Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTEA Or BCIS Home R Log In 1 User Registration i Hot Topics Submit Surcharge 5tats & Facts Publications Contact Us BCIS Site Map Links Search #A Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL22853-R8 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer G.A.P. Roofing Address/Phone/Email 4444 Hunt Street pryor, OK 74361 (386)288-4583 dave.swaroopgap@gmaii.com Authorized Signature Dave Swaroop dave.swaroopgap@gmail.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL22853 R8 COI GAP17001.7 2020 FBC Eval Water -Guard final.pdf Standard Year ASTM D 1623 2017 ASTM D 1970 2015 TAS 103 2020 TAS 110 2000 UL1897 2012 Product Approval Method Method 1 Option D Date Submitted 03/31/2021 Date Validated 06/10/2021 Date Pending FBC Approval 04/06/2021 Date Approved 06/14/2021 Date Revised 08/12/2021 Summary of Products FL # Model, Number or Name Description 22853.1 i WaterGuard Rain & Ice Nominal 55-mil, ASTM D 1970 self -adhered underlayment Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL22853 R8 II GAP17001.7 2020 FBC Eval WaterGuard final.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL22853 R8 AE GAP17001.7 2020 FBC Eval WaterGuard f]nal.pdf Created by Independent Third Party: Yes j 22853.2 Self -Adhered MetalGuard Nominal 60-mil, ASTM D 1970 self -adhered underlayment HT ___]WaterGuard Limits of Use Installation Instructions I Approved for use in HVHZ: Yes FL22853 R8 II GAP17001.7 2020 FBC Eval WaterGuard Approved for use outside HVHZ: Yes final.pdr Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL22853 R8 AE GAP17001.7 2020 FBC Eval WaterGuard final,pdf Created by Independent Third Party: Yes 22853.3 WaterGuard Self -Adhered MetalGuard A one meter wide, nominal 60-mil, ASTM D 1970 self -adhered HT MW underlayment I Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL22853 R8 II GAP17001.7 2020 FBC Eval WaterGuard Approved for use outside HVHZ: Yes f]nal.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +0/-90 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL22853 R8 AE GAP17001.7 2020 FBC Eval WaterGuard final.pdf M Created by Independent Third Party: Yes 22853.4 WaterGuard Self -Adhered MetalGuard j Nominal 60-mil, ASTM D 1970 self -adhered underlayment Trax I Limits of Use �^ Installation Instructions Approved for use in HVHZ: Yes FL22853 R8 II GAP17001.7 2020 FBC Eva] WaterGuard Approved for use outside HVHZ: Yes final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports j FL22853 R8 AE GAP17001.7 2020 FBC Eva] WaterGuard 1 final pdf Created by Independent Third Party: Yes 22853.5 WaterGuard Self -Adhered TileGuard Nominal 80-mil, ASTM D 1970 self -adhered underlayment HT Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL22853 R8 II GAP17001.7 2020 FBC Eval WaterGuard Approved for use outside HVHZ: Yes final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +0/-90 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL22853 R8 AE GAP17001.7 2020 FBC Eval WaterGuard f4nal.pdf — I Created by Independent Third Party: Yes 22853.6 WaterGuard Self -Adhered TileGuard Nominal 80-mil, ASTM D 1970 self -adhered underlayment Ultra i Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-90 Other: See evaluation report for limits of use. Installation Instructions FL22853 R8 II GAP17001.7 2020 FBC Eval WaterGuard final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL22853 R8 AE GAP17001.7 2020 FBC Eva[ WaterGuard fina[.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coavrjght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: RR Credit Card Safe EVALUATION REPORT Manufacturer: Manufacturing Location Quality Assurance: SCOPE Registry No, 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, 7'" EDITION (2020) G.A.P. ROOFING, INC. 4444 Hunt Street Pryor, OK 74361 (800)880-9808 www.gaproofing.us Pryor, OK Keystone Certifications ,Inc. (QUA1824) Issued June 9, 2021 Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 7"' Edition (2020) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1507.1.1, 1507.3.3, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) GAPR-014-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) GAPR-018-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) GAPR-029-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) GAPR-030-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies (TST5878) GAPR-034-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies (TST5878) GAPR-034-02-01.1 TAS 103 2020 PRI Construction Materials Technologies (TST5878) GAPR-034-02-02 TAS 110 2000 PRI Construction Materials Technologies (TST5878) 1047T0001 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0004.1 TAS 110 2000 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1047T0011 TAS 110 2000 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1047T0012 TAS 110 2000 PRI Construction Materials Technologies (TST5878) 1047T0016 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0017 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0018.1 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1047T0029 ASTM D 1623 2017 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1047T0035 ASTM D 1623 2017 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1047T0046 UL1897 2012 ASTM D 903 1998(2010) GAP17001.7 FL22853-R8 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE G.A.P. ROOFING, INC. WaterGuard Underlayments WaterGuard WaterGuard Self -Adhered MetalGuard HT is a nominal 60-mil thick ASTM D 1970 self -adhered Self -Adhered underlayment constructed with a SBS polymer modified asphalt top coating and a non-abrasive MetalGuard HT UV stable, anti-skid polymer film. The product is supplied in 2 sq. rolls with nominal dimensions of 36-in, x 67-ft. Exposure on the roof deck shall be limited to a maximum 30 days. WaterGuard WaterGuard Self -Adhered MetalGuard HT MW is an ASTM D 1970, TAS 103, and FRSA/TRI Self -Adhered Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant self- MetalGuard HT adhered underlayment constructed with a SBS polymer modified asphalt top coating and a non- MW abrasive UV stable, anti-skid polymer film. The product is supplied in rolls having nominal dimensions of 39 3/8-in. x 66-ft. Exposure on the roof deck shall be limited to a maximum 180 days. Tiles shall be placed on battens for all roof slopes. WaterGuard WaterGuard Self -Adhered MetalGuard Trax is a nominal 60-mil thick ASTM D 1970 self - Self -Adhered adhered underlayment constructed with a dual SBS polymer formulation and a non -woven, high MetalGuard Trax temp, UV stable, anti-skid synthetic surface. The product is supplied in rolls having nominal dimensions of 36-in, x 67-ft. Exposure on the roof deck shall be limited to a maximum 120 days. WaterGuard WaterGuard Rain & Ice is a nominal 55-mil thick ASTM D 1970 self -adhered underlayment Rain & Ice constructed with a SBS polymer modified asphalt top coating and surfaced with a sand release agent. The product is supplied in 2 sq. rolls with nominal dimensions of 36-in x 67-ft. Exposure on the roof deck shall be limited to a maximum 30 days. WaterGuard WaterGuard Self -Adhered TileGuard HT is a nominal 80-mil thick ASTM D 1970, TAS 103, and Self -Adhered FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition TileGuard HT compliant self -adhered underlayment constructed with a dual SBS polymer formulation and a non -woven, high temp, UV stable, anti-skid polyester top surface. The product is supplied in 2 sq. rolls with nominal dimensions of 39 3/8-in x 66-ft. Exposure on the roof deck shall be limited to a maximum 180 days. The maximum roof slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles shall be placed on battens for roof slopes greater than 6:12. WaterGuard WaterGuard Self -Adhered TileGuard Ultra is a nominal 80-mil thick ASTM D 1970, TAS 103, Self -Adhered and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition self- TileGuard Ultra adhered underlayment constructed with a dual SBS polymer formulation and a non -woven, high temp, UV stable, polyester reinforced top surface. The product is supplied in 2 sq. rolls with nominal dimensions of 39 3/8-in x 66-ft. Exposure on the roof deck shall be limited to a maximum 30 days. The maximum roof slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles shall be placed on battens for roof slopes greater than 6:12. GAP17001.7 FL22853-R8 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK G.A.P. ROOFING, INC. WaterGuard Underlayments 1 5 TECHNICAL SERVICES, LLC PRODUCT APPLICATION Min. Roof Slope: 2:12 in accordance with the FBC Roof Deck: Plywood decks shall be in accordance with the FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Application: All underlayments shall be installed in accordance with the FBC and the manufacturer's installation requirements. Substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the substrate shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The WaterGuard underlayments shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the substrate. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with 4" headlaps (MetalGuard and Rain & Ice only) or 3" headlaps (TileGuard) and minimum 6" end laps staggered min. 6-ft.from preceding course. In the HVHZ, the WaterGuard underlayments shall be installed over one of more plies of ASTM D 226 Type II or ASTM D 2626 organic felt with minimum 4" headlaps and minimum 6" endlaps in accordance with FBC Section 1518.3. It is permissible to backnail the WaterGuard underlayments 12-inches o.c. within the headlaps (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min. Application 40°F and rising; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. Roof Coverings: All WaterGuard underlayments are permitted to be used with mechanically fastened metal roofing, slate shingles, asphalt shingles, photovoltaic shingles, and composite plastic shingles in accordance with the FBC. WaterGuard Self -Adhered MetalGuard HT MW is permitted to be used with mechanically fastened clay and concrete tiles set on battens only in accordance with the FBC. WaterGuard Self -Adhered TileGuard Ultra is permitted to be used with mechanically fastened clay and concrete tiles in accordance with the FBC. WaterGuard Self -Adhered TileGuard HT is permitted to be used with mechanically fastened clay and concrete roof tiles or clay and concrete roof tiles set in the following roof tile adhesive in accordance with the FBC. 1. DuPont TILE BONDTm Roof Tile Adhesive 2. DAP Touch'n Seal Storm Bond Roof Tile Adhesive 3. ICP Adhesives Polyset AH-160 GAP17001.7 FL22853-R8 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. RE E G.A.P. ROOFING, INC. WaterGuard Underlayments TECHNICAL SERVICES, LLC WIND RESISTANCE OF ROOF TILE UNDERLAYMENT SYSTEMS The Allowable Design Pressures below shall be used in accordance with the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition for the selected underlayment system. The Allowable Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. System No. 1 Direct Deck application Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WaterGuard Self -Adhered MetalGuard HT MW, WaterGuard Self -Adhered TileGuard Ultra or WaterGuard Self -Adhered TileGuard HT shall be self -adhered to the deck in accordance with manufacturer's installation instructions. The underlayment may be optionally backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1- 5/8-inch fd tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Allowable Design Pressure: -90 psf GENERAL LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 3) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 4) All headlaps shall be installed to shed water from the deck. 5) The underlayment may be used as described in other current FBC product approval documents. 6) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. GAP17001,7 FL22853-R8 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT G.A.P. ROOFING, INC. WaterGuard Underlayments The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 7`h Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. �;II►It)t �* No 74021 CC STATE OF : W O R �.O P N�,�� iiisSl0NA1-{fit`. 2021.06.09 10:18:21 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 ") )f E W CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT GAP17001.7 FL22853-R8 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.