HomeMy WebLinkAboutLETTER-ANALYTICAL RESULTSMr. Gary Mayfield April 23, 2019
Southeast Building Solutions, Inc.
104 Meco Lane
Oak Ridge, TN 37830
Account# 16700 Login# L476905
Dear Mr. Mayfield:
Enclosed are the analytical results for the samples received by our laboratory on April 16, 2019.
All samples on the chain of custody were received in good condition unless otherwise noted. When
possible, non-IOM samples will be retained for 14 days following the date of this report (unless an
extension is specifically requested). IOM samples are retained for 7 days.
Please contact client services at (888) 432-5227 if you would like any additional information regarding
this report. Thank you for using SGS Galson.
Sincerely,
SGS Galson
[qcsig]
Lisa Swab
Laboratory Director
Enclosure(s)
Page 1 of 8 Report Reference:1 Generated:23-APR-19 15:18
ANALYTICAL REPORT
Terms and Conditions & General Disclaimers
• This document is issued by the Company under its General Conditions of Service accessible at http://www.sgs.com/en/Terms-and-
Conditions.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein.
• Any holder of this document is advised that information contained herein reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not
exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the
fullest extent of the law.
Analytical Disclaimers
• Unless otherwise noted within the report, all quality control results associated with the samples were within established control limits or
did not impact reported results.
• Note: The findings recorded within this report were drawn from analysis of the sample(s) provided to the laboratory by the Client (or a
third party acting at the Client’s direction). The laboratory does not have control over the sampling process, including but not limited to
the use of field equipment and collection media, as well as the sampling duration, collection volume or any other collection parameter
used by the Client. The findings herein constitute no warranty of the sample's representativeness of any sampled environment, and
strictly relate to the samples as they were presented to the laboratory. For recommended sampling collection parameters, please refer to
the Sampling and Analysis Guide at www.sgsgalson.com.
• Unrounded results are carried through the calculations that yield the final result and the final result is rounded to the num ber of
significant figures appropriate to the accuracy of the analytical method. Please note that results appearing in the columns preceding the
final result column may have been rounded and therefore, if carried through the calculations, may not yield an identical final result to the
one reported.
• The stated LOQs for each analyte represent the demonstrated LOQ concentrations prior to correction for desorption efficiency (if
applicable).
• Unless otherwise noted within the report, results have not been blank corrected for any field blank or method blank data.
Accreditations SGS Galson holds a variety of accreditations and recognitions. Our quality management system conforms with the requirements
of ISO/IEC 17025. Where applicable, samples may also be analyzed in accordance with the requirements of ELAP, NELAC, or LELAP under one of the
state accrediting bodies listed below. Current Scopes of Accreditation can be viewed at http://www.sgsgalson.com in the accreditations section of
the "About" page. To determine if the analyte tested falls under our scope of accreditation, please visit our website or call Client Services at (888)
432-5227.
National/International Accreditation/Recognition Lab ID# Program/Sector
AIHA-LAP, LLC - IHLAP, ELLAP, EMLAP ISO/IEC 17025 and USEPA NLLAP Lab ID 100324 Industrial Hygiene, Environmental Lead,
Environmental Microbiology
State Accreditation/Recognition Lab ID# Program/Sector
New York (NYSDOH) ELAP and NELAC (TNI) Lab ID: 11626 Air Analysis, Solid and Hazardous Waste
New Jersey (NJDEP) NELAC (TNI) Lab ID: NY024 Air Analysis
Louisiana (LDEQ) LELAP Lab ID: 04083 Air Analysis, Solid Chemical Materials
Texas Texas Dept. of Licensing and
Regulation
Lab ID: 1042 Mold Analysis Laboratory license
Legend
< - Less than mg - Milligrams MDL - Method Detection Limit ppb - Parts per Billion
> - Greater than ug - Micrograms NA - Not Applicable ppm - Parts per Million
l - Liters m3 - Cubic Meters NS - Not Specified ppbv - ppb Volume
LOQ - Limit of Quantitation
ft2 - Square Feet
kg - Kilograms
cm2 - Square Centimeters
ND - Not Detected
in2 - Square Inches
ppmv - ppm Volume
ng - Nanograms
Account :
Login No. :
16700
L476905
Page 2 of 8 Report Reference:1 Generated:23-APR-19 15:18
LABORATORY ANALYSIS REPORT
Client : Southeast Building Solutions, Account No.: 16700
6601 Kirkville Road Site : Maverick Boats Login No. : L476905
East Syracuse, NY 13057 Project No. : V9023 Plant 2
(315) 432-5227 Date Sampled : 10-APR-19 Date Analyzed : 17-APR-19 - 18-APR-19
FAX: (315) 437-0571 Date Received : 16-APR-19 Report ID : 1129972
www.sgsgalson.com
Styrene
Air Vol Front Back Total Conc ppm
Sample ID Lab ID liter ug ug ug mg/m3
PP054 DERVE HULL L476905-5 24 2500 <20 2600 110 26
PP071 JOSH STRINGER L476905-6 24 2600 <20 2800 120 27
PP044 ROBERT DECK L476905-7 24 1400 <20 1500 62 15
PP065 LAZERO CHOP L476905-8 24 620 <20 660 27 6.4
PP017 BACKGROUND L476905-9 24 <20 <20 <21 <0.89 <0.21
COMMENTS:Please see attached lab footnote report for any applicable footnotes.
Level of Quantitation: 20. ug Submitted by: ARE Approved by: MLN
Analytical Method : mod. OSHA 89; GC/FID Date : 23-APR-19
Collection Media : 226-73 Supervisor : KAG
Page 3 of 8 Report Reference:1 Generated:23-APR-19 15:18
LABORATORY ANALYSIS REPORT
Client : Southeast Building Solutions, Account No.: 16700
6601 Kirkville Road Site : Maverick Boats Login No. : L476905
East Syracuse, NY 13057 Project No. : V9023 Plant 2
(315) 432-5227 Date Sampled : 10-APR-19 Date Analyzed : 22-APR-19
FAX: (315) 437-0571 Date Received : 16-APR-19 Report ID : 1130020
www.sgsgalson.com
Respirable Dust
Air Vol Total Conc
Sample ID Lab ID liter mg mg/m3
P731 BOOTH RESP L476905-3 1200 0.44 0.37
P1123 CHAMBER RESP L476905-4 1200 0.18 0.15
COMMENTS:Please see attached lab footnote report for any applicable footnotes.
Level of Quantitation: 0.050 mg Submitted by: PAH Approved by: SAP
Analytical Method : mod. NIOSH 0600; Gravimetric Date : 22-APR-19
Collection Media : PVC PW 37mm Supervisor : CMP
Page 4 of 8 Report Reference:1 Generated:23-APR-19 15:18
LABORATORY ANALYSIS REPORT
Client : Southeast Building Solutions, Account No.: 16700
6601 Kirkville Road Site : Maverick Boats Login No. : L476905
East Syracuse, NY 13057 Project No. : V9023 Plant 2
(315) 432-5227 Date Sampled : 10-APR-19 Date Analyzed : 20-APR-19
FAX: (315) 437-0571 Date Received : 16-APR-19 Report ID : 1129945
www.sgsgalson.com
Total Dust
Air Vol Total Conc
Sample ID Lab ID liter mg mg/m3
P960 CHAMBER TOTAL L476905-1 960 28 29
P646 BOOTH TOTAL L476905-2 960 11 11
COMMENTS:Please see attached lab footnote report for any applicable footnotes.
Level of Quantitation: 0.050 mg Submitted by: HVN Approved by: KRK
Analytical Method : mod. NIOSH 0500; Gravimetric Date : 23-APR-19
Collection Media : PVC PW 37mm Supervisor : CMP
Page 5 of 8 Report Reference:1 Generated:23-APR-19 15:18
LABORATORY FOOTNOTE REPORT
Client Name : Southeast Building Solutions, Inc.
Site : Maverick Boats
Project No. : V9023 Plant 2
6601 Kirkville Road
East Syracuse, NY 13057 Date Sampled : 10-APR-19 Account No.: 16700
(315) 432-5227 Date Received: 16-APR-19 Login No. : L476905
FAX: (315) 437-0571 Date Analyzed: 17-APR-19 - 22-APR-19
www.sgsgalson.com
L476905 (Report ID: 1129972):
Total ug corrected for a desorption efficiency of 94%.
SOPs: GC-SOP-16(20), GC-SOP-8(25), GC-SOP-12(15)
L476905 (Report ID: 1129972):
Accuracy and mean recovery data presented below is based on a 95% confidence interval (k=2). The estimated accuracy applies to the
media, technology, and SOP referenced in this report and does not account for the uncertainty associated with the sampling process.
The accuracy is based solely on spike recovery data from internal quality control samples. Where N/A appears below, insufficient
data is available to provide statistical accuracy and mean recovery values for the associated analyte.
Parameter Accuracy Mean Recovery
Styrene +/-12.9% 104%
L476905 (Report ID: 1130020):
SOPs: GRAV-SOP-5(21), GRAV-SOP-6(19)
Gravimetric analytical accuracy of the sampling media is 0.002 +/- 0.018 mg (average blank
weight change +/- 95% confidence interval or k=2). The estimated uncertainty applies to the media, technology, and
SOP(s) referenced in this report and does not account for any uncertainty associated with the sampling process.
PNOR = Particulates Not Otherwise Regulated.
L476905 (Report ID: 1129945):
SOPs: GRAV-SOP-5(21), GRAV-SOP-6(19)
Gravimetric analytical accuracy of the sampling media is 0.002 +/- 0.018 mg (average blank
weight change +/- 95% confidence interval or k=2). The estimated uncertainty applies to the media, technology, and
SOP(s) referenced in this report and does not account for any uncertainty associated with the sampling process.
PNOR = Particulates Not Otherwise Regulated.
NIOSH 0500 states "Do not exceed approximately 2mg dust loading on filter."
Page 6 of 8 Report Reference:1 Generated:23-APR-19 15:18
Page 7 of 8 Report Reference:1 Generated:23-APR-19 15:18
Page 8 of 8 Report Reference:1 Generated:23-APR-19 15:18