HomeMy WebLinkAboutShingle product approval - Owens3/17/2021
Florida Building Code Online
FL #
FL10674-R16
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keelcr@owenscorning.com
Authorized Signature Greg Keeler
grog. keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
meLsancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nlemtnen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/7099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10674 R16 COT 2020 01 COI NIFMINEN Rddf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2019
Equivalence of Product Standards
Certified By
Sections from the Code
https:lffloridabuilding.org/prlpr_app_dtl,aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEAIpOjcKTwWbw°/aid°/a3d 112
3/17/2021
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
f I
Method 1 Option D
12/11/2020
12/17/2020
12/26/2020
02/09/2021
FL #
Model, Number or Name
.................... .
i Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, laminated, starter and hip & ridge shingles
Shingles and Starters
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R16 II 2020 12 11 FINAL ER OC ASPHALT
Approved for use outside HVHZ: Yes
;SHINGLE$ FL10674 R16.pdf
Impact Resistant: N/A
1 Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section S,
Evaluation Reports
FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.pdf
Created by Independent Third Party: Yes
0
Contact Us:: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-4B7-14
The State of Florida is an AA/EEO employer. Copyright 2007-2o13 State of Florida.:: Privacy 5tatement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresser are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487,1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F5. must provide the Department with an emait address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here .
Product Approval Accepts:
fthEck
Crodit Card
Safe
SCCUnty M ETi TICS"
https:/MoridabuiIding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgtBNbFY5V%2boQT%2b6w7ahRegICQ8ucR6ixlzAlpOjcKTwWbw%3d%3d 212
MEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Owens Corning Evaluation Report 037940.02.12-1111
One Owens Corning Parkway FL10674-R16
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7" Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / 11905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at tine request of the Building Official.
This Evaluation Report consists of pages 1 through 10,
Prepared by:
Robert J.M. Nieminen, P.E. Thefacsimile seal appearing was authorized by Robert
"•yES` :4�.•"c'- ' Nieminen, P.E. on 12111/2020. This does not serve as an
Florida Registration No. 59166, Florida DCAANF1983 c
CERTIFICATION OF INDEPENDENCE: electronically signed document.
I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
Z. NEW LTC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018 NEMO ETC, LLC
ROOFING SYSTEMS EVALUATION:
*NEMO I etc.
SCOPE:1.
Product Category:
Roofing
Sub -Category:
Asphalt Shingles
Compliance Statement:
Owens Corning Asphalt
Roof Shingles, as produced
by Owens Corning, have
demonstrated compliance with the following sections of the 7th Edition (2020) Florida
Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use sat forth herein-
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, R905.2.3
Physical Properties
ASTM D1970
2015
1507.2.5, R905.2.4
Material standard
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7,1, R905.2.6.1
Wind Resistance
ASTM D7158
2019
3. REFERENCES:
Entity
Examination
Reference
Date
Owens Corning
Declaration
Equivalency Declaration
08/06/2019
PRI(TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, VoL 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-112453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
07/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
PRI (QUA9110)
Quality Control
Florida BCIS
Current
PRODUCT4. DESCRIPTION:
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Plants
(}
Material
Standard
Description
Starter Strip Shingle
H-TX, OR
Accessory
Starter
Starter Strip Plus
MN, OR
ASTM D3462
starter strips for asphalt roof shingles
5RS TopShield Starter
MN, OR
Strips
Starter Shingle Roll
NH
ASTM D1970
mineral -surfaced, fiberglass -reinforced,
self-adheringSBS modified bitumen starter
Supreme'
GA, CA, CO, 1-TX, NJ, OH,
TN, OR, IL
ASTM D3462
fiberglass reinforced 3-tab asphalt
roof shingles
Berkshire`
MN
ASTM D3462
fiberglass reinforced, 4-tab asphalt
roof shingles
Duration' Premium
CA, OR
Duration' Premium COOL
CA
Asphalt
Shingles
g
ASTM 133462
fiberglass reinforced, laminated
asphalt roof shingles
TruDefinition° Duration®
IN, CA, CO, I TX, FL, NJ, OH,
MN, OR, GA, IL, TN
TruDefinition' Duration®
Designer Color Collection
Oakridge"
GA, IN, CA, CO, H-TX, I -TX,
FL, NJ OH, TN
TruDe#inition° Oakridge°
H-TX, I -TX
WeatherGuard° HP
TN
NEMO ETC, LLC Evaluation Report 037940.02.12-1411
certificate OfAurhorization N32455 11" EDITION (70ZQ) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 2 of 10
MEMO I etc.
TABLE 1: ASPHALTSHINGLE COMPONENTS
Type Product PlantMaterials} Standard Description
Berkshire' Hip and Ridge MN
Shingles with Sealant
Hip and DuraRidgel Hip and Ridge
Ridge Shingles with Sealant MN ASTM D3462 fiberglass reinforced, hip and ridge
Shingles ProEdge® GA, CA, OH, OR asphalt roof shingles
WeatherGuard° HP Hip and
Ridge Shingles TN
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Wind Classification; Refer to Section 6 for installation requirements to meet wind classifications
5.5.1
TABLE 2A: WINCE CLASSIFICATIONS, ASPHALT SHINGLES
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Supreme®
ASTM D3161(F) & ASTM D7158(H)
Berkshire'
Duration' Premium
Duration® Premium COOL
TruDefiniVon" Duration®
TruDefinAion" Duration' Designer Color Collection
oakridge°
TruDefinition®Oakridge'
WeatherGuard' HP
Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NFAAC) ETC, LLC Evaluation Report 037940.02.12-R11
Certificate of Authorization #32455 f" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 3 of 10
OMEMO I etc.
TABLE 2113: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE
Type Product FBC Table 1507.2.7.1 or R905.2.6.1
Starter Strip Shingle
Starter Strips Starter Strip Plus ASTM D3161, Class F
SRS TopShield Starter
Berkshire' Hip and Ridge Shingles with Sealant
Hip & Ridge DuraRidge® Hip and Ridge Shingles with Sealant
Shingles ProEdgel ASTM D3161, Class F
WeatheiGuard' HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 6111320-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tearoff)or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Fot undedayment Desk
- Self -adhered
WeatherLoW
k*_ underlayment
Drip_ ,
edge Drip edge
Nabs located
2"-r from eave
install first Self-sealing adhesive
Starter Strip positioned along eave
shingle with
6" rentoved
Starter Strip shingle overhangs eaves and rakes Ili'- V
Figure 1: Minimum Nailing, Starter Strip
rlgure t: Ivlinimum Nailing, Starter Strip Plus
NFiVIO ETC, LLC Evaluation Report 037940.02.12-R11
Certificate of Authorization #32455 7Tn EDITION (2D20) FBC NON-HVHZ EVALUATION FL10674-RIG
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 4 of 10
NMEMO J etc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions,
Drip edge
�i
6.3 ASPHALT SHINGLES:
Deck
,.-Underfayment
r
Drip edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
Self-sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
Berkshire" shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Normal Mansard or Area porn
Wind Areas High Wind desvanos y
Area porn vientos normales Areas vientos fuertes
Yip
5" Eacpnsure
Erpnsicidn
Figure 4: Minimum Nailing, Supreme
(Standard Size)
Normal Mansard or Area porn
Wind Areas High Wind desvanas r
Area porn vientos normales Areas vientos fuertas
,7111
Y2{AI Y2 Y
t
5 5/8" Exposure
Exposicion
Figure 5: Minimum Nailing, Supreme
(Metric Size)
NEMO ETC, LLC Evaluation Report 037940.02.12-Rll
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 5 of 10
6.3.1.2 Berkshire®:
Figure 6: 5-Nail Pattern, Berkshire
NNEMO I etc.
Sealant strip
La tita de s0ador
8'12" 8 W,
Figure 7: 6-Nail Pattern, Berkshire
Figure 8: Mansard or Steep Slope Pattern, Berkshire
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/111202U
Page 6 of 10
ONEMO I etc.
6.3.1.3 Duration® Premium TruDefinition® Duration Duration' Premium COOL & TruDefinition® Duration® Designer Color
Collection:
4-Nail Fastening Pattern
SureNailO fastening area width
Nail, TyplcaI
1" 12" I 12" 1..
{?-Cw ing 3..M1-Na;l • a8um Vwens Ga.ning swzMax�
eaposw¢
�—
6.1181, 5-518"
exymure
Figure 9: Standard 4-Nail Pattern, Duration
rigure iu: o-Evaii raicern, uuration
Fastening for Slopes Greater Than 21.12
SureNailG� fastening area width
Nail, Typical
12" . --1
I
cominu SurenaG'" • �rava,rzs flv��aKi� sua� ��• owb�„co,,� o
Four t" Spots of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern, Duration
• - 2"
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certfficote&fAatharization432455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 17/11/2020
Page 7 of 10
6.3.1.4 TruDefiniti0n'0akrid e® Oakridge":
4 Nail Pattern
Esquema con 4 cfavos
5 5f8" Exposure "'0'
Nails
Erpinkf6r1do5618pufg. Cfavos
Expasic on de;5/8 put g.
Figure 12: Standard 4-Nail Pattern, Oakridge
6.3.1.5 WeatherGuard® HP:
NNEMO i etc,
6 Nail Pattern
Psauema con 6 cfavps
i
5 UK Exposure Nails
P Ciavos 5 Sig" Exposure
Exposidon do 5 618pufg. Expnsid6n de 5518 pufg.
Figure 13: 6-Nail Pattern, Oakridge
Fastening for Slopes Greater Than 21:12
SureNailm Fastening area width
Nall, Typical
!-, aouaxp •0werta C"m�i�c 9crela 4b' •
Four 1" Spots of Asphalt Roofing Cement
Figure 14: Mansard or Steep -Slope Pattern, Oakridge
1" 12" 12, 1`12 D4.;. gy, �j
I PUS
f
v7%?i
5 5�5` Etpasue 5 5�B' E osvrs
Et;wsusdn is 5 5$ p�:Ig. Et ell de 5 5. g0g,
Figure 15: 6-Nail Pattern, WeatherGuard HP
6 Nail pattern
Esquema can 6 cloves
5 5,8" Exposure
I_xpo�cidn de 5 51`8 palg.
Nail 6 V8" from bottom
of shingle
Clove a 6 V8 ping. de h
6 Fasteners parts inferior de la teja
6 sujetardores
Four 1" Spots of Asphah Roof Cement
Cuatrtt prrn fps de cefna to de fecitu de ii[SU o de 1 pffigada
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
NEI1fl0 ETC, LLC Evaluation Report 037940.02.12-R11
Certificate ofAuthorizotion #32455 7T" EDITION (2020) FRC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 8 of 10
6.4 HIP AND RIDGE SHINGLES: ON EMo I etc,
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire' Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require
minimum two 12) nails per shingle.
➢ WeatherGuard® HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant:
Fig. A
Nails
Clavos
Prevailing Wind Direction
�— Direction del viento ptedominante
p I I I I
s" Etposure
position de B ping
4
A
Figure 17: Isometric View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip and Ridge Shingles-,
Fig. A Y
P rava I I Ing W Ind
Direction }y
A
Nails\\\\ 44
A I
44 I I
! I
I I ! I
p I I I
e
Exposure
Fig. B
Top View
Vista superior
It 1' H
Nail
clavo
• Owens Coming SureNad' s
I
I
I�
R! I U
UI�
UI
r
- 12'
Figure 18: Plan View, Berkshire and DuraRidge
Fig. C Hip & Ridge Shingle Fastening
Top V iew
Nails Nails
T'
2" 2"
Exposure
12
Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20. Plan View, WeatherGuard HP Hip and Ridge
NEIVIO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate afAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 9 of 10
6.4.1.3 ProEde°:
Prevailing
Wind Direction Sealant Strip
Ai--
6" Exposure
Fasten 711,"
Cover Exposed
Fasteners with
Roof Cement
Figure 21: Isometric View, Pro Edge
NNEmo I etc.
Standard
Fastening
Pattern
12' I Seafiht
7 jZl 6" Exposure
Figure 22: Plan View, ProEdge
mmmmmm77requjred by the Building official or Authority Having ,Jurisdiction to properly evaluate the installation of this
product.
MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9.
PRI Construction Materials Technologies, LLC— QUA9110 ; 813 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT -
MEMO FTC, LLC Evaluation Report 037940.02.12-Rll
Certificate ofauthorlmtian #32453 77" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/Z020
Page 10 of 10