Loading...
HomeMy WebLinkAboutENERGY CALC & MANUAL J - 6724 LILA(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: GEMINI IMPACT BuiiderName: WYNNE BUILDING CORP. Street: PermitOrfice: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner: Jurisdiction: DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(1763.8 sgft_) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1507.80 ft2 3. Number of units, if multiple family 1 b. Frame -Wood, Adjacent c NIA R=11.0 256.00 ft2 4. Number of Bedrooms 2 d. NIA R= ft2 R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1839.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1839.00 ft2 6. Conditionedfloor area above grade (ft2) 1839 b. NIA R= ft2 Conditioned floorarea below grade (ft2) 0 c. NIA R= ft2 7. Windows(155.3 sgft.) Description Area 12. Ducts R fe a. U-Factor: Sgl, U=1.02 115.28 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.27 b. U-Factor: Sgi, U=1.11 40.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central knit 34.8 SEER:15.00 c. U-Factor. NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.318 ft. 14. Heating systems kStu/hr Efficiency Area Weighted Average SHGC: 0.270 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 SHGC(AVG): NIA 15. Hot water systems 9. FtoarTypes (1839.0 sgtt.) Insulation Area a. Electric Cap:40gallons a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 b. Conservation features EF. 0.950 b. NIA R= ft2 None c. NIA R= ft2 16.Credits None Glass/FloorArea: 0.084 Total Proposed Modified Loads: 51.52 Total PASS Baseline Loads: 52.96 hereby certify that the plans and specifications covered by this calculation are in Review of the plans and compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance O PRE=PARED BY: with the Florida Energy Code. s rr„�4,';',;r ,� DATE: 1-1 -2 21 Before construction is completed this building will be inspected for compliance with Section 553.908 hereby certify that this building, as designed is in compliance with the Florida Energy Code Florida Statutes_ * Q OWNERA ENT BUILDING OFFICIAL: DATE. DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/13/2021 7:44 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: GEMINI IMPACT Bedrooms: 2 Address Type: StreetAddress Building Type: User ConditionedArea: 1839 Lot OwnerName: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: SuilderName: WYNNE BUILDING CORP. RotateAngle: 270 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / DesignLocakm Design Temp TMY Site 97.5% 2.5% Int Design Temp Winter Summer Heating Design Daily Temp DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1839 14712 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 MASTER BEDROO 256 2048 No 0 1 1 Yes Yes Yes 6 ENTRY 83 664 No 0 1 Yes Yes Yes 7 LAUNDRY 42 336 No 0 1 Yes Yes Yes 8 GREAT/DINING 568 4544 No 0 1 Yes Yes Yes 9 CLOSET2 56 448 No 0 1 No Yes Yes 10 BATH 2 48 384 No 0 1 Yes Yes Yes 11 POWDER 42 336 No 0 1 No Yes Yes 12 SITTING ROOM 110 880 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet " 1 Slab -On -Grade Edge Insulation BEDROOM 43ft 0 343ft _-_- 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1ft 0 63 ft' ---- 0 1 0 3 Slab-On-GradeEdge Insulation M.BATH 8ft 0 56 ft' ---- 0 1 0 4 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 172 ft' ---- 0 1 0 5 Slab -On -Grade Edge Insulation MASTERBEDRO 51ft 0 256W ---- 0 1 0 1/13/2021 7:44 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INF'U I JUMMAKY UMtI;KLIJ 1 KtF'UK I FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 6SIab-On-GradeEdgelnsulation ENTRY 7ft 0 a3 ft2 -_-- 0 1 0 7 Slab-On-GradeEdgelnsulation LAUNDRY Eft 0 42 1`12 ____ 0 1 0 8 Slab-On-GradeEdge Insulation GREATIDINING 39It 0 568 ft. ____ 0 1 0 9 Slab-On-GradeEdgelnsulation CLOSET2 1ft 0 56 ft2 -___ 0 1 0 10SIab-On-GradeEdge Insulation BATH 8ft 0 48ft ____ 0 1 0 11SIab-On-GradeEdgeInsulation POWDER 1 ft 0 42 ft2 ____ 0 1 0 12SIab-On-GradeEdge Insulation SITTING ROOM 22It 0 1101t2 --__ 0 1 0 ROOF Roof Gable Roof Red Solar $A Emitt Emift Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1938 ft' Oft' Light N 0.6 No 0.7 No 0 18.43 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fullattic Vented 150 1839 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63 ft' 0A Wood 3 UnderAttic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 UnderAttic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 UnderAttic(Vented) MASTER BEDRO 30 Blown 256 ft2 0.1 Wood _ 6 UnderAttic(Vented) ENTRY 30 Blown a3 ft2 0.1 Wood 7 UnderAttic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 8 UnderAt6c(Vented) GREAT/DINING 30 Blown 568ft 0.1 Wood _ 9 UnderAttic(Vented) CLOSET2 30 Blown 56 fF 0.1 Wood 10 UnderAtric(Vented) BATH 30 Blown 48 ft2 0.1 Wood 11 UnderAttic(Vented) POWDER 30 Blown 42 ft2 0.1 Wood 12 UnderAttic(Vented) SITTING ROOM 30 Blown 110 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 S=>E Exterior Concrete Block- Int lnsul BEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.4 0 _ 2 W=>S Exterior Concrete Block- Int lnsul BEDROOM 4.1 14 0 8 0 112.0ft 0 0 0.4 0 _3 S=>E Exterior Concrete Block -Int lnsul M. BATH 4.1 8 0 8 0 64.0ft 0 0 0.4 0 4 N=>W Exterior Concrete Block- Int InsuMASTER BE 4.1 24 0 8 0 192.0 ft2 0 0 0.4 0 1/1a/2021 7:44 AM 7.0.00- FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below S E=>N Exterior Concrete Block- Int lnsuMASTER BE 4.1 13 0 8 0 104.0ft- 0 GA 0 _6 S=>E Exterior Concrete Block- Int InsuMASTER BE 4.1 14 0 8 0 112.0ft2 0 0 0.4 0 7 E=>N Exterior Concrete Block-Intlnsul ENTRY 4.1 6 0 8 0 48.0 ft= 0 0 0.4 0 -8 S=>E Exterior Concrete Block -Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 9 S=>E Exterior Concrete Block - Intlnsul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 10 N=>W Exterior Concrete Block- Int lnsu)GREAT/DINI 4.1 30 0 8 11 267.5 ft2 0 0 0.4 0 11 W=>S Exterior Concrete Block -Int lnsuK3REAT/DIN1 4.1 9 0 8 11 80.3W 0 0 0.4 0 12 N=>W Exterior Concrete Block-Intlnsul BATH2 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 13 N=>W Exterior Concrete Block- Int lnsuBITTING RO 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 14 S=>E Exterior Concrete Block- Int lnsuISITTING RO 4.1 1 0 8 0 8.0 ff2 0 0 0.4 0 15 W=>S Exterior Concrete Block -Int lnsuSITTING RO 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 16 N=>W Garage Frame -Wood KITCHEN 11 32 8 266.0 ft2 0.23 0.4 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 E=>N Insulated ENTRY None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 W=>S 2 Metal Low-ESingle Yes 1.02 0.27 Y 32.4 ft2 i ft 0 in 1 It 4 in Drapes/blinds Exteriors 2 S=>E 3 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 ft2 1 It 0 in 1 ft 4 in None None 3 E=>N 5 Metal Low-ESingle Yes 1.02 0.27 Y 32A ft2 1 ft 0 in 1 It 4 in None None 4 N=>W 10 Metal Low-ESingle Yes 1.02 0.27 Y 18.4 ft2 1 fit in 1 ft4 in None None 5 WaS 11 Metal Low-ESingle Yes 1.11 0.27 Y 40.0 ft2 10ft0in 1It4 in None None 6 N=>W 12 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 f12 1 ft0 in 1 ft4 in None None 7 W=>S 15 Metal Low-ESingle Yes 1.02 0.27 Y 18A fN 1ft0 in 1ft4in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 320 ft2 320 ft 32 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1226 67.26 126.28 .0902 5 1/13)2021 7:44 AM 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40gal 60.9gal 120deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS / —Supply— —Retum— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 125 111112 Attic 40 ft2 DefaultLeakage Attic (Default) c(Defauft) c 1 1 TEMPERATURES Programable[[Thermostat:[ Ceiling Fans: ��N [[ ]] Heating H Jan H Feb N Mar [[ ] [] Apr r �0 D0 I May 1 i Jun n Jul [X� [ t Aug [X� L 1 Sep [ ] OctOct Venting II IIJan [( II Feb [(�x11 Mar ta7 I I 1 Jun I I Jul I 1 Aug L 1 Sep l l lxl X Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) 78 78 78 78 78 78 PM 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness FumitureFraction Space Default(81bs/sq.ft. 0 ft. 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft ft2 ft 0.3 M. BATH Default(8lbs/sq.fL fI2 ft 0.3 KITCHEN Default(81bs/sq.fL ft. ft 0.3 MASTER BEDROO Default(8lbs/sq.ft ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(81bs/sq.ft. W ft 0.3 GREATIDINING 1/13/2021 7:44 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R406-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness FumdureFraction Space Default(8 lbs/sq.ft. ft' ft 0.3 CLOSET 2 Default(8lbs/sqft ft' It 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 It 0.3 POWDER Defaul 8lbs)s .fL ft. ft 0.3 SITTING ROOM 1/1312021 7:44 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) CompliantSottware Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GEMINI IMPACT Builder Name: WYNNE BUILDING CORP. Street Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL . Permit Number: U Owner: Jurisdiction: w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids an(] walls or ceiliring, _.... ___.__.., .....r................a -- — — —,,, --rai me M, ; i u,c yioviswus ui iuc;, uu. 1/13/2021 7:45 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 97 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1507.80 ft' b. Frame - Wood, Adjacent R=11.0 256.00 f12 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. WA R= fe 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1839.00 fF 6. Conditioned floor area (W) 1839 b. WA R= fp 7. Windows" Description Area c. N/A R= ft- a. U-Factor. Sgl, U=1.02 115.28 fF 12. Ducts, location & insulation level R IF a. Sup: Attic, Rat Attic, AH: Attic 6 125 SHGC: SHGC=0.27 b. U-Factor. Sgl, U=1.11 40.00 ft- SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft- a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor. WA ft 14. Heating g systems kStu/hr Efficiency Area Weighted Average Overhang Depth: 3.318 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.270 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): WA ft- a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1a39.00 ft' b. NIA R= ft2 Credits (Performance method) None c. WA R= ft- I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: q City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 7:45 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project Summary D«1: wrightsoft ry By. Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Pl w772466-6799 Faz 77246&6796 E.l: OUICKCALCS AOL.COM i Project Information For. THEGEMINI WYNNE DEV., FT. PIERCE, FL Notes: Design Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 'F Outside db 90 °F Inside db 70 OF Inside db 75 OF Design TD 28 'F Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21011 Btuh Structure 19448 Btuh Ducts 6289 Btuh Duds 9502 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfrn) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27300 Btuh Use manufacturers data n Rate/swing multiplier Equipment 0.95 Infiltration sensible load 27502 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2170 Btuh Duds 2599 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Coolingq (none) (fit") 1839 183J Equipment latent load 4768 Btuh Volume (fP) 15582 15582 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 32271 Btuh Equiv.AVF (cfrn) 99 52 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536KO30 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point= 36 OF E:M.=W19 34600 Btuh @ 47-F 1160 clin 0.042 cfm/Btuh 0.50 in H2O Bacicup: Input=7kW, Output=23009Btuh. 100AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A 030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfin Air flow factor 0.040 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.86 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wri9htsoR^ 2021 Jan1307:4409 RigttSdfe®Unwma1201919.021 RSU08101 Pagel ...UICK1DOw r6\WdgNsoft HVAQW7NNE-GEMINInp Calc=NW Frord�orfaw IN F}J wrightsoft Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. ay. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 P1nre: 772-466-6799 Fax 772466-6796 Erreil: QU1CKCALCS@AOL.COM 1 Room name Enfire House MASTER BEDROOM 2 6posd wall 212.0 ft 43.0 ft 3 Room height 8.5 ft d 8.0 ft heaVmol 4 Room ol'U.ns 1.0 x 343.0 ft 5 Room area 1839D ft- 343.0 ft' Ty Construction U-value Or HTM Area (IF) Load Area (fF) Load number (BUhfllz°9 (BtuKd' or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross N/PS Heat Cool Gross NIPS Heat Cool 6 V 13A4o s 0.143 n 4.00 2.55 628 602 2412 1533 0 0 0 0 1AcNorn 1270 n 3556 34.77 7 0 247 241 0 0 0 0 L--GG 4A5-2om 0.770 n 2156 1931 19 0 407 365 0 0 0 0 13A-0ocs 0.143 a 4.00 2.55 152 98 394 250 0 0 0 0 11 1Acl m 1270 a 35M 8729 33 2 1162 2853 0 0 0 0 11D0 0390 a 10.92 11.31 21 21 229 238 0 0 0 0 W, 13A-4ocs 0.143 s 4.00 2.55 473 466 1868 1187 232 232 929 591 �G 1Actwn 1270 s 35M 34.77 7 7 247 241 0 0 0 0 13A4o s 0.143 w 4.00 2.55 295 203 813 517 112 79 318 202 to-clom 1270 w 35M 5525 33 2 1162 1806 33 2 1162 1806 4A5-2om 0.770 w 2156 44.72 19 2 407 845 0 0 0 0 4Ai20W 0.470 w 13.16 35.61 41 2 537 1453 0 0 0 0 P 12C-0sw 0.091 - 255 128 224 224 571 287 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 1839 1839 1648 4266 343 343 307 796 F I 22A-Ipl 0.989 - 27.69 EI I 0.00 1839 212 5871 0 343 43 1191 0 6 c)AEDe rsion 508 618 Emrelopelosstgain 17975 16592 3907 4012 12 a) hfiltrat. 3037 856 674 190 b) Roomlenfilafion 10 0 0 0 13 I L.1gain Owrpants@ 230 0 1 0 0 0 Applianoss/other 2000 0 Subtolal(Iines6W13) 21011 19448 4581 4202 Lesse)de=l load 0 0 0 0 LestrarsLr 0 0 0 0 Redishibubon 0 0 0 0 14 Subtotal 21011 19448 4581 4202 15` Duct loads 30% 49% 6289 9502 30% 49% 13711 2053 I Totl room load 27300 28950 1 5952 6255 Air required (dm) 1160 1160 253 251 Calculations approved bvACCAto meet all requirements of Manual J ft Ed Y� wr19>titisoft' 2021-JarF1307:44A9 RIgHSuteoarsa ®Uri1201919.021 RSU08101 -.UICKrpoc Tts\Wnghl ftHVAC\WYNNE-GEMINI.np Calc=M18 Aord Coorfaces: N Page wrightsofr Right -A) Worksheet Jam: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE UN., Fr.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-066-6796 Email: OIIICKCALC6@4OL.COM 1 Room name WIC M BATH 2 5mosedwall 0 It 8.0 ft 3 Room height 8.0 It heaHocol 8.0 ft heatlmol 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 It 5 Room am 63.0 iF 56.0 iP Ty Construcfion U-value Or HTM Area (ff) Load Area f8 Load number (Bbh4ti°F) (BWh4P) or perimear (ft) (Bbh) or penmet r (it) (Bt h) Heat Cool Gross NAPS Heat Cool Gras NAPS Heat Cool 6 13A4a 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 Yfl 13A-0as 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 IL--DG 1Aatom 1270 a 35.56 8729 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W, 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 �C 1Atlom 1270 s 35,56 34.77 0 0 0 0 7 7 247 241 vh13A4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1cm 1270 w 35.56 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0 4A5-2cvd 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 0.90 2.32 63 63 56 146 56 56 50 130 F 22A-ipl 0.9 - 27.69 0AO j� I 63 0 0 0 56 8 222 0 6 c)AEDe rsion -12 -47 Envelope losslgain 56 134 747 469 12 a) Infiltration 0 0 125 35 b) Rocmventldon 1 0 0 0 0 13 Internal gairs: Oocupzn4@ 230 I 0 0 0 0 Applimces(olher 0 0 Subtotal (fines 6to 13) 56 134 872 505 Lewedemalload 0 0 0 Lew iransbr 0 0 0 Retlistri6u5on 0 0 T12 0 14 Subbal 56 134 505 15 Ductloads 30% 49% 17 65 30% 247 Total room load 73 199 1133 751 Air required(cfm) 3 8 48 30 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed la-rk- wr�9�+LsorC' 2021J1 n1307:4499 k RWYNN -GEMINI.nuo Calc=.021 RSU08101 Paget ...UICKIDoamenSlWdgF�ftFNgC\WYNNE-GEMINI.np CaIc=M16 Frord Coorfaces: N i + wrightsoft RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-46"796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN WSTERSEDROOM2 2 Eposedwall 8A ft 5.0 It 3 Room height 8.0 It heatl000l 8.0 ft `I a ODOl 4 Room dimensors 1,0 x 172A It 1.0 x 256.0 It 5 Room area - 1720 ft2 256.0 IF Ty Construction U-value Or HTM Area Load Area Load number (BfuhM2-°F) (BlullF) or perimeter (ft) (BWh) or penmeter (ft) (Btuh) Heat Cool Gros NnPS Heat Cool Gross NIPIS Heat Cool 6 Vy 13A-4ocs 0.143 n 4.00 2-55 0 0 0 0 192 192 769 489 FL--GG 1Ac1om 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 13A4= 0.143 a 4.00 2.55 0 0 0 0 104 71 286 182 11 1Ac1om 1270 a 35.56 8729 0 0 0 0 33 2 1162 2853 11DO 0-190 a 1092 11.31 0 0 0 0 0 0 0 0 lM 13A-4ors 0.143 s 4A0 255 0 0 0 0 112 112 448 285 1-3 1Actom 1270 a 35.56 34.77 0 0 0 0 0 0 0 0 13A4olm 0.143 w 4.00 2,55 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 5525 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 2156 44.72 0 0 0 0 0 0 0 0 4A5-2o1N 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0 p 12C-09N 0.091 2.55 128 64 64 163 82 0 0 0 0 C 16A-30md 0.032 0.90 2.32 172 172 154 399 256 266 229 594 F 22A-1pl 0989 - 27.69 0.00 i 172 8 222 0 256 51 1412 0 6 c)AEDexcumon -211 -176 Envelope tose/gain 539 270 4307 4227 12 a) l lhauon 0 0 800 226 b) Rowmentilatim 0 0 0 0 13 Internal gains: Ooalpants@ 230 0 0 0 0 Appliano:Jother 2000 0 Subtotal(lines6to 13) 539 2270 5106 4452 Lesse)lamal load 0 0 0 0 I-Miransfer Iq3016 0 0 0 0 Redistibu on 0 0 14 Subtotal 539 2270 5106 4452 15 Dudloads I49% 161 1109 30% 49% 1528 2175 Total room load 700 3380 6635 6627 Airrequired (dm) 30 135 282 268 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -rid- 2021-JarF1307:4499 RWYNN e®Unversal201919.021 RSntDoor Page3 ...UICK1Donmer�\WrigHsafl HUAG\WYNNE-GEMINI.np Calc=rJJB FrorM1Door faces: N Fb wrightsoft° Right-M Worksheet Job'. Entire House Date: QUICK CALCS, INC. ey 317 ST. LUCIE LN.,Fr. PIERCE, FL 34946 P1ore: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 Exposedwall 20D It 13.0 it 3 Room height 8.0 R heaVmol 8.0 It heaV000l 4 Room dimensions 1.0 x 83.0 It 7.0 x 6.0 It 5 Roomarea 83D T 42D fF Ty Construction U-value Or HTM Area Load Area number (BWh4FF� ' (Btuh4F) or perimeettei M (BWh) or perimeter (R) (BWh) Heat Cool Gross NIP/9 Heat Cool Gross NfPS Heat Cool 6 Yr/ 13AAc s 0.143 n 4.00 2S5 0 0 0 0 0 0 0 0 1Ac1om 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 13A-4ors 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 11 1Ao1om 1270 a 3556 8729 0 0 0 0 0 0 0 0 D 11D0 0.390 a 1092 11.31 21 21 229 238 0 0 0 0 y/ 13A4s o 0.143 s 4.00 2.55 8 8 32 20 48 48 192 122 L--G 1Aciom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 w 3556 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 44.72 0 0 0 0 0 0 0 0 4A5.2oW 0.470 w 13.16 35.G1 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 - 2.55 128 104 104 265 133 56 56 143 72 C 16A30md 0.032 0.90 2.32 83 83 74 193 42 42 38 97 F 22A-tpl 0.989 - 27.69 0.00 I I I 83 20 554 0 42 13 360 0 6 c)AED exansion -58 -27 Enwlopelossrgain 1263 595 733 264 12 a) Vlfiltraton 110 31 94 27 b) Rcomsenblabon 0 0 0 0 13 Intemalgairs: O—park@ 230 0 0 0 0 ApplianoJother 0 0 Subfofal(lines6to13) 1372 625 827 291 Leseldemallcad 0 0 0 0 Leestlansfer I 0 0 0 0 Redistibuton I 0 0 0 0 14 Subfotal I 1372 625 827 291 15 Duct loads I 30% 49% 411 306 30% 49% 247 142 Tots[ room load 1783 931 1074 433 Airrequired(Cm) 76 37 46 17 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -r'Id-wrr9ft> crt- 2021-Jan.1307:4409 A k Ri91d-9uLOUri..1201919.021 RSU08101 Page ...UICK1Donrnerts\W6ghtmRHVAMWYNNE-GEMINI.np Calc=MJ8 Frcrdpoorfacex N wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phore: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/AOL.COM 1 Room name GREATIDINING CLOSET2 2 Exporedwall I 39.0 It O ft 3 Room height 8.9 It heaVmol 9.4 It heaVccol 4 Room dmermons 1.0 x 568D It 7.0 x 8.0 It 5 Room area 568.0 IF 56.0 IF Ty Construction U-value Or HTM Area (ft') Load Area two number (Mhdfl -F) (BbjW I or perimeter (ft) (at m) or perimeetter (ft) (BWh) Heat I Cool Gross N/P/S Heat Cool Gross NOS Heat Cool 6 VN 13A4a JU143) n 4.00 2S5 267 248 993 632 0 0 0 0 II--GG 1Ac1om n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om n 21M 19.31 19 0 407 365 0 0 0 0 13A ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 j 1A mom 1270 a 35.56 8729 0 0 0 0 0 0 0 0 �D 11DO 0.390 a 1022 11.31 0 0 0 0 0 0 0 0 W 13A-4ars 0.143 s 4A0 2.55 0 0 0 0 0 0 0 0 �G 1Actom 1270 s 35M 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 2.55 80 39 157 100 0 0 0 0 G 1Aciom 1270 w 35.56 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.61 41 2 537 1453 0 0 0 0 P 12C-Ow OD91 - 2.55 128 0 0 0 0 0 0 0 0 c 16A30md 0.032 - 0.90 2.32 568 568 509 1318 56 56 50 130 F 22A-tpl 0.989 - 27.69 0.00 568 39 1080 0 56 0 0 0 6 c)AED ewunion 256 -11 Envelope loss/gain 3684 4123 50 119 12 a) Infiltration 680 192 0 0 b) Roomsentilahcn 0 0 0 0 13 Intemalgains Ooalpanls@ 230 0 0 0 0 Applimossbther 0 0 Subtotal(lines6b13) 4364 4315 50 119 Les;exoemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4364 4315 50 119 15 Ductimcs 30% 49% 1306 2108 30% 49% 15 58 Total room Toad 5671 6423 65 177 Air required (dim) 241 257 3 7 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -rI+ wNgtitso, ft I&K Pj91*SuteOUriversa1201919.021 RSU08101 2021-Jan1307:4499Pages ...UICK�Doa ts\WdgFtwft HVAQWYNNE-GEMINInp Calc=MJ8 Frant Dss: eorfaoN r l wrightsoftRight-JO Worksheet yob: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., PT. PIERCE, FL 34M Phone: 772-466-6799 Fax 772-46"796 Emil: OUILKCALCS@A0L.00M 1 Room name WH2 POWDER 2 EVosed wall 8D It 0 ft 3 Room height 9A It heaHmol 9.4 8 heaU000l 4 Rcorn aimensons 6D x 8D It 7D x 6.0 ft 5 Room area 48.0 IF 4Z0 iF TY Consruclion U-Nlue Or HTM Area Load Am Load number (BWhflF°F� (EWhfit� or perimeter (10 (BWh) or pedm� (ft) (BWh) Heat Cool G. NAPS Heat Cool Gross NAPS Heat Cool 6 13A-0ots 0.143 n 4D0 2.55 75 68 273 174 0 0 0 0 1Ac1om 12M n 35.58 34.77 7 0 247 241 0 0 0 - - 0 4A5-2om 0.770 n 2156 1931 0 0 0 0 0 0 0. 0 Vr1 F—G 13A = 0.143 a 4.00 255 0 0 0 0 0 0 0 0 17 1Acl= 12M a 3556 9729 0 0 0 0 0 0 0 0 �p 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 t13A-4= 0.143 s 4D0 255 0 0 0 0 0 0 0 0 --G 1A-clom 1270 s 35M 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 w 4110 255 0 0 0 0 0 0 0 0 1AC1om 1270 w 3556 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0 4A52oW 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0 P 12C-Dw 0D97 2.55 128 0 0 0 0 0 0 0 0 16A-30nd 0D32 - 0.90 2.32 48 48 43 711 42 42 38 97 F I f 22A-lpl 0-w - 27B9 I� II l 0M 48 8 222 0 42 0 0 -0 6 c)AEDexalrson 48 -8 Envelope losIgai9 784 478 38 89 12 a) Inlilhallon 147 42 0 0 b) Rcom venlilaton 0 0 0 0 13 Irftmal gains: Oaupanls@ 230 0 0 0 0 Appiianos'other 0 0 Sub411al(lin 61o13) 932 520 38 89 Lesexensl load 0 0 0 0 Lestransier 0 0 0 0 RedistribuAon 0 0 0 0 14 Subtolal 932 520 38 89 15 Ductloads 30% 49% 279 254 30% 49% 11 44 Total room load 1211 72 49 133 Airrequired(dm) 51 31 2 5 Calculabons approved bvACCAto meet all requirements of Manual J 8th Ed -r k- wryOl o1L' 2021-Jan1307:44:09 .41 h RigitSdte®Uri*rsl201919.021RSU08101 Page ...UICKOoo r6lWdgtbnftWAC1WYNNE-GEMINinp Caic=M18 Frodl)oorfaws N >�t wrightsoftRighW@ Worksheet Job: Entire House y. B QUICK CALCS, INC. By. 317 ST. LUCIE LN.. Fr. PIERCE, FL 34946 Ptnre: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name j DEN 2 5posedvall 22.0 It 3 Room height 9.4 It headcool 4 Room dimensions 11.0 x 10.0 It 5 Room area 110.0 fF Ty Constuction U-value Or HTM Area (� Load Area Load number (BWi14[L°F) (BNhIIR) or cedmeter (It) (BWh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V 13A-0as 0.143 n 4.00 2S5 94 94 376 239 1Aclom 1270 n 3556 34.77 0 0 0 0 L�—GG 4A5.2om 0.770 n 2156 1931 0 0 0 0 13A4o s 0.143 a 4.00 2,55 0 0 0 0 11 1Aclom 1270 a 3556 8729 0 0 0 0 11DO 0390 a 10.921 1131 0 0 0 0 Vmil' 13A o s 0.143 s 4.00 2S5 9 9 38 24 1Aciom 1270 s 35M 34.77 0 0 0 0 13A-0ocs 0.143 w 4.00 2.55 103 84 338 215 11A lore 1270 w 35.56 5525 0 0 0 0 4A5-20m 0.770 w 21.56 44.72 19 2 407 845 4A5.2oW 0,470 w 13.16 35.61 0 0 0 0 P 12C-0ex 0.091 - 2.55 128 0 0 0 0 C 16A-30md 0.032 - 0.90 232 110 110 99 255 F I 22A-QII 0989 - 27.69 ODD 110 22 609 0 6 c)AED excusion lossigain 186812 a) IMihaJon 405b) Room ventilator, 013 t233Envelope Inkmalgains Ooarpants@ 230 0 Applian�otr:er Subtotal(lines64113) 2273 Lessexamalload 0 0 Les transfer 0 0 Redistribution 0 0 14 Subtotal 2273 1926 15 Duct loads 680 941 Total room load 2953 2867 Airrequired (am) 125 115 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed AC�rt� wrl9Mfso1'r- 2021-Jan1307:4499 A PogtYNNE-CGEMINI,5al V CaI 19.021 RSU08101 Page7 ...UICJODoamerislWdgFd�ftHJAC\WYNNE-GEMINI.rup CaIc=MJB Frond Doortaces N -- wrightsoft® Duct System Summary o bata: Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Pros: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information For. THE GEMINI WYNNE DEV., FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0250 in H2O 0.286 iN100ft 1160 cfm 175 Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0250 in H2O 0.286 iN100ft 1160 Dim! Name Design (Btuh) Htg (cfm) Cig (cim) Design FR Diam (in) HxW (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATM2 h 1211 51 31 0.368 4.0 Ox0 VIFx 21.0 115.0 st1 CLOSET2 C 177 3 7 0.363 4.0 Ox0 VIFx 22.6 115.0 st1 DEN h 2953 125 115 0.289 7.0 Ox0 VIFx 38.1 135.0 s12 ENTRY h 1783 76 37 0.485 4.0 Ox 0 VIFx 8.1 95.0 GREAT/DINING-A c 3211 120 129 0.300 6.0 0x0 VIFx 31.7 135.0 st2 GREAT/DINING-8 c 3211 120 129 0.308 6.0 Ox0 VIFx 27.3 135.0 s12 KITCHEN c 3380 30 135 0.376 7.0 Ox0 VIFx 18.1 115.0 st1 LAUNDRY h 1074 46 17 0.369 6.0 OxO VIFx 20.4 115.0 sH M. BATM h 1133 48 30 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 MASTERBEDROOM h 2976 126 125 0286 6.0 OxO VIFx 40.1 135.0 st2 MASTERBEDROOM2 h 6635 282 266 0.352 7.0 OxO VIFx 27.2 115.0 st1 MASTERBEDROOM-A h 2976 126 125 0.297 6.0 OxO VIFx 33.1 135.0 st2 POWDER c 133 2 5 0.379 4.01 Ox0 VIFx 17.1 115.0 st1 WIG c 199 3 8 0.309 4.01 OxO VIFx 26.6 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cm) Minn) FR (fpm) (in) (in) Material Trunk s12 PeakAVF 622 631 0.286 803 12.0 0 x 0 UnlFlx st1 st1 PeakAVF 1084 1123 0.286 804 16.0 0 x 0 VInIFIX wrilghtsoit- 2021-JarF1307:44:09 RigH-SJicOUriversa1201919.021 RSU08101 / ...UICKDOo r&Wn9tzoft HUADWYNNE-GEMINInp Calc=MI8 FroNDoorf-acas: N Page Name Grille Size(in) Htg (dm) [Cig (cfm) TEL (ft) Design FR Ueloc (fpm) Diam (in) HxW (in) Stud/Joist Opening(in) Duct Mall Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 MR Wrlghtsof4' 2021-Jarv1307.4499 A•w'w� �-•� R1gRSU+ &Uriv TW1201919.021 RSU08101 Page t ...UICIMocurerM\WHghsoft HVAC\WY NE-GEMINI.,W Calc=MI8 ROMDoorfaces N