HomeMy WebLinkAboutENERGY CALCS & MANUAL J - 35 MONTEREY(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Typol688.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=41 1448.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c NIA R_ ft2 4. Number of Bedrooms 3 d. NIA R_ ft2 5. Is this a worst case? Yes 11. Ceiling Types (1750.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ft2 6. Conditioned floor area above grade (ft2) 1720 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA p= ft2 7. Windows(155.4 sqft.) Description Area 12. Ducts R ft2 a. U-Factor. Sgl, U=1.04 115.42 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 155 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems k$tulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.316 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor.(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA 9. Floor Types (1720.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2 b. Conservation features EF:0.970 b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.090 Total Proposed Modified Loads: 52.81 D PASS r Total Baseline Loads: 52.96 I hereby certify that the plans and specifications covered by this Review of the plans and -)IE 5, calculation are in compliance with the Florida Energy specifications covered by this ot Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: ' 3'2d Before construction is completed w DATE: this building will be inspected for - T compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance the Florida Energy Florida Statutes. , �S with Code.6'p�" .�T OWNER/AQ ENT:. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/13/2021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE ROYALE IMPA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot # Owner Name: Total Stories: 1 Block/Subdivlsion: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 90 Street WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes yes yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 it 0 343 W _ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' __ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft- __ 0 1 0 4Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft' ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft- -_- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft' --- 0 1 0 7SIab-On-Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft' ---- 0 1 0 111312021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 PnPRA Rdrlri_9n,2n IAIDI IT CI IRA REAGV f UIT wI 1�llim� MGVwnl FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ___ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 �_ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft2 286 ft2 Light N 0.6 No 0.7 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 11 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 N=>E Exterior Concrete Block - Int InsuBEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 2 S=>W Exterior Concrete Block - Int InsuBEDRGOM 4.1 29 0 8 0 232.0 ft2 0 0 0.4 0 3 W=>N Exterior Concrete Block - Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 S=>W Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 N=>E Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 N=>E Exterior Concrete Block - Int InsBEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 7 NE=>SE Exterior Concrete Block - Int InsBEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.4 0 8 E=>S Exterior Concrete Block - Int InsEKEDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 -9 SE=>SW Exterior Concrete Block - Int InsBIEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.4 0 10 S=>W Exterior Concrete Block- Int InsBEDROOM 2 4A 14 0 8 0 112.0 ft2 0 0 0.4 0 11 NE=>SE Exterior Concrete Block - Int Insul ENTRY 4A 1 5 8 0 11.3 ft2 0 0 0.4 0 1/13/2021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPl1T SIIMMARV r41PCtlI IST 1Z1G0n0T WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 12 EIS Exterior Concrete Block - Int Insul ENTRY - 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 _13 S=>W Exterior Concrete Block- Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft- 0 0 0.4 0 _14 N=>E Exterior Concrete Block - Int Insd8REAT/DINI 4.1 28 0 8 0 224.0 W 0 0 0.4 0 15 W=>N Exterior Concrete Block - Int Insd6REAT/DINT 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 16 N=>E Exterior Concrete Block - Int InsBEDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 17 N=>E Garage Frame - Wood BEDROOM 3 11 30 8 240.0 fN 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>S Insulated ENTRY None .32 3 6 8 20 ft' WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>N 3 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft' 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 SSW 4 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in None None 3 E=>S 8 Metal Low-E Single Yes 1.04 0.29 N 23.2 ft2 1 ft 0 in 1 ft 5 in None None 4 N=>E 14 Metal Low-E Single Yes 1.04 0.29 N 36.8 ft' 1 It 0 in 1 ft 5 in None None 5 W=>N 15 Metal Low-E Single Yes 1.11 0.27 N 40.0 W 10 ft 0 in 1 ft 5 in None None 6 N=>E 16 Metal Low-E Single Yes 1.04 029 N 16.2 ft' 1 It 0 in 1 ft 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 ft' 300 ft' 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.07 165.35 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 1/13/2021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPLIT SUMMARY CHFrtKI 14ZT RFonOT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply— V -- Return — Air CFM 25 CFW5 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 155 ft2 Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling (D0� Jan Feb Ven Heating Jan Feb Mar Mar Apr Apr € May Jun Jul May Jun Au Se Oct Nov Dec [ ] Jul Aug Sep Occtt X Noovv Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. Oft- Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 03 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(81bs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8lbs/sq.ft. ft2 it 0.3 BEDROOM 2 Default(81bs/sq.fL ft2 ft 0.3 ENTRY Default(8 lbs/sq.ft. ft2 it 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 GREAT/DINING Default(8 lbs/s.ft. ft2 ft 0.3 BEDROOM 3 1/132021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-pemjeable insulation shall requirements q The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within Comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spat as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. in addition, inspection or jog wars snan oe in accordance with the provisions or ICC-400. 1/13/2021 3:17 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE; FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1448.70 ft= b. Frame - Wood, Adjacent R=11.0 240.00 W 3. Number of units, if multiple family 1 c. N/A R= fF 4. Number of Bedrooms 3 d. N/A R= fP 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ft= 6. Conditioned floor area (ft=) 1720 b. Knee Wall (Vented) R=19.0 30.00 W 7. Windows'* Description Area c. N/A R= ft= a. U-Factor: Sgl, U=1.04 115.42 fF 12. Ducts, location & insulation level R ft= SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 155 b. U-Factor: Sgl, U=1.11 40.00 ft- SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft. a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A g= SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.316 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15. Hot water systems a. U-FactogAVG): N/A a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.97 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft= b. N/A R= ft= Credits (Performance method) None c. N/A R= W I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features,___-- Builder Signature: Date: Address of New Home: ty/FL Zi Ci p: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 3:16 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 - - wrightsoft' Project Summary �1 Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LN., FT.. PIERCE, FL 34946 Pnre: 772466-6799 Fax 772-466�796 Email: QUICKCALCS@AOL.COM Project• • For. WYNNE DEVOLPMENT THE ROYALE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF DesignTD 28 OF Design To 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19529 Btuh Structure 16243 Btuh Duds 5998 Btuh Duds 9055 Btuh Central vent (0 dim) 0 Btuh Central vent (0 clim) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Bluh Piping 0 Btuh Equipment load 25527 Btuh Use manufacturers data In Rate/swingg multipplier Equipmentsensibleload 0.95 Infiltration 24033 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2135 Btuh 2�0 Cenntr-al vent (0 cfm) BBtuh Heatingg Area(fI2) Cool' (none) 1608 1608 Equipment latent load 4603 Stun Volume(113) 15336 15336 Airchanges/hour 0.38 0.20 EquipmentTotal Load (Sen+Lat) 28635 Btuh Equiv.AVF (cfm) 97 51 Rea. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Cartier Make Carver Trade CARRIERAIRCONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 Cond 25HBC536A'030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47'F Latentcooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cfin Actual airflow 1160 cfin Airflowfactor 0.045 dm/Btuh Airflowfador 0.046 ctrn/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point= 34 OF Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Al.t..M1- wrighiso 2021Jan1308:1a22 A FM • • Rigf-Sdte@Uriveml20l9l9.021 RSU08101 Page 1 ...0 rfs\Wrigitoft HVAC\WYNNEDEV-THEROYALE.np Calc=M18 Fmrt Doorfaces: N wrightsofC Right-J@ Worksheet Jdx Entire House By QUICK CALCS, INC. ey. 317ST.LUCELN.,FT..PIEPCE,FL34946Pf m:772466-6799F.T246"796 Email: OUICKCALCS@{10L.00M 1 Room name Entire Houma BEDROOM 2 E osedwall 1762 It 32A It 3 Room height 9A It d 9.4 2 heatlmol 4 Room dimensons 14.0 x 18A ft 5 Roomarea 16315 W 252.0 IF Ty Corshuchon U-Vzdue Or HTM Area tF) Load Area Load number (B !hffl n (BWtviRj or perm er (11) (BWh) or perim er (1) (BMh) Hea[ Cad Gros NIPS Heat Cool Gros NIPS Heat C001 6 1pl 134-0ors 0.143 re 4A0 2.55 517 468 1835 1166 0 0 0 0 11----DG 1Acllw 1270 re 3556 70A3 38 0 1344 2662 0 0 0 0 1100 0.390 re 1092 1131 21 21 229 238 0 0 0 0 W 13A-4= 0.143 w 4A0 255 150 130 522 332 0 0 0 0 11 1—G IA -clam 1270 w 3556 7095 20 0 711 1419 0 0 0 0 w 13A4= 0.143 s 4m 255 40 40 160 102 0 0 0 0 w 13A-4ots 0.143 sw 4.00 255 395 395 1581 1005 169 169 677 431 13A-4= 0.143 nw 4D0 255 320 258 1034 657 132 108 432 275 1Ao1an 12M nw 3556 70A3 38 0 1344 2662 0 0 0 0 1At1an 1270 rwv 3556 4524 12 0 415 528 12 0 415 - 528 1A-dom 1270 rao 3556 4524 12 0 427 543 12 0 427 543 P 12C-09N 0.091 - 2,55 120 235 235 599 302 0 0 0 0 C 16A30md 0.032 - 0.90 232 1632 1632 1462 3785 252 252 226 585 F 22A-6N 0-089 - 27.69 0.00 1632 176 4878 0 252 32 886 0 6 c) AED exa w 0 154 Ervelope loss/gain 16540 15400 3063 2515 12 a) Nitration 2989 843 632 178 b) Roomsentilation 0 0 0 0 13 Nltertlel gains Oaupan5@ 230 0 0 0 0 Appliances(other 0 0 SubbAal(lirles6to13) 19529 16243 36M 2593 Lese)dBmalbad 0 0 0 0 Lesstran5er 0 0 0 0 Redistribution 0 0 0 0 14 SubM1 19529 16243 3596 2693 15 Dudloads 31% 56% 5998 9055 31% 56°/ 1135 1501 Total room bad 25527 25298 4831 4194 Par required (Qm) 1160 1160 220 192 Calculation approved byACCA to meet all requirements of Manual J 8th Ed. -l�.F wrighboT[- Jart1308- .4A RgttSuka&Uriversa1201919.021 RSU2021 08101 Page 1 -.unerts\WdgHsoft HVAQWYNNEDEV-THERO)ALEnp Calc=MIS Fmr[Dooria=N wrigbWoW Right-JO Worksheet Job.' Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone:772-466-6799 Fax: 772-466-6796 Emil: OUICKCALCS@40LCOM 1 Room name WIC MASTER BATH 2 Elrposedxall 0 ft 9D ft 3 Room height 9.4 ft heaYbool 9.4 It heaticool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 9.0 It 5 Room area 63.0 T 63.0 1F Ty Construction U-value Or HTM Area (IF) Lced Area Load number (BUhTeL.9 or perimeter (ft) (Biuh) or penmeetar (ft) (BWh) Hea[ Cool Gross NJP/S Heat Cool Gross NiPS Heat Cool 6 Vy 1344o s 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 II_—G D 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 13A-0acs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 1Aclom 1270 s 3556 70.95 0 0 0 0 0 0 0 0 W 13A-4= 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 W 13A4ors 0.143 w 4.00 2.55 0 0 0 0 85 85 339 215 13A-4ors 0.143 rw 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 3556 70.43 0 0 0 0 0 0 0 0 IA -Mom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 IA -Mom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 P 12C-Ow OA91 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 22A-tol 0.989 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AED e=rson -15 43 Emelopeloss(gain 56 131 644 319 12 a) Infiltration 0 0 178 50 b) Roomwmlation 0 0 0 0 13 Irremal gains: Omlpants@ 230 0 0 0 0 Applianoes(oUer 0 0 Subbtal(lines6to13) 56 131 822 369 Lesextemalload 0 0 0 0 Lestransfer 0 0 01 Redistnbulicn 0 0 0 0 14 Subtotal 56 131 822 369 15 DudlOads 31% 560/6 17 73 31% 565/c 253 206 Total mom load 74 204 1075 576 Air required (dm) 3 9 49 26 Calculations approved byACCAto meet all requirements of Manual J 8th Ed w rFr wry r+tsore- .i...,..._.,,._,_, 2021-Jan-1308:1422 Rgtt-S HE RO)ALE. 1201919A21 RS ortDo Page 2 ...urervslWngFlnft HVACiWYI4NE DEV-iHE R01ALE.np Calc=M18 FrortDoorfaoss:N ►�t wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Faz 772-466-6796 Email: QUICKCALCS@AOLCOM 1 Room name MBATH KrrCHEN 2 EVosedvMl 8.0 ft 8.0 It 3 Room height 9.4 ft heat/cool I 9.4 ft heaUmol 4 Room dimensons 7.0 x 8.0 ft 1.0 x 192.0 It 5 Room area 56.0 1F 192.0 11 Ty Construction U-value Or HTM Area (ft') Load Area Load number (BIuh1F2FF) (BluhAn or perimeter (ti) (Btuh) or perimeter (ft) (BWh) Heat Cool Gros N/PS Heat Cool Gross NIPS Heat Cool 6 13AA= 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 11DO 0390 ne 1092 1131 0 0 0 0 0 0 0 0 V�/ 13A-4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 L—C 1Aciam 1270 se 35.56 70.95 0 0 0 0 0 0 0 0 W 13A-4= 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 W 13A-4= 0.143 sw 4.00 255 75 75 301 191 0 0 0 0 13A-4= 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 3556 70.43 0 0 0 0 0 0 0 0 1Aclom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1Aclom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 2S5 128 0 0 0 0 75 75 192 96 C 16A-30md 0.032 - 0.90 232 56 56 50 130 192 192 172 445 F 22A-t )l 0989 - 27.69 0.00 56 i I a 222 0 192 8 222 0 6 c)AED e=rson -38 -56 Envelope loss/gain 573 283 585 486 12 a) Infiltration 158 45 0 0 b) Roomventilation 0 0 0 0 13 Internal gains: O=pan5@ 230 0 0 0 0 Appliance.4other 0 0 SubUNal(Iinestito 13) 731 328 595 486 Lesextemalload 0 0 0 0 I.esstransfer 0 0 0 0 Rediatibuton 0 0 0 0 14 Subtotal 731 328 585 486 15 Duct loads 31% 56% 224 183 31% 56% 180 271 ToW room toad 955 511 765 756 Air required (drn) 43 23 35 35 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed -r k- wVjwft so 2021 Jan-1308:1422 Right-SuteOUnversa1201919.021 RSU08101 Page 3 ...uneribAWdgttsoRHVACIWYNNEDEV-THEROYALE.np Calc=M18 FrortOoorfaces:N wrghtwft- RighWO Worksheet Jab: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN.,Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: QUICKC4LCMAOLCOM 1 Room name 2 BATH BEDROOM2 E1posedwall 5.0 it 302 It 3 Room height 9.4 It heaHmol 9.4 ft heaV=l 4 Raom dimenaons 5 Room area 9A x 5.0 ft 7.0 x 1905 ft 45.0 K 1905 fl' Ty Construction U-value Or HTM Area Load Load number (BWh4tz°� (BuhW) or perimeter (ft) (.h) or�penmetar (ft) (Btuh) Heat Cool Gros NWPIS LFieat I Cool I Gross NrP/S Heat Cool 6 W 13A4s 0.143 ne 4.00 2S5 47 47 188 120 141 141 565 359 IL--DGa tAclom 127C ne 3556 70.43 0 0 0 0 0 0 0 0 11DO 0.390 ne 1092 11.31 0 0 0 0 0 0 0 0 13A-0os 0.143 se 4.00 2.55 0 0 0 0 94 74 296 188 11 1Aclom 1270 se 3556 70.95 0 0 0 0 20 0 711 1419 W W 13AAors 13A-4ocs 0.143 0.143 s sw 4.00 4.00 255 2.55 0 0 0 0 0 40 40 160 102 13A-0os 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 9 0 9 38 0 24 1Acom 1 1270 nw 3556 70.43 0 0 0 0 0 0 0 0 0 1A-clom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 0 1Aclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 255 128 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 45 45 40 104 191 191 171 0 442 F 22A-tpl 0989 - 27.69 0.00 45 5 138 0 191 30 835 0 6 c)AED exnnson 1-21. 145 Envelope loss/gain 367 198 2775 2679 12 a) Infiltration 1 99 28 598I b) Roommentilatipn 0 0 0 13 Internal gains: O=Pants@ 230 0 0 0 ApPlian�,lother 0 Subtoel(lines6to13) 466 226 3373 Lesexemalload 0 0 0 1-mtransfer 0 0 0 Redistribution 0 0 0 14 Subtotal 466 226 3373 15 Ductloads 31% 56% 143 126 31% 56% 1036 1587 ToW room load 609 352 4409 gg34 Air required (dm) 28 16 200 203 Calculations approved bvACCA_ to meet all requirements of Manual J 8th Ed - ► wrt9�+rsvrC` 2021Jan,1308:1422 RighlSuite@Unver&a12O1919.021 RSU08101 Page ...0 rtslWdghsoft HVAaWYNNEDEV-THEROW.LE.np Calc=M78 FrortDoorfam:N wrightso& RighW@ Worksheet Job; Entire House Date: QUICK CALCS, INC. BY 317 ST. LUCIE UN., Fr. PIERCE, FL 34W Ptona: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name ENTRY LAUNDRY vu6l 16A ft 3.0 ft 3 Room height 9.4 ft heatl000i 9.4 ft heaVoaoi 4 Room dimensone 6.0 x 10.0 ft 7.0 x 6.0 ft 5 Room area 60.0 R 42.0 T Ty Construr5on U-Value Or HTM Area Load Area(� aperimeter Load number hJI (BbF°F) (BWW) or perimeter (ft) (BWh) or (it) fth) Heat Cool Gros WP/S Heat Cool Gros NrPS Heat Cool 6\J�j13AAors 0.143 ne 4.00 2.5E 0 0 0 0 0 0 0 0 1Aclom 1270 ne 35.56 70.43 0 0 0 0 0 0 0 0 11DO 0.3% ne 1092 11.31 0 0 0 0 0 0 0 0 Uf/ 13A� 0.143 se 4A0 2S5 56 56 226 144 0 0 0 0 11 L-G 1Actam 1270 se 35.56 70.95 0 0 0 0 0 0 0 0 W 13A4os 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 W 73A4ots 0.143 sw 4.00 2.55 0 0 0 0 56 56 226 144 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 35M 70.43 0 0 0 0 0 0 0 0 1Aclom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 tAc7om 1270 nw 3556 4524 0 0 0 0 0 0 0 0 P 12C-0w 0.091 2.55 128 94 94 240 121 66 66 168 84 C 16A-30md 0.032 - 0.90 2.32 Sc 60 64 139 42 42 38 97 F 22A-tol 0.989 - 27.69 0.00 60 16 443 0 42 13 360 0 6 c)AED excursion -45 -37 Enselope loss/gain 962 358 791 288 12 a) IMltration 119 33 9 33 b) Room vErlAlafion 0 0 0 0 13 Internal gains: Omrpan5@ 230 0 0 p Appliances/other p 0 0 Submtai (lines6to 13) 1081 391 910 322 Lese#emal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 14 Subtotal 1081 391 90 0 322 15 DUCloatls 31% 56% 332 218 37% 56% 279 79 179 179 Total room load 1413 610 11 5 Air required(cfm) 64 28 54 23 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed .9 A -F�t wrlgtrtisof!- 20214a 1308:1422 RiEV-THE RO)ALrsal20Calc= 21 RSU08101 -.unerm9WrigFEoft HVAC\WVNNE DEV-THE ftO`LALE.ny CaIc=NJB Fmrt Doorfaoes: N Page wrightsoft° Right-J® Worksheet Job; Entire House Date: QUICK CALCS, INC. By. 317ST.LUCIELN,Fr.PIERCE,FL34946PFore:772-466-6799 F=772-46"796 Email:QUrXC1LLCS@AOL.COM 1 Rcom name Sr TINGROOM GREATAMING 2 Fed call 30.0 It 25D ft 3 Room height 9.4 it heaNmol 94 ft he,*DOI 4 R. dim.... 20D x 10.0 ft 1D x 46&0 ft 5 Room ales 200D fF 468.0 1F Ty Construc5on U-%slue or HTM Area number (BW ffl'*n (BWhin w penm� (t) (BWh) ww penmetar (ft) (BWh) Heat Cool G. NIPS Heat Cool pas I NIPS Heat Cool 6 fly`D ocs 13A-4 0.143 ne 4.00 2M 94 73 292 186 235 197 - 790 502 �G 1Ac1om 12M ne 35M 70A3 0 0 0 0 38 0 1344 2662 11DO 0390 ne 10.92 1131 21 21 229 238 0 0 0 0 lq/ 13A-flocs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 1t L—C 1A-dw 1270 se 3556 70.95 0 0 0 0 0 0 0 0 W 13A4= 0.743 s 4DO 255 0 0 0 0 0 0 0 0 W 1344as 0.143 sw 4DO 255 0 0 0 0 01 0 0 0 13A4= 0.143 rw.• 4DO 2.55 188 150 601 382 0 0 0 - 0 Ti IA-clom 1270 nw 3556 7D.43 38 0 13" 2562 0 0 0 0 1A-d= 12M m 3556 4524 0 0 0 0 0 0 0 0 1ACIM 1270 w 3556 4524 0 0 0 0 0 0 0 0 P 12C-0sry 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md OD32 - 090 2.32 2DO 200 179 464 468 468 419 1086 F 22A4ol 0.ce9 - 27.69 Om 200 30 831 0 468 25 692 0 6 c)AED�on 402 1 -440 Enuelopeltssbain 3477 4334 3245 3810 12 a) Irditraton 593 167 494 139 b) Rcomventilaticn 0 0 0 0 13 htemalgaim Oozrpartls@ 230 0 0 0 0 Appliancedofher 0 0 Sublofal(lirles6to13) 4070 4501 3739 3950 Lessommalload 0 0 0 0 Lestransfer 0 0 0 0 RedL*ibubon 0 0 0 0 14 Subtrral 4070 4501 3739 3950 15 Ductloads 31% 66% 1250 2509 31% 56°k 1148 Z202 Total room load 1 5320 7010 4888 6151 Air required(cfm) 242 321 222 282 Calculations approved bvACCAtD meet all requirements of Manual J 8th Ed. -r- wrll9ht cvrr- 2021JaM308:1422 AC►c.C.A RgttSUte®Urvw=1201919.021 RSU08101 Page _rmer151W6grtoft HVAC1WYNNEDEV-THERO`6LLE.np Calc=Ml8 Fmwt Doorface N - wrightsoft• Duct System Summary Jdx : Entire House 6y., QUICK CALCS, INC. 317 ST. LUCIE UN, Fr PIERCE, FL 34946 PtZm: 772466-6799 Fa 772-466-6796 Emil: OUICKGLLCS@AOL.COM Project• • For. WYNNE DEVOLPMENT THE ROYALE, FT. PIERCE, FL 6demal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowestiddon rate Actual airflow Total efective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100fl 1160 cff n 0 it Supply Branch Detail Table Cooling 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1160 cfrn Name Design (Bluh) Htg (cim) Clg (Gfrn) Design FIR Diam (n) H x W (In) Dud Mat A tual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 352 28 16 0 0 OxO ShMt 0 0 BEDROOM h 2097 110 96 0 0 0x0 ShMt 0 0 BEDROOM2 c 2217 100 102 0 0 Ox0 ShMt 0 0 BEDROOM2-A c 2217 100 102 0 0 OxO ShMt 0 0 SEDROOM,A h 2097 110 96 0 0 Ox0 ShMt 0 0 Ems' h 610 64 28 0 0 OxO ShMt 0 0 GREATONING c 3076 111 141 0 0 0x0 ShMt 0 0 GREAT/DMING-A c 3076 111 141 0 0 Ox0 ShMt 0 0 KnCFEN c 756 35 35 0 0 OxO ShMt 0 0 LAUNDRY h 501 54 23 0 0 OxO ShMt 0 0 ".BATH h 511 43 23 0 0 Ox0 ShMt 0 0 MASTERBATFI h 575 49 26 0 0 0x0 ShMt 0 0 srmNG ROOM c 3505 121 161 0 0 Ox 0 ShMt 0 0 SrmNG ROOM.A c 3505 121 161 0 0 Ox0 ShMt 0 0 WIG c 204 3 9 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (cflT1) TEL (ft) Design FIR Veloc (ipm) Diam (in) H x W (n) Stud/Joist Opening (in) Dud Mat Trunk r1C1 OxO 1 1160 1160 0 0 0 0 Ox 0 ShMt Wrightson' 2021-1a 1308:1423 ...-.....-, RgflSiile4JUri�1201919A21 RSU08101 ACC Piet ...imerisiWrigf6oR FNAQWYNNE DEV-TI-�RO`01LEn.p Calc=M18 FrortDcorfa®s:N