f12 426.9 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (BtuW-F) (Btuh/lt2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/F/S Heat Cool Goss N/P/S Heat Cool 6 Blk well,stuoco eM 0.201 ne 6.43 4.03 104 81 518 325 68 29 188 118 2A-2ov 0.330 ne 1056 1657 23 0 247 388 0 0 0 0 2B-2fv 0.310 ne 9.92 1991 0 0 0 0 5 0 53 106 26-2fv 0.310 ne 9.92 16b2 0 0 0 0 13 0 133 225 11 11JD 0.600 ne 1920 17.49 0 0 0 0 20 20 384 350 W Blk well,stuoco ext 0.201 se 6.43 4.03 0 0 0 0 0 0 0 0 Blk well,stil00D ext 0201 sw 6.43 4.03 0 0 0 0 136 85 550 344 10C-v 0550 sw 17.60 16.16 0 0 0 0 18 18 314 289 2A-2ov 0.330 sw 1056 18.16 0 0 0 0 0 0 0 0 2A-2ov 0.330 sw 1056 15.60 0 0 0 0 0 0 0 0 2A-2ov 0.330 sw 1056 8A9 0 0 0 0 33 33 345 278 W 16&1gad 0.049 nw 1.57 258 0 0 0 0 33 33 52 85 yl &k wall,stucoo ext 0201 nw 6.43 4.03 40 40 257 161 0 0 0 0 L--G 2A-2ov 0.330 nw 1056 20B1 0 0 0 0 0 0 0 0 P 12C-OE7N 0.091 - 2.91 1.61 0 0 0 0 0 0 0 0 11 DO 0.390 n 12.48 11.37 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 1.02 1.68 187 187 191 315 484 484 495 815 F 22A-IpI 0.989 31.65 0.00 187 18 570 0 427 26 807 0 6 c)AED exairsion -6 638 Envelope loss/gain 1784 1183 3321 3248 12 a) Infiltration 356 90 586 148 b) Room ventilation 0 0 0 0 13 Internal gains Occupants Ca 230 0 0 2 460 Appliances/other 0 600 Subtotal(lines6 to 13) 2140 1273 3908 4455 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2140 1273 3908 4455 15 Duct loads 135% 49% 760 627 35% 49% 1387 2196 Total room load 2900 1900 5295 6651 Air required(cm) 110 80 1202 279 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. c - w�ftvt,csorc- 2021-Oct-1216:16:56 ...._...».._...._......_....-..._., Right_Sute®Uriversal 2021 21.0.07 RSU23828 . A Page 3 55AGR\Lot2581k46-71ydianRiverEstates1755AGR.np Calc=MJ8 House faces:NE wrightsoft Right-J® Worksheet Job: Lot 25 Block 46-7 Indian River.. Entire House Date: 5.9.16 By- DEL AIR KrG, A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name UTIL M BDRM 2 Exposed Hell 14.0 ft 29.0 ft 3 Room height 8.0 ft heaVcool 8.0 ft heaVcool 4 Room dimensions 11.0 x 6.0 ft 13.0 x 16.0 ft 5 Room area 66.0 ft2 208.0 ft2 Ty Construdion U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btu"2-19 (Btu"2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Hell,stu000 eA 0.201 ne 6.43 4.03 0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 1056 1657 0 0 0 0 0 0 0 0 2B-2fv 0310 ne 9.92 1991 0 0 0 0 0 0 0 0 2B-2fv 0310 ne 9.92 1682 0 0 0 0 0 0 0 0 11 11J0 0.600 ne 1920 17.49 0 0 0 0 0 0 0 0 W BIk Hell,stu000 ext 0.201 se 6.43 4.03 24 24 154 97 0 0 0 0 BIk Hell,sU=ext 0201 sw 6.43 4.03 0 0 0 0 104 71 459 287 10C-v 0550 sw 17.60 16.16 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 18.16 0 0 0 0 33 8 345 594 2A-2ov 0330 sw 1056 15.60 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 8A9 0 0 0 0 0 0 0 0 W 1613-19ad 0.049 nw 1.57 258 0 0 0 0 0 0 0 0 Blk Hell,stu000 ext 0201 nw 6.43 4.03 0 0 0 0 128 112 718 450 2A-2ov 0330 rry 1056 20B1 0 0 0 0 16 0 173 340 P 12C-Osw 0.091 - 2.91 1.61 88 70 204 113 0 0 0 0 11 DO 0.390 n 12.48 11.37 18 18 223 203 0 0 0 0 C 161130ad 0.032 1.02 1.68 66 66 68 111 208 208 213 350 F 22A-1pl 0.989 31.65 0.00 66 14 443 0 208 29 918 0 61 c)AED excursion -18 1381 Envelope loss/gain 1092 506 2825 2402 12 a) Infiltration 59 15 574 144 b) Room ventilation 0 0 0 0 13 Internal gains Occupants@ 230 0 0 1 230 Appliances�other 1600 1 1600 Subtotal(lines 6to 13) 1152 1121 3399 3377 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1152 1121 3399 3377 15 Dud loads 135% 49% 409 553 35% 49% 1207 1665 Total room load 1560 1673 46W 5042 Air required(cfm) 59 70 1175 211 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. w riyhtsoTt- 2021-Od-1216:16:56 �cA •"..-,.._-,..-.,`..,_.............. RigfY-Sule®Uriversa1202121.0.07RSU23828 Page 4 55AGR\Lot25Blk46-71ndianRiverEstates1755AGR.rnp Calc=W8 House faces:NE wrightsoft• Right-M Worksheet Job: Lot 25 Block 46-7Indian River... Entire House Date: 5.9.16 By. DEL AIR FrrG, A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name M BATH M WC 2 Exposed wall 255 It 0 it 3 Room height 8.0 ft heaVcool 8.0 ft heaV000l 4 Room dimensions 1.0 x 169.5 ft 3.5 x 5.0 ft 5 Room area 169.5 ft2 175 ftz Ty Construdion U-value Cr HTM Area (ft) Load Area (ftz) Load number (Btu"2-`9 (Btuh or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PS Heat Cool 6 Blk wall,stucco ext 0.201 ne 6.43 4.03 0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 1056 1657 0 0 0 0 0 0 0 0 2B-21v 0310 ne 9.92 19b1 0 0 0 0 0 0 0 0 2B-2ty 0310 ne 9.92 16 82 0 0 0 0 0 0 0 0 11 11Jo 0.600 ne 1920 17.49 0 0 0 0 0 0 0 0 W Blk Hell,stu000 ext 0.201 se 6.43 4.03 0 0 0 0 0 0 0 0 Blk Hall,stucco e1C 0201 sw 6.43 4.03 0 0 0 0 0 0 0 0 1OC-v 0.550 Sw 17.60 16.16 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 18.16 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 15.60 0 0 0 0 0 0 0 0 2A-2ov 0330 sw 1056 8.49 0 0 0 0 0 0 0 0 W 16B-19ad 0.049 nw 1.57 258 0 0 0 0 0 0 0 0 Blk Hall,stucco ext 0201 nw 6.43 4.03 128 128 823 516 0 0 0 0 2A-2ov 0330 nw 1056 20B1 0 0 0 0 0 0 0 0 PI 12C-0sw 0.091 - 2.91 1.61 76 76 221 122 0 0 0 0 L-D 11 DO 0390 n 12.48 11.37 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 1.02 1.68 170 170 174 286 18 18 18 29 F 22A-Ipl 0.989 31.65 0.00 170 26 807 0 18 0 0 0 6 c)AED exawrsion -16 0 Envelope loss/gain 2025 908 18 29 12 a) Infiltration 317 80 0 0 b) Room ventilation 0 0 0 0 13 Internal gains Oocupants@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal(lines 6to 13) 2342 988 18 29 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2342 988 18 29 15 Dud loads 135% 491/ 831 487 35% 49% 61 14 Total room load 3173 1474 24 43 Air required(dm) 121 62 1 1 2 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t �� vvr�yhtsoT!' 2021-Od-1216:16:56 Righl-Sute®Uriversa1202121.0.07RSU23828 Page 5 55AGFTLot2561k46-71ndianRiverEstates1755AGR.rup Calc=MJ8 House faces:NE + wrightsoft Right-JO Worksheet Job: Lot25 Block 46-7Indian Riker... Entire House Date: 5.9.16 By- DEL AIR HTG, A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:W W W OELAIR.COM 1 Room name M WIC DINING4<rrCHEN 2 Exposed Hell 15.5 ft 12.0 it 3 Room height 8.0 It heat/cool 9A it heatbool 4 Room dimensions 9.5 x 6.0 it 1.0 x 290.6 it 5 Room area 57.0 ft2 290.6 112 Ty Construction U-value Or HTM Area (112) Load Area (ft2) Load number (Btu"2-`f) (Btu"2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat cool Gross N/F/S Heat Cool 6 Blk wall,stucco ext 0.201 ne 6.43 4.03 0 0 0 0 0 0 0 0 2A-2ov 0.330 ne 10.56 16.57 0 0 0 0 0 0 0 0 26-2(v 0.310 ne 9.92 1981 0 0 0 0 0 0 0 0 2B-2fv 0310 ne 9.92 16.82 0 0 0 0 0 0 0 0 11 11JO 0.600 ne 1920 17A9 0 0 0 0 0 0 0 0 w Blk vrall,stuaro eM 0.201 se 6.43 4.03 0 0 0 0 0 0 0 0 Blk well,stucco ext 0.201 sw 6.43 4.03 0 0 0 0 96 63 407 255 10C-v 0.550 sw 17.60 16.16 0 0 0 0 0 0 0 0 2A-2ov 0,330 sw 1056 18.16 0 0 0 0 0 0 0 0 2A-2ov 0.330 sw 10.56 15.60 0 0 0 0 0 0 0 0 2A-2ov 0.330 sw 10.56 8.49 0 0 0 0 33 33 345 278 w 1613-19ad 0.049 nw 1.57 258 0 0 0 0 26 26 41 67 Blk vrall,stucco ex1 0201 nw 6.43 4A3 48 48 309 193 0 0 0 0 t--G 2A-2ov 0.330 nw 10,56 20B1 0 0 0 0 0 0 0 0 P. 12C-Osw 0.091 - 2.91 1.61 76 76 221 122 0 0 0 0 11 DO 0.390 n 12.48 11.37 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 1.02 1.68 57 57 58 96 329 329 337 555 F 22A-tpl 0.989 31 B5 0.00 57 16 491 0 291 12 380 0 6 c)AED excursion -7 272 Envelope loss/gain 1079 405 1510 1426 12 a) Infiltration 119 30 302 76 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Appliances/other 0 1200 Subtotal(lines6 to 13) 1198 435 1812 2932 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1198 435 1812 2932 15 Dud loads 35% 49% 425 214 35% 499% 643 1446 Total room load 1623 649 2455 4378 Air required(dm) 62 27 1 93 184 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t �" wrigF�tsotFt RigM-Sute8Uriversal 2021 21.0.07 RSU23828 2021-Oct-1216:16:56 Pa e 6 55AGR\Lot25B1k46-7lydianRiverEstates1755AGR.n p Calc=W8 House faces:NE g Duct System S Job: Lot 25 Block 46-71ndian R semumma ... wrightsoft Summary Date: 5.9.16 Entire House By. DEL AIR KG,A/C& REFRIG. INC 531 CODISCO WAY.SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM Project Information For: ADAMS HOMES 5003 Sunset Boulevard,Fort Pierce,FL 34982 Heating Cooling External static pressure 0.30 in H2O 0.30 in H2O Pressure losses 0.06 in H2O 0.06 in H2O Available static pressure 0.24 in H2O 0.24 in H2O Supply/return available pressure 0.120/0.120 in H2O 0.120/0.120 in H2O Lowest friction rate 0.172 in/100ft 0.172 in/100ft Actual air flow 1167 cfm 1167 cfm Total effective length(TEL) 140 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH h 911 35 19 0.310 4.0 Ox 0 VI Fx 7.4 70.0 BDRM 2 h 4029 153 117 0.294 7.0 Ox 0 VI Fx 11.7 70.0 BDRM 3 h 4068 155 116 0.304 7.0 Ox 0 M Fx 9.0 70.0 BDRM 4 h 2900 110 80 0.318 6.0 Ox 0 MFx 5.4 70.0 DINING/KfrCHEN c 4378 93 184 0.219 8.0 Ox0 MFx 24.4 85.0 st1 GREATRM c 6651 202 279 0.305 9.0 Ox0 MFx 8.6 70.0 M.BATH h 3173 121 62 0.175 5.0 Ox 0 M Fx 37.1 100.0 st2 M.BDRM c 5042 175 211 0.178 8.0 Ox 0 MFx 35.0 100.0 st2 M.We c 43 1 2 0.182 4.0 Ox 0 MFx 31.5 100.0 st2 M.WIC h 1623 62 27 0.172 4.0 Ox 0 MFx 39.9 100.0 st2 L1iIL c 1673 59 70 0.213 5.0 Ox 0 VIFx 27.7 85.0 st1 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 512 556 0.172 708 12.0 0 x 0 VinlFlx st2 PeakAVF 359 302 0.172 658 10.0 0 x 0 VinlFlx st1 ' Wrightsoft- 2021-Od-1216:16:57 •.• -, Right-SUteOUriversal 2021 21.0.07 RSU23828 Page 1 55AGR\Lot25Blk46-71ndianRiverEstates1755AGR.np Calc=W8 Horse faces:NE i Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W StudAbist Duct Name Size(in) (Cfm) (Cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mat Trunk rb1 Ox 0 1167 1167 0 0 0 0 Ox 0 VIFx wrightsoft, 2021-Od-1216:16:57 1 Right-SL te®Uriversal 2021 21. .007 RSU23828 ..,,..,., ,,.�....,.,.w.„ Paget 55AGR\Lot258lk46-71ydianRiverEstates1755AGR.nQ Calc=fvW8 Hose faces:NE 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 25 Block 46-7 IndianRiverEstates 1755 AGR Builder Name: ADAMS HOMES Street: 5003 Sunset Boulevard Permit Office: City,State,Zip: Fort Pierce,FL,34982 Permit Number: Y U Owner: Jurisdiction: 661000 W x Design Location: FL,ST_LUCIE_CO_INTL U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 9s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids rinklar cover olates and walls or cefinos a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance)Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: ❑ This checklist ❑ Form R405-2020 report ❑ Input summary checklist that can be used for field verification(usually four pages/may be greater) ❑ Energy Performance Level(EPL) Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -one page) ❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report-Performance Method(usually one page) 10/12/2021 4:29:44 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: 661000 Permit#: Job Information Builder: ADAMS HOMES Community: Lot: NA Address: 5003 Sunset Boulevard City: Fort Pierce State: FL Zip: 34982 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2. O PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on Form R405-2020(Performance)or R406-2020(ERI), section labeled as infiltration,sub-section ACH50. ACH(50)specified on Form R405-2020-Energy Calc(Performance)or R406-2020(ERI): 7.000 x 60 _ 15136 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans F-1 PASS 0 Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 10/12/2021 4:30:32 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition (2020)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5003 Sunset Boulevard Permit Number: Fort Pierce,FL ,34982 MANDATORY REQUIREMENTS -See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory).The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law ❑ (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOPE ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. ❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. ❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake, makeup air,backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. ❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls❑ that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system, including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for Section R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where Qn= duct leakage to the outside in cfm per 100 square feet of conditioned Floor area tested at 25 Pascals)is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F(IYC)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are installed,they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. ❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). ❑ R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140OF(38°C to 60°C). ❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of combustion types of service water-heating systems to be turned off. ❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. ❑ R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical ventilation,the air handler shall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based ❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU (CFM) (CFM/WATT) (CFM) HRV or ERV Any 1.2 cfm/watt Any Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less El than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50oF(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. El shall Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5 R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at u the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. R403.13 Dehumidifiers(Mandatory If installed,a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential. R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 10/12/2021 4:30 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5 I