HomeMy WebLinkAboutReview Comments Date: 5/18/2017 To: Plan Revie"o
St Lucie County Building Department
Subject: Cover Letter
Review Comments
1704-0266
This Cover Letter serves as a guideline to the requested Permit Condit llions,for project 1704-0266. The
items are numbered and are in order as they were listed on the Review Comments,sheet.
I hope that we can expedite these corrections and break ground as soon as possible
• Energycalculation FORM R405 has been updated with correct'`information and will be
p
resubmitted entirely.
• Gable End comment:
• The house does not have a gable end. The front entry shows an open truss
detail, the flat area of the wall section that is seen above the door is a fill in
frame area above the roof line, and does not transfer to the interior space of
the building.
• Manual J Comment: HVAC design was completed by Engineer'of Record,Thomas E.Audit, P.E.
• Florida Building Code 2014 .
�M1401.3 Sizing: Heating and cooling equipment and ap pliances shall be sized
in accordance with ACCA Manual S based on building loads calculated in
accordance with ACCA Manual J r other APPROVED heating and cooking;
m
rnetho'dologies.
• Product Approval Requests
• All product approval request will be addressed and suibmitted on new Product Review
Affidavit form, Signed and Sealed by EOR,Thomas E. Audit, P.E.
• Flame Spread Index, please find notes in upper right corner clouded on FP J1
• Gypsum Board Materials,please find notes in upper right corner clouded on FP-1
• Climatic and Geographic Design Criteria, please find in Structural General Notes in upper right
corner clouded on S-1
• Carbon Monoxide Alarm
•. There is no need for Carbon Monoxide Alarms for this residence.
R315.1 Carbon Monoxide Protection: Every Separate ,building or a n� addition to an
existing building for which a permit for new construction is issued and having fossil=fuel
burnm heater`or a Nance,a fire lace, an attached ara e, or of I er feature,fixture,or
g pp p !; g _....
element that emits,carbon monoxide as byproduct„ofjcombustron{shall have an
operational carbon monoxide alarm installed within 10 feet of each room used for
sleeping purposes.
• Please Revise Left Elevation Page
• The left elevation is drawn in accordance with the floor plan. Please explain in detail
what is not correct.
• . Front Door
• The front door is stated on the plan as a side hinged and it is a 306'8,which is larger
than required minimum.
I;
• Interior Wall Detail, please find detail clouded on right hand side of FP-1
• Strapping Details, please see clouded on sheets S-2 and S-3
• Window and Door Flashing Details, please find on upper right corner on.sheet S-2
• Attic Access
• There are no air handlers or equipment being installed in the attic space.
1 I
• Manufacturers TrusOase
yout and Shop Drawings will be submitted in duplicate.
• Attic is Non-Vented, see note clouded on sheet S-3 �J
• Soil Bearing Capacity, please find EOR,Thomas E.Audit, P.E. note on sheet, 71
• Engineers notes reflect,the stated soil capacity on the plan is a building design
requirement, not actual site tested capacity. Soil must meet this minimum requirement
for building. Foundations cannot be properly tested until site is cleared. Soil data will
be submitted to building department prior to pouringof any foundations.
i
I
Stewart Cooper,Managing Member