HomeMy WebLinkAboutENERGY EFFICIENCY CODEA -
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 52 Block 1 Waterstone 2030 BGR
Street: 5375 Lugo Street
City, State, Zip: Fort Pierce , FL , 34951
Owner:
Design Location: FL, ST_LUCIE_CO_INTL
Builder Name: ADAMS HOMES
Permit Office:
Permit Number:
Jurisdiction: 661000
County: St. Lucie (Florida Climate. Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type�1606.7 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1398.50 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0 208.25 ft2
4. Number of Bedrooms
4
c. N/A
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (2118.0 sqft.)
R= ft2
Insulation Area
6. Conditioned floor area above grade (ft2)
2038
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 2038.00 ft2
R=19.0
Conditioned floor area below grade (ft2)
0
c. N/A
80.00 ft2
R= ft2
7. Windows(247.3 sqft.) Description
Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33
139.26 ft2
a. Sup: Attic, Ret: Attic, AH: Main
6 407.6
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
53.81 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55
35.56 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 4.768 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.299
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (2038.0 sqft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 2038.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.121
Total Proposed Modified Loads: 60.52
PASS
Total Baseline Loads:
60.79
I hereby certify that the plans
this calculation are in compli;
Code.
PREPARED BY: ff
DATE: nA-01-9091 1A10nn Kenmany
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Co
OWNER/A�,E
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- %-ompuance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
"certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.50 ACH50 (R402.4.1.2).
*d Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 3il% is not greater than 0.040 Qn for whole house.
9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM'+R405-2020 INI
PROJECT
Title:
Lot 52 Block 1 Waterstone 20 Bedrooms: 4
Building Type:
User
Conditioned Area: 2038
Address Type:
Street Address
Owner Name:
Total Stories: 1
Lot #
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
Permit Office:
Cross Ventilation: No
5375 Lugo Street
Jurisdiction:
661000
Whole House Fan: No
County:
City, State, Zip:
St. Lucie
Fort Pierce
Family Type:
Detached
,
New/Existing:
New (From Plans)
FL, 34951
Comment:
CLIMATE
Design
Location
Design Temp
TMY Site
Int Design Temp Heating
Design Daily Temp
97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2038 17119.2
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2038 17119.2 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 174.6 ft 0
2038 ft2
----
0.35 0 0.65
ROOF
#
Type
Roof Gable Roof
Materials
Rad Solar SA Emitt
Emitt Deck Pitch
Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition
shingles ' 2279 ft2 510 ft2 Medium
N 0.85 N 0.85
No 0
26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2038 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2038 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ft2 0.11
Wood
9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 2 of 4
RM
1
S
Exterior
Concrete Block - Int Insul
Main
2
SW
Exterior
Concrete Block - Int Insul
Main
3
W
Exterior
Concrete Block - Int Insul
Main
4
NW
Exterior
Concrete Block - Int Insul
Main
5
N
Exterior
Concrete Block - Int Insul
Main
6
E
Exterior
Concrete Block - Int Insul
Main
7
-
Garage
Frame - Wood,
Main
# Ornt Door Type
1 W Insulated
2 - Wood
/
Wall
#
Ornt
ID
Frame
Panes
1
S
1
Vinyl
Low-E Double
2
SW
2
Vinyl
Low-E Double
3
W
3
Vinyl
Low-E Double
4
W
3
Vinyl
Low-E Double
5
W
3
Vinyl
Low-E Double
6
W
3
Vinyl
Low-E Double
7
NW
4
Vinyl
Low-E Double
8
N
5
Vinyl
Low-E Double
9
N
5
Vinyl
Low-E Double
10
E
6
Vinyl
Low-E Double
11
E
6
Vinyl
Low-E Double
12
E
6
Vinyl
Low-E Double
13
E
6
Vinyl
Low-E Double
# Floor Area Ceiling Are
1 683 ft2 683 ft2
WALLS
Cavity Width
MInhip R In
F}
Height
In
Area
4.1 48
0
8
6
408.0 ft2
4.1 5
2
8
4
43.1 ft2
4.1 13
11
8
4
116.0 ft2
4.1 5
2
8
4
43.1 ft2
4.1 51
10
8
6
440.6 ft2
4.1 40
11
8
6
347.8 ft2
13 24
6
8
6
208.3 ft2
DOORS
Space
Storms
U-Value
Main
None
.25
Main
None
.25
WINDOWS
ation shown is the entered, Proposed
orientation.
NFRC
U-Factor SHGC
Imp
Area
Yes
0.33 0.23
N
48.6 ft2
Yes
. 0.33 0.21
N
15.3 ft2
Yes
0.33 0.31
N
5.3 ft2
Yes
0.33 0.21
N
23.2 ft2
Yes
0.33 0.31
N
6.7 ft2
Yes
0.33 0.31
N
6.7 ft2
Yes
0.33 0.21
N
15.3 ft2
Yes
0.55 0.7
N
17.8 ft2 1
Yes
0.33 0.23
N
16.2 ft2
Yes
M 0.55 0.7
N
17.8 ft2 1
Yes
0.33 0.23
N
32.4 ft2 2
Yes
0.33 0.23
N
32.4 ft2 1
Yes
0.33 0.23
N
9.8 ft2 2
GARAGE
a
Exposed Wall Perimeter
Avg. Wall I
64ft
8ft
INFILTRATION
# Scope
Method
SLA
CFM 50
ELA
EgLA
1 Wholehouse
Proposed ACH(50)
.000293
1569.3
86.09
161.63
Sheathing Framing Solar Below
._waiup
r ra Ctlnn
Abonr r'rarlp9
0
0
0.6 0
0
0
0.6 0
0
0
0.6 0
0
0
0.6 0
0
0
0.6 0
0
0
0.6 0
0
0.23
0.01 0
Width Height Area
Ft In Ft In
3 6 8 20 ft2
2 8 6 8 17.8 ft2
Overhang
2
2
2
2
2
Depth
Separation
- Int Shade
Screeni
2 ft 0 in
0 ft 8 in
Drapes/blinds
None
2 ft 0 in
0 ft 8 in
Drapes/blinds
None
2 ft 0 in
0 ft 7 in
Drapes/blinds
None
ft 0 in
0 ft 8 in
Drapes/blinds
None
ft 0 in
0 ft 7 in
Drapes/blinds
None
ft 0 in
2 ft 8 in
Drapes/blinds
None
ft 0 in
0 ft 8 in
Drapes/blinds
None
7 ft 0 in
0 ft 2 in
Drapes/blinds
None
ft 0 in
1 ft 0 in
Drapes/blinds
None
0 ft 4 in
0 ft 2 in
Drapes/blinds
None
ft 0 in
0 ft 8 in
Drapes/blinds
None
0 ft 4 in
Oft 2 in
Drapes/blinds
None
ft 0 in
0 ft 8 in
Drapes/blinds
None
Wall Insulation
1
ACH ACH 50
1012 5.5
9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM 405-2020 INPUT SUMMARY CHECKLIST
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split Sing[ HSPF:8.5 28.2 kBtu/hr 1 sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow
SHR Block Ducts
1
Central Unit/
Split Sing[ SEER: 15 28.4 kBtu/hr cfm
0.75 1 sys#1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt
Conservation
1
Electric None
Garage 0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model # Area
Volume FEF
None
None
ftz
DUCTS
/
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 407.6 ft
Attic
101.9 ft
Proposed Qn
Main
--- cfm
81.5 cfm 0.04 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Venting
an
f X� Jan
Feb
Feb
H
Mar
Mar
HX
Apr
Apr
May
May
rl
Jun
Jun
X Jul
Jul
u
Mug Aug
Se
Sep
rl
Oct
Oct
Nov
Nov
Dec
Dec
[ Jan
Feb
Mar
[
Apr
[
May
Jun
[ Jul
Se
[X] Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
.78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
.68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ftZ
O ft
n a
K11" ,
E
9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORI1ii R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2
7. Windows-
Description
a. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.23
b. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.21
c. U-Factor:
Dbl, U=0.55
SHGC:
SHGC=0.70
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average
Overhang Depth:
Area Weighted Average
SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
5375 Lugo Street, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1398.50 ft2
1
b. Frame - Wood, Adjacent
R=13.0
208.25 ft2
c. N/A
R=
ft2
4
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2038.00 ft2
2038
b. Knee Wall (Vented)
R=19.0
80.00 ft2
Area
c. N/A
R=
ft2
139.26 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Attic, AH: Main
6 407.6
53.81 ft2
13. Cooling systems
kBtu/hr
Efficiency
35.56 ft2
a. Central Unit
28.4 SEER:15.00
18.67 ft2
14. Heating systems
kBtu/hr
Efficiency
4.768 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
0.299
Area
15. Hot water systems
ft2
a. Electric
Cap:
40 gallons
EF: 0.94
Insulation Area
R=0.0 2038.00 ft2
R= ft2
R= ft2
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: _� �Date:
Address of New Home:
City/FL Zip:
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
. *"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/1/2021 4:57 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1