HomeMy WebLinkAboutAPPROVED, HEAT LOADS(1)AFP Cabinets & Granite HVAC Load Analysis for AFP Cabinets & Granite 601 North 39th Street Fort Pierce, Florida Prepared By: Eric J. Svoboda, PE Fort Pierce Engineering, Inc. 315 South 7th Street Fort Pierce, FL 34950 772-672-4636 Thursday, January 21, 2021 Chvac - Full Commercial HVAC Loads Calculation Program Elite Software Development, Inc. Fort Pierce Engineering AFP Cabinets & Granite Fort Pierce, FL 34950 Page 2 General Project Data Input General Project Information Project file name:AFP Cabinets Heat Load.CH8 Project title:AFP Cabinets & Granite Designed by:Eric J. Svoboda, PE Project date:Monday, July 07, 2008 Weather reference city:FORT PIERCE, FLORIDA, USA Client name:AFP Cabinets & Granite Client address:601 North 39th Street Client city:Fort Pierce, Florida Company name:Fort Pierce Engineering, Inc. Company representative:Eric J. Svoboda, PE Company address:315 South 7th Street Company city:Fort Pierce, FL 34950 Company phone:772-672-4636 Company fax:772-672-4637 Barometric pressure:29.894 in.Hg. Altitude:25 feet Latitude:27 Degrees Mean daily temperature range:15 Degrees Starting & ending time for HVAC load calculations:7am - 10pm Number of unique rooms in this project:5 Building Default Values Calculations performed:Both heating and cooling loads Lighting requirements:2.00 Watts per square foot Equipment requirements:1.00 Watts per square foot People sensible load multiplier:250 Btuh per person People latent load multiplier:200 Btuh per person Room sensible safety factor:0 % Room latent safety factor:0 % Room heating safety factor:0 % People diversity factor:100 % Lighting profile number:0 Equipment profile number:0 People profile number:0 Building default ceiling height:10.00 feet Building default wall height:12.00 feet Internal Operating Load Profiles (C = 100) hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 C C C C C C C C C C C C C C C C C C C C C C C C 2 C C C C C C C C C C C C C C C C C C C C C C C C 3 C C C C C C C C C C C C C C C C C C C C C C C C 4 C C C C C C C C C C C C C C C C C C C C C C C C 5 C C C C C C C C C C C C C C C C C C C C C C C C 6 C C C C C C C C C C C C C C C C C C C C C C C C 7 C C C C C C C C C C C C C C C C C C C C C C C C 8 C C C C C C C C C C C C C C C C C C C C C C C C 9 C C C C C C C C C C C C C C C C C C C C C C C C 10 C C C C C C C C C C C C C C C C C C C C C C C C Z:\ ...\AFP Cabinets Heat Load.CH8 Thursday, January 21, 2021, 03:32 PM Chvac - Full Commercial HVAC Loads Calculation Program Elite Software Development, Inc. Fort Pierce Engineering AFP Cabinets & Granite Fort Pierce, FL 34950 Page 3 General Project Data Input (cont'd) Building-Level Design Conditions Design Month Outdoor Dry Bulb Outdoor Wet Bulb Indoor Rel.Hum Indoor Dry Bulb Grains Diff In/Outdoor Correction August 95 80 50%75 66.33 6 Winter 42 75 Master Roofs Roof No. ASHRAE Roof# Roof U-Fac Dark Color Susp. Ceil 1 1 0.033 No No Roof #1 Description: Metal Roof, R-30 Master Walls Wall No. ASHRAE Group Wall U-Fac Wall Color 1 C 0.095 D Wall #1 Description: Block wall, 8" sand & gravel, hollow core, siding exterior, interior finish, 1" extruded poly, R-5.0 Master Partitions Partition No. Partition U-Factor Cool T-D Heat T-D 1 0.095 10 10 Partition #1 Description: Block partition, 8" sand & gravel, hollow core, siding exterior, interior finish, 1" extruded poly, R- 5.0 Master Glass Glass No. Summer U-Factor Winter U-Factor Glass Shd.Coef. Interior Shading Interior Shd.Coef 1 0.810 0.830 1.000 1 0.550 Glass #1 Description: Default Glass Z:\ ...\AFP Cabinets Heat Load.CH8 Thursday, January 21, 2021, 03:32 PM Chvac - Full Commercial HVAC Loads Calculation Program Elite Software Development, Inc. Fort Pierce Engineering AFP Cabinets & Granite Fort Pierce, FL 34950 Page 4 Building Summary Loads Building peaks in August at 9am. Bldg Load Descriptions Area Quan Sen Loss %Tot Loss Lat Gain Sen Gain Net Gain %Net Gain Roof 2,003 2,181 6.40 0 1,475 1,475 1.90 Wall 2,194 6,878 20.17 0 3,344 3,344 4.32 Glass 222 6,081 17.84 0 18,186 18,186 23.48 Floor Slab 173 3,540 10.38 0 0 0 0.00 Skin Loads 18,680 54.79 0 23,005 23,005 29.71 Lighting 4,006 0 0.00 0 13,669 13,669 17.65 Equipment 2,003 0 0.00 0 6,835 6,835 8.83 Pool Latent 0 0 0.00 0 0 0 0.00 People 20 0 0.00 4,000 5,000 9,000 11.62 Partition 1,232 1,170 3.43 0 1,170 1,170 1.51 Cool. Pret.0 0 0.00 0 0 0 0.00 Heat. Pret.0 0 0.00 0 0 0 0.00 Cool. Vent.400 0 0.00 19,286 3,956 23,243 30.01 Heat. Vent.400 14,243 41.78 0 0 0 0.00 Cool. Infil.0 0 0.00 0 0 0 0.00 Heat. Infil.0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 521 521 0.67 Blow-Thru Fan 0 0 0.00 0 0 0 0.00 Reserve Cap.0 0 0.00 0 0 0 0.00 Reheat Cap.0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Return Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 34,093 100.00 23,286 54,156 77,442 100.00 Building Summary Sen Loss %Tot Loss Lat Gain Sen Gain Net Gain %Net Gain Ventilation 14,243 41.78 19,286 3,956 23,243 30.01 Infiltration 0 0.00 0 0 0 0.00 Pretreated Air 0 0.00 0 0 0 0.00 Room Loads 19,850 58.22 4,000 49,679 53,679 69.31 Plenum Loads 0 0.00 0 0 0 0.00 Fan/Duct/Misc Loads 0 0.00 0 521 521 0.67 Building Totals 34,093 100.00 23,286 54,156 77,442 100.00 Check Figures Total Building Supply Air (based on a 21° TD):2,175 CFM Total Building Vent. Air (18.39% of Supply):400 CFM Total Conditioned Air Space:2,003 Sq.ft Supply Air Per Unit Area:1.0859 CFM/Sq.ft Area Per Cooling Capacity:310.4 Sq.ft/Ton Cooling Capacity Per Area:0.0032 Tons/Sq.ft Heating Capacity Per Area:17.02 Btuh/Sq.ft Total Heating Required With Outside Air:34,093 Btuh Total Cooling Required With Outside Air:6.45 Tons Z:\ ...\AFP Cabinets Heat Load.CH8 Thursday, January 21, 2021, 03:32 PM Chvac - Full Commercial HVAC Loads Calculation Program Elite Software Development, Inc. Fort Pierce Engineering AFP Cabinets & Granite Fort Pierce, FL 34950 Page 5 Air Handler #1 - AHU 1 - Summary Loads Rm No Description Room Peak Time Area People Volume Htg.Loss Htg.CFM CFM/Sqft Sen.Gain Clg.CFM CFM/Sqft Lat.Gain S.Exh W.Exh Htg.O.A. Req.CFM Act.CFM Clg.O.A. Req.CFM Act.CFM 1 Granite Display Area 9am August 1,600 15 25,600 13,472 624 0.39 37,585 1,633 1.02 3,000 0 0 Direct 325 271 Direct 325 300 2 RR 1 9pm August 42 1 420 801 37 0.88 1,200 52 1.24 200 0 0 Direct 5 16 Direct 5 10 3 RR 2 6pm August 42 1 420 452 21 0.50 942 41 0.97 200 0 0 Direct 5 9 Direct 5 8 4 Kitchen Dispaly Area 9am August 187 2 2,992 2,593 120 0.64 5,608 244 1.30 400 0 0 Direct 38 52 Direct 38 45 5 Office 8am August 132 1 2,112 2,533 117 0.89 4,740 206 1.56 200 0 0 Direct 27 51 Direct 27 38 Room Peak Totals: Total Rooms: 5 Unique Rooms: 5 2,003 20 31,544 19,850 920 0.46 50,075 2,175 1.09 4,000 0 0 400 400 400 400 Z:\ ...\AFP Cabinets Heat Load.CH8 Thursday, January 21, 2021, 03:32 PM Chvac - Full Commercial HVAC Loads Calculation Program Elite Software Development, Inc. Fort Pierce Engineering AFP Cabinets & Granite Fort Pierce, FL 34950 Page 6 Air Handler #1 - AHU 1 - Total Load Summary Air Handler Description:AHU 1 Constant Volume - Proportion Supply Air Fan:Draw-Thru with program estimated horsepower of 0.21 HP Fan Input:0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio:0.93 --- This system occurs 1 time(s) in the building. --- Air System Peak Time:9am in August. Outdoor Conditions:Clg: 84° DB, 78° WB, 132.47 grains, Htg: 42° DB Indoor Conditions:Clg: 75° DB, 50% RH, Htg: 75° DB Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Room Space sensible loss:19,850 Btuh Infiltration sensible loss:0 Btuh 0 CFM Outside Air sensible loss: 14,243 Btuh 400 CFM Supply Duct sensible loss:0 Btuh Return Duct sensible loss:0 Btuh Return Plenum sensible loss:0 Btuh Total System sensible loss:34,093 Btuh Heating Supply Air: 19,850 / (.999 X 1.08 X 20) =920 CFM Winter Vent Outside Air (43.5% of supply) =400 CFM Room space sensible gain:49,679 Btuh Infiltration sensible gain:0 Btuh Draw-thru fan sensible gain:521 Btuh Supply duct sensible gain:0 Btuh Reserve sensible gain:0 Btuh Total sensible gain on supply side of coil:50,199 Btuh Cooling Supply Air: 50,199 / (.999 X 1.1 X 21) =2,175 CFM Summer Vent Outside Air (18.4% of supply) =400 CFM Return duct sensible gain:0 Btuh Return plenum sensible gain:0 Btuh Outside air sensible gain:3,956 Btuh 400 CFM Blow-thru fan sensible gain:0 Btuh Total sensible gain on return side of coil:3,956 Btuh Total sensible gain on air handling system:54,156 Btuh Room space latent gain:4,000 Btuh Infiltration latent gain:0 Btuh Outside air latent gain:19,286 Btuh Total latent gain on air handling system:23,286 Btuh Total system sensible and latent gain:77,442 Btuh Check Figures Total Air Handler Supply Air (based on a 21° TD):2,175 CFM Total Air Handler Vent. Air (18.39% of Supply):400 CFM Total Conditioned Air Space:2,003 Sq.ft Supply Air Per Unit Area:1.0859 CFM/Sq.ft Area Per Cooling Capacity:310.4 Sq.ft/Ton Cooling Capacity Per Area:0.0032 Tons/Sq.ft Heating Capacity Per Area:17.02 Btuh/Sq.ft Total Heating Required With Outside Air:34,093 Btuh Total Cooling Required With Outside Air:6.45 Tons Z:\ ...\AFP Cabinets Heat Load.CH8 Thursday, January 21, 2021, 03:32 PM