HomeMy WebLinkAboutEngineering I
I
Archiltectonto Inc
St:Lucie County.
Planning'&Developmtnt.Services
Building and Code Regulation Division
I
October 7,2021
i
M -10675 S':US HIGHWAY`1,Port`St.Lucie,FL
To Whom it May Con"'ern:
I
Our-office has performed-design pressure:caiculations for the above referenced project-and herby certify
that the proposed roll-up door is In compiiancevit6 the 2020'Florida Budding Code,160:mph wind zone,.
exposure"C",risk category IL
From Table 1609.3.1 ; V,tt= 160mph
From Table.16P9.60). 1U'h x 12'w door, 160 mph=+21.5,&--24 2
From Table 1609.7M. 15`mean roof height, Exposure C= 1.21
Required Design Pressures: 21.5-X 1.21=26.1
-24.2 X 1.21=29.3
i
Product:JanusInternational Group;LM,Series 3100,FLO2765 3
Product Pressures: +26.1&-29.3
'Oectfully Submit'
tchael eai,,AIA '
966 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce,`.Florida 34950. Fax; 772 460 4244 FL Reg#AA2660330 1 of 1.