HomeMy WebLinkAboutBlower door test - Creekside Lot 78Duct Leakage Test Report
Prescriptive or Performance Method
Job Information
Builder: DRHORT�I
Community: CREEK ID Lint:78
Address
Unit:
City; FORT PIERCE
State: FL`'
Duct Leakage Test Results
>Presciptive Method Performance Method
I
System 2
system 3 cfm25
Sum of any addi€ional
of all systems
72 = 2602 = 0.02 € n
Total of all systems
PASS
Total Conditioned
Square Footage
[�] FAIL
Testing Company
D Prescriptive Method cfm25 (total)
T-o qualify as "substantially leak free" Qn must be less than or equal to 0.04
if air handier unit is installed. if air handier unit is not installed, Qn Total
must be less than or equal to 0.03. This testing method meets the
requirements in accordance with Section R403.2.2
Performance Method cfm25 (Out or Totaij
To qualify as "substantially leakfree" Qn must not be greater than the
Proposed duct leakage Qn specified on Form R405-2014
Leakage Type selected
on Form R4052014
(Energy Calc)
Qn specified on form
R405-2014 (Energy Calc)
Company Name: SIJN SEAL LLC Phone: a2l-412-003S
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: 10/13/2Q?1
Signature of VA,41 Wa4
Printed Name of Tester: VDANIEL MURPHY
License/Certification Authority BPI
Envelope Leakage
(Blower Door Test)
R402,4.1.2 Compliance
Test Report
Permit #
Job information
Builder: DR HORTON Community:
CREEKSIDE Lot: 78
Address: 3329 TRINITY CIRCLE
Unit;
City: FORT PIERCE
State: FL Zip: 34945
Air Leakage Test Results Passing results must be 7 ACH(50)
or less
Method for calculating building volume:
:
1775 x 60 22403 � 4
CFM(50) Building Volume ACH(50)
Q Retrieved from architectural plans
(VCode software calculated
/1P ASS I FAIL
0 Field measured and calculated
I,- .�.
i ( When ACH(Sq) is less than 3, Mechanical
Ventilation installation must be verified by building department.
Certification of Test Results
.i k .,i—,n sir lanl-aaa rare rif not Pxreedine 7 air changes
R402.4.1.2 Testing. The building or aweiiing unit snail be test.eu d110 ve! it mu aS „av,,.6 — — . -_ -- - - -
per hour in Climate Zones I and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a
pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or
individuals licensed as set forth in Section 489.105(3)(9, (g), or (i) or an approved third party. A written report of the results of the test
shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of
ail rienetrations of the building thermal envelop -
Testing Company
Company Name: SUN SEAL IC Phone: 322-412-0035
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: 10/13/2021
Signature of Tester:
Printed Name of Tester: D IEL MURPHY
License certification 4 lsSuing Authority BPI