HomeMy WebLinkAboutBlower door test - Creekside Lot 78Duct Leakage Test Report Prescriptive or Performance Method Job Information Builder: DRHORT�I Community: CREEK ID Lint:78 Address Unit: City; FORT PIERCE State: FL`' Duct Leakage Test Results >Presciptive Method Performance Method I System 2 system 3 cfm25 Sum of any addi€ional of all systems 72 = 2602 = 0.02 € n Total of all systems PASS Total Conditioned Square Footage [�] FAIL Testing Company D Prescriptive Method cfm25 (total) T-o qualify as "substantially leak free" Qn must be less than or equal to 0.04 if air handier unit is installed. if air handier unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.2.2 Performance Method cfm25 (Out or Totaij To qualify as "substantially leakfree" Qn must not be greater than the Proposed duct leakage Qn specified on Form R405-2014 Leakage Type selected on Form R4052014 (Energy Calc) Qn specified on form R405-2014 (Energy Calc) Company Name: SIJN SEAL LLC Phone: a2l-412-003S I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 10/13/2Q?1 Signature of VA,41 Wa4 Printed Name of Tester: VDANIEL MURPHY License/Certification Authority BPI Envelope Leakage (Blower Door Test) R402,4.1.2 Compliance Test Report Permit # Job information Builder: DR HORTON Community: CREEKSIDE Lot: 78 Address: 3329 TRINITY CIRCLE Unit; City: FORT PIERCE State: FL Zip: 34945 Air Leakage Test Results Passing results must be 7 ACH(50) or less Method for calculating building volume: : 1775 x 60 22403 � 4 CFM(50) Building Volume ACH(50) Q Retrieved from architectural plans (VCode software calculated /1P ASS I FAIL 0 Field measured and calculated I,- .�. i ( When ACH(Sq) is less than 3, Mechanical Ventilation installation must be verified by building department. Certification of Test Results .i k .,i—,n sir lanl-aaa rare rif not Pxreedine 7 air changes R402.4.1.2 Testing. The building or aweiiing unit snail be test.eu d110 ve! it mu aS „av,,.6 — — . -_ -- - - - per hour in Climate Zones I and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or individuals licensed as set forth in Section 489.105(3)(9, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of ail rienetrations of the building thermal envelop - Testing Company Company Name: SUN SEAL IC Phone: 322-412-0035 I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 10/13/2021 Signature of Tester: Printed Name of Tester: D IEL MURPHY License certification 4 lsSuing Authority BPI