HomeMy WebLinkAboutEnergy Code` F6RM R405-2020
FLORIDA ENERGY EFFICIENCY CODE=FOR BUILDING CONSTRUCTION
- Florida Department of Business and Professional Regulation - Residential Performance Method
-
Project Name: Lot 19 Phase 3 Waterstone 2508 CRGL
Builder Name: ADAMS HOMES
Street: 8324 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design • Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�2020.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1748.70 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 272.00 ft2
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2623.0 sqft.)
Insulation Area
6. Conditioned floor area above grade (ft2) 2523
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 2523.00 ft2
R=19.0 100.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(296.4 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 6.173 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.288
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (2523.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.117 Total Proposed Modified Loads: 71.46
A
PASS
Total Baseline Loads: 71.84
I hereby certify that the plan cifications covere
jew of the plans and
Sr9
this calculation are in co I ith the Flo ' nergy
specifications covered by this
b�H�
r8p
Code.
calculation indicates compliance
t�'v"!ir�f�� , ��•?` �'�'
with the Florida Energy Code.
r
PREPARED BY:
Before construction is completed
DATE: 08-09-9091 Winn Kenmany
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
,t .
with the Florida,ode.CpD
.:
OWNER/AGEN 1
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
• - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
• tested in accordance with ANSI/RESNET/ICC 380, is not than 0.060 for
greater
Qn whole house.
6/9/2021 12:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2n2n 1K1D11T C11RARAenv 1r
vvm ml9�� %.,I 1 1[CI'VI'C 1
PROJECT
Title:
Lot 19 Phase 3 Waterstone
2 Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 2523
Lot #
19-3
Owner Name:
# of Units:
1
Total Stories: 1
Block/Subdivision:
Waterstone
Builder Name:
ADAMS HOMES
Worst Case: No
Rotate Angle: 0
PlatBook:
Permit Office:
Cross Ventilation: No
Street:
8324 Amalfi Circle
Jurisdiction:
661000
Whole House Fan: No
County:
City, State, Zip:
St. Lucie
Fort Pierce
Family Type:
Detached
,
New/Existing:
New (From Plans)
FL , 34951
Comment:
CLIMATE
/
V Design
Location
Design Temp
TMY Site
Int Design Temp Heating
Design Daily Temp
97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2523 22202.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 22202.4 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ftz
0.44 0
----
0.56
ROOF
/
V #
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ftz 630 ftZ Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
#
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2523 ftZ 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
100 ftZ 0.11
Wood
6/9/2021 12:08 PM EnergyGauge® USA 7.0.00 - F]aRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
ruKivl K4Ub-1UZU
INPUT SUMMARY CHECKLIST REPORT
WALLS
^
Adjacent
yppSpace
Cavity
Width
Height
Sheathing Framing
Solar
Below
1
2
3
4
5
6
7
8
9
E
N
W
SW
S
-
S
E
W
Exterior
Exterior
Exterior
Exterior
Exterior
Garage
Exterior
Exterior
Exterior
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Frame - Wood
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Main
Main
Main
Main
Main
Main
Main
Main
Main
4.1
4.1
4.1
4.1
4.1
13
4.1
4.1
4.1
48
37
51
6
37
34
23
8
6
6
2
3
2
6
0
6
6
0
8
8
8
8
8
8
8
8
8
0
0
0
0
0
0
0
0
0
388.0 ft2
297.3 ft2
410.0 ft2
49.3 ft2
300.0 ft2
272.0 ft2
188.0 ft2
68.0 ft2
48.0 ft2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.23
0
0
0
0.6
0.6
0.6
0.6
0.6
0.01
0.6
0.6
0.6
0
0
0
0
0
0
0
0
0
DOORS
V #
Ornt Door Type
Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
N Insulated
Main
None
.25
3
6 8
20 ft2
2
- Wood
Main
None
.25
2 8
6 8
17.8 ft2
3
W Insulated
Main
None
.25
2 4
6 8
15.6 ft2
/
V #
Ornt
Wall
ID
Frame
Panes
1
E
1
Vinyl
Low-E Double
2
E
1
Vinyl
Low-E Double
3
N
2
Vinyl
Low-E Double
4
N
2
Vinyl
Low-E Double
5
N
2
Vinyl
Low-E Double
6
N
2
Vinyl
Low-E Double
7
W
3
Vinyl
Low-E Double
8
W
3
Vinyl
Low-E Double
9
SW
4
Vinyl
Low-E Double
10
S
5
Vinyl
Low-E Double
11
S
5
Vinyl
Low-E Double
12
S
7
Vinyl
Low-E Double
_ 13
S
5
Vinyl
Low-E Double
14
N
2
Vinyl
Low-E Double
# Floor Area
1 620 ft2
WINDOWS
NFRC U-Factor SHGC
Yes
0.55
0.7
Yes
0.33
0.23
Yes
0.33
0.31
Yes
0.33
0.31
Yes
0.33
0.21
Yes
0.33
0.21
Yes
0.33
0.23
Yes
0.33
0.23
Yes
0.33
0.23
Yes
0.55
0.7
Yes
0.33
0.23
Yes
0.33
0.23
Yes
0.33
0.23
Yes
0.33
0.31
GARAGE
;fling Area Exposed Wall Perimeter
620 ft2 64 ft
N
N
Overhang
-np
Area
Depth
Separation
Int Shade
Screeninc
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
N
32.4 ft2
1 ft 4 in
O ft 10 in
Drapes/blinds
Exterior 5
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
N
32.4 ft2
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
Exterior 5
N
9.8 ft2
1 ft 4 in
Oft 10 in
Drapes/blinds
Exterior 5
N
16.2 ft2
1 ft 4 in
O ft 10 in
Drapes/blinds
Exterior 5
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
Exterior 5
48.6 ft2
1 ft 4 in
1 ft 2 in
Drapes/blinds
Exterior 5
3.0 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
Wall
8ft
Wall Insulation
1
6/9/2021 12:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
1 Wholehouse Proposed ACH(50)
SLA
.000391
CFM 50 ELA EgLA ACH ACH 50
2590.3 142.11 266.8 .1312 7
HEATING SYSTEM
# System Type
1 Electric Heat Pump/
Subtype
Split
Speed Efficiency Capacity
Singl HSPF:8.5 42 kBtu/hr
Block
1
Ducts
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
/
---- Supply ----
# Location R-Value Area
---- Return --- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling Jan Feb Mar
Heating LX Jan H Feb Mar
[ Jan Feb X Mar
Ceiling Fans:
Apr May rj Jun X Jul X Au rl Se
APr May Jun f Jul f AuSep
[X] Apr [ May Jun [ Jul [ Aug Se [X]
Oct Nov
Oct NovDecVenting
Oct X Nov
Dec
Dec
6/9/2021 12:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
r
PM
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
PM
68
68
68
68
68
68
68
Heating (WEH)
AM
66
66
66
66
66
68
68
PM
68
68
68
68
68
68
68
MASS
Mass T e
8 9 10 11 12
78
0
78
80
80
0
78
78
78
78
78
78
78
78
78
78
78
78
78
78
68
68
68
68
68
68
68
68
66
66
68
68
68
68
68
68
68
68
66
RR
Yp Area Thickness Furniture Fraction
Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3
6/9/2021 12:08 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FOtRM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.70
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
8324 Amalfi Circle, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1748.70 ft2
b. Frame - Wood, Adjacent
R=13.0
272.00 ft2
1
c. N/A
R=
ft2
4
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ft2
2523
b. Knee Wall (Vented)
R=19.0
100.00 ft2
Area
c. N/A
R=
ft2
166.06 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
70.92 ft2
13. Cooling systems
kBtu/hr
Efficiency
35.56 ft2
a. Central Unit
42.0 SEER:15.00
23.83 ft2
6.173 ft.
0.288
Area
ft2
Insulation Area
R=0.0 2523.00 ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature Date:
Address of New Home:
City/FL Zip:
kBtu/hr Efficiency
42.0 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/9/2021 12:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1