HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
4 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Meth d
Project Name: Melissa Model II Builder Name:
Street: Permit Office: St. Lucie County
City, State, Zip: Port St. Lucie. FL , 34983 Permit Number.
Jurisdiction: St. Lucie County
Owner.
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41712.0 sqft.) Insulation Area
a. Concrete Block - Int Insul, Exterior R=4.1 1504.00
2
2. Single family or multiple family Detached
b. Frame - Wood, Adjacent R=11.0 208.00
2
3. Number of units, if multiple family 1
c. N/A R=
12
4
d. N/A R=
2
4. Number of Bedrooms
11. Ceiling Types (2148.0 sqft.) Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented) R=19.0 2148.00
6. Conditioned floor area above grade (ft2) 2148
R=
b. a. N/AN/A R=
Conditioned floor area below grade (ft2) 0
12. Ducts R
ft2
7. Windows(160.3 sgft.). Description Area
a. Sup: Attic, Ret: Attic, AH: Garage 6
5
a. U-Factor: Sgl, U=0.65 160.33 ft2
SHGC: SHGC=0.25
ft2
13. Cooling systems kBtumr Efficie
cy
b. U-Factor: NIA
a. Central Unit 45.0 SEER:16.)0
SHGC:
c. U-Factor: N/A ft2
SHGC:
14. Heating systems kBtu/hr Efficie
cy
Area Weighted Average Overhang Depth: 2.779 ft.
a. Electric Strip Heat 34.0 COP:1
30
Area Weighted Average SHGC: 0.250
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
Cap: 50 gailt
ns
SHGC(AVG): N/A
`
a. Electric
EF:0.
50
9. Floor Types (2148.0 sgft.) Insulation Area
R=0.0 2148.00 ft2
b. Conservation features
a. Slat -On -Grade Edge Insulation
b. N/A R= 2
R= ft2
None
16. Credits CF, P
tat
c N/A
Total Proposed Modified Loads: 60.19 PASS
/�1
Glass/Floor Area: 0.075 Total Baseline Loads: 60.56
I hereby certify that the plans and specifications covered by
Review of the plans and O it6 5
r�
this calculation are in compliance with the Florida Energy
specifications covered by this ,, _ ;
Code.
calculation indicates compliance
VA
with the Florida Energy Code.
PREPARED BY:
Before construction is completed r
DATE: 5-6-2021
this building will be inspected for
compliance with Section 553.908
I hereby certify that this ilding, as designed, is in compliance
Florida Statutes.,ro`�
CAD WIE
with the Florida Energy de.
OWNE E
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance quires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1:
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project quires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
�J 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Fjage 1 of 7
5/5/2021 6:50 PM I
■alml ■r 9-%1 ■ntlMwIMV nLlCAI-Wl IQT it?CDART
t-UKM K4U0-LULU
mry vvnn�■�+■� ■ v■ •._v■�..•�+ • — — -
PROJECT
Title:
Melissa Model II
Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 2148
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: Yes
PlatBook:
Builder Name:
Rotate Angle: 90
Street:
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State, Zip: Port
St. Lucie ,
FL,
34983
Family Type:
Detached
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design
Temp
Heating
Design I
ally Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days
Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2148
17184
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
1
Master Bedroom
178
1424 No
2
1
1
Yes
Yes
Yes
2
WIC 1
36
288 No
0
1
Yes
Yes
Yes
3
WIC 2
47
376 No
0
1
No
Yes
Yes
4
Pantry
12
96 No
0
1
No
Yes
Yes
5
Toilet
24
192 No
0
1
Yes
Yes
Yes
6
Master Bath
195
1560 No
1
1
Yes
Yes
Yes
7
Laundry
54
432 No
1
1
No
Yes
Yes
8
Bath
45
360 No
0
1
No
Yes
Yes
g
Dining Room
153
1224 No
2
1
Yes
Yes
Yes
10
Kitchen
216
1728 Yes
2
1
No
Yes
Yes
11
Living Room
342
2736 No
2
1
Yes
Yes
Yes
12
Foyer
50
400 No
0
1
Yes
Yes
Yes
13
Bedroom 2
240
1920 No
2
1
1
Yes
Yes
Yes
14
Bedroom 4
203
1624 No
2
1
1
Yes
Yes
Yes
15
WIC4
30
240 No
0
1
Yes
Yes
Yes
16
Bathroom
56
448 No
0
1
No
Yes
Yes
17
WIC 3
30
240 No
0
1
Yes
Yes
Yes
18
Bedroom 3
205
1640 No
2
1
1
Yes
Yes
Yes
19
Hall
32
256 No
0
1
No
Yes
Yes
5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
vK1nT D"RMuADV 1%UCt%V1 ICT DfrDADT
FORM r[4uJ-L000 �1�� V � V V nn�ru � •
� — � —
— -
FLOORS
# Floor Type
Space
Perimeter Perimeter R Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Master Bedroom
33 ft
178 ft2
—
1
0
0
2 Slab -On -Grade Edge Insulatio
WIC 1
6 ft
36 ft2
—
1
0
0
3 Slab -On -Grade Edge Insulatio
WIC 2
1 It
47 ft2
—
1
0
0
4Slab-On-Grade Edge Insulatio
Pantry
1 ft
12 ft2
—
1
0
0
5 Slab -On -Grade Edge Insulatio
Toilet
4 ft
24 ft2
—
1
0
0
6 Slab -On -Grade Edge Insulatio
Master Bath
lift
195 ft2
1
0
0
7 Slab -On -Grade Edge Insulatio
Laundry
1 ft
54 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulatio
Bath
1 ft
45 ft'
—
1
0
0
9 Slab -On -Grade Edge Insulatio
Dining Room
26 ft
153 ft2
—
1
0
0
10SIab-On-Grade Edge Insulatio
Kitchen
1 ft
216 ft'
____
1
0
0
11Slab-On-Grade Edge Insulatio
Living Room
lift
342 ft2
—
1
0
0
12SIab-On-Grade Edge Insulatio
Foyer
5 ft
50 ft2
1
0
0
13SIab-On-Grade Edge Insulatio
Bedroom 2
21 ft
240 ft2
1
0
0
14SIab-On-Grade Edge Insulatio
Bedroom 4
28 ft
203 ft2
__
1
0
0
15SIab-On-Grade Edge Insulatio
WIC4
5 ft
30 ft2
—
1
0
0
16Sfab-On-Grade Edge Insulatio
Bathroom
1 ft
56 ft2
1
0
0
17SIab-On-Grade Edge Insulatio
WIC 3
5 It
30 ft2
1
0
0
18SIab-On-Grade Edge Insulatio
Bedroom 3
33 ft
205 ft2
1
0
0
19SIab-On-Grade Edge Insulatio
Hall
1 ft
32 ft2
1
0
0
ROOF
Roof
Gable Roof
Rad
Solar SA Emitt
Absor. Tested
Tested
Emitt .D
In
ck Pitch
ul. (deg)
# Type Materials
Area
Area Color
Barr
1 Hip Composition shingles 2402 ft2
0 ft2 Medium
N
0.6 No 0.9
No
3 26.57
ATTIC
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
150
2148 ft2
N N
5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Ty
1
Under Attic (Vented)
Master Bedroom
19
Batt
178 ft2
0.1
Wood
2
Under Attic (Vented)
WIC 1
19
Batt
36 ft2
0.1
Wood
3
Under Attic (Vented)
WIC 2
19
Batt
47 ft2
0.1
Wood
4
Under Attic (Vented)
Pantry
19
Batt
12 ft2
0.1
Wood
5
Under Attic (Vented)
Toilet
19
Batt
24 ft2
0.1
Wood
6
Under Attic (Vented)
Master Bath
19
Batt
195 ft2
0.1
Wood
7
Under Attic (Vented)
Laundry
19
Batt
54 ft2
0.1
Wood
8
Under Attic (Vented)
Bath
19
Batt
45 ft2
0.1
Wood
9
Under Attic (Vented)
Dining Room
19
Batt
153 ft2
0.1
Wood
10
Under Attic (Vented)
IGtchen
19
Batt
216 ft2
0.1
Wood
11
Under Attic (Vented)
Living Room
19
Batt
342 ft2
0.1
Wood
12
Under Attic (Vented)
Foyer
19
Batt
50 ft2
0.1
Wood
13
Under Attic (Vented)
Bedroom 2
19
Batt
240 ft2
0.1
Wood
14
Under Attic (Vented)
Bedroom 4
19
Batt
203 ft2
0.1
Wood
15
Under Attic (Vented)
WIC4
19
Batt
30 ft2
0.1
Wood
16
Under Attic (Vented)
Bathroom
19
Batt
56 ft2
0.1
Wood
17
Under Attic (Vented)
WIC 3
19
Batt
30 ft2
0.1
Wood
18
Under Attic (Vented)
Bedroom 3
19
Batt
205 ft2
0.1
Wood
19
Under Attic (Vented)
Hall
19
Batt
32 ft2
0.1
Wood
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
0
_ 1 NE=>SE Exterior
Concrete Block - Int InsMaster Bedro
4.1
17
0
8
0
136.0 ft2
0
0
0.4
0
_ 2 NW=>NE Exterior
Concrete Block- Int InsMaster Bedro
4A
16
0
8
0
128.0 ft2
0
0
0.4
0
_ 3 NW=>NE Exterior
Concrete Block - Int Insul WIC 1
4.1
6
0
8
0
48.0 ft2
0
0
0.4
0
_ 4 NW=>NE Exterior
Concrete Block - Int Insul Toilet
4.1
4
0
8
0
32.0 ft2
0
0
0.4
0
_ 5 NW=>NE Exterior
Concrete Block - Int InsLMaster Bath
4.1
11
0
8
0
88.0 ft2
0
0
0.4
0
_ 6 NE=>SE Exterior
Concrete Block - Int Instli fining Room
4.1
17
0
8
0
136.0 ft2
0
0
0.4
0
_ 7 SE=>SW Exterior
Concrete Block - Int InsMining Room
4.1
9
0
B
0
72.0 ft2
0
0
0.4
0
_ 8 NE=>SE Exterior
Concrete Block - Int Insdiiving Room
4.1
11
0
8
0
88.0 ft2
0
0
0.4
0
_ 9 SW=>N Exterior
Concrete Block - Int Insul Foyer
4.1
5
0
8
0
40.0 ft2
0
0
0.4
0
_ 10 SW=>N Exterior
Concrete Block - Int InsuBedroom 2
4.1
15
0
8
0
120.0 ft2
0
0
0.4
0
11 NW=>NE Exterior
Concrete Block - Int InsuBedroom 2
4.1
6
0
8
0
48.0 ft2
0
0
0.4
0
_ 12 NE=>SE Exterior
Concrete Block - Int InsuBedroom 4
4.1
15
0
8
0
120.0 1`12
0
0
0.4
0
_ 13 SE=>SW Exterior
Concrete Block - Int InsuBedroom 4
4.1
13
0
8
0
104.0 ft2
0
0
0.4
0
_ 14 SE=>SW Exterior
Concrete Block - Int Insul WIC4
4.1
5
0
8
0
40.0 ft2
0
0
0.4
0
_ 15 SE=>SW Exterior
Concrete Block - Int Insul WIC 3
4.1
5
0
8
0
40.0 ft2
0
0
0.4
0
_ 16 SE=>SW Exterior
Concrete Block - Int InsuBedroom 3
4.1
15
0
8
0
120.0 ft2
0
0
0.4
0
_ 17 SW=>N Exterior
Concrete Block - Int InsuBedroom 3
4.1
15
0
S
0
120.0 1`12
0
0
0.4
0
_ IS NW=>NE Exterior
Concrete Block - Int InsuBedroom 3
4.1
3
0
8
0
24.0 ft2
0
0
0.4
0
_ 19 SE=>SW Garage
Frame - Wood Master Bath
11
14
8
112.0 ft
0.23
0.4
0
_20 SE=>SW Garage
Frame - Wood Laundry
11
6
8
48.0 ft2
0.23
0.4
0
21 SE=>SW Garage
Frame - Wood Bath
11
5
8
40.0 ft2
0.23
0.4
0
5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Pgge 4 of 7
�..,�^^nn IKIn11T 01 IUUADV I-U1=d _KI ICT RFPnIRT
r VRIVI R'YV.J�GVGV
•�■ V • VV•�••�•��•�• � �� � � --
WALLS
----
Adjacent
()Mt 10 VdAl
TVpe
Space
Cavity Width Height
Sheathing Framing Solar
Below
0
22 SW=>N Garage Frame - Wood
Foyer
11 1 8
8.0 ft2
0.23 0.4
0
DOORS
# Omt
Door Type
Space
Storms
U Value Ft
In
In
FHeight In
Area
1 SW=>N
Wood
Foyer
None
.39 3
6 10
0.5 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
# Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
3creening
1 NE=>SE 1 Metal
2 NW=>NE 4 Metal
3 NW=>NE 5 Metal
4 NE=>SE 6 Metal
5 SE=>SW 7 Metal
6 NE=>SE 8 Metal
7 SW=>NW 9 Metal
8 SW=>NW10 Metal
9 NE=>SE 12 Metal
10 SW=>NW17 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
30.0 ft2 1 ft 0 in
4.0 ft2 1 It 0 in
9.0 ft2 1 ft 0 in
30.0 ft2 1 ft 0 in
20.5 ft2 3 ft 0 in
15.0 ft2 8 ft 0 in
6.8 ft2 6 ft 0 in
15.0 ft2 1 ft 0 in
15.0 ft2 8 ft 0 in
15.0 ft2 1 ft 0 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 575 ft2
575 ft2
26 It
8 ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000254
1432 78.56 147.49 .0902
5
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
45 kBtu/hr
cfm
0.7 1
sys#1
5/5/2021 6:50 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Ptge 5 of 7
FORM R405-2020
INFU I ,UMMAKY VHtUKLI%') I KCrUKI
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95 50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
f2
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN RLF
eat Cool
1 Attic
6 105 ft2
Attic
30 ft2 Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling f Jan Feb
[X] Jan [X] Feb
[[ �Mar
M Mar
r [
r [
Or
]May' [X] Jun [XJ Jul
] May ] Jun I ] Jul
[X] Aug
I ] Aug[
[X] Sep
] Sepp
r Oct r 1
[ ] Oct [X]
Nov
Nov
Dec
Dec
Ventin IIII ]]]] Jan [[ II Feb
Venting
[[�Xll Mar
[)
May ]Jun [ ]Jul
[ ] Aug
[ ] Se
[[[Xxx]]] Oct [[[XXX]]]
Nov
Dec
Thermostat Schedule: •HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9 10
11
12
Cooling (WD) AM
PM
78
80
78 78
80 78
78 78 78
78 78 78
78
78
78
78
80 80
78 78
80
78
80
78
Cooling (WEH) AM
PM
78
78
78 78
78 78
78 78 78
78 78 78
78
78
78
78
78 78
78 78
78
78
78
78
Heating (WD) AM
PM
66
68
66 66
68 68
66 66 68
68 68 68
68
68
68
68
68 68
68 68
68
66
68
66
Heating (WEH) AM
PM
66
68
66 66
68 68
66 66 68
68 68 68
68
68
68
68
68 68
68 68
68
66
68
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Toilet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bathroom
515/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software P ge 6 of 7
FORM
F7
Z405-2020 INPUT SUMMARY CHECKLIST REPOK I
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. ft= ft 0.3 WIC 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3
nofn, iitm the/sn ft. ft2 ft 0.3 Hall
5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
7of7
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
, Port St. Lucie, FL, 34983
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
1504.00
2. Single family or multiple family
Detached
b. Frame - Wood, Adjacent
R=11.0
208.00
3. Number of units, if multiple family
1
c. N/A
R=
4. Number of Bedrooms
4
d. N/A
R=
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=19.0
2148.00
6. Conditioned floor area (ft2)
2148
b. N/A
R=
c. N/A
R=
7. Windows" Description
Area
12. Ducts, location & insulation level
R
a. U-Factor: S I, U=0.65
9
160.33 ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 1
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficient
c. U-Factor: NIA
ft2
a. Central Unit
45.0 SEER:16.
SHGC:
d. U-Factor. N/A
ft2
14. Heating systems
kBtu/hr
Efficient
SHGC:
a. Electric Strip Heat
34.0
COP:1.
Area Weighted Average Overhang Depth:
2.779 ft.
Area Weighted Average SHGC:
0.250
8. Skylights Description
Area
15. Hot water systems
Cap: 50 galk
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2148.00 ft2
Credits (Performance method)
CF, P:
b. NIA
R=
ft2
c. NIA
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final insp tion. Otherwise, a new EPL Display Card will be completed
based on installed Code c liant features.
Builder Signature: Date:
Address of New H e. TEN�) ,5W 1 h 2,1 City/FL Zip:
EKE
*Note: This is not a Building Energy Rating. If your Index is below 70. your home may qualify for energy efl
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 pf 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Melissa Model II Builder Name:
Street: Permit Office: St. Lucie County
City, State, Zip: Port St. Lucie, FL , 34983 Permit Number.
Y
w
Owner: Jurisdiction: St. Lucie County
=
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITI
-'-RIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame i
ialls
Walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cav
sealed.
with a material having a thermal resistance of
-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for frame
walls shall be installed in substantial contact E
id
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be install
d to
(including
insulation.
maintain permanent contact with the undersid
B of
above -garage
subfloor decking, or floor framing cavity insule
don
and cantilevered
shall be permitted to be in contact with the to
side
floors)
of sheathing, or continuous insulation installe
on
the underside of floor framing and extends fro
the
bottom to the top of all perimeter floor framin
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, in
ulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspc
ce wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or n
arrow
cavities shall be filled by insulation that on
Narrow cavities
installation readily conforms to the available c
avity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the buildin
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC ratE
d.
Plumbing and wiring
Batt insulation shall be cut neatly to fit arounc
wiring
and plumbing in exterior walls, or insulation tt
at on
installation readily conforms to available spac
extend behind oinino and wirin
e shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs s
lall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates nnfi walig or call 0 ngq-
a. In addition, inspection of log walls shall be in accordance wim tre provisions or JL;U-4uu.
5/5/2021 6:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page I of I