Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEA - FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 52 Block 1 Waterstone 2030 BGR Street: 5375 Lugo Street City, State, Zip: Fort Pierce , FL , 34951 Owner: Design Location: FL, ST_LUCIE_CO_INTL Builder Name: ADAMS HOMES Permit Office: Permit Number: Jurisdiction: 661000 County: St. Lucie (Florida Climate. Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1606.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1398.50 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 208.25 ft2 4. Number of Bedrooms 4 c. N/A d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2118.0 sqft.) R= ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 2038 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 2038.00 ft2 R=19.0 Conditioned floor area below grade (ft2) 0 c. N/A 80.00 ft2 R= ft2 7. Windows(247.3 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 139.26 ft2 a. Sup: Attic, Ret: Attic, AH: Main 6 407.6 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 53.81 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 4.768 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.299 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (2038.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2038.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.121 Total Proposed Modified Loads: 60.52 PASS Total Baseline Loads: 60.79 I hereby certify that the plans this calculation are in compli; Code. PREPARED BY: ff DATE: nA-01-9091 1A10nn Kenmany I hereby certify that this building, as designed, is in compliance with the Florida Energy Co OWNER/A�,E DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: - %-ompuance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as "certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.50 ACH50 (R402.4.1.2). *d Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 3il% is not greater than 0.040 Qn for whole house. 9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM'+R405-2020 INI PROJECT Title: Lot 52 Block 1 Waterstone 20 Bedrooms: 4 Building Type: User Conditioned Area: 2038 Address Type: Street Address Owner Name: Total Stories: 1 Lot # Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: Permit Office: Cross Ventilation: No 5375 Lugo Street Jurisdiction: 661000 Whole House Fan: No County: City, State, Zip: St. Lucie Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE Design Location Design Temp TMY Site Int Design Temp Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2038 17119.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2038 17119.2 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 174.6 ft 0 2038 ft2 ---- 0.35 0 0.65 ROOF # Type Roof Gable Roof Materials Rad Solar SA Emitt Emitt Deck Pitch Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles ' 2279 ft2 510 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2038 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2038 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 ft2 0.11 Wood 9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 RM 1 S Exterior Concrete Block - Int Insul Main 2 SW Exterior Concrete Block - Int Insul Main 3 W Exterior Concrete Block - Int Insul Main 4 NW Exterior Concrete Block - Int Insul Main 5 N Exterior Concrete Block - Int Insul Main 6 E Exterior Concrete Block - Int Insul Main 7 - Garage Frame - Wood, Main # Ornt Door Type 1 W Insulated 2 - Wood / Wall # Ornt ID Frame Panes 1 S 1 Vinyl Low-E Double 2 SW 2 Vinyl Low-E Double 3 W 3 Vinyl Low-E Double 4 W 3 Vinyl Low-E Double 5 W 3 Vinyl Low-E Double 6 W 3 Vinyl Low-E Double 7 NW 4 Vinyl Low-E Double 8 N 5 Vinyl Low-E Double 9 N 5 Vinyl Low-E Double 10 E 6 Vinyl Low-E Double 11 E 6 Vinyl Low-E Double 12 E 6 Vinyl Low-E Double 13 E 6 Vinyl Low-E Double # Floor Area Ceiling Are 1 683 ft2 683 ft2 WALLS Cavity Width MInhip R In F} Height In Area 4.1 48 0 8 6 408.0 ft2 4.1 5 2 8 4 43.1 ft2 4.1 13 11 8 4 116.0 ft2 4.1 5 2 8 4 43.1 ft2 4.1 51 10 8 6 440.6 ft2 4.1 40 11 8 6 347.8 ft2 13 24 6 8 6 208.3 ft2 DOORS Space Storms U-Value Main None .25 Main None .25 WINDOWS ation shown is the entered, Proposed orientation. NFRC U-Factor SHGC Imp Area Yes 0.33 0.23 N 48.6 ft2 Yes . 0.33 0.21 N 15.3 ft2 Yes 0.33 0.31 N 5.3 ft2 Yes 0.33 0.21 N 23.2 ft2 Yes 0.33 0.31 N 6.7 ft2 Yes 0.33 0.31 N 6.7 ft2 Yes 0.33 0.21 N 15.3 ft2 Yes 0.55 0.7 N 17.8 ft2 1 Yes 0.33 0.23 N 16.2 ft2 Yes M 0.55 0.7 N 17.8 ft2 1 Yes 0.33 0.23 N 32.4 ft2 2 Yes 0.33 0.23 N 32.4 ft2 1 Yes 0.33 0.23 N 9.8 ft2 2 GARAGE a Exposed Wall Perimeter Avg. Wall I 64ft 8ft INFILTRATION # Scope Method SLA CFM 50 ELA EgLA 1 Wholehouse Proposed ACH(50) .000293 1569.3 86.09 161.63 Sheathing Framing Solar Below ._waiup r ra Ctlnn Abonr r'rarlp9 0 0 0.6 0 0 0 0.6 0 0 0 0.6 0 0 0 0.6 0 0 0 0.6 0 0 0 0.6 0 0 0.23 0.01 0 Width Height Area Ft In Ft In 3 6 8 20 ft2 2 8 6 8 17.8 ft2 Overhang 2 2 2 2 2 Depth Separation - Int Shade Screeni 2 ft 0 in 0 ft 8 in Drapes/blinds None 2 ft 0 in 0 ft 8 in Drapes/blinds None 2 ft 0 in 0 ft 7 in Drapes/blinds None ft 0 in 0 ft 8 in Drapes/blinds None ft 0 in 0 ft 7 in Drapes/blinds None ft 0 in 2 ft 8 in Drapes/blinds None ft 0 in 0 ft 8 in Drapes/blinds None 7 ft 0 in 0 ft 2 in Drapes/blinds None ft 0 in 1 ft 0 in Drapes/blinds None 0 ft 4 in 0 ft 2 in Drapes/blinds None ft 0 in 0 ft 8 in Drapes/blinds None 0 ft 4 in Oft 2 in Drapes/blinds None ft 0 in 0 ft 8 in Drapes/blinds None Wall Insulation 1 ACH ACH 50 1012 5.5 9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM 405-2020 INPUT SUMMARY CHECKLIST HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing[ HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 407.6 ft Attic 101.9 ft Proposed Qn Main --- cfm 81.5 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Venting an f X� Jan Feb Feb H Mar Mar HX Apr Apr May May rl Jun Jun X Jul Jul u Mug Aug Se Sep rl Oct Oct Nov Nov Dec Dec [ Jan Feb Mar [ Apr [ May Jun [ Jul Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 .78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 .68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftZ O ft n a K11" , E 9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORI1ii R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 5375 Lugo Street, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1398.50 ft2 1 b. Frame - Wood, Adjacent R=13.0 208.25 ft2 c. N/A R= ft2 4 d. N/A R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2038.00 ft2 2038 b. Knee Wall (Vented) R=19.0 80.00 ft2 Area c. N/A R= ft2 139.26 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Main 6 407.6 53.81 ft2 13. Cooling systems kBtu/hr Efficiency 35.56 ft2 a. Central Unit 28.4 SEER:15.00 18.67 ft2 14. Heating systems kBtu/hr Efficiency 4.768 ft. a. Electric Heat Pump 28.2 HSPF:8.50 0.299 Area 15. Hot water systems ft2 a. Electric Cap: 40 gallons EF: 0.94 Insulation Area R=0.0 2038.00 ft2 R= ft2 R= ft2 b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: _� �Date: Address of New Home: City/FL Zip: Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. . *"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1