Loading...
HomeMy WebLinkAbout217835-2d Compaction signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net October 4, 2021 KSM JOB # :217835-2d/MR/jam CONTRACTOR:Coastal Construction of the Palm Beaches Joe Profeta 2336 SE Ocean Blvd, Ste 224 Stuart, Florida JOB LOCATION:Vero Beach Ocean Club 2495 Highway A1A Vero Beach, Florida PERMIT #: Respectfully, PE # 68366 10/04/21 Proudly Serving Florida since 1990 Email: joeprogc@comcast.net; islandvillagefb@gmail.com Certified Women Owned Business - WBE Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing To Whom it may concern, Enclosed, please find the nuclear density test results performed on the 2nd Lift of the Building Pad at the above referenced project. Should you have any questions, please feel free to contact our office. Julie E. Keller, P.E. President Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #:217835-2d/MR/jam NUC #234 Nuc Model:MC-DR Nuc Serial #:MD60308234 Vero Beach Ocean Club 2495 Highway A1A Vero Beach, Florida 2nd Lift of the Building Pad DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1 S.W.0" - 12"47 106.9 108.2 98.8% 2 S.E."48 107.5 "99.4% 3 Center "48 108.1 "99.9% 4 N.W."48 107.8 "99.6% 5 N.E."47 107.4 "99.3% Proctor Optimum Moisture: Proctor Max. Dry Density: P.C.F. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement 10/4/2021 Email: joeprogc@comcast.net; islandvillagefb@gmail.com 12.0% Julie E. Keller, P.E. President SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 DATE TESTED:October 1, 2021 In Place Moisture: PERMIT #: JOB LOCATION: Brown Sand CONTRACTOR:Coastal Construction of the Palm Beaches Proudly Serving Florida since 1990 Certified Women Owned Business - WBE 10.9% PE # 68366 for Unstaked Foundation 108.2 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting ITEM TESTED: Soil Description: TEST LOCATION OF SAMPLE Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :217835-2d/MR/jam PERMIT #: CONTRACTOR:Coastal Construction of the Palm Beaches JOB LOCATION:Vero Beach Ocean Club 2495 Highway A1A Vero Beach, Florida Soil Description: Brown Sand Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 108.2 Julie E. Keller, P.E. President PE # 68366 10/4/2021 SOIL COMPACTION REPORT ASTM D 1557 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Certified Women Owned Business - WBE Proudly Serving Florida since 1990 Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting October 1, 2021 103.0 104.0 105.0 106.0 107.0 108.0 109.0 110.0 7 8 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight