HomeMy WebLinkAboutProduct Approval C2 ow
al
MIAMI-DADE COUNTY
MIAMI DADS PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade.County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the '-AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD®,Timberline®Natural Shadow®,Timberline®NS,Timberlinee American
Harvest®,Timberline®AH,Timberline®HDZTM,Timberline®CS and Fortitude®Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will-occur after the expiration date or if there has been a revision or change in the
materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 16-0811.11 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino
MIAMI•D,4DE COUNTY
NOA No.: 19-0312.04
••• ON Expiration Date:02/21/22
Approval Date: 01/09/20
Page 1 of 7
S
t
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline HD®,Timberline®Natural Shadow®,Timberline NS®,Timberline American®
Harvest®,Timberline AH®,Timberline®HDZTM,Timberline CS®and FortitudeTM Shingles as.manufactured by
GAF as described in this Notice of Acceptance. i
PRODUCT DESCRIPTION
I
Product Dimensions Test Product Description
Specifications
GAF Timberline HD® 13 1/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Locations#1,29 3,49 59 69 7
'
GAF Timberline®Natural 13 1/a"x 39 3/8" TAS 110 Fiberglass reinforced heavy g as weight halt roof
P
Shadow®and Timberline®NS shingle,with a laminate profile
Manufacturing
Locations#1,29 3,4,59 69 7
GAF Timberline®American 13 '/a"x 39 3/s" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Harvest® shingle,with a laminate profile
Manufacturing
Locations#2,4,69 9
GAF Timberline®AH 13 '/a"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Locations#2, 4, 6, 9
GAF Timberline®HDZ' 13 '/a"x-3 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Locations#1 29 39 49 5 6 7 8
GAF Fortitude° 13 '/a"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Location#4
i
GAF Timberline®CS 13 '/a°x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Location#9
IMIAM4DAUE COUNTY
NOA No.: 19-0312.04
I�� •••. Expiration Date:02/21/22
Approval Date:01/09/20
Page 2 of 7
I
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City,IN
3. Baltimore,MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
8. Shafter, CA
9. Fontana,CA
I
i
I
I
it
MIAMI•DADE COWNTY
NOA No.: 19-0312.04
• Expiration Date:02/21/22
Approval Date:01/09/20
Page 3 of 7
• I
l
f
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Renort Date
Underwriters Laboratories,LLC ASTM D3462 4788932264 12/13/19
Underwriters Laboratories,LLC ASTM D3462 4788717129 01/31/19
Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16
Underwriters Laboratories,Inc. ASTM D3462 11CA48924 10/22/11
Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11
Underwriters Laboratories,Inc ASTM D3462 1 OCA28717 07/26/11
Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-62-02 11/02/05
Underwriters Laboratories,Inc. ASTM D3462 06NK051,59 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories,Inc.Center for ASTM D3462ASTM 03NK26444257989 10/17/03
Applied Engineering D3462 05/13/97
Underwriters Laboratories,LLC TAS 107 4789225984 11/1/19
Underwriters Laboratories,LLC TAS 107 4788717529 01/31/19
Underwriters Laboratories,Inc. TAS 107 OINK458103 04/13/94
Underwriters Laboratories,Inc. TAS 107 06NK05 69 08/09/06
Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories, Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NK41911 11/11/02
Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies, Inc. TAS 100 GAF-912-02-01 12/17/18
PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06
PRI Asphalt Technologies,Inc. TAS-100 ELK7083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-0 8 8-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
I
I
MIAMI•DADE COUNTY
NOA No.: 19-0312.04
• • Expiration Date:02/21/22
Approval Date: 01/09/20
Page 4 of 7
i
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft. I!
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 1;15.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions. j
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail'B',attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
j
MAMPDADE COUNTY
BUILDING PERMIT REQUIREMENTS j
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance. I
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
i
I
-
MIAMI•DADE COUNTY
NOA No.: 19-0312.04
• • Expiration Date:02/21/22
Approval Date: 01/09/20
Page 5 of 7
r
r
I •
I
DETAIL A
I
COURSE LAYOUT i
i
I
I _
DECK
FULL
I
i
I
5th
17"OFF 4th
i
I
11"OFF 3rd
6"OFF 2nd I
I
i
FULL 1st 5-5/8" Exposure
I
r
i
I
I
I
MI/4M1•DADE COUNTY
NOA No.: 19-0312.04
• Expiration Date:02/21/22
Approval Date: 01/09/20
Page 6 of 7
'i
DETAIL B i
OVERALL DIMENSIONS AND NAILING PATTERN j
FOR TIMBERLINE HD® TIMBERLINE® NATURAL SHADOW® AND TIMBERLINE®NS
i
'3:9 3/8
14 1& -17 1/2" 14.112'-17-'1/2"
(368-'445mm) {368 445mm}
6 1 ;9 I2 —f - — -w- — -- :a— —,fis , t� (14.6
�4 guide line
3—�.l4r� ' � � >'a 6-1/4".
46mm 159mm
from bottom of shingle
i
elf seal
adhhesive�
on back
ENHANCED NAILING PATTERN six nails per shingle*`
required:by'sorpe looat codes and.xiandired for.e6 apced wind coverageon certain}iroducts:
Sea limited warranty for details,
I
These shingles MUST be nailed a nominal 6"052mm)`fr6m bottom of
of shingle, above the cut outs, as shown. Nails must riot be exposed.)
OVERALL DIMENSIONS AND NAILING PATTERN
FOR TIMBERLINE®HDZ'mq TIMBERLINE®CS,TIMBERLINE®AH,AND
FORTITUDE®
14112° V412'tS68inm=445mm) 191f>'-17-37 '3f n�m-4abmml:
6112°=.9=fry;.{185mm`=2d1'ini) Cr112°-.3-1f2'(165mm=241 mm)
1t� 2 it (18 Enm76 rrtm} 1 `2=i {13r imn:U rhm}
f3 1/40
(337.mtn) v J. .. . of r
...
" .:: ......:. ........ ....:5 .....:.�:. r r
... ... .... .......:.... ....... ........ . _...TARGET
!-pl§7 6114'
5:=131f 64-:7 518"
�(148 mm 159 slim) (148 mtn =9,9,4 thin}
For fuldRga �aGtB. : -
1
T i
1
END OF THIS ACCEPTANCE
i
MIAMI•DADE COUNTY
NOA No.: 19-0312.04
• Expiration Date:02/21/22
Approval Date:01/09/20
Page 7 of 7
514126618 TFWZ-.R21--Prepared Roof-covering Materials
.1
__fINLINE CEFtT1FICAT'IONS EY1111C.TO Y
UL y
UUS NEXT GENERATION ' j , SEARCH
LEARN OR
' _ e same trusted data in a modern
TFWZ.RZ1
Prepared Roof-covering Materials
Page Boitom �
Prepared 'Roof-covering Materials
y
See Genera6Information for Prepared:Roof-covering Materials
GAF R21
1 CAMPUS DR
PARSIPPAN NI 07054 USA
® , '!Sentinel@ ASTM D3462", "Timberlin
Asphalt glass.fiber that shingles-''Royal,Sovereign®","Sentinel �" 'ep HD", "Timberline®Natural
Shadow","Timberline®Ultra HD',"Timberline®Cool Series","Timberline®Majestic", "Timberline@ Majestic[30%"Timberline®American
Harvest'""; "Fortitude7'4", "Tirnberlinetj ArmorShiel[&m II", "Grand Timberiinep% 'Marquis@ WeatherMax@ , 'Grand Canyon•"","Grand
Sequoia@%"Grand Sequoia@ IR","Grand Sequoia@ ArmorShieldT"", "Camelot@', "Cairtelot@ iI "Capstone@?',"Country Mansion*","Country
Mansion@ II","Grand SlateTm", Grand Slate'"II".;"Slateline®", 'Woodland@% "Monaco."', "Sie.nna®"and"6lenwood'^ for installation as Class
A prepared roof covering.`Suitable for:installatbn on minimum 3/8=ln.thick plywood roof decks in combination with minimum one ply '•Shingle-
Mate".or Type 15.or Type 30.underlayment.Also Classified in accordance with ASTM D3161,Class.F.'Aiso Classified in•accordance with ASTM
D3462/D3462M.Also Classified in accordance:with•ICC ES AC438.
Asphalt glass fiber ntatshingles="WeatherBlocker Starter•Strip:Shingles",•and"Pro�StartT"Starter Strip Shingles"for installation as Class A
roof covering;Suitable for installation on mini.mumR3/8-in.thick plywood in combination with minimum one ply•"Shingle-Mate"or Type 15,orType
30 underlayrhent.Also Classified in accordance wit 'ASTM D3161/03161M,Class A.Also Classified in accordance with ASTM D3462/D3462M.
1:
Asphalt glass fiber mat shingles--"Royal Sovereign@","Sentinel@", "Timberline@ HD" "Timberline®.Nat I eai Shadow",."Timberiineb Ultra
HD", "Timberline®Cool Series", American Harvests, Fortitude , Marquis®;WeatherMax® , Grand Canyon ,'Grand SequoiaOR 'Grand
Sequoia@ IR",and "Camelot®"for Installation as:Class A prepared roof covering when used with minimum Type 30 underlayment.over existing
wood shingle roof.
Asphalt glass mat hip and ridge shingles- 'Tuiibertex NO,and Ridge"for installation as Class.A prepared•roof covering:Also been evaluated in
accordance with ASTM D3161/D3161M;Class F when Henkel"PL Roofing and.Flashing Sealant"or Sonneborri"NP1 Gun-Grade Polyurethane
Sealant"is applied'as specified in.m nufacturer's application instructions."Also.Classified in accordance with ASTM D3462/1)3462M;
z
Asphalt glass mat hip and ridge shingles,"Z-Ridge"for installation as Class A prepared roof coverings.
•4
Asphalt glass mat hip and ridge.shingles, "Seal-A-RidgeftA ArmorShieldT14'!and"SealcA=Ridge®IR"for installation as.:lass A prepared roof
coverings, Also been evaluated in accordance.with ASTM D3161/D3161M,Class A.Also Classified in accordance with ASTM D3462JD3462M:
Asphalt glans mat hip and'ridge shingles, Seal"A-Ridge®"for installation as Class A prepared roof coverings.Also been evaluated in
accordance 4ith ASTM D3161/D3161M,Class F when Henkel Corp. "Loctite PL S30 Roof.&Flashing Sealant"Is applied as specified in
manufacturers Installation:Instructions.Also Classified:in accordance with ASTM D3462%D3462M.
Asphalt glass mat hip and ridge shingles,'Ridglass@"for installation as Class,A prepared roof'coverings,•Also been evaluated in•accordance
with ASTM 133161%D3161M,Class A.Also Classified In accordance with ASTM D3462/D3462M.
Asphalt glass mat hip and ridge shingles, 'RidglassO II"for installation as Class A prepared roof covering.Also been evaluated in accordance
with ASTM D3161/D3161M,.Class•A as specified in manufacture'r's installation instructions,Also Classified in accordance with ASTM
D3462/D3462M.
i,
Asphalt.glass mat hip and ridge shingles,"Rid6lass0 II"for installation'as Class A prepared.roof covering.Also been evaluated in accordance
with ASTM D3161/D3161M,Class F'when ASTM C920 Henkel"Loctite PLRoofing and Flashing Sealant" is applied as specified in manufacturer's
installation Instructions.Also.Classified in accordance with ASTM D3462/D3462M. f
Last Updated on 2018-0.17:1 x.
_Questions? 3i Print this pgge Terms of Use Page Top.
5 ;. -�
V,
c)2018 UL LLC
The a ppeararice of a company's name or product inxthis database does:not In itself assure that products so identified have been manufactured
under UL's Follow-Up Service..Only those products bearing the UL`Mark:should be considered to-be Certified and covered under UL's Follow-Up
Service.Always look for the Mark on the product
littp://database.,,vl.com/`cgirbihf)<YV/tetnplat6/LlS.EXTilFMME/showpage:html?name=TFWZ'R2'19ecnshorttitle=Prepared+Roof-covering+Materials&objid=1074
I;