HomeMy WebLinkAboutAPPROVED, Heffelfinger SOLAR PLANS(1)REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 5259010.80 kW PV SYSTEMCODES AND STANDARDS1008 ECHO ST,FORT PIERCE, FL 34982HEFFELFINGER RESIDENCEVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT SITEPROJECT DESCRIPTION:OWNERA-01ROOF PLANS-01MODULE LAYOUTS-02ATTACHMENT DETAILE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGDS-01-05DATA SHEETSSHEET SHEET DESCRITIONCOVER SHEETA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:DESIGN CRITERIA:WIND SPEED (ULT): 160 MPHWIND SPEED (ASD): 124 MPHRISK CATEGORY:IIEXPOSURE:CPROJECT SITESS-01.1ARTIAL RESSURE AND MODULES EXOSUREGO SOLAR POWER933 Clint Moore Rd,Boca Raton, FL 33487(800) 530-9597INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250, Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEERHEFFELFINGER, CLYDE27x400 CANADIAN : CS1Y-400MS (400W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESSYSTEM SIZE:10.800 kW DC STCARRAY AREA #1:585.06 SQ. FT.S-02.1STRUCTURE CALCULATIONHOUSE PHOTORACKING: IRONRIDGE XR10ATTACHMENT: S-5-N CLAMPEQUIPMENT SUMMARY27 CANADIAN : CS1Y-400MS (400W) MODULES27 ENPHASE: IQ7A-72-2-US MICROINVERTERGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)ASCE 7-16FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION.I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS. System DescriptionThis system is a grid-tied, PV system, with PV generation consisting of27x400 CANADIAN : CS1Y-400MS (400W) Modules with a combined STC rated dcoutput power of 10,800W. The modules are connected into 27 Enphase:IQ7A-72-2-US Microinverters. The inverter has electronic maximum power pointtracking to maximize energy captured by the PV modules. The inverter also has aninternal ground fault detection and interruption device that is set to disconnect thearray in the event that a ground fault that exceeds one ampere should occur. Theinverter has DC and AC disconnect integrated system and labels are provided asrequired by the National Electrical Code.When the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used tocontribute to the power requirements of the occupancy. If PV power meets therequirements of the loads of the occupancy, any remaining PV power is sold backto the utility. When utility power is available, but PV power is not available,building loads are supplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUNO Unless Noted OtherwiseVIF Verify In FieldWP Weather ProofBatteryBATUtility meterUMGPGeneration PanelMDPMain Distribution PanelSoladeckSDNAVD North American Vertical datumMicrogrid Interconnect DeviceMIDREVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590NOTES ANDDESCRIPTIONSymbols:Abbreviations:79.60"39.20"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE97UPLIFT PRESSURE, 2 RAILS75CANADIAN :CS1Y-400MS(400W) MODULES 99'-0"115'-0"99'-0"115'-0" 18'-0"28'-0"18'-0"50'-0"SDACDUMMDPCBREVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ROOF PLANA-01SCALE: 1/16" = 1'-0"1(N) SOLADECK (TYP.)ROOF PLAN WITH FIRE SETBACKAND PROPERTY LINESFIRE ACCESS AND PATHWAYSAS PER NFPA 11.12.2ECHO ST,3'-0" FIRE SETBACK3'-0" FIRE SETBACK EXISTINGDRIVEWAY1-STORYHOUSE3/4" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(N) ENPHASE IQ COMBINER BOX(N) ALTERNATIVE POWERSOURCE AC DISCONNECT(E) MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANEL(E) SERVICE POINT ANDUTILITY METERINGROOF #1(27) CANADIAN : CS1Y-400MS(400W) MODULES(N) (27) ENPHASE: IQ7A-72-2-USMICROINVERTERSDETACH STRUCTUREMODULES TO BE PLACEDAT LEAST 2 FT AWAY FROMALL THE ROOF EDGES 52'-0"71'-0"4'-0" TYP.REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590MODULE LAYOUTS-01SCALE: 3/32" = 1'-0"1MODULE LAYOUTGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SEAMS SHALL BE INSTALLED AS SHOWN INSHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 11' - 4"0' - 5"2' - 8"0' - 11"ZONE 1'XXXXZONE 2e1' - 4"0' - 5"2' - 8"0' - 11"ZONE 2n1' - 4"0' - 5"1' - 4"0' - 5"ZONE 2r1' - 4"0' - 5"1' - 4"0' - 5"ZONE 3e1' - 4"0' - 5"1' - 4"0' - 5"ZONE 3rN.A.N.A.1' - 4"0' - 5"MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 27 MODULESMODULE TYPE = CANADIAN : CS1Y-400MS (400W) MODULESMODULE WEIGHT = 49.82 LBS / 22.6 KG.MODULE DIMENSIONS = 79.60" x 39.20" = 21.67 SFUNIT WEIGHT OF ARRAY = 2.30 PSFARRAY AREA & ROOF AREA CALC'SROOFROOF TYPEARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZESEAMSPACING#1METAL585.061514.0038.6418.4°182°2"X4"16" O.C.LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)(E) BACK YARDSEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS(2) EXISTING RESIDENTIAL BUILDING HAVE 2"X4" SYP TRUSSES SPACED@ 24" O.C. AND METAL ROOF DECKS WITH MEAN ROOF HEIGHTS OF 15FT WITH SEAMS SPACED 16" O.C. EXISTING ROOF SLOPE FOR THESOLAR RETROFIT IS 18.4 DEGREES. CONTRACTOR TO FIELD VERIFYAND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXISTBETWEEN PLANS AND IN FIELD CONDITIONS.3. FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18"EACHWAY FROM HIPS AND VALLEYS PER NFPA 11.12.2 * I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED. CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERALAND UPLIFT FORCES AND EQUIPMENT DEAD LOADS. *(86) PV ROOF ATTACHMENT@ 16" & 32" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)ROOF #1TILT - 18.4°AZIM. - 182°(E) FRONT YARD(N) (27) ENPHASE: IQ7A-72-2-USMICROINVERTERS(N) IRONRIDGE XR-10 RAIL (TYP.)ROOF #1(27) CANADIAN : CS1Y-400MS(400W) MODULES 4'-0" TYP.12'-5"P3P4P5P69'-0"P1P27'-3"REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01.1COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590PARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: 1/8" = 1'-0"1ARTIAL RESSURE ANDMODULES EXOSURELEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)NOTE : PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.2h2DISTANCE : 1' - 0"0.5hDISTANCE : 7' - 6"- MISSING MODULEFOR EXPOSED MODULESFOR NON-EXPOSED MODULESALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS : 75 PSF(E) FRONT YARD2h2ROOF #1(27) CANADIAN : CS1Y-400MS(400W) MODULES(E) BACK YARD 6"NOTES:1 AVAILABLE IN MILL FINISH, AND BRONZEANODIZED FINISH2 STAINLESS STEEL LAG SCREWS INCLUDEDWITH ANODIZED FINISHUnits are Inches withmm in bracketsGeneral Notes:13.1482.00 [50.80]3.5413.26750.50 [12.70] 1.50 [38.10]0.84 [21.37]0.79 [20.07]0.83[21.1]1.10 [27.88]432196REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ATTACHMENT DETAILATTACHMENT DETAIL (FRONT VIEW)S-02SCALE - 1 1/2" = 1'-0"13/8-24 X 0.8" ROUND POINT SETSCREWMID CLAMPPV MODULEEND CLAMP(N) IRONRIDGE XR10 RAILS-5-N CLAMP(E) SNAP-LOCKSEAM 1" HIGHATTACHMENT DETAIL (FRONT VIEW)SCALE: 8" = 1'-0"S-02216" (TYP.) REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590STRUCTURECALCULATION REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ELECTRICALLINE DIAGRAMNOTE:1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017 INCLUDING MAXIMUM NUMBEROF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PERSTRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODELNUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, ASAPPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH NEC 312.8 IF PANELGUTTER SPACE IS INADEQUATE.3. IF THE FUSED AC DISCONNECT WIRE RUN EXCEEDS 10 FT FROMTHE POINT OF INTERCONNECTION, CABLE LIMITERS ORCURRENT-LIMITED CIRCUIT BREAKERS MUST BE INSTALLED FOREACH UNGROUNDED CONDUCTOR PER NEC 705.31.SOLAR ARRAY (10.800 kW-DC STC)(27) CANADIAN : CS1Y-400MS (400W) MODULES(03) BRANCHES OF 09 MODULES1ELECTRICAL LINE DIAGRAME-01SCALE: NTS(N) SOLADECK600V, NEMA 3RUL LISTEDL2L1NL2L1GN20A/2PG15A (N) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4)2-POLE BREAKERS AND ENVOYCOMMUNICATION GATEWAY]L2L120A/2PGGGGGGGGGG(3) #10 AWG THWN-2 - RED(3) #10 AWG THWN-2 - BLACKEGC #10 AWG THWN-2IN 3/4" IMC, RMC, FMC, LFMC,HDPE, NUCC, RTRC, LFNC,PVC, EMT, FMT OR ENTCONDUIT RUNGGGGGGGGG(3) #8 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNENPHASE: IQ7A-72-2-USMICROINVERTERSPV MODULESQ CABLES(E) MAIN BREAKER200A/2P, 240VL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NNEXISTINGGROUNDINGELECTRODESYSTEMBI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240VL1L2NTO UTILITY GRIDGGGGGGGGGL2L120A/2PL1L2NLINE TAP USING INSULATIONPIERCING PER NEC 705.12(A)(N) ALTERNATIVE POWERSOURCE AC DISCONNECT:240V, 60AMP RATED,NEMA 3R, UL LISTED LOCKABLE & FUSIBLEWITH 50A FUSESL2L1L2L1NNGG#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)(3) #6 AWG THWN-2IN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(E) MAIN SERVICEDISCONNECT/MAINDISTRIBUTION PANEL,200A RATED, 240V REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ELECTRICAL CALCULATIONELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.19.ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOFSURFACE.WIRING CALCULATIONSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION. ACDUMMDPCBACDUMMDPCBREVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590SYSTEM LABELINGRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECT(PER CODE: NEC 690.56(C)(3))LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 39.15 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60349A240A1.4520LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)DATA PER PANELTURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSWARNINGIN CASE OF EMERGENCY, CONTACT:GO SOLAR POWERPH. NO. : (800) 530-9597LABEL LOCATION:MAIN DISCONNECT(PER CODE: NFPA 11.12.2.1.5)LABEL LOCATION:PV BREAKER/AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)EMERGENCY RESPONDER:THIS SOLAR PV SYSTEM IS EQUIPPEDWITH RAPID SHUTDOWN.TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''POSITION TO SHUTDOWN ENTIRE PV SYSTEMLABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NFPA 1, 11.12.2.1)CAUTION:LABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NEC 690.56(B) AND NEC 705.10)POWER TO THIS BUILDING IS ALSOSUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATEDAS SHOWNPV SOLAR ARRAYON ROOF1008 ECHO ST, FORT PIERCE, FL 34982ENPHASE IQCOMBINER BOXALTERNATIVE POWERSOURCE AC DISCONNECTMAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANELSERVICE POINT ANDUTILITY METERINGPV SOLAR ARRAY1008 ECHO ST, FORT PIERCE, FL 34982ENPHASE IQCOMBINER BOXRAPID SHUTDOWNSWITCH/AC DISCONNECTMAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANELSERVICE POINT ANDUTILITY METERING REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-02COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-03COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-04COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERHEFFELFINGER RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-05COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1008 ECHO ST, FORT PIERCE, FL 34982 CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590DATA SHEET