Loading...
HomeMy WebLinkAboutBlower Door Testt1ll.Ol%l ix fI I»nlmlT T"LETiN3U Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: j Job Information Builder: K Hovnanian Community: Lot: Address: I Unit: *A4, City: ,� State: FL Zip: House S.F. Avg. Ceiling Height. i t Total Volume: ?' / Air Leaks a Test Results Possing results must meet either the Performance, Prescriptive, or ERR Method OPRESCRIPTIVE AMETHOD The building or dwelling unit shall be tested and verified as having an air leakage rate or not exceeding 7 air change per hour at a pressure of 0.2�inch w.g, (50 pascals) in climate zones 1 and 2. PERFORMANCE OR ERI METHOD - The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R405-2017 (ERI), section labeled as infiltration, sub section ACH. ACH(50) specified on Form R405-2017WEnerrgy Calc (Performance) or R406-2017 (ERI); Pressure & Flow Data (For Single Point) Test # House Pressure: Pascals Flow: CFM (50) Ring Used '�7 ACH50 = CFM (50 60 / House Volume = � � L Method for calculating building volume: O Retrieved from architectural plans PASS ❑ FAIL Code Software calculated When ACH(50) is less than 3, Mechanical Ventilation installation must Field measured and calculated be verified by building department. Testing, Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0,2 inch w.g. (50 pascals). Testing shall be conducted by either individual as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489,105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official, Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Testing Company Company Name: RunBrook, LLC Phone: 561-510-5715 I hereby verify that the above Air Leaka resul -are in accordance with the 2017 61h Edition Florida Building Code Energy Conservation requiremen a rdin o he compliance method selected above. Signature of Tester: Date of Test: l Printed Name of Tester. Fr < Costagliola License/Certification #: 3243649 Issuing Authority: RESNET n C�REmEN F��.JIL:I"`al�1� ��JE� � TIr�"Clls� Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 201 / Florlda Building Code, Energy Conservation, 6L Edition System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems cfm25 Prescriptive Method cfm25 (total) To qualify as "substantially leak free" Qn must be less than or equal to 0,04 if air handler unit is installed, if air handler unit is not installed, Qn Total must be less than or equal to 0,03. This testing method meets the requirements in accordance with Section R403.3.3. 0 performance ! ERI Method cfm25 (Out or Total) To qualify using this method, Qn must not be greater than the proposed duct leakage Qn specified on Farm R405-2017 or R406-2017. = o �tin Total of all Tota Conditioned Leakage Ypc'selected on Form Qn specified on Form 17405-014 systems uare Footage R405-2017 (Energy Calc) or R406-2017 (Energy Calc) or 406-2017 ASS FAIL Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553,993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (1), Florida Statutes. Testing Company Company Company Name: RunBrook, LLC Phone: 561-510-5715 I hereby verify that the above duct leakage testing r is are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the com i ce method selected above. Signature of Tester: Date of Test: Loll Printed Name of Tester: Frank Costagliola