Loading...
HomeMy WebLinkAboutAPPROVED Mcgowin engineering and NOA0 0 0 0 O O 0 n x z G S z G) O 0 0 3 W D 2 Cl M O 0 W m �(n 1--I 3 A O 1r-i O Fy 3 0 n W ^z °ID-rnpD o n Z Z O N z D m p ^ n N Z D o O c 3 6 0. ° - rn 0 3 N _ V O z N os M� K- > > a F x c m0_ > n O m m C p c o M D G1 0 N m n p 0 N -DI 10 Z 3? � � m m 3 o n O m N Gl O C A w 3° c� cny R° 2 S-I mO0 C o oc 3 p $ c a n� W nT m n°iD o Z r O n c n A o AQ u� W DA p p O N D -wig Znj c Q n O mz ntn m W Sin G)m 'n m C (7 C 3n �� ON z n 3 rr- DD mz zz zO O -o �a v p-° n Sc °1 mini m ^ "Ap D m pA O wO go m D O N m0 O v d G 3 O S N Z m W C Z n N m A O m n 3 N D r z O ry D r08 p N z p 3 nc D m W m n ZO �- a mzrmGlm "�pp p A n cm -z z V) n O C + L �o0m m�<m o r fll w �a v3 �' o cW p Z w O,. mp.."w h� cv On v 3 n m n °n m z zz m p + G1 m �o � 2 o � O�OOOO �z Z O r m p p p p p � A ZLl O O L1 � ,n A O Ll ➢� Lz1 G) D p C $\ N VNl VNl N (h z p O A O A O A O A O A w - X X X X N X N `^ X N X N 2 m 3 D[[D�� n-i 3 3 3 (D(�� 3 (D� 3 D � p� w A (Nli -I -Ai O z =4=P McGowan RESIDENCE . OCEAN DRIVE UNIT 1501 JENSEN BEACEi FL N~ = 7 SLIDING GLASS DOOR &WINDOW Co Wo REPLACEMENT DETAILS z p;' W o- = z _ 1 — _ z m m :rlo 0 m a �tn'•v m o''•Gi\ v iiyCj'• 0�\�� ire o G 0kja N MIAMI•ra,DE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, FL 33175 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv WinDoor, Inc. 104 Triple Diamond Blvd. North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "560" Aluminum Sliding Glass Door (2-tracks) w/ wo Reinforcements — L.M.I. APPROVAL DOCUMENT: Drawing No. 560-2T-LM-NOA, titled Series "560 Aluminum Sliding Glass Door (LMI)", sheets 1 through 16 of 16, prepared by manufacturer, dated 06/10/20, signed and sealed by Anthony Lynn Miller, P. E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and Expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revised 18-0926.13 and consists of this page 1 and evidence page E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. NOA No. 20-0729.07 11/26/2020 Expiration Date: June 12, 2023 Approval Date: November 26, 2020 Page 1 WinDoor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections (See NOA 420-0729.05) 2. Drawing No. 560-2T-LM-NOA, titled Series "560 Aluminum Sliding Glass Door (LMI)", sheets 1 through 16 of 16, prepared by manufacturer, dated 06/10/20, signed and sealed by Anthony Lynn Miller, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of all CGI Windows and Doors, Inc. and PGT Industries, Inc., representative units listed below and tested to qualify Dowsi1791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: CGI Windows and Doors Inc test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20- 2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E. PGT Industries, Inc. test -specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20- 2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20- 2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS Anchor verification calculations and structural analysis, complying with FBC 7th Edition (2020), dated 07/20/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-04, -09, -12 and -16. D. QUALITY ASSURANCE l . Miami Dade Department of Regulatory and Economic Resources (RER). Sifang Zhao, P.E. Product Control Examiner NOA No. 20-0729.07 Expiration Date: June 12, 2023 E 1 Approval Date: November 26, 2020 - WinDoor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlasg (Clear and White) Glass Interlayers", expiring on 07/04/23. 2. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) (former Solutia, Inc.) for their "Saflex CP- Saflex and Saflex HP Composite Glass Interlayers with PET Core", expiring on 12/11/2023. F. STATEMENTS 1. Statement letters of conformance to FBC 2020(7th Edition), dated 07/20/20, prepared, signed & sealed by Lynn Miller, P. E. 2. Notification of Successor Engineer per the Florida Administrative Code Section 61G15- 27.001, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated 07/20/20, signed and sealed by A. Lynn Miller, P.E D. OTHERS 1. Private labeling agreement between WinDoor, Inc. and CGI Windows and Doors, Inc. document in conformance of RER guideline dated 09/12/2018. (Submitted under NOA #18-0926.13) 2. Notice of Acceptance No. 18-0926.13, issued to Windoor, Inc. for their Series "560" Aluminum Sliding Glass Door (2-tracks) w/ wo Reinforcements — L.M.I., approved on 07/03/18 and expiring on 06/12/23. 3. Notice of Acceptance No. 20-0729.05, issued to CGI Windows and Doors, Inc. for their Series "560" Aluminum Sliding Glass Door (2-tracks) w/ wo Reinforcements — L.M.I., approved on 1012912020 and expiring on 06112123. E Sifang Zhao, P.E. Product Control Examiner NOA No. 20-0729.07 Expiration Date: June 12, 2023 E-2 Approval Date: November 26, 2020