WIND LOAD CERTIFICATIONS
ENGINEERING SUBMITTALS JULY6, 2021 WIND LOAD CERTIFICATION.' CODE.' FBC/FRC2020 /ASCE716/NEC2017 (FBC 71H EDITION WIND SPEED., 170 MPH, 3 SEC. GUST EXPOSURE.' "D" CATEGORY// !!'' INTERNAL PRESSURE COEFF.' 0.00 eG�P� kA JOB: J�� FLORENCE <j� G G� oco 101 AQUA RA DRIVE GQo v Awl, JENSEN BEACH, FLORIDA �'C • ci 40 PAUL WELCH INC. MECHANICAL ELECTRICAL CIVIL ENGINEERING 1984 S. W. BILTMORE ST. SUITE #1 l4 PORT SAINT LUCIB, FL 34984 (772) 785-9888 pwelchinc@aol.com PAUL WELCH, P.E. ALA REG No. 29945 N� FLORENCE 101 AQUA RA DRIVE JENSEN BEACH 3 i Jerner & Associates, Inc. Marine & Environmental Consulting 2537SEAlfonso Ave. Port St. Lucie, FL34952 Ph.(772)283.2950 JERNER@BELLSOUTH.NET POR1 2021 INC. 11L ENG. 3T. #114 SAINT LUCIE, FL 34984 PAUL WELCH R.E. FLA REG 1\10.29945 Date: 2115121 0;1 FLORENCE 101 AQUA RA DRIVE JENSEN BEACH SA SUR VEY PERFORMED BY BRUCEJERNER ON JUNE 2, 2021. CANAL BOTTOM CONSISTS OF SILT LAYER WITH THICK LEAF LITTER/DETRITUS COVER. VISIBILITY < 5: NO SAV OBSERVED ' Jerner & Associates, Inc. I Marine & Environmental Consulting 2537SEAlfonsoAve. Port St. Lucie, FL34952 1 I Ph.(772)283-2950 yam; JERNER@BELLSOUTH.NET JUL 0 6 2021 PAM WELCH INC. MECH-ELECT-CIVIL ENG. 1984 RILTMORE ST. #114 PORT SAINT LUCIE, FL 34984 PAUL WELCH R.E. FL4 REG NO.29945 Date: 2115121 SHEET 2 PROPERTYLINE _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. ...... _.._. I I I IA la IA I� MHWL & MLWL FALL r7a m TOE OFSEA WALL 46' i Q i i ......'�•�— EDGEOFMANGROVE i CANOPY i RIVER WATCH BLK 5 LOT 1 4' i �••••8'••••'• v- 18' i i CANAL ANNi��11DE 110 i PROPERTYLINE j _.._.._. _.._.._.._.._.._. _.._.._.._.. JUL 0 6 2021 FLORENCE 101 AQUA RA DRIVE JENSEN BEACH jerner & Associates, Inc. I Marine & Environmental Consulting I I ki 2537SEAlfonso Ave Port St. Lucie,FL34952 i PIL(772)283-2950 JERNER@BELLSOLITH.NET PAUi. WELCH INC. MECH-ELECT-CIVIL ENG. 1984 BILTI MORE ST. #114 PORT SAINT LUCIE, FL 34984 PAUL WELCH R.E. FLA REG R02�945 1 "= 20' SHEET 3 Date: 2115121 EXISTING SITE FEA TURFS PROPERTYLINE _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._........ ...... _ I I I� I� I� I MHWL & MLWL FALL @a m TOE OFSEAWALL 46'-------------- i �I I AA/ RIVER WATCH BLK 5 LOT 1 18' i i i i i i i PROPERTYLINE j FLORENCE 101 AQUA RA DRIVE JENSEN BEACH .•'�— EDGE OF MANGROVE • • CANOPY ,4lei(-)61WW PR s`ED\© TOTAL NEW DOCKARE4 = 431 SQ FT LIFT moo` + 100 SQ FT FLOATING DOCK REPLACE & EXPAND DOCK •, p,L i BADE D ------------------------; A `N 1� 11.0 EXISTING DOCK t TO BE REMOVED JUL 0 6 2021 i AUL WELCH INC. tviECH-ELECT-CIVIL ENG. 1984 BILTMORE ST. #114 ^'3T SAINT LUCIE, FL 34984 PAUL WELCH R.E. LA REG N0.29945 Jerner & Associates, Inc. I Marine & Environmental Consulting 2537 SE Alfonso Ava Port St. Lucie, FL34952 Pk(772)283-2950 i ry� JERNER@BELLSOLITH.NET 1 "= 20' SHEET 4 Date: 2115121 PROPOSED SITE FEA TURFS Pier Section Thru Pier Plan View Live Load 40 lbs. / Sq Ft Dead Load 5 lbs. / Sq Ft 41, VARIES F SGL Bolts, Nut, Washers 5/8" S. S. -► (304) w Nut Fully Threaded 2" X 6" SYP or Composite decking w minlmal plank spacing. Fasten w #10 3" SS (304) Screws, 2 per s Stringer 2" x 8" P. T. SYP, .40 ACQ treated stringers to be butt jointed, butt - .=• ••-••-••-••-••-••-•• joints to be staggered. 2" x 8" P. T. SYP, .40 . _ Mew._.. ACQ treated DBL bents co 4 s cc i GRADE New Pilings jetted to a minimum depth of Wand as necessary to provide adequate bearing and stability FLORENCE 101 AQUA RA DRIVE JENSEN BEACH -Min. 8" Dia. 2.5. CCA treated piles Design Windload Information Code: FBC 2020 7TH ADD/ FBRC 2020 7TH ADD/ ASCE 7-16 Wind Speed. 170 MPH, 3 Second Gust Exposure `D" Importance Factor: 1.0 Internal Pressure Coeff.: 0.00 Height: <10 Ft. Mean VARIES No Stringers 24" 0. C. Max Center Stringers) toe Nailed w (2) #16 SS (304) Ring Shank Nails @ Each Bent, Outside Stringers Face Nailed w #16 SS (304) Ring Shank Nails Inside or Outside /PAUL WELCH INC. MECH-ELECT-CIVIL ENG. 1984 BILTIIIORE ST. #114 PORT SAINT LUCIE, FL 34981 PAUL WELCH R.E. JUL 6 2021 FLA REG R0?9945 I - ' Jerner & Associates, Inc. Marine & Environmental Consulting `-1` -- 2537SEAlfonso Ave . Port St. Lucie,FL34952 i ;IN Ph.(772)283-2950 (- JERNER@BELLSOLITH.NET Date: 2115121 SHEET 5