HomeMy WebLinkAboutBuilding PlansA NEW CUST014 H014E FOR an %I LAZATHA MURPHT AIND JOHNI WILLIAMS JR INDEX OF DRAWINGS T DRPO, `NG TITUE" i UMBER 'R SHcET ANr DRAWING INDEX 'E FOUNDATION PLANS AND PLUMBING RISER to 3 t-LOOR PI ELECTRl(-AlL PLAN NOTIES AND MISC, -AN, lr----.LEVATI(DN 4 AND ROOF PLAN 5 CROS'S SEC-11110N 6 A ClXllll.,, A,� t2-Mr,,'fl TUR r ("I 1 AL, I A fl, N,, � ES , LSAN, DT 7 ""'RUSS C"ONNEC115(" R SCHEDULE A W Q_, ow Lu Z Lij a_ Ld C) < 0 6 LLJ Ld 2 uj L'i o) o L oW .0 L, 044 00 m Lu (b tL�,j 0 L'i a- Lo I 16 L2J x (C,)J) Y-:o - z Ld < Ld L L p U) m _j 0 Z z z 0 ljj (:5 (-) - Ld 6 6 _j 2 (f) . 0 ,n LL -1 0- Q� _, PROJECT NAME AND ADDRESS: _'o L LL i L9 MODEL 1545 3-BEDROOM FOR JOHN WILLIAMS JR. AND LAZATHA MURPHY PARCELL ID 1431-701-0023-000-6 DRAWN BY: C. PEARSON CHECKED BY: G. NEELY I START DATE: SEPT 2020 1 w0fial /CLIFF/PROJECT/RUTH 4 FOOTER 1/2"=1'—c. FOOTER 172 1,_a„ LOAD BEARING FOOTER 1 /2"=1 ' 03 Fn I I NI n ATI n NI NI nTFC 4" CONCRETE SLAB WITH 6X6 — 10/10 WWF OVER 6 MIL VAPOR BARRIER OVER CLEAN COMPACTED, & TERMITE TREATED FILL. 16"DX12"W FOOTING W/2#5 BARS CONT. AROUND. �3 8"WIDE X 8"DEEP THICKENED SLAB EDGE WITH 1—#5 REBAR CONT. �} 8"X8"X16" CONC. MASONRY UNITS WITH HORIZ. J JOINT REINF. AT 16" VERTICALLY FROM FTG. TO TIE BEAM HOOK BOTH ENDS 6" MIN. 4" PVC HVAC CHASE UNDER SLAB. COORDINATE LOCATION WITH MECHANICAL CONTRACTOR. 4" CONCRETE PAD FOR CONDENSING UNIT. COORDINATE LOCATION WITH MECHANICAL CONTRACTOR. DEPRESS ♦B x FOR SHOWER. MAINTAIN r SLAIll TWICI�ILIESS• BASIN. ()CONCRETE WALK ® CONC. DRIVE 10 1 #5 BAR FROM FOOTING TO TIE BEAM HOOK BOTH ENDS 6" MIN. 11 HOSE BIBB CONCRETE COMPLIANCE PARAGRAPH 1. ALL CONCRETE SHALL BE AS DESIGNED TO DEVELOP A COMPRESSIVE • THESE PLANS ARE CERTIFIED TO BE DESIGNED IN ACCORDANCE WITH 7TH EDITION OF THE 2020 FLORIDA BUILDING CODE STRENGTH AS FOLLOWS: FOUNDATIONS 2500 PSI RESIDENTIAL CODE, USING A FASTEST -MILE WIND VELOCITY OF 160 MPH. THIS ENGINEERING DESIGN IS FOR RESISTING WIND LOADS ON THIS PATICULAR RESIDENCE ON THIS SPECIFIC LOT, AND IS NOT VALID WITHOUT MY SIGNATURE 2. ALL REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO AND RAISED SEAL NOTES, THE WALL SECTIONS AND THE FLOOR PLAN(S). ASTM A-615 GRADE 40 3. ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED AND SPACED IN FORMS AND SECURED IN PLACE IN ROOF TRUSSES ACCORDANCE WITH THE PROCEDURES AND REQUIREMENTS OUTLINED IN • THE ROOF STRUCTURE CONSISTS OF PRE-ENGINEERED TRUSSES PLACED 24" O.C.. THE TRUSSES SHALL BE DESIGNED THE LATEST EDITION OF THE "BUILDING CODE REQUIREMENTS FOR "MANUALS AND ENGINEERED FOR 150 MPH WIND LOADS. FINAL TRUSS ENGINEERING SHALL INCLUDE UPLIFT FOR TRUSS GIRDERS, AND REINFORCED CONCRETE", ACI 318-95 AND THE OF STANDARD ACI ALL REGULAR TRUSSES THAT HAVE OVER 520 LBS. OF UPLIFT. IT SHALL ALSO INCLUDE ALL TRUSS BRACING REQUIREMENTS PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES", AND SHALL SPECIFY ALL GIRDER BUCKET LOADS. 315 LATEST EDITION. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FABRICATION. 4. ALL BAR SPLICES AND DOWELS SHALL LAP 25 BAR DIAMETERS UNLESS • FINAL ENGINEERING FROM THE TRUSS MANUFACTURER SHALL BE PROVIDED TO THE CONTRACTOR BEFORE WORK STARTS OTHERWISE NOTED. 6. CALCIUM CHLORIDE SHALL NOT BE USED IN ANY FORM. ROOF SHEATHING 7. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: • THE ROOF TRUSSES SHALL BE SHEATHED WITH 7/16" OSB OR 1/2" CDX PLYWOOD AND NAILED WITH 8d GUN NAILS @ 6" O.C. NAIL SHEATHING INTO GABLES 4" O.C. ALONG EDGES & 6" O.C. IN FIELD STRUCTURAL PART WHERE TRUSS OR ROOFING MANUFACTURER SPECIFICATIONS DIFFER FROM THESE, USE THE MORE STRINGENT. BRACE COVER MINIMUM CLEAR FOOTINGS, (CONCRETE CAST ALL TRUSSES PER TPI HIB-91 AGAINST AND PERMANENTLY UPLIFT CONNECTORS EXPOSED TO EARTH) 3 INCHES . ALL TRUSSES, EXTERIOR BEARING WALLS AND INTERIOR BEARING WALLS SHALL BE STRAPPED OR OTHERWISE CONNECTED WITH FOOTINGS AND WALLS A DIRECT LOAD PATH FROM THE TRUSS ALL THE WAY TO THE FOUNDATION. THIS INCLUDES THE CONNECTION BETWEEN (CONCRETE CAST IN THE TRUSS AND THE TOP PLATES, THE TOP PLATES TO STUDS, THE STUDS TO THE BOTTOM PLATE AND THE BOTTOM FORMS PERMANENTLY PLATE TO THE FOUNDATION. EXPOSED TO EARTH) 2 INCHES • USE THE FOLLOWING CONNECTORS (OR EQUAL CONNECTORS) TO RESIST THE TRUSS UPLIFT LOADS CATEGORIZED BELOW OR SLAP (IN CONTACT WITH EARTH) 2 INCHES USE THESE AS AN EXAMPLE. HOWEVER, TRUSS CONNECTORS SHALL RESIST A MINIMUM LATERAL LOAD OF 350 LBS.. BEAMS (TO STIRRUPS) 2 INCHES USE CONNECTOR STRENGHHS AND NAILING REQUIREMENTS 1N ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. COLUMNS (TO TIES) • TRUSSES ON EXTERIOR AND INTERIOR FRAME WALLS ABOVE GRADE 2 INCHES ALLOWABLE LOADS FOR "SIMPSON" CONNECTORS ARE BASED ON SPECIES II SOUTHERN YELLOW PINE LUMBER, IF SPECIES 8. UNLESS OTHERWISE PERMITTED OR SPECIFIED, THE CONCRETE SHALL BE III SPRUCE LUMBER IS USED INSTEAD OF S.Y.P. THEN ALL CONNECTOR STRENGTHS MUST BE MULTIPLIED BY .82 PROPORTIONED AND PRODUCED TO HAVE A SLUMP OF 3" MINIMUM AND MAXIMUM. IMMEDIATELY AFTER DEPOSITING, CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY MEANS OF MECHANICAL VIBRATION. HEADERS 9. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. PRE -CAST CONCRETE LINTEL MASONRY 1 1, HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N,TYPE 2 CONFORMING TO ASTM C90-0601, WITH 2 A MIN. NET COMPRESSIVE STRENGTH OF 1900 PSI (f'm = 1500 PSI) 3 2. CONCRETE BLOCKS SHALL CONFORM TO ASTM C 90 (28 DAY STRENGTH = 2000 PSI (NET AREA), F'm = 1500 PSI) LAID IN RUNNING BOND 4 WITH FULL MORTAR EMBEDMENT. 3. MORTAR SHALL BE TYPE M. 4. REINFORCE MASONRY WALLS VERTICALLY AS INDICATION ON APPLICABLE PLANS, DETAILS, SECTIONS, AND NOTES. CONCRETE FOR FILLED CELLS SHALL BE RODDED, VIBRATED, AND PUDDLED 5. DURING PLACEMENT TO ENSURE COMPLETE FILING OF THE BLOCK CORE. MORTAR BLOCK WEBS ON EITHER SIDE OF FILLED CELLS. 5. FILL ADDITIONAL MASONRY CELLS AT LOCATIONS AS SHOWN ON SECTIONS FOR ANCHORAGE OF DRILLED ANCHORS FOR ANGLES ETC. 6. FILL ONE CELL @ EACH JAMB FULL HEIGHT WITH GROUT AND ONE #5. 7. ALL VERTICAL REINFORCING STEEL BARS IN CMU WALLS SHALL BE ANCHORED IN THE CONCRETE THICKENED SLAB, FOOTING, OR BEAM (LINTEL) UPON WHICH THE WALL RESTS, AND IN THE BEAM AT THE TOP OF THE WALL WITH STANDARD HOOKS AND SHALL BE CONTINUOUS THROUGH ALL INTERMEDIATE WALL BEAMS, IF ANY. 8. ALL CMU REINFORCING STEEL BARS SHALL BE CONTINUOUS WITH LAP SPLICES OF AT LEAST 25 BAR DIAMETERS. 9 ALL VERTICAL REINFORCING SHALL BE PROVIDED AS INDICATED IN THE MASONRY WALL SCHEDULE AND SHALL BE INSTALLED AS FOLLOWS: PROVIDE CLEAN -OUT SPACE AT BOTTOM OF CELL TO BE REINFORCED AND FILLED (AT LOCATION OF REINFORCING STEEL DOWEL IN FOUNDATIONS OR PREVIOUS CONCRETE PLACEMENT) COMPLETELY CLEAN OUT AND FLUSH CELL TO BE FILLED IN INSTALL VERTICAL STEEL AND TIE TO DOWEL AT BOTTOM AND TIE IN PLACE AT TOP CLOSE CLEAN -OUT OPENING, AND FILL WITH 3000 PSI GROUT. 10. CONTINUOUS BOND BEAMS SHALL BE PROVIDED AS SHOWN ON THE CROSS SECTION. USE OPEN BOTTOM TYPE (KNOCK OUT) BOND BEAM UNITS AND USE WIRE MESH OR SMALL MESH METAL LATH UNDER BOND BEAM UNITS OVER CELLS NOT TO BE FILLED. 11. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 40. 12. PROVIDE CONTINUOUS 8 INCH DEEP BOND BEAM WITH ONE CONT. #5 AT THE BOTTOM OF THE WINDOWS, AND ABOVE THE LINTELS OVER BAR MASONRY OPENINGS AS WELL AS INDICATED ON THE PLANS, SECTIONS AND BLOCK NOTES. 13. ALL EXTERIOR BLOCK WALLS BETWEEN OPENINGS W/DOWNPOURS @ EACH END ARE SHEARWALLS. ALL STRUCTURAL & CONV. FRAMING LUMBER SHALL BE SPF STUD GRADE, OR BETTER, W/FRAME WALLS USINNG 2X4 STUDS AT 16" O.C. STUD GRADE, OR BETTER, W/FRAME WALLS USING 2X4 STUDS AT 16"' O.C. )TE: _UMBING RISER SHOWN TO SHOW INTENT ONLY NAL DESIGN IS TO MADE iA: I Exel KaTem., ----------- i 1 /2"=1 l_. TIMBER NOTES: 10. THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. STRUCTURAL LUMBER SHALL BE 2X4s SPF GRADE LUMBER. 11. DESIGN WIND LOAD: REFERENCE - ASCE 7-10 2x4 @16"O.C. STUDS SHALL BE USED FOR FRAME WALLS. WALLS SHALL BE ANCHORED WITH 1/2"DIA. WEDGE ANCHORS,41ONG SP.4' O.C. EXPOSURE B, IMPORTANCE FACTOR 1, INTERNAL PRESSURE COEF.=±.18 FOR ENCLOSED BUILDING WHEN MANUFACTURED WOOD CONNECTORS ARE USED, CONTRACTOR SHALL CATAGORY II FOLLOW THE MANUFACTURER'S RECOMMENDATIONS AS TO QUANTITY AND SIZE OF NAICS.ILDING ROOF DECKING SHALL BE 7/16" OSB OR 1/2" CDX PLYWOOD - BASIC WIND SPEED 150 MPH DECKING SHALL BE FASTENED PER THE SHEATHING FASTENING NOTE THIS SHEET. PRE-ENGINEERED TRUSS SUPPLIER SHALL PROVIDE ROOF TRUSS FRAMING LAYOUT -ROOF DESIGN LOADS: BY A FLORIDA REGISTERED ENGINEER. DEAD LOAD 17 PSF LIVE LOAD 20 PSF ANCHOR TRUSS TO FRAME WALL W/(2) SIMPSON HCDP ALL THE WAY DOWN BOTTOM PLATE TO SLAB W/1/2" WIDGETS @ 24" O.C. 12. FOUNDATIONS AND SLABS ON GRADE ARE DESIGNED TO BEAR ON SOIL WITH A MINIMUM SAFE BEARING CAPACITY OF 2000 PSF. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE REQUIRED CAPACITY UNDER ALL FOUNDATIONS AND SLABS. NOMINAL WIDTH QUANITY OF #5 REBAR @ BOTTOM OF LINTEL CAVITY. QUANTTY OF #5 REBAR @ TOP OF LINTEL CAVITY 8E16 — 1B/1T ZV NOMINAL HEIGHT F=FILLED WITH GROUT U=UNFILLED TO SEWER/SEPTIC PLUMBING RISER DIAGRAM NTS PRECAST LINTEL SCHEDULE APPLIED LOADS ON ALL PRECAST LINTELS HAVE BEEN REVIEWED TO INSURE THEY ARE WITHIN ALLOWABLE LIMITS. ALL UNITS ARE IN PLF LENGTH SAFE GRAVITY APPLIED GRRVITY SAFE UPLIFT APPLIED UPLIFT COMPOSIE BEAM REMARKS 1 2'-10" 6113 < 2000 4460 1 <1500 81`16 — 1 B/1T 1 X WINDOW 2 4'-6" 61 13 < 2000 2724 <1500 8F16 — 1 B/1T 30' WIN 3 5'-10" 4360 < 2000 2094 <1500 8F16 — 1 B/1T BEAM,�MIsc 3 -0 OPNG. 4 5'-10" 1451 < 1000 1207 <750 8F16 — 1 B/1T 3X WINDOW 30 DR SDLT 5 3'-6" 6113 < 2000 2093 <1500 8F16 — 1 B/1T 1/2 3 X WIN. 6 6'-6" 3480 < 2000 1880 <1500 8F16 — 1B/1T OR M®C 7 7'-6" 2661 < 2000 1438 <1500 8F16 — 1 B/1T 6' SGD OR 2X WINDOW 8 7'-6" 1011 < 755 560 <1500 8F16— 1 B/1T (2) 30" DOOR 9 4'-4" 5206 < 2000 2635 <1000 8F16— 1 B/1T 30 DR. 28' DOOR 10A 8'-4" 1843 < 1000 963 <750 8F16— 1B/1T 88' " 'GD S MISC 10 9'-4" 1843 < 1000 963 <750 8F16— 1 B/1T 8' SGD " MISC 11 10'-6" 1533 < 1000 777 <500 816 — 1B/1T (2)3X WNR 12 10'-6" 2781 < 2000 1239 <1000 8F24 - 1 B/1T 9' SGD OR (2)3X WIN 13 1 1'-4" 1366 < 2000 1028 <1000 8F16 — 1 B/1T 10' OPNG. 14 13'-4" 1075 < 750 521 <350 8F16 — 1 B/1T 12' SGD OR MISC 15 14'-0" 1002 < 750 481 <350 8F16 — 1 B/1 T 12'8" OPNG BEAM / MISC 16 17'-4" 1326 < 1000 422 <350 8F20 — 1 B/1T 16' OHD 17 19'-4" 1326 < 1000 458 <350 8F20 — 1B/1T 18' OHD 18 10'-4" 1533 < 1000 774 <650 8F20 — 1 B/1T 9' OHD CONC SLAB WAi wOC Uw c> wz � J Z rn W N W w r7 0 J W Z 00 a r" w c� 06 ww00dto00 zV)�ptJL_co ®w 00 >0 LLj w Cl) w co x co it <wpLLJN w Q z CD r �Ll(n07J� z < E Z Y z W U N avo0M C 3 Ii -1 a: 0_ .� PROJECT NAME AND ADDRESS: MODEL 1545 3—BEDROOM JOHN WILLIAMS JR. AND LAZATHA MURPHY FF ! ` PARCELL ID 1431-701-0023-000--6 -----------_— ----- �----- r RAWN BY: SHEET C. PEARSON CHECKED BY: G. EELY START DATE: SEPT a2o NON LOAD BEARING FOOTER 20 20 1 j2"= ► ,_a„ LATEST REV. DATE: FILE LOCATION: ,:/CUFF/PROJECT/RUTH SHEL--I=D.DWG 9-26— 18 7:58:01 pm EST I RANGE LAZY SUZAN A 12'-4" DBL. SINK DIN 14'-0" i N 2 CABINET ELEVATION SHOWN TO SHOW INTENT ONLY FINAL DESIGN BY CAB. MANUFACTURER. ELECTRICAL PLAN 1/4" = 1'-0" / TO FLOODS LIGHTS 4/0 ALUM. i� SER CABLE, 150 METER O J GROUND AMP I i 200 i PNL #4 Cu GRND MAIN �RKR. I � � 3#3,/0 THHN CU CABLE / GRND INTERSYSTEM ; ; ; IN 2" PVC CONDUIT BONDING ; ; GRADE I i i OPTIONAL !UNDERGROUND TO FLORIDA UNDERGROUND POWER & LIGHT i OPTIONAL I . I ----------- ELECTRICAL RISEN' CABINET ELEVATIONS 1/4" = 1'-0" Q REF PANTRY; 14'-O" C R.C.RECESSED INCANDESCENT Q 220 V. RECEPTACLE D.B.- DOOR BELL LIGHT FIXTURE (p 110 V. RECEPTACLE ® DOOR CHIME V.P. RECESSED INCANDESCENT D.C. VAPOR PROOF LIGHT FIXTURE RECEPTACLE TOP HALF SWICHED CEILING MOUNTED ® ELEC ELECTRICAL PANEL INCANDESCENT LIGHT FIXTURE a PNL TELEPHONE JACK PD HANGING PENDANT Qj JUNCTION BOX �--c A.L. INCANDESCENT LIGHT FIXTURE ® CHANDELIER OR �-C LOCATED IN ATTIC GFI GROUND FAULT INTERUPTER i HANGING LT. E.F. EXHAUST FAN WP WEATHER PROOF N❑-1 CABLE TELEVISION JACK S LIGHT SWITCH (� WALL MOUNTED 3 S THREE-WAY SWITCH DISCONNECT Y INCANDESCENT LIGHT FIXTURE FS-6-1 WALL MOUNTED SMOKE DETECTOR SG DIMMER SWITCH CEILING FAN WITH sD CEILING MOUNTED SMOKE DETECTOR )F.L. FLOOD LIGHTS O O LIGHT MOTION DETECTOR G.D.O. GARAGE DOOR OPENER 2'X4' FLOU. GENERAL LOAD WATTS AMPS WIRE TOTAL WATTS GENERAL LIGHTING 1545 TOTAL S.F. AND RECEPTACLES 3 PER SQ. FT. 20 12 4,635 APPLIANCE CKT. (5) 1,500 PER APPL. 20 12 7,500 REFRIGERATOR 1,600 PER UNIT 20 12 1,600 RANGE 12,000 PER UNIT 50 8 12,000 DISHWASHER 1,200 PER UNIT 20 12 1,200 DISPOSAL 500 PER UNIT 20 12 500 DRYER 5,000 PER UNIT 30 10 5,000 WASHER 1,600 PER UNIT 20 12 1,600 WATER HEATER 4,500 PER UNIT 30 10 4,500 SPRINKLER PUMP 4,500 30 10 4,500 SUB -TOTAL 43,035 1st 10,000 WATTS @ 100 % 10,000 REMAINDER WATTS @ 40 % 13,214 AIR CONDITIONER @ 10,000 WATTS 10,000 TOTAL WATTS 33,214 I TOTAL WATTS - 33,125/240 V. =138 AMPS 150 AMPS j LCTRICAL GENERAL DOTES 1. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND LOCAL & STATE REGULATIONS. COMPLY WITH THE LOCAL UTILITY REQUIREMENTS FOR SERVICE CONNECTIONS. 2. ALL EXTERIOR CONDUIT SHALL BE PVC SCH 80. INTERIOR CONDUIT SHALL BE EMT. 3. SEAL AREAS AROUND CONDUITS THAT PENETRATE WALLS. ALL WALL SURFACES SHALL BE REPAIRED AND PAINTED TO MATCH THE EXISTING SURFACE. CUT, PATCH, CAULK, AND SLEEVE AS REQUIRED WHERE NEW ITEMS PASS THROUGH FLOORS, WALLS OR CEILINGS. 5. PULL BOXES SHALL BE FURNISHED & INSTALLED WHERE NECESSARY IN THE CONDUIT SYSTEM TO FACILITATE CONDUCTOR INSTALLATION. CONDUIT RUNS LONGER THAN 100 FEET OR WITH MORE THAN THREE 90 DEGREE BENDS SHALL HAVE A PULL BOX INSTALLED AT A CONVENIENT INTERMEDIATE LOCATION. 6. ALL NEW ELECTRICAL COMPONENTS SHALL HAVE NEW NAMEPLATES INSTALLED. 7. ALL DIMENSION AND CONDUIT ROUTING SHALL BE FIELD VERIFIED PRIOR TO INSTALLATION OF EQUIPMENT. 8. ALL ELECTRICAL EQUIPMENT OR EQUIPMENT WITH ELECTRICAL CIRCUITS SHALL BE GROUNDED IN ACCORDANCE WITH NFPA 70 ARTICLE 250. ALL ELECTRICAL EQUIPMENT AND ENCLOSURES, RACEWAYS, AND HVAC EQUIPMENT SHALL BE EFFECTIVELY GROUNDED TO ENSURE PERSONNEL SAFETY. ALL NONCURRENT CARRYING METALLIC PARTS SHALL BE GROUNDED. THE EQUIPMENT GROUNDING CONDUCTOR SHALL BE BONDED TO ALL ENCLOSURES AND BOXES WHICH IT TERMINATES IN OR PASSES THROUGH. AN INSULATED GREEN EQUIPMENT GROUND WIRE SHALL BE INSTALLED IN ALL CONDUITS. WATERPIPES OR METAL STRUCTURES ENTERING A BUILDING FROM THE OUTSIDE SHALL BE GROUNDED . 9. PROVIDE TELEPHONE OUTLETS AT THE LOCATIONS INDICATED ON THE 10. PROVIDE PANEL SCHEDULE TO CONFORM WITH THIS O J 0 v r.� Q cu ;� j = ua 06 0 - _a -� > w> 21, 0 0.. C4 0 � ><�, �a) o 0 _ coo cn QL U) Qj 001 m o mv CD 00zI M _ Q l� L N S� O U o oo o0 o M u o O o N 00 r— 000 II o o r4 ¢o 42) ® z 0 o 0 0 w� U w w U Z � J w Z N \�itp``ti' ��Rfrri W w J lit Y,j`"' • •/ `�I LAJ a \� •'• �. wW00d Off_ ow ' ,�?`Z �, O ti.' _j Z�OIJitD ¢N =LL1:w �� f£:� o W w (3 w L'jap 00 : u- : a• Cl. o UJ (D z . Q w O 0 N z CD Q w p u jf;�ifill* W Q PROJECT NAME AND ADDRESS: MODEL 1545 3—BEDROOM FOR JOHN WILLIAMS JR. AND LAZATHA MURPHY PARCELL ID 1431-701-0023-000-6 C. PEARSON SHEET G. NEELY FHEKE EPT 2020 DATE: FILE LOCATION: C./CLIFF/PROJECT/RUTH SheI—fD.dwa (9—?f9-1(9 1 •._�7•.-�n nm FqT ATTIC VENTILATION CALCULATION MAXIMUM TOTAL HOUSE SQUARE FOOTAGE: 1604 SQ. FT. E� MAXIMUM REQUIRED ATTIC VENTING (1 /150): 1604 X 144 / 150 = 1539 SQ.INCHES MINIMUM PROVIDED VENTILATED SOFFIT: 96 LIN. FT. ® 10 SQ. IN. /LIN. FT. =960 SQ. INCHES. MINIMUM PROVIDED OFF RIDGE VENTS: 4 UNITES @ 140 SQ. IN. / UNIT =560 SQ. INCHES. TOTAL MINIMUM PROVIDED VENT AREA: 1520 SQ. IN, WINDOW AND DOOR DESIGN PRESSURE (PSF) (ENCLOSED) OPENING WALL ZONE 4 WALL ZONE 5 SIZE (OA 19) ±36.9 39.3 -46.4 B +35.5 +35.5 (20-49) -37.9 -43.7 c +33.9 +33.9 (50-99) -36.3 -40.5 D +32.7 +32.7 (=100<) -35.1 -38.0 STUCCO EXTERIOR CEMENT PLASTER, LATHE, FLASHING & STUCCO STOP SHALL COMPLY WITH ASTM C 926 & ASTM C 1063. STUCCO OVE SHEATHED WOOD IS A THREE COAT SYSTEM W/ MINIMUM PLASTER THICKNESS OF 7/8". LATHE SHALL BE NAILED OVER TWO LAYERS 15# FELT OR HOUSEWRAP. STUCCO OVER MASONRY IS A TWO COAT SYSTEM W/MINIMUM PLASTER THICKNESS OF 1 /2" PROVISION FOR DRAINAGE MUST BE PROVIDED AT THE BOTTOM OF STUCCO WALL COVERING. (NOT FOR MASONRY WALLS) A STUCCO CONTROL JOINT WITH WEEPS SHALL BE INSTALLED G WHERE DISSIMILAR BASE MATERIALS MEET, SUCH AS WOOD FRAME CONSTRUCTION OVER FIRST STORY MASONRY. COMPLIANCE PARAGRAPH THESE PLANS ARE CERTIFIED TO BE DESIGNED IN ACCORDANCE WITH 6TH EDITION OF THE 2017 FLORIDA BUILDING CODE RESIDENTIAL CODE, USING A FASTEST -MILE WIND VELOCITY OF 150 MPH. THIS ENGINEERING DESIGN IS FOR RESISTING WIND LOADS ON THIS PATICULAR RESIDENCE ON THIS SPECIFIC LOT, AND IS NOT VALID WITHOUT MY SIGNATURE AND RAISED SEAL NOTES, THE WALL SECTIONS AND THE FLOOR PLAN(S). RIO�-TTTDE E­1LEYATION ,f 0 .m LEFT SIDE ELEVATION 1/4" = 1„-0., j>-O" 10' — 0' FRONT ELEVATION 1/4" = 1'-O" j +38.9 +37.1 --41.5 A O —39.6 i j ROOF PLAN 1/81, = 1'-0" Wly- Uw w vz _1 rn W z N w a w LLJ Z d } nwN o 0 L­U) w w ��Zwco0o � CE m Wo z w w W xdN W Z Q ocn� wm dzU �WU UOZ �UOf() -i : PROJECT NAME AND ADDRESS: N b O U w w w w w v Q O <11 MODEL 1545 3-BEDROOM FOR JOHN WILLIAMS JR. AND LAZATHA MURPHY PARCELL ID 1431--701-0023-000— DRAWN BY: SHEET C. PEARSON CHECKED BY: G. NEELY START DATE: SEPT 2020 LATEST REV. DATE: /CLIFF/PROJECT/RUTH SHE-EV.DWG 9--20--18 7:59:28 pm EST PR[CAS MASONF STUCCO APPROX. .~".`'^' /oux/zvv uumu. r/u. W/9#5 BARS CONT. T/P. PROVIDE ASPHALT SHINGLE! R-30 B/0T INSULATION HURRICANE STRAP AS UPLIFT PRECAST LINTEL W/1#5 BAR LINTEL BLOCK BEAM YV BARS CONTINUOUS POi 8°X8°X16"CONC. MASON WITH HORIZONTAL JOINT 18" O.C. VERTICALLY. 16"DX12"N CONC. FTG. W/2#5 BARS CONT. /L - U-Iz - r _Q r) Q Q QT-1 r TTr) TT r2-'� CROSS SECTION �-30 INSULATION IROVDE ASPHALT SHINGLES OVER 15# -ELT ON 1/2' THK. PLYWOOD SHEATHING PRE—ENGINEERED WOOD TRUSSES @ |NDOS@c DOORS SHALL BE ANCHORED TO MASONRY OPENING W/3/16' TAPCON EMBEDDED 1 1/4" MIN. STUCCO FINISH ` " THK BATT |NSUL BETWEEN P.T. )BL LINTEL BLOCK BEAM / 3ARS CONTINUOUS POURED SOLID. FASCIA VENTED SOFFIT PRECAST LINTEL W/1#5 BAR MASONRY BEYOND STUCCO FINISH APPROX. FINISH 04 Lu cn W60— PROJECT NAME AND ADDRESS: MODEL 1545 3-BEDROOM FOR AND DRAWN BY: SHEET C. PEARSON CHECKED BY: G. NEELY START DATE: SEPT 2020 LATEST REV. DATE: FILE LOCATION: WEDGE ANCHOR I.L.O. J—BOLT NOTE GENERAL PLAN NOTES: G1 DESIGN PARAMETERS A) DESIGN LOADS: UNLESS NOTED OTHERWISE (UNO) IN SPECIFIC NOTES 1) ROOF LOADS: LIVE LOAD (LL): 20 PSF (25% DURATION INCREASE) DEAD LOAD (DL): 17 PSF SINGLE; 25 PSF TILE UPLIFT CALCS: DEAD LOAD (DL): 10 PSF SHINGLE; 16 PSF TILE (60% DURATION INCREASE). FLOOR LOADS: DL: 15psf ; LL: 40psf (0% DURATION INCREASE) G2 MIN. LUMBER SIZES, SPACES, GRADES, AND SPECIES (UNO IN SPECIFIC NOTES). A) INTERIOR NON -BEARING WALLS: 2x4 STUDS AT 24" ON CENTER. SPRUCE -PINE -FIR (SPF) GRADED LUMBER (OR BETTER) OR METAL STUDS. CRIMPER MAY BE USED IN LIEU OF SCREWS FOR METAL STUDS. B) FRAME BEARING WALLS: SPF #2 (MIN) 2x4 STUDS AT 16" ON CENTER TO 10'-0", USE 2X6 OVER 10'-0". C) HEADERS: SOUTHERN PINE, GRADE 2, (2) 202's LINO ON PLAN OR DETAILS. NAIL PLIES WITH 10d GUN NAILS AT 3" EDGES AND 6" INTERM. G3 HEADERS MAY BE CUT OR NOTCHED AT THE ENDS ONLY. OTHERWISE THEY SHALL NOT BE REDUCED IN STRENGTH. G4 LUMBER EXPOSED TO WEATHER OR CONTACTING CONCRETE OR STEEL SHALL BE PRESSURE TREATED (P.T.). G5 FRAMING CONTRACTOR IS RESPONSIBLE FOR TEMPORARY BRACING DURING ERECTION OF TRUSSES AND FOR ALL PERMANENT BRACING PER HIB-91 SUMMARY SHEET (AKA: 'THE ORANGE SHEET') G6 GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL, STRUCTURAL, ELECTRICAL, AND MECHANICAL WORK FOR ANCHORED, EMBEDDED, AND SUPPORTED ITEMS, WHICH AFFECT STRUCTURAL INTEGRITY. NOTIFY ENGINEER OF ANY DISCREPANCIES IMMEDIATELY PRIOR TO ANY CONTINUATION OF WORK. G7 ANCHOR POSITIONS ARE ± 1 /2" G8 7/16" OSB WITH APA STRUCTURAL RATING OF 24/16 MAY BE USED IN LIEU OF 15/32" PLYWOOD AS SHOWN ON PLANS. G9 ONLY SHINGLES AND FASTENERS FROM THE BUILDING DEPARTMENTS' LATEST APPROVED ROOF COVERING MANUFACTURERS LIST (IF APPLICABLE) SHALL BE USED. TESTING DATA FOR FASTENERS SHALL BE PROVIDED UPON REQUEST. G10 ALL STEEL REINFORCING IS GRADE 40 U.N.O. ON PLANS G11 ALL CONNECTORS SHALL BE NAILED PER MANUFACTURE'S SPECS. GENERAL NOTES FOR SHEAR WALL CONSTRUCTION: GSW1 ALL EXTERIOR BLOCK WALLS BETWEEN OPENINGS WITH DOWNPOURS AT EACH END ARE SHEARWALLS. A 1 /2" DIA. X 6" LONG MINIMUM WEDGE ANCHOR MAY BE USED IN LIEU OF 1 /2" DIA. J-BOLTS. ANCHORS TO BE LOCATED NO CLOSER THAN 5" TO EDGES AND 6" FROM CORNERS AND ENDS. USE APPROVED EPDXY SYSTEM AT CONCRETE CORNERS. DOWEL ROD REPAIR NOTES: IN THE EVENT STEEL HAS BEEN INADVERTENTLY OMITTED FROM DOWN POUR LOCATIONS. DRILL 5" INTO CONCRETE (NO CLOSER THAN 3 3/4" FROM EDGES AND 5" FROM ENDS OF CAP WALLS) REMOVE DUST PER MANUFACTURE'S INSTRUCTIONS AND USE 2 PART EPDXY TO ANCHOR 45 REBAR IN PACE. USE EITHER SIMPSON OR HII_Ti r 100 EPDXY T!F NOTE TO A/C CONTRACTOR: PASSIVE A/C RETURNS SHALL BE ADDED TO ALL ROOMS REQUIRED BY CODE WITH AN A/C SUPPLY. NOTE TO PLUMBER: L PLUMBING SHALL COMPLY WITH 6TH EDITION 2017 FBC PLUMBING . NOTE TO ELECTRICIAN: 1. SMOKE DETECTORS ARE TO BE LOCATED IN EACH BEDROOM AND COMMON AREA. 2. SMOKE DETECTORS SHALL BE WIRED TO COMPLY WITH NFPA 72. Z _ BATHROOM SHALL_ HAVE GFI RECEPTACLE RT18112 CONDITION #1: STRAP IS 0" TO 3/8" AWAY FROM EDGE OF TRUSS. REPAIR: NO REPAIR NECESSARY. CONDITION #2: STRAP IS 3/8"" TO 1-1/2" AWAY FROM EDGE OF TRUSS. REPAIR: PLACE MAXIMUM 2x4 BLOCK BETWEEN TRUSS AND STRAP. BEND PER DETAIL AND NAIL 7-10d. CONDITION #3: STRAP IS MORE THAN 1-1/2" AWAY FROM EDGE OF TRUSS. \ REPAIR: PER DETAIL SHOWN USING HUGHES RT18112 ANCHORED TO WALL WITH (3) 1/4"x2-1/4" �. (MIN.) TAP -CONS AND NAILED TO TRUSS �\ K(3) WITH 7-10d. MAXIMUM 1200 LBS. UPLIFT. 1/4" X 2-1 /4" TAP -CONS APPLIES TO MULTIPLES AND CONSECUTIVE TRUSSES, AND MAY BE USED ON EITHER SIDE OF WALL NOTE TO BUILDER: ALLOWANCE TOLERANCES SPACING AS FOLLOWS: J-BOLT..............± 2" O.C. DOWNPOURS ...... ± 8" O.C. REDHEAD NOTE: WEDGITS = WEDGE ANCHORS. WEDGITS REFERED TO IN DRAWINGS ARE REDHEADS AND ARE RATED AT 9690 POUNDS OF PULLOUT AND 7240 SHEAR PER REDHEAD MANUFACTURER DATA. STANDADI� REPAIR FOR SF )P MISALIGNMENT N'l 'S FOOTING AS PER FOUNDATION PLAN #5 DOWEL WITH 25" OVERLAP- GARAGE GOAL POST DETAIL i T t:: ALL TRUSS TO HEADER CONNECTIONS ARE (2) USP HCDP's U.N.O. (2) 2x8 SYP— SEE / CORNER DETAIL CORNER JACK 2x8 HEADER (PITCH CUT END) ENTRY SECTION NTS SHUTTER TRACKS, ANCHOR W/ 1/4 DIA. TAPCONS @ 12" O.C. OR PER MANUF. SPECIFICATIONS. 2" "H" HEADER PT 1x4 DOOR BUCK STRIPS - ANCHOR TO BLOCK WITH 3/16" TAPCON 1 1/4" MIN ENGAGEMENT INTO MASONRY. 2" STORM PANELS 0.05GA MILL FINISH -SMOOTH 14 1/4- WIDE SHUTTER TRACKS, ANCHOR W/ 1/4" DIA. TAPCONS @ 12" O.C. OR PER MANUF. SPECIFICATIONS. WING NUT 2"X2" STUDDED ANGLE WINDOW/DOOR AND HURRICANE SHUTTER ANCHOR DETAIL _. NTS 8d GUN NAILS AT 8d GUN NAILS AT 4" O.C. WITHIN 48" 6" O.C. ON JOINTS MINIMUM OF EDGES, AND EDGES AND 12" GABLES, & RIDGES r IN FIELD I— 15/32" PLYWOOD C-D OR 7/16" APA RATED OSB TYPICAL NAILING SCHEDULE 2x4 CAT BETWEEN TRUSSES STRAP TO HEADER WITH RT18112 NAILED 16-10d SEE ELEVATIONS u 1) 2x8 SYP. TA 18 BY USP — SEE TYPICAL WALL SEE FOUNDATION PLAN FOR SIZE AND REINFORCEMENT SEE ELEVATION FACE NAIL FULL TO JACK WITH GUN NAILS AT O.C. STAGGERE EL.± (0'-0") TOP SLAB, FTG P.C. LINTEL a PT 1x4 DOOR BUCK w STRIPS - ANCHOR TO c„ BLOCK WITH 3/16" TAPCON 1 1/4" MIN I ! ENGAGEMENT INTO l MASONRY. L J L NOTE: TAPCON SHALL BE THROUGH PRE DRILLED HOLES IN WINDOW FRAME INTO MASONRY. DOOR SIZE #TAPCONS LOCATION 2'-8" 14 A-F 3'-0" 14 A-F 1-12" SIDELIGHT 14 A-F 2-12" SIDELIGHT 14 A-F 5'-0" FRENCH DOOR 18 A-G 6'-0" FRENCH DOOR 18 A-G �Ty F� G G F A -- EQUAL B E EQUAL C C EQUAL D C EQUAL E E F� G G F 4„ /_USP TP4X ---\ SEE CONN. SCHED. STUD 10d D 2 6" MAX TYP. 2-2x8 LL DGIT W/ 2"WASHER PT(2X4) 0 _ I Cv USP RT18112 FULL STUD JACK STUD (2X4) SPF G #2 Q 16" O.C. USP TP4X o I N c, N r G 711 EXISTING SLAB P.T. (2x4) CONT. SEE CONNECTOR SCHEDULE 1/2" DIA x 10" MINIMUM J-BOLT OR 32" MAX. 6" WEUVE ANCHOR WI I H 2"' DIA WASHER INTERIOR BEARING WALL / BEARING WALL TO MASONY WALL CONNECTION pmw4o ol w� U w w U z Lo _ W W ww�� a o�_ o z �o_0 �, �`" o� 0 wF-�oL-10 §o W a pwwnua 1 8W,� Li Xo00 w wth� z � W (If�' QwowN w In V) m pR� z -i a .Q—z^_ U0L'i z w U z ciI -i L0C, ; PROJECT NAME AND ADDRESS: MODEL 1545 3—BEDROOM FOR JOHN WILLIAMS JR. AND LAZATHA MURPHY 4 PARCELL ID 1431-701-0023-000-6 DRAWN BY: SHEET C. PEARSON CHECKED BY: G. NEELY START DATE: SEPT 2020 LATEST REV. DATE: :/CLIFF/PROJECT/RUTH SHE—LWS2.DWG 9-26-18 7:17:09 pm ESTup I