HomeMy WebLinkAboutPlans - Gemini - Right - Impact(1)FLOOR FL,4N
TYPICAL NOTES: SCALE 1/4" = I'-O"
I. Contractor to verify ALL notes and dimensions prior to w.H. = Water Heater
proceeding with work.
2. Contractor to STRICTLY enforce ALL OSHA requirements.
3. ALL Lumber to be used as Beam, rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
4. No dissimilar metals to touch.
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, cont. tle beams etc., to 0
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix -1,
6. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC r-102.3.5.
1. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" Wide door at one bathroom for
handicap accessibility requirements. 2,2" 2,2"
12. Lowest finished floor to be set by Governing Building Department %" 6 i2..
surveyor to set in field.
13. Separation between residence and garage shall be per FBC r302.�
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
15. Wall and Ceiling shall have a flame —spread classification of not greater than 200 pper FBC r302.9.1
l�. Wall and ceiling finishes shall have a smoke —developed index of not greater than -4 per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
With F.B.C. R31� — see permit info box of code edition
18. Gypsum board material shall conform to ASTM C3�, C19, C415, C514, C�30, C931
C��O, C1002, C1041,C1111, C1118, C1218, C1395, or C139and shall be installed
according to the following. (FBC r102.3.5)
Or wall
y
Thickness
Location
Orientation
Framing
Spa
Max. spacing
P 9
of fasteners
Nail sizing options for
installation of drywall into
in9
Nails
Screws
Maximum
wood framing members
2" x min. thickness
Ceiling
Perpendicular
24"
-1"
I2"
13g5 13/8" long with 19/64" head
0.098" diameter x 1 1/4" long
II
)/2
annular -ringed or 5d cooler nail
OR
Walls
Either
16"
8"
16"
0.080" dia. xx 1 6/8" long with
Direction
IS/64 head
OR
Gypsum board nail 0.086" dia.
x 1 5/8" with 9/32" head.
Ceiling
Perpendicular
24"
-1"
12"
13ga 1 5/8" bong with 19/64" head
OR
0.098" diameter x 1 3/8" long
s II
annular -ringed or 6d cooler nail
OR
Walls
Either
16"
8"
16"
0.092" dia. xx 1 -1/8" long with
Direction
1/4 head
OR
Gypsum board nail 0.0915" dia.
x 11/8" with 19/64" head.
Masonry Beam
I" x 4" P.T. Buck nailed to
block with case hardened nails
prior to door attachment head
and jambs
Install SGD Frame thru buck Into
block using tapcons as stated
in product approval form on sheet I.
Verify sill attachment req.
with product approval on -
sheet I.
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.�,
A108.1, A118.1, A118.3, A13LI and A131.1
20. Cement, fiber —cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, Or C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor —ceiling assemblies, roof —ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 With an accompan ingg smoke
developed index not to exceed 450 when tested in accordance witF ASTM E 84.
Insulation shall comply with F.B.C. r31�.
Uj lndCLU
Schedule
Mark
Size
Rou h 0 en.
Window Descrl tion
PRESSURE ZONE
I.
4'-5%8" X 5'-3 %8
54%,'x 63i4"
Single Hung
ZONE 4
2.
6'-2%8"x 5'-3 %8"
is" x 63 %4
Single Hung
ZONE 4
3
2'-2" x 3'-2 1/2"
2-1%2"x 38%"
Single Hung
ZONE 4
4.
4'-5%8"x 4'-2 %8"
54%,'X GO/,8"
Single Hung
ZONE 4
S.
6'-O%"x 4'-2%"
15%"x 50Y8
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit info box on
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturer s specs prior to construction
sheet
ID oor S
c h e d u I &
Mark
Size
Rough Opening
Door Description
PZONEURE
A
9'-0" X -1'-0"
108" x 84"
Overhead Garage Door
IMPACT
RATED
ZONE 4
B
3'-O" X 6'-V"
Y Q
41 �'`i„x 83%4"'
Fiberglass Panel - Inswing
IMPACT
RATED
ZONE 4
C
5'-O" X 6'-8"
62" x 83 %z" "
Single Lite French
9
IMPACT
RATEO
ZONE 4
D
2'-0" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81 %2"
E
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel
F
6'-0" X 6'-8"
Solid Core - Wood
- 6-Panel - double pocket
G
2'-8" x (.'-s If x I %4"
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
K
4'-O" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
I'-6" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet :4 1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified by contractor
With manufacturer s specs prior to construction
I is -
Bottom Track e- il
CR4SH POST DET/41L
36" high by 4" diameter
steel crash post. Floor
Flange with 4 - 3/8"
expansion bolts into
slab (3/8"t 5o ksi steel plate)
6"
2%' 2 %'
MIMMOM
_Z> 1 0
°3/8" � 2/2„
2
0 0
iding door
Typical Flooring
N_T.S.
AREA CALCULATIONS
Living A/C = 1839 sq. ft.
Front Porch = 2� sq. ft.
Rear Porch = 100 sq. ft.
Garage = 311 sq. ft,
Total Under Roof= 2,282 sq. ft.
Total Cubic Pt = 15,581.E
Install doors thru buck Into
block using tapcons as stated
in product appproval form on sheet I.
Exterior face Buck to be Z x 6" PT
Detail at Door
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
I" x 4" P.T. Buck nailed to
block with case hardened nails
prior to door attachment
Masonry Wall
Install SGD Frame thru buck into
block using tapcons as stated
in product approval form on sheet I.
Jamb
Sliding Door Detail
At Masonry Wall NTS
Install windows thru buck into
block using tapcons as stated
Exterior face in product approval form on sheet I.
of wall
Varies
I"x'4" P.T. Buck nailed to
block with case hardened nails
prior to window attachment
Detail at Windows
NTS
Metal roofing and underlayment intstalled per Product Approval
as shown on sheet I over CDX decking - see roof sheeting
attachment diagram on roof plan.
12
4
Truss mfg to provide level
return to be I" short of wall
Aluminum Drip
Edge t Fascia
2" x 4" Sub -Fascias 12"
Kaycan full o vent vinyl soffit' installed
per product approval form on sheet I.
I" x 4" nailer attached to
level return with (2) 8d ---
ring shank nails with min. 1.5"
penetration into soffit framing
5/8" thick light textured
stucco on typical concrete
block construction
45 bar vert. w/
30" overlap —
at each filled cell
Wood
Base
Grade
�I
TYPIC/4L SECTION
:t approval for
j Into wall req.
NTS
2
F-
I 2 „1
31, � Z" VTR
L6-1 I � � �L
LIAv-i I
2" MASTER
BATH 2"
Z" AAV wM-1
JIL WC-1
2" LAV-I
.2"
2 KITCHEN -�
2"LAUNDRY
' I
I
i
� I
i LAV -1
i
2 POWDER
we-IZ' VTR
J1
\" '
MASTER BATH #2
jj 2
JAV-1 -1
C.O.UAV
"
PLuMISING RiSER
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
�R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
-and (1) #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (1) 45
bar cont. for bottom row over openings
1/2" drywall over I" x furringg
strips at 16" o.c. with R4.1 fl-foil
-insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar yoints shall comply with FBC60�.2.1.
Provide Dur—O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with grout and
(1) 45 bar vert. (typical).
-Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"xC 1*10/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill
14"w x 18tid Concrete footing
with (2) 1*5 bars cont. and 1*5
transverse bars at 48" o.c.
Scale 1/2" = I'-O"
CMNRCT TO
C
i=
Digitally signed by
Daniel R. Braden
Date: 2021.08.25
15:49:36-04'00'
d)
0
v
�
I
'
oN�U
ra
Ll
nQ-
1.1�
O
U
Z
LILI
�Q
Z
Z
W
J--1--1
Q
Q
LL
O
U
J- L1
n
N
fn
/—
p[
W
LLl
=3
u
O
ZW
00
O
}
M H
v
O
<
��JCZ
0
I-
L
Z(��!
N v
#
O,.
-, -10
LLI
U��-�
m
~
Lq
x
—1
SHEET NO:
2.
OF 5,
JOB NUMBER:
AGE 9770
° o
FCUN[DA7CN PLAN
35'-O"
STRUCTURAL NOTES:
1. ANY CHANGES TO THE PLANS MUST BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL BEFORE PROCEEDING WITH
CONSTRUCTION
2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION
OF ALL NOTATION AND DIMENSIONS PRIOR TO START OF
CONSTRUCTION
3. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
4.. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
5` POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
SLAB ON GRADE TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 96% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
8. GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
q. GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
10. CONTACTOR TO VERIFY ALL RECESS THICKNESSES AT SHOWERS
FLOOR FINISH CHANGES, SPECIALTY EQ. ETC...
45 bar vert. w/
30" overlap Fill cell with concrete and
at each filled c (1) #5 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
SCALE: 1/4" = I'-O"
II. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
12. CONTRACTOR TO PROVIDE SOLID FILLED CELL AND U5 BAR VERT. AT
48" O.C. MAX. PROVIDE (1) FILLED CELL ON EACH SIDE OF OPENINGS
UP TO 5'-11" WIDE. PROVIDE (2) FILLED CELLS ON EACH SIDE OF OPENINGS
6'-O" WIDE AND UP. VERIFY ALL FILLED CELL LOCATIONS WITH FOUNDATION
PLAN.
13. DESIGN LOADS ARE AS FOLLOWS:
SEE PERMIT INFO BOX ON SHEET I.
14. ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
I5. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
16. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
1� LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
18. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
19. ALL STANDARD STRUCTURAL LUMBER SHALL BE SYP WITH A MINIMUM
SOUTHERN YELLOW PINE 42. MIN. Fb AS FOLLOWS:
2" x 4" = Fb 1,500 PSI 2" x 10" = Fb 1,000 PSI
2" x 6"/8" = Fb 1,200 PSI 2" x 12" = Fb 915 PSI
20. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
21. CONTRACTOR TO PROVIDE FORM BOARD SURVEY AND FURNISH
TO TRUSS MFG PRIOR TO TRUSS CONSTRUCTION FOR ACCURACY TO FIELD
Termite Protection for New
Construction as per F.B.C. R318.1
CONTRACTOR TO REFERENCE F.B.C-R
FOR FURTHER REQUIREMENTS
Wood see foundation plan notes for Thicken edge to 8"x8"
Base spacing at openings with concrete and 4" concrete slab with fibermesh OR
4" concrete slab with fibermesh OR one 45 bar continuous 6"x6" 410/10 WWM on 10 mil Visqueen over
6"x6" #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill
clean compacted termite treated fill GRADE
Grade
14"w x 18"d Concrete footing
I- with (2) 45 bars cont. and #5
transverse bars at 48" o.c.
Le 14°
TYPICAL FOOTING DETAIL
J SCALE 1/2" = 1'-0"
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Step per
foundation plan
v
3' X 3" '(2) #5 bars cont. bottom steel
M1�
�2"
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied p
into lintels above
Top of Tooter
16" below finished floor
12"
III-
01 30"x30"xl6" concrete
_ column footing with (4)
aIIII III U5 bars each way
3'
30"
3 COLUMN FOOTING DETAIL
SCALE 1/2" = 1'-0"
I I_4i111......
I-81
PORCH SLAB EDGE DETAIL
SCALE 1/2" = r-O"
45 bar vert. w/
30" overlap
at each filled cell
45 bar cont. in curb Fill cell with grout and
(1) 1*5 bar vert. (typical).
Max. spacing shall not exceed
Curb height Wood 48" unless otherwise noted
Verify based on see foundation plan notes for
foundation plan Base spacing at openings
4" concrete slab with fibermesh OR
6 x6 #10/10 WWM on 6 mil Visqueen over
CE
clean compacted termite treated fill
Grade —
777%
. D .... III�-
'II 7-r-
II U_ 14"w x 18"d Concrete footing
I I Itwith (2) #5 bars cont. and #5
'3 transverse bars at 48" o.c.
14"
GARAGE CURB DETAIL
Min SCALE 1/2" = I'-O"
Edge
Diat
E
0 Contractor to provide
Ctl proper foundation chairs
for proper steel installation
30 min.
2" x 6" PT wood secured with \ Corner Steel L a p
1/2"dia. x 6" expansion anchors
with 2" sq. washer at 18" o.c. overhead door track secured to wood n t S
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED N T S
IN PERMIT INFO BOX ON SHEET 41. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
FCCT1NG
SCHEDULE
Mark
Size
Description
FI
14"W
x 18"D
MONOLITHIC FOOTING
WITH 2 45 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) 45 BARS CONTINUOUS
30"
x 30" x 16"p
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
F4
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 45 BAR CONTINUOUS
14"W
x 18"D
FS
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB 9 O'-O"
With
Curb at Garage
Filled Cell Masonry Column With One
U5 From Footing To Beam Each. Filled Cell Masonry Column With One
Grout fill To Be 3000 PSI 45 From Footing To Tie Beam
See Floor Plan For Location Grout fill To Be 3000 PSI
Double Filled Cell Column
NTS
See Floor Plan For Location
Eo
A
Single Filled Cell Column
NTS
Digitally signed by
Daniel R. Braden
J�Ae�2_Date: 2021.08.25
15:49:21-04'00'
0
v
11
1Q
1J�
O
U
V Z
z
0 �
W
m �
z W
z =
U
N Q
0
a
w
Q
Q
�_=?f__ I UI
N
[L nc w m
w =3 U O
Z1? ao U O
}
CL L
ZN N ##
� ~ O
Lu
U��-Co
~ w �XLL
SHEET NO:
a -
OF 5,
JOB NUMBER:
17-209 B
1` o AGE 9770
5.
°�
oQ°0°°.no °o°a°°�°0 �5C
A
L
Provide 45 bars with 12" min. lap
into beam and 48 bar dia, into
vert. filled cell.
Provide Cast -Crete
8U16-I13/IT precast -
lintel set in mortar
Min. 8" Bearing
Fill lintel solid with
grout.
#5 cont, beam steel to run
through lintel and tie to
down rods in jamb cells.
Provide PT Buck
attached per jamb
letails into filled ce
4" Pre -cast
Sill
rout Filled Cell
Provide 45 bars with 12" min, lap
into footing and 48 bar dia, into
vert. filled cell.
.'
Concrete Footin
See foundation plan for
.
for exact sizes
DETAIL AT WINDOW OPENINGS IN
CBS WALL
Concrete
/ Lintel
Column
Verify with Plan
Rebar
t0 Lint&l
Scale: 1/2" = I'—O"
12 "x 12"
Column Block
Rebar
48 Bar Dia.
Min. Overlap
,,,4 ttachm&nt
NTS
BEAM SCHEDULE
Mark Size and Description
Two rows of beam block filled with concrete and 1 45 bar
BI continuous in each row. Hook vert. bar over top bar with
#5 90' bend bar with a 10" min. lap at top bar.
Additional Precast Lintel „
45 bars _ Lintel Bar Clear A B
Length Length Span Bars Bars
CLEAR
2'-10" 2'-8" 116" 2,#3 none
3'-4" 2'-2" 2,U3 none
8F8-OB/IT 8F8-IB/IT 8F8-IB/2T
Additional 4'-O" 3'-10" 2'-8" 2,u3 none
#5 bars
CLEAR .. 4'-6" 4'-4" 3'-2" 2,#3 none
fOn Row of "H"
k Above 5'-2" 4'-O" 2,U3 none
2,#4 none
r M Precast Lintel r .(
Additional " F 2,#4 none
� � �' F
#5 bars
-1'-6" _1'-O" 6'-2" 2,#5 none
8FI6-IB/IT 8FI6-IB/2T
NOTES; 7'-0" 2,#5 none
I. min. coverage of steel=1.5"
2. min. bearing required 8 ea. end=8" ALL reinforcing steel is grade 60.
3. standard for reinf. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE >
LINTEL SCHEDULE
Mark
Window
or Doo
Unit
Width
Lintel
Size
Specification
Rows of
"H" Block
Above
"
Bottom
Steel
Size
Top
Steel
Size
Max.
Gravity
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max.
Lateral
Load
(PLF)
L22
2'-2"
V-6"
8FI6-I15/IT
ONE
1
#5
1
u5
6113
3541
2854
L31
2'-6"
2'-8"
3'-1"
4'-0"
8FI6-IB/IT
ONE
1
#5
1
45
2931
3019
2128
L45
4'-5"
5'-10"
8FI6-IB/IT
ONE
1
#5
1
45
4360
2093
946
L50
5'-0"
6'-V
8FI6-IB/IT
ONE
1
#5
1
#5
3480
1880
1204
L60
6'-8"
l'-V
8FI6-IB/IT
ONE
1
#5
1
#5
2661
1634
891
LSO
8'-0"
9'-4"
8FI6-8/IT
ONE
1
#5
1
#5
1843
1133
-139
L90
9'-0"
10'-6"
8FI6-IB/IT
ONE
I
#5
1
#5
1 1533
914
5-19
L90B
9'-0"
10'-6"
8FI6-IB/IT
ONE
1
#5
1
#5
1533
914
5-19
LI00
10'-0"
ll'-4"
BPI(.-IB/IT
ONE
1
#5
1
#5
1366
198
604
LIOOB
10'-0"
ll'-4"
8FI6-IB/IT
ONE
1
#5
1
#5
1366
198
604
L120
12'-0"
13'-4"
8FI6-IB/IT
ONE
1
#5
1
#5
1016
606
433
L120B
12'-0"
13'-4"
8FI6-IB/IT
ONE
1
#5
1
#5
1015
606
433
L140
14'-0"
15'-4"
8FI6-IB/IT
ONE
1
#5
1
#5
1250
485
341
LI60
16'-0
8F8-IB/IT
ONE
1
#5
1
#5
950 1
404
25-1
L140B
16'-O"
1 I-'-4"
81=I(.-IB/IT
ONE
I
#5
1
#5
1 950
1 404
1 25-1
- ALL LINTELS SHALL BE MADE BY CAST-CRETE OR LOTTS LINTELS
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED.
HIP ROOF SHEETING
ATTACHMENT DETAIL
I.
Minimum Nail Size = 8d angular ring shank (min. 2.5" long)
2.
Minimum Screw Size = #8 x 2.5"
3.
Minimum Sheathing Thickness 19/32" CDX Plywood
4.
Use nails or screws based on pressure for roof
stated
in
zpermit info box on these plans for appropraite roof
ones.
4 FT(:LE)
TYPICAL
GABLE
2N
4�
2
TYPICAL
I
3®
_
4 FT 2R
1 ZE
2R 4 FT
--
F
u_
117
4 FT I
30
4 FT ZE 4 FTC
Ke
Area
Edge
Field
Fastener
Pressure
Zone
I
8d
x
2.5"
ring
shank
45 psf
Zone
2E, 2R,
2N
8d
x
2.5"
ring
shank
16 psf
Zone
3E/3R
8d
x
2.5"
ring
shank
8-4psf
ANY
ZONE
#8
x
2.5"
Screw
263 ps
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vert. leg of
truss with IOd x 1.5" nails at 4" O.C.
Install Simpson MGT into wall using
5/8" dia. threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
R
3LOCKING DETAIL
)ER STRAPPING
TER BEARING POINT
1/8" thick light textured stucco installed per
ASTM C 926 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Type 2 felt paper using 8d nails. Substrate
to be 19/32' COX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Metal roofing and underlayment intstalled per Product Approval
as shown on sheet I over COX decking - see roof sheeting
attachment diagram on roof plan. \
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) lod x 1 1/2" nails
( l supporting Max.
1810101bs. uplift
Truss mfg to provide level
return to be I" short of wall
Aluminum Drip
Edge & Fascia
2" x 4" Sub -Fascias /f12"
Kagcan full o vent vinyl soffit installed
per product approval form on sheet I.
I" x 4" nailer attached to�
level return with (2) 8d
ring shank nails with min. 1.5"
penetration into soffit framing
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert, tied
into lintels above
thicken edge to 8"x8"
with concrete and
one #5 bar continuous
BEYOND
Top of footer
16" below finished floor
12
4
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd ils
at each web
5/8" thick stucco on 3/8" hi -rib lath
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertical wood framing members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
A
45 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step per foundation plan
Slope per foundation plan °p
Wood
Base
40 I 1=1 I I 1
3 Tubical Section
Trusses at 24" o.c.
re shop drawings
I others
ceiling transition !f
ded using metal studs
erify exact configuration
Bs
Ceil1nQ transition Insulation
Brace Gable end
with 2" x 4" SYP 42
8ft back nailed to bottom
of top chords using (2) 10d
nails at each truss
PRE-ENGINEER4---D WOO[
24"o.c. TYPICAL
( shop drawings by manufaci
\R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cont, in each row. Substitute
precast lintel filled with concrete and (1) 45
bar cont. for bottom row over openings
1/2" dr wall over I" x furring
strips a 16" o.c. with R4.1 f I -foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.
and shall meet all pertaining ASTM codes.
oo Mortar to be Type "M" only proportioned �pper
and Mortar joints shall comply with FBC R6C
Provide Dur-O-Rock at all wet areas (ex. s
Fill cell with Grout and
(U #5 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings —
4" concrete slab with fibermesh OR — ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
Cx6" 1*10/10 WWM on 6 mil Visqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill _ ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
Simpson HETA 20 Strap truss to wall using Simpson MGT with
hurricane anchor at each truss 5/8' dia. threaded rod with min 12" embedment
into beam either wet set or in epoxy with
„(P 26" Batcs) supporting Max. (22) IOd nails into truss. Add blocking to
Fable end
x 4" SYP 42
nailed to bott
:hords using (2)
each truss
II — ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR Digitally signed
FI TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION by Daniel R.
CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO Braden
at Front P Or C PROVIDE FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO Date: 2021.08.25
Scale I/2" = I'—O" TRUSS CONSTRUCTION
15:49:11-04'00'
IVA
�
I
oN�U
Op
Q
U
Q
1J—
�L
O
U
Z
Q
W
Z
Z
0
Q)
U
N Q
0
W
Q
Q
U
0)
N
t�l
QL
W
W
=3
"
O
Z
�?
00
U
O
}
0)
Q)
O
<
000
0
L
Z
##
1
N N Z
~
O
rr�
ul
0
D
m
~
W
v X v
LL
L
U
vi
4-)
SHEET NO:
OF 5.
JOB NUMBER:
1` o AGE 9770 o�
°M
ao��n� a
\`�O . " �� Q nn
P,4NEL
"A"
Poles
BR
Load
Wire
Description
circ#
circa
Description
Wire
Load
BR
Poles
1
20
1.2 kw
#12
Refrigerator
1
Ran a
44
12.0 kw
50
2
1
20
1.2 kw
412
Clothes Washer
3
1
20
1.5 kw
#12
Kitchen S.A.C.
5
6
1> er
#10
5.0 kw
30
2
1
20
1.5 kw
912
Kitchen S.A.C.
1
8
1
1-
1
20
#12
Bathroom Recepts
9
10
Air CondaQsor
410
5.0 kw
30
2
I
20
1.2 kw
412
Dishwasher
II
12
I
20
1.2 kw
412
Microwave
13
14
Air 14andl r
#10
5.0 kw
30
2
1
15
914
General Lighting
15
I6
I
15
914
General Lighting
IZ
I8
WH
410
5.0 kw
25
2
I
15
#14
General Lighting
19
20
I
15
#14
General Lighting
21
22
GOO
412
0.81 KW
20
1
I
15
914
General Lighting
23
24
Spare
Spare
25
26
Spare
Spare
21
28
Spare
Spare
29
30
Spare
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3 watts sq. ft.)
Small Appliance Circuit(s)
Range
Refrigerator
Microwave
Dish Washer
Clothes Washer
Clothes Dryer
Water Heater
Garage Door Opener
2496
3
2,283
2
1.500
3,000
1
12.000
12.000
1
1.200
1,200
I
I.500
1,500
1
1,200
1,200
1
1.200
1,200
1
5.000
5.000
1
4,500
4,500
1
810
810
Total Watts
3-1,898
First 10000 Watts 5100%
1
10.000
10,000
Remainder 21898 840%
1
O
11,159
Electric Heat or A/C 10.000 e65%
1
10.000
10,000
Calculated Load
Watts
31,159
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.83
Panel Size Required = 150 Amps
Electrical Symbol Legend-]
$
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
PB
Push Button Switch
-0-
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
Wall Mounted Light
�
c
Waterproof ground fault circuit
interrupter
PC
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Fc-m-1
Carbon Monoxide Detector
Flood Light
Q
Thermostat
m
Electrical Panel
©
Central Vac
Electrical Meter
SQ
Smoke Detector
Ceiling fan
Tv
Television Jack
Telephone Jack
A oi c
A/C Disconnect
®
1 x 4 Florescent Light
®
2 x 4 Florescent Light
SPKR
Speaker Hook -Up
FB = JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
= BALANCED AIR
Vent thru
Soffit
FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW
A/C disc.
(3) UI THHN Copper
2" PVC Schedule
40 conduit GO
MCS
AMP
PA EL L Ai-IU
200a rated O
meter can
METER
Intersystem bonding
2" PVC ( FPL)-� Termination point
schedule 80
2" rigid service FPL
GEC Bare 1t6 co�pper wire
to (2) 8'-V' Galvanzied
ground rods
ELECTRICAL RISER
A/C disc.
U2/0 AL SER Cable
With $$I Grind
2" PVC Schedule
40 conduit Sleeve ISO
AMP
into attic MCB AHU
200a rated O
meter can
METER
Intersystem bonding
2" PVC ( FPL }-� Termination point
schedule 80
2" rigid service FPL
GEC Bare U4 co per wire
to (2) 8'- " Galvanzied
ground rods
ALTERNATE SERVICE ELECT. RISER
- Contractor shall
use AL-CU Landing lugs. NTS
- Contractor shall
use AL-CU Landing lugs. NTS
- Contractor shall
torque lugs I.A.W.
- Contractor shall
torque lugs I.A.W.
manufacturers recommendations
which
manufacturers recommendations
which
shall be verified
prior to construction
shall be verified
prior to construction
- Verify AIC/KIC
Rating prior to ordering equipment
- Verify AIC/KIC
Rating prior to ordering equipment
ELECTRIC NOTES:
I. Use copper wire only from panel to devices
2. Provide and wire all required smoke it Carbon
Monoxide detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL bath and kitchen receptacles to be GFCI protected
S. ALL exterior outlets to be WP/GFCI protected.
6. Recessed cans to be installed per NFPA requirements.
1. Tamper resistant AFCI receptacles are required in
ALL rooms.
8. A/C Return Air Balance Must comply w/ FBC RM1602
9. A/C Refrigerant lines that are run thru slabs must be
sleeved in PVC
10. ALL A/C Equipment shall comply with energy calculation
II. All work shall be performed by a licensed electrical
contractor, the completed system shall be fully operative.
12. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
13. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
14. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
15. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
16. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
11. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
18. The electrical system shall be completely and effectively
grounded as required by the latest edition of the N.E.C.
19. All material shall be new and shall bear underwriters'
labels where applicable.
Covered Porch
121 CFM
IOxIOx-1
SITTI G
20 M
103 CFM Center Registers 103 CFM
on ceiling fan
IOxIOx� I OxlOx1
12it
DINING
ROOM
132 CFM 1
IOxIOx-
I I
I
I
I
I
I
I
M,4STER
I BEDROOM �
132 CFM
IOxIOx-
-- - - --
- J
12x10
B/A
ra rin
L12xI2xI0
B/A
SET
8 CFM
8x4x4 0
J W T 20x2O -
8x4x4 fR/A
6 CFM tl
�i ingJ
UJ
D*
I
8x4x4 >
CFM - - - -
� I OBI
CLOSET
8x4x4
I CFM
8x4x4
39 CFM
Ic J
B/A
2xl2x10
r 12 x6 x-T_
280 CFM
I
M,4S7F_
I BEDROOM I oVERED
2 I PORCH
L
20. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
21. Furnish and install all fixtures as called for on the plans
or as selected by others.
22. All raceWays and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
23. All exposed wire below 9'-I" shall be installed in metal EMT
conduit.
24. Dryer Vents to be installed per
FBC RM1502
K
Ha CFM
12x6x-1
Oi -7--
22" x 54" - 1
Attic Access
with light
8x4x4
32 CoFM
BAT
491
ISO AMP
Panel
0/4R140F_
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
H.B.
Vent _t1 ru
Soffit
A/C
ust Duct
Thru Soffi
1"ieter
Wire For
Front Post
Light
Post Light with
Photo cell
TF-,,ICAL
Exhaust Duct
Thru Soffit
1�
QL
O
U
Q
4" Exhaust w
Duct Thru
�UaII �
WP GFCI
Ii nstall dsc.let
� LH
under dsc.
not shown for
clarity
A / C � v
�I
N
(L W w E
6
w O
O
Meter Z w oo cal � O
Z LO oo O
-1 Q 000�s Q
p- r >- <
z NN #
L O
U O rr�
0 �3
„..�3
o ~LLI x.. J
1.L �
LL
U N
to
n�
F L ,,,4
�.1
1 �
J-1--1
SHEET NO:
3C 230°►.� 01= 5.
JOB NUMBER:
required 1�-20� B
I QOa���Q��o°W
R. BRADt
Digitally signed by o� .°®
o° °
Daniel R. Braden o�o AR9770 °-
Date: 2021.08.25 °�0 ° °°o�o�o C
15:47:22-04'00'
��OOOD�
L