HomeMy WebLinkAboutAPPROVED REVISION 2, WS LOT 43 - ENERGY CALCSFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EMERALD GOODMAN
Builder Name: KHOVNANAIN HOMES
Street: 5157 ARMINA PL
Permit Office:
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: EMERALD MODEL LOT 43 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 }
1. New construction or existing New (From Plans)
10. Wall Type42525.9 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Frame -Wood, Exterior
R=11.0 1180.70 ft2
3. Number of units, if multiple family 1
b. Concrete Block - Int Insul, Exterior
R=4.1 990.50 ft2
c. Frame - Wood, Adjacent
R=11.0 354.67 ft2
4. Number of Bedrooms 5
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1354.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1354.00 ft2
6. Conditioned floor area above grade (ft2) 2321
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(205.7 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.32 98.83 ft2
a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 275
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.32 64.75 W
13. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
45.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 42.08 ft2
SHGC: SHGC=0.34
Area Weighted Average Overhang Depth: 3.046 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.299
a. Electric Strip Heat
32.0 COPA.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 50 gallons
9. Floor Types (1354.1 sqft.) Insulation Area
EF:0.930
a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2
b. Conservation features
b. Floor over Garage R=19.0 386.00 ft2
None
c. NIA R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 72.67
Glass/Floor Area: 0.089
PASS
Total Baseline Loads: 74.13
I hereby certify that the plans and speci ations covered by
`Florida
Review of the plans and
s 87-
this calculation are in compliance with t Energy
specifications covered by this
Code.
calculation indicates compliance,,,,
'� ' - ;'w.�4 V
4with
the Florida Energy Code.
rr,;r,A•,; "O",b 0
PREPARED BY:
Before construction is completed
I
u
DATE:
this building will be inspected for
compliance with Section 553.908
t.
V
I hereby certify that this building, as designed, is in compliance
Florida Statutes.sy
'QD
with the Florida Energy Code.
�[1:
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-EMERALD GOODMA
Bedrooms: 5
Address Type:
Street Address
Building Type: User
Conditioned Area: 2321
Lot #
Owner Name: EMERALD MODEL LOT 43
Total Stories: 2
BlocklSubdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: KHOVNANAIN HOMES
Rotate Angle: 0
Street:
5157 ARMINA PL
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type: Detached
FL
NewlExisting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 2321
19341.6
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 EXTRA SUITE 144
1267.2 No
2
5
1
No
Yes
Yes
2 EX SUITE BATH 60
528 No
0
1
No
Yes
Yes
3 FOYER 133
1173 No
0
1
No
Yes
Yes
4 GRT DIN KITCHEN 630
5544 No
1
1
No
Yes
Yes
5 BED 4 174
1392 No
1
1
No
Yes
Yes
6 BED 3 167
1334 No
1
1
No
Yes
Yes
7 BED 2 162
1296 No
1
1
No
Yes
Yes
8 HALL LOFT 350
2800 No
0
1
No
Yes
Yes
9 LAUNDRY 48
384 No
0
1
No
Yes
Yes
10 MASTER SUITE 224
1792 No
2
1
No
Yes
Yes
11 MAST WIC 60
476 No
0
1
No
Yes
Yes
12 MASTER BATH 104
832 No
0
1
No
Yes
Yes
13 HALL BATH 65
518 No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Valve
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio EXTRA
SUITE 24 ft 0
144.8 ft2
-_-_
0 1
0
2 Slab -On -Grade Edge Insulatio EX SUITE
BATH 6 ft 0
60 ft2
_---
1 0
❑
3 Slab -On -Grade Edge Insulatio FOYER 20.5 ft 0
133.3 ft2
----
1 0
0
4 Slab -On -Grade Edge Insulatio GRT DIN
KITCHE 89 ft 0
530 ft2
----
0.25 0.5
0.25
10/912021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value Area
Joist R-Value
Tile Wood Carpet
5 Floor over Garage
BED 4 ---- ---- 174 ft2
19
0 0 1
6 Floor over Garage
BED 3 ---- ---- 167 ft2
19
0 0 1
7 Floor over Garage
HALL LOFT ---- ---- 45 ft2
19
0 0 1
ROOF
/
Roof Gable Roof Rad
Solar SA Emitt
Emitt Deck Pitch
1/ # Type
Materials Area Area Color Barr
Absor, Tested
Tested Insul. (deg)
1 Hip
Composition shingles 1466 ft2 0 ft2 Medium N
0.9 No 0.9
No 0 22.62
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RIBS
1
Full attic
Vented
150
1353 ft2
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
1
Under Attic (Vented)
BED 4
30
Blown
174 ft2
2
Under Attic (Vented)
BED 3
30
Blown
187 ft2
3
Under Attic (Vented)
BED 2
30
Blown
162 ft2
4
Under Attic (Vented)
HALL LOFT
30
Blown
350 ft2
5
Under Attic (Vented)
LAUNDRY
30
Blown
48 ftZ
6
Under Attic (Vented)
MASTER SUITE
30
Blown
224 ft2
7
Under Attic (Vented)
MAST WIC
30
Blown
60 ft2
8
Under Attic (Vented)
MASTER BATH
30
Blown
104 ft2
9
Under Attic (Vented)
HALL BATH
30
Blown
65 ft2
WALLS
Adjacent
Cavity
Space
Width
Height
1
E
Exterior Concrete Block
- Int InsEOXTRA SUIT
4.1
10
8 9
4
99.6 ft2
2
S
Exterior Concrete Block
- Int InsEaXTRA SUIT
4.1
11
8 10
0
116.7 ft2
3
S
Exterior Concrete Block
- Int InsEiK SUITE BA
4.1
5
5 10
0
54.2 ft2
4
E
Exterior Concrete Block
- Int lnsul FOYER
4.1
6
9 9
4
63.0 ft2
5
N
Exterior Concrete Block
- Int InsCURT DIN KIT
4.1
17
5 9
4
162.6 ft2
6
S
Exterior Concrete Block
- Int InsQRT DIN KIT
4A
16
2 10
0
161.7 ft2
7
W
Exterior Concrete Block
- Int InsGRT DIN KIT
4A
17
10 9
4
166.4 ft2
8
N
Exterior Frame - Wood
BED 4
11
13
8 8
10
120.7 ft2
9
E
Exterior Frame - Wood
BED 4
11
10
11 8
10
96A ft2
10
E
Exterior Frame - Wood
BED 3
11
10
11 8
10
96.4 ft2
11
E
Exterior Frame - Wood
BED 2
11
10
11 8
10
96.4 ft2
12
S
Exterior Frame - Wood
BED 2
11
12
3 8
10
108.2 ft2
13
N
Exterior Frame - Wood
HALL LOFT
11
7
3 8
10
64.0 ft2
IRCC
N
ing Frac Truss Type
0.1
Wood
0.1
Wood
0A
Wood
0.1
Wood
0.1
Wood
❑.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
Sheathing Framing
Solar
Below
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
10/9/2021 9:16 AM EnergyGauge@ USA 7.0,00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Owt
Adjacent
Tr) )A/all T)Jl-
Space Cavity Width
Height
Sheathing Framing
Solar Below
14 S
Exterior
Frame - Wood
HALL LOFT 11 12 9
8 10
112.6 ft2
0
0
0.5
a
0
15 N
Exterior
Frame - Wood
MASTER SUI 11 13 2
8 10
116.3 ft2
0
0
0.5
0
16 W
Exterior
Frame - Wood
MASTER SUI 11 14 7
8 10
128.8 ft2
0
0
0.5
0
17 W
Exterior
Frame - Wood
MASTER BA 11 11 10
8 10
104,5 ft2
0
0
0.5
0
18 S
Exterior
Frame - Wood
HALL BATH 11 10 0
8 10
88.3 ft2
0
0
0.5
0
19 W
Exterior
Frame - Wood
HALL BATH 11 5 5
8 10
47.8 ft2
0
0
0.5
0
20 E
Garage
Frame - Wood
FOYER 11 38 0
9 4
354.7 ft2
0
0
0.5
0
_21 W
Exterior
Concrete Block- Int InsORT DIN KIT 4.1 17 10
9 4
166.4 ft2
0
0
0.5
0
DOORS
#
Ornt
Door Type
Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
FOYER None
.39
3
6 8
20 ft2
2
E
Wood
FOYER None
.39
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID
Frame Panes
NFRC U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screeninc
1
E
1
Metal Double (Tinted)
Yes 0.32 0,27 N
16.2 ft2
1 ft 0 in
12 ft 0 in
None
None
2
W
7
Metal Double (Tinted)
Yes 0.32 0.3 N
24.1 ft2
1 ft 0 in
12 ft 0 in
None
None
3
W
21
Metal Double (Tinted)
Yes 0.55 0,34 N
42.1 ftz
11 ft 0 in
1 ft 0 in
None
None
4
E
9
Metal Double (Tinted)
Yes 0.32 0.27 N
16.2 ft2
1 ft 0 in
1 ft 0 in
None
None
5
E
10
Metal Double (Tinted)
Yes 0.32 0.27 N
16.2 ft2
1 ft 0 in
1 ft 0 in
None
None
6
E
11
Metal Double (Tinted)
Yes 0.32 0.27 N
16.2 ft2
1 ft 0 in
1 ft 0 in
None
None
7
N
13
Metal Double (Tinted)
Yes 0.32 0.3 N
16.2 ft2
1 ft 0 in
1 ft 0 in
None
None
8
S
14
Metal Double (Tinted)
Yes 0.32 0.3 N
16.2 ft2
1 ft 0 in
1 ft 0 in
None
None
9
W
16
Metal Double (Tinted)
Yes 0.32 0.3 N
32.4 ft2
1 ft 0 in
1 ft 0 in
None
None
10
W
7
Metal Double (Tinted)
Yes 0.32 0.3 N
10.0 ft2
1 ft 0 in
12 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
386
ft2 386
ft2 44 ft
8.8
ft
1
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) 00037
2255.9 123.76 232.35
.1694
7
10/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020
# System Type
1 Eiectric Strip Heat/
# System Type
1 Central Unit!
INPUT SUMMARY CHECKLIST REPORT
# System Type SubT
1 Eiectric None
FSEC
Cert # Company Name
None None
HEATING SYSTEM
Subtype
Speed Efficiency Capacity
Block
Ducts
None
COPA 32 kBtulhr
1
sys#1
COOLING SYSTEM
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
Split
Singl SEER: 16 45 kBtulhr 1350 cfm
0.74 1
sys#1
HOT WATER SYSTEM
Location
EF Cap Use SetPnt
Conservation
Garage
0.93 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
Collector
Storage
System Model # Collector Model # Area
Volume
FEF
ft2
DUCTS
/
---- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
# Location
R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic 6
275 ft2
HALL LOFT
1 ft2
Default Leakage
HALL LOFT (Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat:
Ceiling Fans:
CoolinJan
Heating [Xj Jan
]1Y
[X] Feb
]] Mar
[X] Mar
Apr
May
X
Jun
rl
rj
�X�
Oct
Oct
�Xj
Nov
Nov
Dec
Dec
Venting [[ ]] Jan
[[[ ]]]] Feb
[[X]] Mar
Apr
May
Jun Jul
Aug
Sep
Oct
lX1 Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (VVD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEN)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 58
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
EXTRA SUITE
Default(8 lbs/sq.ft.
ft2
ft
0.3
EX SUITE BATH
Default(8 Ibslsq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GIRT DIN KITCHEN
Default(8 Ibslsq.ft.
ft2
ft
0.3
BED 4
Default(8 Ibslsq.ft.
ft2
ft
0.3
BED 3
Default(8 Ibs/sq.ft,
ftz
ft
0.3
BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
HALL LOFT
10/9/2021 9:16 AM EnergyGauge@) USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST R
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft,
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER SUITE
Default(8 Ibslsq.ft.
ft2
ft
0.3
MAST WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sqft
ft2
ft
0.3
HALL BATH
10/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performa n ce Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.27
C. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
d U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. Floor over Garage
c. NIA
5157 ARMINA PL, FORT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Frame - Wood, Exterior
R=11.0
1130.70 ft2
b. Concrete Block - Int Insul, Exterior
R=4.1
990.50 ft2
1
C. Frame - Wood, Adjacent
R=11.0
354.67 ft2
5
d. NIA
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1354.00 ft2
2321
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
98.83 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT
6 275
64.75 ft2
13. Cooling systems
kBtuthr
Efficiency
42.08 ft2
a. Central Unit
45.0 SEER:16.00
ftz
3.046 ft,
0.299
Area
ft2
Insulation Area
R=0.0 968.10 ft2
R=19.0 386.00 ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Horne:
Date:
City1FL Zip:
kBtulhr Efficiency
32.0 COP:1.00
Cap: 50 gallons
EF: 0.93
Pstat
*Note: This is not a Building Energy Rating. if your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/9/2021 9:16 AAA EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1