Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 4 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Meth d Project Name: Melissa Model II Builder Name: Street: Permit Office: St. Lucie County City, State, Zip: Port St. Lucie. FL , 34983 Permit Number. Jurisdiction: St. Lucie County Owner. Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41712.0 sqft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1504.00 2 2. Single family or multiple family Detached b. Frame - Wood, Adjacent R=11.0 208.00 2 3. Number of units, if multiple family 1 c. N/A R= 12 4 d. N/A R= 2 4. Number of Bedrooms 11. Ceiling Types (2148.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=19.0 2148.00 6. Conditioned floor area above grade (ft2) 2148 R= b. a. N/AN/A R= Conditioned floor area below grade (ft2) 0 12. Ducts R ft2 7. Windows(160.3 sgft.). Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 5 a. U-Factor: Sgl, U=0.65 160.33 ft2 SHGC: SHGC=0.25 ft2 13. Cooling systems kBtumr Efficie cy b. U-Factor: NIA a. Central Unit 45.0 SEER:16.)0 SHGC: c. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficie cy Area Weighted Average Overhang Depth: 2.779 ft. a. Electric Strip Heat 34.0 COP:1 30 Area Weighted Average SHGC: 0.250 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems Cap: 50 gailt ns SHGC(AVG): N/A ` a. Electric EF:0. 50 9. Floor Types (2148.0 sgft.) Insulation Area R=0.0 2148.00 ft2 b. Conservation features a. Slat -On -Grade Edge Insulation b. N/A R= 2 R= ft2 None 16. Credits CF, P tat c N/A Total Proposed Modified Loads: 60.19 PASS /�1 Glass/Floor Area: 0.075 Total Baseline Loads: 60.56 I hereby certify that the plans and specifications covered by Review of the plans and O it6 5 r� this calculation are in compliance with the Florida Energy specifications covered by this ,, _ ; Code. calculation indicates compliance VA with the Florida Energy Code. PREPARED BY: Before construction is completed r DATE: 5-6-2021 this building will be inspected for compliance with Section 553.908 I hereby certify that this ilding, as designed, is in compliance Florida Statutes.,ro`� CAD WIE with the Florida Energy de. OWNE E BUILDING OFFICIAL: DATE: DATE: - Compliance quires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1: - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project quires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). �J 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Fjage 1 of 7 5/5/2021 6:50 PM I ■alml ■r 9-%1 ■ntlMwIMV nLlCAI-Wl IQT it?CDART t-UKM K4U0-LULU mry vvnn�■�+■� ■ v■ •._v■�..•�+ • — — - PROJECT Title: Melissa Model II Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2148 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90 Street: Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Port St. Lucie , FL, 34983 Family Type: Detached New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design I ally Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2148 17184 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 178 1424 No 2 1 1 Yes Yes Yes 2 WIC 1 36 288 No 0 1 Yes Yes Yes 3 WIC 2 47 376 No 0 1 No Yes Yes 4 Pantry 12 96 No 0 1 No Yes Yes 5 Toilet 24 192 No 0 1 Yes Yes Yes 6 Master Bath 195 1560 No 1 1 Yes Yes Yes 7 Laundry 54 432 No 1 1 No Yes Yes 8 Bath 45 360 No 0 1 No Yes Yes g Dining Room 153 1224 No 2 1 Yes Yes Yes 10 Kitchen 216 1728 Yes 2 1 No Yes Yes 11 Living Room 342 2736 No 2 1 Yes Yes Yes 12 Foyer 50 400 No 0 1 Yes Yes Yes 13 Bedroom 2 240 1920 No 2 1 1 Yes Yes Yes 14 Bedroom 4 203 1624 No 2 1 1 Yes Yes Yes 15 WIC4 30 240 No 0 1 Yes Yes Yes 16 Bathroom 56 448 No 0 1 No Yes Yes 17 WIC 3 30 240 No 0 1 Yes Yes Yes 18 Bedroom 3 205 1640 No 2 1 1 Yes Yes Yes 19 Hall 32 256 No 0 1 No Yes Yes 5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software vK1nT D"RMuADV 1%UCt%V1 ICT DfrDADT FORM r[4uJ-L000 �1�� V � V V nn�ru � • � — � — — - FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bedroom 33 ft 178 ft2 — 1 0 0 2 Slab -On -Grade Edge Insulatio WIC 1 6 ft 36 ft2 — 1 0 0 3 Slab -On -Grade Edge Insulatio WIC 2 1 It 47 ft2 — 1 0 0 4Slab-On-Grade Edge Insulatio Pantry 1 ft 12 ft2 — 1 0 0 5 Slab -On -Grade Edge Insulatio Toilet 4 ft 24 ft2 — 1 0 0 6 Slab -On -Grade Edge Insulatio Master Bath lift 195 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio Laundry 1 ft 54 ft2 — 1 0 0 8 Slab -On -Grade Edge Insulatio Bath 1 ft 45 ft' — 1 0 0 9 Slab -On -Grade Edge Insulatio Dining Room 26 ft 153 ft2 — 1 0 0 10SIab-On-Grade Edge Insulatio Kitchen 1 ft 216 ft' ____ 1 0 0 11Slab-On-Grade Edge Insulatio Living Room lift 342 ft2 — 1 0 0 12SIab-On-Grade Edge Insulatio Foyer 5 ft 50 ft2 1 0 0 13SIab-On-Grade Edge Insulatio Bedroom 2 21 ft 240 ft2 1 0 0 14SIab-On-Grade Edge Insulatio Bedroom 4 28 ft 203 ft2 __ 1 0 0 15SIab-On-Grade Edge Insulatio WIC4 5 ft 30 ft2 — 1 0 0 16Sfab-On-Grade Edge Insulatio Bathroom 1 ft 56 ft2 1 0 0 17SIab-On-Grade Edge Insulatio WIC 3 5 It 30 ft2 1 0 0 18SIab-On-Grade Edge Insulatio Bedroom 3 33 ft 205 ft2 1 0 0 19SIab-On-Grade Edge Insulatio Hall 1 ft 32 ft2 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Absor. Tested Tested Emitt .D In ck Pitch ul. (deg) # Type Materials Area Area Color Barr 1 Hip Composition shingles 2402 ft2 0 ft2 Medium N 0.6 No 0.9 No 3 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2148 ft2 N N 5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Ty 1 Under Attic (Vented) Master Bedroom 19 Batt 178 ft2 0.1 Wood 2 Under Attic (Vented) WIC 1 19 Batt 36 ft2 0.1 Wood 3 Under Attic (Vented) WIC 2 19 Batt 47 ft2 0.1 Wood 4 Under Attic (Vented) Pantry 19 Batt 12 ft2 0.1 Wood 5 Under Attic (Vented) Toilet 19 Batt 24 ft2 0.1 Wood 6 Under Attic (Vented) Master Bath 19 Batt 195 ft2 0.1 Wood 7 Under Attic (Vented) Laundry 19 Batt 54 ft2 0.1 Wood 8 Under Attic (Vented) Bath 19 Batt 45 ft2 0.1 Wood 9 Under Attic (Vented) Dining Room 19 Batt 153 ft2 0.1 Wood 10 Under Attic (Vented) IGtchen 19 Batt 216 ft2 0.1 Wood 11 Under Attic (Vented) Living Room 19 Batt 342 ft2 0.1 Wood 12 Under Attic (Vented) Foyer 19 Batt 50 ft2 0.1 Wood 13 Under Attic (Vented) Bedroom 2 19 Batt 240 ft2 0.1 Wood 14 Under Attic (Vented) Bedroom 4 19 Batt 203 ft2 0.1 Wood 15 Under Attic (Vented) WIC4 19 Batt 30 ft2 0.1 Wood 16 Under Attic (Vented) Bathroom 19 Batt 56 ft2 0.1 Wood 17 Under Attic (Vented) WIC 3 19 Batt 30 ft2 0.1 Wood 18 Under Attic (Vented) Bedroom 3 19 Batt 205 ft2 0.1 Wood 19 Under Attic (Vented) Hall 19 Batt 32 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 NE=>SE Exterior Concrete Block - Int InsMaster Bedro 4.1 17 0 8 0 136.0 ft2 0 0 0.4 0 _ 2 NW=>NE Exterior Concrete Block- Int InsMaster Bedro 4A 16 0 8 0 128.0 ft2 0 0 0.4 0 _ 3 NW=>NE Exterior Concrete Block - Int Insul WIC 1 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _ 4 NW=>NE Exterior Concrete Block - Int Insul Toilet 4.1 4 0 8 0 32.0 ft2 0 0 0.4 0 _ 5 NW=>NE Exterior Concrete Block - Int InsLMaster Bath 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 _ 6 NE=>SE Exterior Concrete Block - Int Instli fining Room 4.1 17 0 8 0 136.0 ft2 0 0 0.4 0 _ 7 SE=>SW Exterior Concrete Block - Int InsMining Room 4.1 9 0 B 0 72.0 ft2 0 0 0.4 0 _ 8 NE=>SE Exterior Concrete Block - Int Insdiiving Room 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 _ 9 SW=>N Exterior Concrete Block - Int Insul Foyer 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 10 SW=>N Exterior Concrete Block - Int InsuBedroom 2 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 11 NW=>NE Exterior Concrete Block - Int InsuBedroom 2 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _ 12 NE=>SE Exterior Concrete Block - Int InsuBedroom 4 4.1 15 0 8 0 120.0 1`12 0 0 0.4 0 _ 13 SE=>SW Exterior Concrete Block - Int InsuBedroom 4 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 _ 14 SE=>SW Exterior Concrete Block - Int Insul WIC4 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 15 SE=>SW Exterior Concrete Block - Int Insul WIC 3 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 16 SE=>SW Exterior Concrete Block - Int InsuBedroom 3 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 _ 17 SW=>N Exterior Concrete Block - Int InsuBedroom 3 4.1 15 0 S 0 120.0 1`12 0 0 0.4 0 _ IS NW=>NE Exterior Concrete Block - Int InsuBedroom 3 4.1 3 0 8 0 24.0 ft2 0 0 0.4 0 _ 19 SE=>SW Garage Frame - Wood Master Bath 11 14 8 112.0 ft 0.23 0.4 0 _20 SE=>SW Garage Frame - Wood Laundry 11 6 8 48.0 ft2 0.23 0.4 0 21 SE=>SW Garage Frame - Wood Bath 11 5 8 40.0 ft2 0.23 0.4 0 5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Pgge 4 of 7 �..,�^^nn IKIn11T 01 IUUADV I-U1=d _KI ICT RFPnIRT r VRIVI R'YV.J�GVGV •�■ V • VV•�••�•��•�• � �� � � -- WALLS ---- Adjacent ()Mt 10 VdAl TVpe Space Cavity Width Height Sheathing Framing Solar Below 0 22 SW=>N Garage Frame - Wood Foyer 11 1 8 8.0 ft2 0.23 0.4 0 DOORS # Omt Door Type Space Storms U Value Ft In In FHeight In Area 1 SW=>N Wood Foyer None .39 3 6 10 0.5 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall # Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade 3creening 1 NE=>SE 1 Metal 2 NW=>NE 4 Metal 3 NW=>NE 5 Metal 4 NE=>SE 6 Metal 5 SE=>SW 7 Metal 6 NE=>SE 8 Metal 7 SW=>NW 9 Metal 8 SW=>NW10 Metal 9 NE=>SE 12 Metal 10 SW=>NW17 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 30.0 ft2 1 ft 0 in 4.0 ft2 1 It 0 in 9.0 ft2 1 ft 0 in 30.0 ft2 1 ft 0 in 20.5 ft2 3 ft 0 in 15.0 ft2 8 ft 0 in 6.8 ft2 6 ft 0 in 15.0 ft2 1 ft 0 in 15.0 ft2 8 ft 0 in 15.0 ft2 1 ft 0 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in None None None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 575 ft2 575 ft2 26 It 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1432 78.56 147.49 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 45 kBtu/hr cfm 0.7 1 sys#1 5/5/2021 6:50 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Ptge 5 of 7 FORM R405-2020 INFU I ,UMMAKY VHtUKLI%') I KCrUKI HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None f2 DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF eat Cool 1 Attic 6 105 ft2 Attic 30 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling f Jan Feb [X] Jan [X] Feb [[ �Mar M Mar r [ r [ Or ]May' [X] Jun [XJ Jul ] May ] Jun I ] Jul [X] Aug I ] Aug[ [X] Sep ] Sepp r Oct r 1 [ ] Oct [X] Nov Nov Dec Dec Ventin IIII ]]]] Jan [[ II Feb Venting [[�Xll Mar [) May ]Jun [ ]Jul [ ] Aug [ ] Se [[[Xxx]]] Oct [[[XXX]]] Nov Dec Thermostat Schedule: •HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 80 78 78 78 78 78 78 78 78 78 78 78 80 80 78 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 lbs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Room Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Living Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bathroom 515/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software P ge 6 of 7 FORM F7 Z405-2020 INPUT SUMMARY CHECKLIST REPOK I MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft= ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 nofn, iitm the/sn ft. ft2 ft 0.3 Hall 5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software 7of7 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. , Port St. Lucie, FL, 34983 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1504.00 2. Single family or multiple family Detached b. Frame - Wood, Adjacent R=11.0 208.00 3. Number of units, if multiple family 1 c. N/A R= 4. Number of Bedrooms 4 d. N/A R= 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=19.0 2148.00 6. Conditioned floor area (ft2) 2148 b. N/A R= c. N/A R= 7. Windows" Description Area 12. Ducts, location & insulation level R a. U-Factor: S I, U=0.65 9 160.33 ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 1 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficient c. U-Factor: NIA ft2 a. Central Unit 45.0 SEER:16. SHGC: d. U-Factor. N/A ft2 14. Heating systems kBtu/hr Efficient SHGC: a. Electric Strip Heat 34.0 COP:1. Area Weighted Average Overhang Depth: 2.779 ft. Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15. Hot water systems Cap: 50 galk a. U-Factor(AVG): N/A ft2 a. Electric EF: 0 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2148.00 ft2 Credits (Performance method) CF, P: b. NIA R= ft2 c. NIA R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final insp tion. Otherwise, a new EPL Display Card will be completed based on installed Code c liant features. Builder Signature: Date: Address of New H e. TEN�) ,5W 1 h 2,1 City/FL Zip: EKE *Note: This is not a Building Energy Rating. If your Index is below 70. your home may qualify for energy efl mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/5/2021 6:50 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 pf 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Melissa Model II Builder Name: Street: Permit Office: St. Lucie County City, State, Zip: Port St. Lucie, FL , 34983 Permit Number. Y w Owner: Jurisdiction: St. Lucie County = Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITI -'-RIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame i ialls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cav sealed. with a material having a thermal resistance of -3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for frame walls shall be installed in substantial contact E id continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be install d to (including insulation. maintain permanent contact with the undersid B of above -garage subfloor decking, or floor framing cavity insule don and cantilevered shall be permitted to be in contact with the to side floors) of sheathing, or continuous insulation installe on the underside of floor framing and extends fro the bottom to the top of all perimeter floor framin members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, in ulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspc ce wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or n arrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available c avity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the buildin shall be sealed to the finished surface. thermal envelope shall be air tight and IC ratE d. Plumbing and wiring Batt insulation shall be cut neatly to fit arounc wiring and plumbing in exterior walls, or insulation tt at on installation readily conforms to available spac extend behind oinino and wirin e shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs s lall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates nnfi walig or call 0 ngq- a. In addition, inspection of log walls shall be in accordance wim tre provisions or JL;U-4uu. 5/5/2021 6:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page I of I