HomeMy WebLinkAbout218674-1d compaction signedHeadquarters
1W C IL �
ENGINEERING
Mailing
11345 U.S. Highway 1
PO Box 78-1377
Sebastian, FL. 32958
1 %%
AND TESTING
Sebastian, FL. 32978
Orlando
Phone: 772-589-0712
723 Progress Way
SOIL COMPACTION REPORT
C.A.# 5693
Sanford, FL. 32771
ASTM D 1557 and ASTM D 6938
KSMengineering.net
DATE TESTED:
PERMIT #:
CONTRACTOR:
JOB LOCATION:
October 21, 2021
2102-0243
TNT Builders
151 Easy Street
Fort Pierce, Florida
KSM JOB #: 218674-1d/BS/ah
NUC # 528
Nuc Model: MC-IDR-P
Nuc Serial #: MD049528
ITEM TESTED:
Compacted Foundation Fill
TEST LOCATION
PEN
DRY MAX. DRY
PERCENT
DEPTH
OF SAMPLE
READ
DENSITY PROCTOR VALUE (P.C.F)
COMPACTION
1 N.E.
0" - 12" 40
107.8 109.2
98.7%
2 S.E.
1
108.5 "
99.4%
3 Center
1
107.6 "
98.5%
4 S.W.
1
108.9 "
99.7%
5 N.W.
1
108.1 "
99.0%
Soil Description:
Brown Sand
In Place Moisture:
8.8%
Proctor Optimum Moisture:
10.0 %
Proctor Max. Dry Density: P.C.F.
109.2
111.0 I I I I I I I
W I I I I I I I
E110.0 L..�.._.._..�.._.._..�..�.._.._.._
�
H109.0 �.. �.._.�_.. .._�. �.._.�._.._
T I I I I I
108.0 J.._.I— _I..J.. I_.._
P I I I I I
C 107.0 �..�.._.I +.._I._..�..�.._.I_.._
I I I I I I I
@ Test Locations the Density &
F 1060
Penetrometer readings indicate the
I I I I I I
Degree of Compaction Meets
I
105.0 L "T" "�" —I
Minimum Requirement
D I I I' f
for Unstaked Foundation
R I I I I I I I
104.0..�.._.i_..t.._i._..�..�.._.r_..�
Respectfully Sulitted:
Y 5 6 7 8 9 10 11 12 13
U g y
Moisture - % of Dry Weight
signed by
Thisitem has been electronically signed a"° Julie Keller
Disclaimer: Contractor is responsible to maintain the tested area
sealed by Julie Keller, P.E. FI. h,, 68366 on
the date stated directly t" the right using a
digital"gna - Date:
in the condition that KSM completed the indicated passed
Printed copies of this document are not
a"nsidered signed and seaied and the
compaction test. KSM is not responsible if the tested area has
-
at... must be y,,Ifi,d "n anyelectro"l` 2021.10.21
-Pt—
been altered from the approved inspected condition.
16:05:52
—04'00'
Julie E. Keller, P.E. President
PE# 68366 10/21/2021
Email to: St. Lucie County Building Department; tntbuildersllc@comcast.net
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Geotechnical Engineering - Construction
Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE